We prospectively performed remote fetal cardiac screening using the spatio-temporal image correlation (STIC), and examined the usefulness and problems of remote screening. We performed heart screening for all pregnant women at four obstetrics clinics over the three years from 2009 to 2014. The STIC data from 15,404 examinations in normal pregnancies (16–27 weeks, median 25 weeks) were analyzed. Obstetricians and sonographer collected STIC data from four-chamber view images. Eight pediatric cardiologists analyzed the images offline. A normal heart was diagnosed in 14,002 cases (90.9%), an abnormal heart was diagnosed in 457 cases (3.0%), and poor images were obtained in 945 cases (6.1%). 138 cases had congenital heart disease (CHD) after birth, and severe CHD necessitating hospitalization occurred in 36 cases. We were not able to detect CHD by screening in 12 cases. The sensitivity and specificity of STIC in CHD screening was 50% and 99.5%, respectively. The sensitivity and specificity of STIC in screening for severe CHD was 82% and 99.9%, respectively. The STIC method was useful in fetal remote screening for CHD. However, the fact that > 10% of images that could not be analyzed by this method was a problem.
Literatur
1.
Zurück zum Zitat Achiron R, Glaser J, Gelerntter I et al (1992) Extended fetal echocardiographic examination for detecting cardiac malformations in low risk pregnancies. BMJ 304:671–674CrossRef Achiron R, Glaser J, Gelerntter I et al (1992) Extended fetal echocardiographic examination for detecting cardiac malformations in low risk pregnancies. BMJ 304:671–674CrossRef
2.
Zurück zum Zitat Zhao L, Wu Y, Chen S, Ren Y et al (2016) Feasibility study on prenatal cardiac screening using four-dimensional ultrasound with spatiotemporal image correlation: a multicenter study. PLoS ONE 11:e0157477CrossRef Zhao L, Wu Y, Chen S, Ren Y et al (2016) Feasibility study on prenatal cardiac screening using four-dimensional ultrasound with spatiotemporal image correlation: a multicenter study. PLoS ONE 11:e0157477CrossRef
3.
Zurück zum Zitat Bennasar M, Martínez JM, Gómez O et al (2010) Accuracy of four-dimensional spatiotemporal image correlation echocardiography in the prenatal diagnosis of congenital heart defects. Ultrasound Obstet Gynecol 36:458–464CrossRef Bennasar M, Martínez JM, Gómez O et al (2010) Accuracy of four-dimensional spatiotemporal image correlation echocardiography in the prenatal diagnosis of congenital heart defects. Ultrasound Obstet Gynecol 36:458–464CrossRef
4.
Zurück zum Zitat Novaes JY, Zamith MM, Araujo Júnior E et al (2015) Screening of congenital heart diseases by three-dimensional ultrasound using spatiotemporal image correlation: influence of professional experience. Echocardiography 33:99–104CrossRef Novaes JY, Zamith MM, Araujo Júnior E et al (2015) Screening of congenital heart diseases by three-dimensional ultrasound using spatiotemporal image correlation: influence of professional experience. Echocardiography 33:99–104CrossRef
5.
Zurück zum Zitat DeVore GR, Medearis AL, Bear MB et al (1993) Fetal echocardiography: factors that influence imaging of the fetal heart during the second trimester of pregnancy. J Ultrasound Med 12:659–663CrossRef DeVore GR, Medearis AL, Bear MB et al (1993) Fetal echocardiography: factors that influence imaging of the fetal heart during the second trimester of pregnancy. J Ultrasound Med 12:659–663CrossRef
6.
Zurück zum Zitat Evans W, Castillo W, Rollins R et al (2015) Moving towards universal prenatal detection of critical congenital heart disease in southern Nevada: a community-wide program. Pediatr Cardiol 36:281–288CrossRef Evans W, Castillo W, Rollins R et al (2015) Moving towards universal prenatal detection of critical congenital heart disease in southern Nevada: a community-wide program. Pediatr Cardiol 36:281–288CrossRef
7.
Zurück zum Zitat Pinto NM, Keenan HT, Minich LL et al (2012) Barriers to prenatal detection of congenital heart disease: a population-based study. Ultrasound Obstet Gynecol 40:418–425CrossRef Pinto NM, Keenan HT, Minich LL et al (2012) Barriers to prenatal detection of congenital heart disease: a population-based study. Ultrasound Obstet Gynecol 40:418–425CrossRef
8.
Zurück zum Zitat Carvalho JS, Mavrides E, Shinebourne EA et al (2002) Improving the effectiveness of routine prenatal screening for major congenital heart defects. Heart 88:387–391CrossRef Carvalho JS, Mavrides E, Shinebourne EA et al (2002) Improving the effectiveness of routine prenatal screening for major congenital heart defects. Heart 88:387–391CrossRef
Metadaten
Titel
The Evaluation of Fetal Cardiac Remote Screening in the Second Trimester of Pregnancy Using the Spatio-Temporal Image Correlation Method
verfasst von
Noboru Inamura
Takeshi Taniguchi
Tatsumi Yamada
Tomohiko Tanaka
Ken Watanabe
Ken Kumagaya
Yoichiro Ishii
Tsubura Ishii
George Hayashi
Nobuko Shiono
Tomoaki Ikeda
Osaka Fetal Cardiology Group
Publikationsdatum
23.04.2020
Verlag
Springer US
Erschienen in
Pediatric Cardiology / Ausgabe 5/2020
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-020-02346-7

Weitere Artikel der Ausgabe 5/2020

Pediatric Cardiology 5/2020 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.