Skip to main content
Erschienen in: Journal of Neuro-Oncology 2/2016

20.06.2016 | Clinical Study

The detectability of brain metastases using contrast-enhanced spin-echo or gradient-echo images: a systematic review and meta-analysis

verfasst von: Chong Hyun Suh, Seung Chai Jung, Kyung Won Kim, Junhee Pyo

Erschienen in: Journal of Neuro-Oncology | Ausgabe 2/2016

Einloggen, um Zugang zu erhalten

Abstract

This study aimed to compare the detectability of brain metastases using contrast-enhanced spin-echo (SE) and gradient-echo (GRE) T1-weighted images. The Ovid-MEDLINE and EMBASE databases were searched for studies on the detectability of brain metastases using contrast-enhanced SE or GRE images. The pooled proportions for the detectability of brain metastases were assessed using random-effects modeling. Heterogeneity among studies was determined using χ 2 statistics for the pooled estimates and the inconsistency index, I 2 . To overcome heterogeneity, subgroup analyses according to slice thickness and lesion size were performed. A total of eight eligible studies, which included a sample size of 252 patients and 1413 brain metastases, were included. The detectability of brain metastases using SE images (89.2 %) was higher than using GRE images (81.6 %; adjusted 84.0 %), but this difference was not statistically significant (p = 0.2385). In subgroup analysis of studies with 1-mm-thick slices and small metastases (<5 mm in diameter), 3-dimensional (3D) SE images demonstrated a higher detectability in comparison to 3D GRE images (93.7 % vs 73.1 % in 1-mm-thick slices; 89.5 % vs 59.4 % for small metastases) (p < 0.0001). Although both SE or GRE images are acceptable for detecting brain metastases, contrast-enhanced 3D SE images using 1-mm-thick slices are preferred for detecting brain metastases, especially small lesions (<5 mm in diameter).
Literatur
1.
2.
3.
Zurück zum Zitat Chang EL, Hassenbusch SJ 3rd, Shiu AS, Lang FF, Allen PK, Sawaya R, Maor MH (2003) The role of tumor size in the radiosurgical management of patients with ambiguous brain metastases. Neurosurgery 53:272–280 (discussion 280–271)CrossRefPubMed Chang EL, Hassenbusch SJ 3rd, Shiu AS, Lang FF, Allen PK, Sawaya R, Maor MH (2003) The role of tumor size in the radiosurgical management of patients with ambiguous brain metastases. Neurosurgery 53:272–280 (discussion 280–271)CrossRefPubMed
4.
Zurück zum Zitat Sills AK (2005) Current treatment approaches to surgery for brain metastases. Neurosurgery 57:S24–S32 (discusssion S21–24)CrossRefPubMed Sills AK (2005) Current treatment approaches to surgery for brain metastases. Neurosurgery 57:S24–S32 (discusssion S21–24)CrossRefPubMed
5.
Zurück zum Zitat Kocher M, Wittig A, Piroth MD, Treuer H, Seegenschmiedt H, Ruge M, Grosu AL, Guckenberger M (2014) Stereotactic radiosurgery for treatment of brain metastases. A report of the DEGRO working group on stereotactic radiotherapy. Strahlenther Onkol 190:521–532. doi:10.1007/s00066-014-0648-7 CrossRefPubMed Kocher M, Wittig A, Piroth MD, Treuer H, Seegenschmiedt H, Ruge M, Grosu AL, Guckenberger M (2014) Stereotactic radiosurgery for treatment of brain metastases. A report of the DEGRO working group on stereotactic radiotherapy. Strahlenther Onkol 190:521–532. doi:10.​1007/​s00066-014-0648-7 CrossRefPubMed
6.
Zurück zum Zitat Serizawa T, Hirai T, Nagano O, Higuchi Y, Matsuda S, Ono J, Saeki N (2010) Gamma knife surgery for 1–10 brain metastases without prophylactic whole-brain radiation therapy: analysis of cases meeting the Japanese prospective multi-institute study (JLGK0901) inclusion criteria. J Neurooncol 98:163–167. doi:10.1007/s11060-010-0169-x CrossRefPubMed Serizawa T, Hirai T, Nagano O, Higuchi Y, Matsuda S, Ono J, Saeki N (2010) Gamma knife surgery for 1–10 brain metastases without prophylactic whole-brain radiation therapy: analysis of cases meeting the Japanese prospective multi-institute study (JLGK0901) inclusion criteria. J Neurooncol 98:163–167. doi:10.​1007/​s11060-010-0169-x CrossRefPubMed
7.
