Aim

The purpose of this study is to identify the effect of Nd: YAG laser posterior capsulotomy using an anterior chamber morphology.

Methods

This study included 42 eyes of 33 pseudophakic patients with visually significant PCO after uncomplicated cataract surgery. Exclusion criteria were complications related to cataract surgery, corneal pathology, pseudoexfoliation, glaucoma, uveitis, previous ocular surgery or trauma, and posterior segment pathology. All patients underwent routine ophthalmic examinations. The AS-OCT measurements were performed using NIDEK RS-3000 Lite retinal scan with anterior segment module. The anterior chamber depth (ACD) was measured by Monitor A&B Scan biometer. Nd: YAG laser posterior capsulotomy was done in a single session by the circular pattern with rupture of vitreous strands. Anterior chamber depth (ACD), central corneal thickness (CCT), and intraocular pressure (IOP) were measured. Anterior chamber angle (ACA), angle opening distances (AOD) at 500 mm (AOD500), AOD at 750 mm (AOD750), trabecular-iris space area at 500 (TISA 500), and TISA at 750 (TISA 750) were measured both nasally and temporally.

Results

The mean patient age was 55.56 ± 6.33 years. There were non-significant changes in IOP, ACD, and CCT with P values 0.395, 0.153, and 0.541, respectively. ACA, AOD500, AOD750, TISA 500, and TISA 750 highly significantly increased with P value < 0.001 for all.

