Abstract

This article demonstrates a gateway system for converting image fusion results to digital imaging and communication in medicine (DICOM) objects. For the purpose of standardization and integration, we have followed the guidelines of the Integrated Healthcare Enterprise technical framework and developed a DICOM gateway. The gateway system combines data from hospital information system, image fusion results, and the information generated itself to constitute new DICOM objects. All the mandatory tags defined in standard DICOM object were generated in the gateway system. The gateway system will generate two series of SOP instances of each PET-MR fusion result; SOP (Service Object Pair) one for the reconstructed magnetic resonance (MR) images and the other for position emission tomography (PET) images. The size, resolution, spatial coordinates, and number of frames are the same in both series of SOP instances. Every new generated MR image exactly fits with one of the reconstructed PET images. Those DICOM images are stored to the picture archiving and communication system (PACS) server by means of standard DICOM protocols. When those images are retrieved and viewed by standard DICOM viewing systems, both images can be viewed at the same anatomy location. This system is useful for precise diagnosis and therapy.
Literatur
1.
Zurück zum Zitat Wahle, A, Bultjes, JH, Oswald, H, et al. 1996DICOM-integration in a heterogeneous environment. Proc 18th Int conf IEEE EngMed Biol Soc.12281229 Wahle, A, Bultjes, JH, Oswald, H,  et al. 1996DICOM-integration in a heterogeneous environment. Proc 18th Int conf IEEE EngMed Biol Soc.12281229
2.
Zurück zum Zitat Pavlopoulos, SA, Delopoulos, AN 1999Designing and implementing the transition to a fully digital hospitalIEEE Trans Inform Tech Biomed3619CrossRef Pavlopoulos, SA, Delopoulos, AN 1999Designing and implementing the transition to a fully digital hospitalIEEE Trans Inform Tech Biomed3619CrossRef
3.
Zurück zum Zitat Kimura, M, Ohe, K, Yoshihara, H, et al. 1998 MERIT-9: a patient information exchange guideline using MML, HL7 and DICOMInt J Med Inform515968CrossRefPubMed Kimura, M, Ohe, K, Yoshihara, H,  et al. 1998 MERIT-9: a patient information exchange guideline using MML, HL7 and DICOMInt J Med Inform515968CrossRefPubMed
5.
Zurück zum Zitat Oosterwijk, H 1998DICOM versus HL7 for modality interfacingJ Digit Imaging113941PubMed Oosterwijk, H 1998DICOM versus HL7 for modality interfacingJ Digit Imaging113941PubMed
6.
Zurück zum Zitat Peter, MK, Ruth, ED 2001Minimizing Digital Imaging and Communication in Medicine (DICOM) modality worklist patient/study selection errorsJ Digit Imaging.14 153157PubMed Peter, MK, Ruth, ED 2001Minimizing Digital Imaging and Communication in Medicine (DICOM) modality worklist patient/study selection errorsJ Digit Imaging.14 153157PubMed
7.
Zurück zum Zitat Wang, JK, Kao, T, Liu, RS, et al. 2003Optimizing the visualization of WB-PET imagesIEEE Eng Med Biol22141146CrossRef Wang, JK, Kao, T, Liu, RS,  et al. 2003Optimizing the visualization of WB-PET imagesIEEE Eng Med Biol22141146CrossRef
8.
Zurück zum Zitat Wu, TH, Wang, JK, Lee, JS, et al. 2002An imaging co-registration system using novel non-invasive and non-radioactive external makersEur J Nucl Med Mol Imaging30812818 Wu, TH, Wang, JK, Lee, JS,  et al. 2002An imaging co-registration system using novel non-invasive and non-radioactive external makersEur J Nucl Med Mol Imaging30812818
9.
Zurück zum Zitat Levin, DN, Hu, XP, Tan, KK, et al. 1989: The brain: integrated three-dimensional display of MR and PET images,Radiology172783789PubMed Levin, DN, Hu, XP, Tan, KK,  et al. 1989: The brain: integrated three-dimensional display of MR and PET images,Radiology172783789PubMed
10.
Zurück zum Zitat Bacharach, SL, Douglas, MA, Carson, RE, et al. 1992 Three-dimensional registration of cardiac positron emission tomography attenuation scansJ Nucl Med34311321 Bacharach, SL, Douglas, MA, Carson, RE,  et al. 1992 Three-dimensional registration of cardiac positron emission tomography attenuation scansJ Nucl Med34311321
11.
Zurück zum Zitat Kramer, EL, Noz, ME 1991CT-SPECT fusion for analysis of radiolabeled antibodies: applications in gastrointestinal and lung carcinomaNucl Med Biol182742 Kramer, EL, Noz, ME 1991CT-SPECT fusion for analysis of radiolabeled antibodies: applications in gastrointestinal and lung carcinomaNucl Med Biol182742
12.
Zurück zum Zitat Graves, EE, Pirzkall, A, Nelson, SJ, et al. 2001Registration of magnetic resonance spectroscopic imaging to computed tomography for radiotherapy treatment planningMed Phys Dec2824892496CrossRef Graves, EE, Pirzkall, A, Nelson, SJ,  et al. 2001Registration of magnetic resonance spectroscopic imaging to computed tomography for radiotherapy treatment planningMed Phys Dec2824892496CrossRef
13.
Zurück zum Zitat Yen, SH, Chao, LS, Hsiao, CH, et al. 2002Head and neck nodal station images: guidance for three-dimensional radiation therapy treatment planningJ Digit Imaging15240246CrossRef Yen, SH, Chao, LS, Hsiao, CH,  et al. 2002Head and neck nodal station images: guidance for three-dimensional radiation therapy treatment planningJ Digit Imaging15240246CrossRef
14.
Zurück zum Zitat DICOM Part 4, PS3.4–Service Class Specifications, National Electrical Manufacturers Association, Rosslyn, Virginia, USA, 2003. DICOM Part 4, PS3.4–Service Class Specifications, National Electrical Manufacturers Association, Rosslyn, Virginia, USA, 2003.
Metadaten
Titel
System Integration and DICOM Image Creation for PET-MR Fusion
verfasst von
Chia-Hung Hsiao, PhD
Tsair Kao, PhD
Yu-Hua Fang, MS
Jiunn-Kuen Wang, MS
Wan-Yuo Guo, MD, PhD
Liang-Hsiao Chao, MS
Sang-Hue Yen, MD
Publikationsdatum
01.03.2005
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 1/2005
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-004-1024-4

Weitere Artikel der Ausgabe 1/2005

Journal of Digital Imaging 1/2005 Zur Ausgabe

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.