Zurück zum Zitat Chang WS, Kim HY, Chang JW, Park YG, Chang JH (2010) Analysis of radiosurgical results in patients with brain metastases according to the number of brain lesions: is stereotactic radiosurgery effective for multiple brain metastases?. J Neurosurg 113 Suppl:73–78PubMed Chang WS, Kim HY, Chang JW, Park YG, Chang JH (2010) Analysis of radiosurgical results in patients with brain metastases according to the number of brain lesions: is stereotactic radiosurgery effective for multiple brain metastases?. J Neurosurg 113 Suppl:73–78PubMed
8.
Zurück zum Zitat Kakeda S, Korogi Y, Hiai Y, Ohnari N, Moriya J, Kamada K, Hanamiya M, Sato T, Kitajima M (2007) Detection of brain metastasis at 3 T: comparison among SE, IR-FSE and 3D-GRE sequences. Eur Radiol 17:2345–2351. doi:10.1007/s00330-007-0599-9 CrossRefPubMed Kakeda S, Korogi Y, Hiai Y, Ohnari N, Moriya J, Kamada K, Hanamiya M, Sato T, Kitajima M (2007) Detection of brain metastasis at 3 T: comparison among SE, IR-FSE and 3D-GRE sequences. Eur Radiol 17:2345–2351. doi:10.​1007/​s00330-007-0599-9 CrossRefPubMed
9.
Zurück zum Zitat Furutani K, Harada M, Mawlan M, Nishitani H (2008) Difference in enhancement between spin echo and 3-dimensional fast spoiled gradient recalled acquisition in steady state magnetic resonance imaging of brain metastasis at 3-T magnetic resonance imaging. J Comput Assist Tomogr 32:313–319. doi:10.1097/RCT.0b013e318074fd9d CrossRefPubMed Furutani K, Harada M, Mawlan M, Nishitani H (2008) Difference in enhancement between spin echo and 3-dimensional fast spoiled gradient recalled acquisition in steady state magnetic resonance imaging of brain metastasis at 3-T magnetic resonance imaging. J Comput Assist Tomogr 32:313–319. doi:10.​1097/​RCT.​0b013e318074fd9d​ CrossRefPubMed
10.
Zurück zum Zitat Takeda T, Takeda A, Nagaoka T, Kunieda E, Takemasa K, Watanabe M, Hatou T, Oguro S, Katayama M (2008) Gadolinium-enhanced three-dimensional magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging is superior to spin-echo imaging in delineating brain metastases. Acta Radiol 49:1167–1173. doi:10.1080/02841850802477924 CrossRefPubMed Takeda T, Takeda A, Nagaoka T, Kunieda E, Takemasa K, Watanabe M, Hatou T, Oguro S, Katayama M (2008) Gadolinium-enhanced three-dimensional magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging is superior to spin-echo imaging in delineating brain metastases. Acta Radiol 49:1167–1173. doi:10.​1080/​0284185080247792​4 CrossRefPubMed
11.
Zurück zum Zitat Komada T, Naganawa S, Ogawa H, Matsushima M, Kubota S, Kawai H, Fukatsu H, Ikeda M, Kawamura M, Sakurai Y, Maruyama K (2008) Contrast-enhanced MR imaging of metastatic brain tumor at 3 T: utility of T(1)-weighted SPACE compared with 2D spin echo and 3D gradient echo sequence. Magn Reson Med 7:13–21CrossRef Komada T, Naganawa S, Ogawa H, Matsushima M, Kubota S, Kawai H, Fukatsu H, Ikeda M, Kawamura M, Sakurai Y, Maruyama K (2008) Contrast-enhanced MR imaging of metastatic brain tumor at 3 T: utility of T(1)-weighted SPACE compared with 2D spin echo and 3D gradient echo sequence. Magn Reson Med 7:13–21CrossRef
12.
Zurück zum Zitat Kato Y, Higano S, Tamura H, Mugikura S, Umetsu A, Murata T, Takahashi S (2009) Usefulness of contrast-enhanced T1-weighted sampling perfection with application-optimized contrasts by using different flip angle evolutions in detection of small brain metastasis at 3 T MR imaging: comparison with magnetization-prepared rapid acquisition of gradient echo imaging. Am J Neuroradiol 30:923–929. doi:10.3174/ajnr.A1506 CrossRefPubMed Kato Y, Higano S, Tamura H, Mugikura S, Umetsu A, Murata T, Takahashi S (2009) Usefulness of contrast-enhanced T1-weighted sampling perfection with application-optimized contrasts by using different flip angle evolutions in detection of small brain metastasis at 3 T MR imaging: comparison with magnetization-prepared rapid acquisition of gradient echo imaging. Am J Neuroradiol 30:923–929. doi:10.​3174/​ajnr.​A1506 CrossRefPubMed
13.