Conclusion

Nd: YAG laser posterior capsulotomy with the circular pattern with vitreous strand cut technique is a safe technique for laser posterior capsulotomy.
Literatur
1.
Zurück zum Zitat Hu CY, Woung LC, Wang MC, Jian JH (2000) Influence of laser posterior capsulotomy on anterior chamber depth, refraction, and intraocular pressure. J Cataract Refract Surg 26:1183–1189CrossRefPubMed Hu CY, Woung LC, Wang MC, Jian JH (2000) Influence of laser posterior capsulotomy on anterior chamber depth, refraction, and intraocular pressure. J Cataract Refract Surg 26:1183–1189CrossRefPubMed
2.
Zurück zum Zitat Eliaçık M, Bayramlar H, Erdur SK, Demirci G, Gülkılık G (2014) Anterior segment optical coherence tomography measurement after neodymium yttrium aluminum garnet laser capsulotomy. J Ophthalmol 158:994–998 Eliaçık M, Bayramlar H, Erdur SK, Demirci G, Gülkılık G (2014) Anterior segment optical coherence tomography measurement after neodymium yttrium aluminum garnet laser capsulotomy. J Ophthalmol 158:994–998
3.
Zurück zum Zitat Pekel G, Yagcı R, Acer S, Özdemir S, Sayin N (2014) Evaluation of the impact of Nd: YAG laser posterior capsulotomy on ocular pulse amplitude and anterior segment morphology. Lasers Surg Med 46(7):553–557CrossRefPubMed Pekel G, Yagcı R, Acer S, Özdemir S, Sayin N (2014) Evaluation of the impact of Nd: YAG laser posterior capsulotomy on ocular pulse amplitude and anterior segment morphology. Lasers Surg Med 46(7):553–557CrossRefPubMed
4.
Zurück zum Zitat Simsek A (2017) Biometric and intraocular pressure changes after Nd: YAG laser posterior capsulotomy. Eur Res J 3(2):140–144 Simsek A (2017) Biometric and intraocular pressure changes after Nd: YAG laser posterior capsulotomy. Eur Res J 3(2):140–144
5.
Zurück zum Zitat Ozkurt YB, Sengör T, Evciman T, Haboğlu M (2009) Refraction, intraocular pressure and anterior chamber depth changes after Nd: YAG laser treatment for posterior capsular opacification in pseudophakic eyes. Clin Exp Optom 92(5):412–415CrossRefPubMed Ozkurt YB, Sengör T, Evciman T, Haboğlu M (2009) Refraction, intraocular pressure and anterior chamber depth changes after Nd: YAG laser treatment for posterior capsular opacification in pseudophakic eyes. Clin Exp Optom 92(5):412–415CrossRefPubMed
6.
Zurück zum Zitat Oztas Z, Palamar M, Afrashi F, Yagci A (2015) The effects of Nd: YAG laser capsulotomy on anterior segment parameters in patients with posterior capsular opacification. Clin Exp Optom 98:168–171CrossRefPubMed Oztas Z, Palamar M, Afrashi F, Yagci A (2015) The effects of Nd: YAG laser capsulotomy on anterior segment parameters in patients with posterior capsular opacification. Clin Exp Optom 98:168–171CrossRefPubMed
7.
Zurück zum Zitat Min JK, An JH, Yim JH (2014) A new technique for Nd: YAG laser posterior capsulotomy. Int J Ophthalmol 7(2):345–349PubMedPubMedCentral Min JK, An JH, Yim JH (2014) A new technique for Nd: YAG laser posterior capsulotomy. Int J Ophthalmol 7(2):345–349PubMedPubMedCentral
8.
Zurück zum Zitat Zeki SM (1999) Inverted U’ strategy for short pulsed laser posterior capsulotomy. Acta Ophthalmol Scand 77(5):575–577CrossRefPubMed Zeki SM (1999) Inverted U’ strategy for short pulsed laser posterior capsulotomy. Acta Ophthalmol Scand 77(5):575–577CrossRefPubMed
9.
Zurück zum Zitat Shah SI, Shah SA, Rai P, Abbasi SA, Katpar NA (2016) First crack guided conservative posterior capsulotomy using neodymium: YAG laser. Pak J Ophthalmol 32(3):159–164 Shah SI, Shah SA, Rai P, Abbasi SA, Katpar NA (2016) First crack guided conservative posterior capsulotomy using neodymium: YAG laser. Pak J Ophthalmol 32(3):159–164
10.
Zurück zum Zitat Shani L, David R, Tessler Z, Rosen S, Schneck M, Yassur Y (1994) Intraocular pressure after neodymium : YAG laser treatments in the anterior segment. J Cataract Refract Surg 20:455–458CrossRefPubMed Shani L, David R, Tessler Z, Rosen S, Schneck M, Yassur Y (1994) Intraocular pressure after neodymium : YAG laser treatments in the anterior segment. J Cataract Refract Surg 20:455–458CrossRefPubMed
11.
Zurück zum Zitat Ari S, Cingü AK, Sahin A, Çinar Y, Çaça I (2012) The effects of Nd: YAG laser posterior capsulotomy on macular thickness, intraocular pressure, and visual acuity. Ophthalmic Surg Lasers Imaging 43:395–400CrossRefPubMed Ari S, Cingü AK, Sahin A, Çinar Y, Çaça I (2012) The effects of Nd: YAG laser posterior capsulotomy on macular thickness, intraocular pressure, and visual acuity. Ophthalmic Surg Lasers Imaging 43:395–400CrossRefPubMed