Zurück zum Zitat Nagao E, Yoshiura T, Hiwatashi A, Obara M, Yamashita K, Kamano H, Takayama Y, Kobayashi K, Honda H (2011) 3D turbo spin-echo sequence with motion-sensitized driven-equilibrium preparation for detection of brain metastases on 3 T MR imaging. Am J Neuroradiol 32:664–670. doi:10.3174/ajnr.A2343 CrossRefPubMed Nagao E, Yoshiura T, Hiwatashi A, Obara M, Yamashita K, Kamano H, Takayama Y, Kobayashi K, Honda H (2011) 3D turbo spin-echo sequence with motion-sensitized driven-equilibrium preparation for detection of brain metastases on 3 T MR imaging. Am J Neuroradiol 32:664–670. doi:10.​3174/​ajnr.​A2343 CrossRefPubMed
14.
15.
Zurück zum Zitat Reichert M, Morelli JN, Runge VM, Tao A, von Ritschl R, von Ritschl A, Padua A, Dix JE, Marra MJ, Schoenberg SO, Attenberger UI (2013) Contrast-enhanced 3-dimensional SPACE versus MP-RAGE for the detection of brain metastases: considerations with a 32-channel head coil. Invest Radiol 48:55–60. doi:10.1097/RLI.0b013e318277b1aa CrossRefPubMed Reichert M, Morelli JN, Runge VM, Tao A, von Ritschl R, von Ritschl A, Padua A, Dix JE, Marra MJ, Schoenberg SO, Attenberger UI (2013) Contrast-enhanced 3-dimensional SPACE versus MP-RAGE for the detection of brain metastases: considerations with a 32-channel head coil. Invest Radiol 48:55–60. doi:10.​1097/​RLI.​0b013e318277b1aa​ CrossRefPubMed
16.
Zurück zum Zitat Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM, Kleijnen J (2003) The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 3:25CrossRefPubMedPubMedCentral Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM, Kleijnen J (2003) The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 3:25CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Kim KW, Lee J, Choi SH, Huh J, Park SH (2015) Systematic review and meta-analysis of studies evaluating diagnostic test accuracy: a practical review for clinical researchers-part I. General guidance and tips. Korean J Radiol 16:1175–1187CrossRefPubMedPubMedCentral Kim KW, Lee J, Choi SH, Huh J, Park SH (2015) Systematic review and meta-analysis of studies evaluating diagnostic test accuracy: a practical review for clinical researchers-part I. General guidance and tips. Korean J Radiol 16:1175–1187CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Lee J, Kim KW, Choi SH, Huh J, Park SH (2015) Systematic review and meta-analysis of studies evaluating diagnostic test accuracy: a practical review for clinical researchers-part II. Statistical methods of meta-analysis. Korean J Radiol 16:1188–1196CrossRefPubMedPubMedCentral Lee J, Kim KW, Choi SH, Huh J, Park SH (2015) Systematic review and meta-analysis of studies evaluating diagnostic test accuracy: a practical review for clinical researchers-part II. Statistical methods of meta-analysis. Korean J Radiol 16:1188–1196CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Duval S, Tweedie R (2000) Trim and fill: a simple funnel-plot-based method of testing and adjusting for publication bias in meta-analysis. Biometrics 56:455–463CrossRefPubMed Duval S, Tweedie R (2000) Trim and fill: a simple funnel-plot-based method of testing and adjusting for publication bias in meta-analysis. Biometrics 56:455–463CrossRefPubMed
23.
Zurück zum Zitat Park J, Kim EY (2010) Contrast-enhanced, three-dimensional, whole-brain, black-blood imaging: application to small brain metastases. Mag Reson Med 63:553–561. doi:10.1002/mrm.22261 CrossRef Park J, Kim EY (2010) Contrast-enhanced, three-dimensional, whole-brain, black-blood imaging: application to small brain metastases. Mag Reson Med 63:553–561. doi:10.​1002/​mrm.​22261 CrossRef
24.
Zurück zum Zitat Yoneyama M, Nakamura M, Tabuchi T, Takemura A, Obara M, Tatsuno S, Sawano S (2013) Whole-brain black-blood imaging with magnetization-transfer prepared spin echo-like contrast: a novel sequence for contrast-enhanced brain metastasis screening at 3T. Radiol Phys Technol 6:431–436. doi:10.1007/s12194-013-0216-3 CrossRefPubMed Yoneyama M, Nakamura M, Tabuchi T, Takemura A, Obara M, Tatsuno S, Sawano S (2013) Whole-brain black-blood imaging with magnetization-transfer prepared spin echo-like contrast: a novel sequence for contrast-enhanced brain metastasis screening at 3T. Radiol Phys Technol 6:431–436. doi:10.​1007/​s12194-013-0216-3 CrossRefPubMed
25.
Zurück zum Zitat Fellner F, Fellner C, Held P, Schmitt R (1997) Comparison of spin-echo MR pulse sequences for imaging of the brain. AJNR Am J Neuroradiol 18:1617–1625PubMed Fellner F, Fellner C, Held P, Schmitt R (1997) Comparison of spin-echo MR pulse sequences for imaging of the brain. AJNR Am J Neuroradiol 18:1617–1625PubMed
26.
Zurück zum Zitat Zhu W, Qi J, Wang C (2003) Comparative study of 3D-SPGR vs 2D-SE T1WI after enhancement in the brain. J Huazhong Univ Sci Technol Med Sci (Hua zhong ke ji da xue xue bao Yi xue Ying De wen ban/Huazhong keji daxue xuebao Yixue Yingdewen ban) 23:180–183CrossRef Zhu W, Qi J, Wang C (2003) Comparative study of 3D-SPGR vs 2D-SE T1WI after enhancement in the brain. J Huazhong Univ Sci Technol Med Sci (Hua zhong ke ji da xue xue bao Yi xue Ying De wen ban/Huazhong keji daxue xuebao Yixue Yingdewen ban) 23:180–183CrossRef
27.
Zurück zum Zitat Naganawa S, Satake H, Iwano S, Kawai H, Kubota S, Komada T, Kawamura M, Sakurai Y, Fukatsu H (2008) Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence. Eur Radiol 18:337–342. doi:10.1007/s00330-007-0741-8 CrossRefPubMed Naganawa S, Satake H, Iwano S, Kawai H, Kubota S, Komada T, Kawamura M, Sakurai Y, Fukatsu H (2008) Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence. Eur Radiol 18:337–342. doi:10.​1007/​s00330-007-0741-8 CrossRefPubMed
28.
Zurück zum Zitat Qian YF, Yu CL, Zhang C, Yu YQ (2008) MR T1-weighted inversion recovery imaging in detecting brain metastases: could it replace T1-weighted spin-echo imaging? Am J Neuroradiol 29:701–704. doi:10.3174/ajnr.A0907 CrossRefPubMed Qian YF, Yu CL, Zhang C, Yu YQ (2008) MR T1-weighted inversion recovery imaging in detecting brain metastases: could it replace T1-weighted spin-echo imaging? Am J Neuroradiol 29:701–704. doi:10.​3174/​ajnr.​A0907 CrossRefPubMed
32.
Zurück zum Zitat Chappell PM, Pelc NJ, Foo TK, Glover GH, Haros SP, Enzmann DR (1994) Comparison of lesion enhancement on spin-echo and gradient-echo images. Am J Neuroradiol 15:37–44PubMed Chappell PM, Pelc NJ, Foo TK, Glover GH, Haros SP, Enzmann DR (1994) Comparison of lesion enhancement on spin-echo and gradient-echo images. Am J Neuroradiol 15:37–44PubMed
33.
Zurück zum Zitat Mugler JP 3rd, Brookeman JR (1993) Theoretical analysis of gadopentetate dimeglumine enhancement in T1-weighted imaging of the brain: comparison of two-dimensional spin-echo and three-dimensional gradient-echo sequences. J Magn Reson Imaging 3:761–769CrossRefPubMed Mugler JP 3rd, Brookeman JR (1993) Theoretical analysis of gadopentetate dimeglumine enhancement in T1-weighted imaging of the brain: comparison of two-dimensional spin-echo and three-dimensional gradient-echo sequences. J Magn Reson Imaging 3:761–769CrossRefPubMed
34.
Zurück zum Zitat Constable RT, Anderson AW, Zhong J, Gore JC (1992) Factors influencing contrast in fast spin-echo MR imaging. Magn Reson Imaging 10:497–511CrossRefPubMed Constable RT, Anderson AW, Zhong J, Gore JC (1992) Factors influencing contrast in fast spin-echo MR imaging. Magn Reson Imaging 10:497–511CrossRefPubMed
35.
Zurück zum Zitat Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gotzsche PC, Ioannidis JP, Clarke M, Devereaux PJ, Kleijnen J, Moher D (2009) The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. BMJ 339:b2700. doi:10.1136/bmj.b2700 CrossRefPubMedPubMedCentral Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gotzsche PC, Ioannidis JP, Clarke M, Devereaux PJ, Kleijnen J, Moher D (2009) The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. BMJ 339:b2700. doi:10.​1136/​bmj.​b2700 CrossRefPubMedPubMedCentral
Metadaten
Titel
The detectability of brain metastases using contrast-enhanced spin-echo or gradient-echo images: a systematic review and meta-analysis
verfasst von
Chong Hyun Suh
Seung Chai Jung
Kyung Won Kim
Junhee Pyo
Publikationsdatum
20.06.2016
Verlag
Springer US
Erschienen in
Journal of Neuro-Oncology / Ausgabe 2/2016
Print ISSN: 0167-594X
Elektronische ISSN: 1573-7373
DOI
https://doi.org/10.1007/s11060-016-2185-y