12.
Zurück zum Zitat Keates RH, Steinert RF, Puliafito CA, Maxwell SK (1984) Long-term follow-up of Nd: YAG laser posterior capsulotomy. The American Intra-Ocular Implant Society Journal 10:164–168CrossRef Keates RH, Steinert RF, Puliafito CA, Maxwell SK (1984) Long-term follow-up of Nd: YAG laser posterior capsulotomy. The American Intra-Ocular Implant Society Journal 10:164–168CrossRef
13.
Zurück zum Zitat Stark WJ, Worthen D, Holladay JT, Murray G (1985) Neodymium: YAG lasers: an FDA report. Ophthalmology 92:209–212CrossRefPubMed Stark WJ, Worthen D, Holladay JT, Murray G (1985) Neodymium: YAG lasers: an FDA report. Ophthalmology 92:209–212CrossRefPubMed
14.
Zurück zum Zitat Ge J, Wand M, Chiang R, Paranhos A, Shields B (2000) Long-term effect of Nd : YAG laser posterior capsulotomy on intraocular pressure. Arch Ophthalmol 118:1334–1337CrossRefPubMed Ge J, Wand M, Chiang R, Paranhos A, Shields B (2000) Long-term effect of Nd : YAG laser posterior capsulotomy on intraocular pressure. Arch Ophthalmol 118:1334–1337CrossRefPubMed
16.
Zurück zum Zitat Zaidi M, Askari SN (2004) Effect of Nd: YAG laser posterior capsulotomy on anterior chamber depth, intraocular pressure and refractive status. Asian J Ophthalm 5:2–5 Zaidi M, Askari SN (2004) Effect of Nd: YAG laser posterior capsulotomy on anterior chamber depth, intraocular pressure and refractive status. Asian J Ophthalm 5:2–5
17.
Zurück zum Zitat Findl O, Drexler W, Menapace R, Georgopoulos M, Rainer G, Hitzenberger CK, Fercher AF (1999) Changes in intraocular lens position after neodymium: YAG capsulotomy. J Cataract Refract Surg 25(5):659–662CrossRefPubMed Findl O, Drexler W, Menapace R, Georgopoulos M, Rainer G, Hitzenberger CK, Fercher AF (1999) Changes in intraocular lens position after neodymium: YAG capsulotomy. J Cataract Refract Surg 25(5):659–662CrossRefPubMed
18.
Zurück zum Zitat Thornval P, Naeser K (1995) Refraction and anterior chamber depth before and after neodymium: YAG laser treatment for posterior capsule opacification in pseudophakic eyes: a prospective study. J Cataract Refract Surg 21(4):457–460CrossRefPubMed Thornval P, Naeser K (1995) Refraction and anterior chamber depth before and after neodymium: YAG laser treatment for posterior capsule opacification in pseudophakic eyes: a prospective study. J Cataract Refract Surg 21(4):457–460CrossRefPubMed
19.
Zurück zum Zitat Wroblewska-Czajka E, Wylegała E (2008) Central corneal thickness measurement by optical coherence tomography after Nd: YAG capsulotomy in patients with posterior capsule opacity. Klin Ocz 110:259–264 Wroblewska-Czajka E, Wylegała E (2008) Central corneal thickness measurement by optical coherence tomography after Nd: YAG capsulotomy in patients with posterior capsule opacity. Klin Ocz 110:259–264
20.
Zurück zum Zitat Ruiz-Casas D, Barrancos C, Alio JL 2nd, Ruiz-Guerrero M, Munoz-Negrete FJ (2013) Effect of posterior neodymium: YAG capsulotomy. Safety evaluation of macular foveal thickness, intraocular pressure and endothelial cell loss in pseudophakic patients with posterior capsule opacification. Arch Soc Esp Oftalmol 88:415–422CrossRefPubMed Ruiz-Casas D, Barrancos C, Alio JL 2nd, Ruiz-Guerrero M, Munoz-Negrete FJ (2013) Effect of posterior neodymium: YAG capsulotomy. Safety evaluation of macular foveal thickness, intraocular pressure and endothelial cell loss in pseudophakic patients with posterior capsule opacification. Arch Soc Esp Oftalmol 88:415–422CrossRefPubMed
21.
Zurück zum Zitat Eliacik M, Erdur SK, Gulkilik G, Ozsutcu M, Aras C, Bayramlar H, Aslan CA (2015) Anterior segment optical coherence tomography assessment after laser capsulotomy in pseudophakic eyes with pseudoexfoliation. Eye Contact Lens:1–4 Eliacik M, Erdur SK, Gulkilik G, Ozsutcu M, Aras C, Bayramlar H, Aslan CA (2015) Anterior segment optical coherence tomography assessment after laser capsulotomy in pseudophakic eyes with pseudoexfoliation. Eye Contact Lens:1–4
Metadaten
Titel
The impact of Nd: YAG laser posterior capsulotomy by the use of “the circular pattern with vitreous strand cut” technique on anterior chamber parameters
verfasst von
Nermien Salah El-Dien Mohammed El-Haddad
Publikationsdatum
13.08.2018
Verlag
Springer London
Erschienen in
Lasers in Medical Science / Ausgabe 2/2019
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-018-2602-x

Weitere Artikel der Ausgabe 2/2019

Lasers in Medical Science 2/2019 Zur Ausgabe