Weitere Artikel der Ausgabe 2/2016

Journal of Neuro-Oncology 2/2016 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

„Restriktion auf vier Wochen Therapie bei Schlaflosigkeit ist absurd!“

06.05.2024 Insomnie Nachrichten

Chronische Insomnie als eigenständiges Krankheitsbild ernst nehmen und adäquat nach dem aktuellen Forschungsstand behandeln: Das forderte der Schlafmediziner Dr. Dieter Kunz von der Berliner Charité beim Praxis Update.

Stuhltransfusion könnte Fortschreiten von Parkinson-Symptomen bremsen

03.05.2024 Parkinson-Krankheit Nachrichten

Kann eine frühzeitige Stuhltransplantation das Fortschreiten von Parkinson-Symptomen verlangsamen? Die Ergebnisse einer randomisierten Phase-2-Studie scheinen dafür zu sprechen.

Frühe Tranexamsäure-Therapie nützt wenig bei Hirnblutungen

02.05.2024 Hirnblutung Nachrichten

Erhalten Personen mit einer spontanen Hirnblutung innerhalb von zwei Stunden nach Symptombeginn eine Tranexamsäure-Therapie, kann dies weder die Hämatomexpansion eindämmen noch die Mortalität senken.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders scheint das auf weibliche Kranke zuzutreffen, wie eine Studie zeigt.

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.