Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 10/2016

06.05.2016 | Knee

The incidence of implant fractures after knee arthroplasty

verfasst von: Magdalena M. Gilg, Christian W. Zeller, Lukas Leitner, Andreas Leithner, Gerold Labek, Patrick Sadoghi

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 10/2016

Einloggen, um Zugang zu erhalten

Abstract

Purpose

This study aimed to evaluate the incidence of “implant” fractures after knee arthroplasty using clinical literature and worldwide arthroplasty registers. The hypothesis was that register datasets report higher rates of these rare complications than clinical studies.

Methods

Calculations were based on the pooled incidence of revision operations after fractures of knee arthroplasties, comparing clinical studies published in MEDLINE-listed journals and annual reports from worldwide arthroplasty registers in a structured literature analysis based on a standardized methodology.

Results

Twelve clinical studies and datasets from six worldwide registers were included. Rates of fractures of knee arthroplasties were reported from 0.2 to 2.5 % in clinical studies versus 0.02–0.17 % in worldwide arthroplasty registers.

Conclusions

Fractures of knee arthroplasty systems are rare complications, with clinical studies showing higher incidence rates than worldwide arthroplasty registries. Unicompartmental knee arthroplasty (UKA) implanted before 2000, constrained primary or revision constrained total knee arthroplasties, and patellar replacements showed the highest incidence of implant fracture. The results of this analysis can help clinicians to counsel patients on potential complications following knee arthroplasty.

Level of evidence

III.
Literatur
1.
Zurück zum Zitat Abernethy PJ, Robinson CM, Fowler RM (1996) Fracture of the metal tibial tray after Kinematic total knee replacement. A common cause of early aseptic failure. J Bone Jt Surg Br 78:220–225 Abernethy PJ, Robinson CM, Fowler RM (1996) Fracture of the metal tibial tray after Kinematic total knee replacement. A common cause of early aseptic failure. J Bone Jt Surg Br 78:220–225
2.
Zurück zum Zitat Ansari S, Newman JH, Ackroyd CE (1997) St. Georg sledge for medial compartment knee replacement. 461 arthroplasties followed for 4 (1–17) years. Acta Orthop Scand 68:430–434CrossRefPubMed Ansari S, Newman JH, Ackroyd CE (1997) St. Georg sledge for medial compartment knee replacement. 461 arthroplasties followed for 4 (1–17) years. Acta Orthop Scand 68:430–434CrossRefPubMed
3.
Zurück zum Zitat Ashraf T, Newman JH, Evans RL, Ackroyd CE (2002) Lateral unicompartmental knee replacement survivorship and clinical experience over 21 years. J Bone Jt Surg Br 84:1126–1130CrossRef Ashraf T, Newman JH, Evans RL, Ackroyd CE (2002) Lateral unicompartmental knee replacement survivorship and clinical experience over 21 years. J Bone Jt Surg Br 84:1126–1130CrossRef
5.
Zurück zum Zitat Bozic KJ, Kurtz SM, Lau E, Ong K, Chiu V, Vail TP, Rubash HE, Berry DJ (2010) The epidemiology of revision total knee arthroplasty in the United States. Clin Orthop Relat Res 468:45–51CrossRefPubMed Bozic KJ, Kurtz SM, Lau E, Ong K, Chiu V, Vail TP, Rubash HE, Berry DJ (2010) The epidemiology of revision total knee arthroplasty in the United States. Clin Orthop Relat Res 468:45–51CrossRefPubMed
7.
Zurück zum Zitat Crowe B, Payne A, Evangelista PJ, Stachel A, Phillips MS, Slover JD, Inneh IA, Iorio R, Bosco JA (2015) Risk factors for infection following total knee arthroplasty: a series of 3836 cases from one institution. J Arthroplasty 30:2275–2278CrossRefPubMed Crowe B, Payne A, Evangelista PJ, Stachel A, Phillips MS, Slover JD, Inneh IA, Iorio R, Bosco JA (2015) Risk factors for infection following total knee arthroplasty: a series of 3836 cases from one institution. J Arthroplasty 30:2275–2278CrossRefPubMed
8.
Zurück zum Zitat Dalury DF, Pomeroy DL, Gorab RS, Adams MJ (2013) Why are total knee arthroplasties being revised? J Arthroplasty 28:120–121CrossRefPubMed Dalury DF, Pomeroy DL, Gorab RS, Adams MJ (2013) Why are total knee arthroplasties being revised? J Arthroplasty 28:120–121CrossRefPubMed
9.
Zurück zum Zitat David HG, Bishay M, James ET (1998) Problems with the Rotaflex: a 10 year review of a rotating hinge prosthesis. J Arthroplasty 13:402–408CrossRefPubMed David HG, Bishay M, James ET (1998) Problems with the Rotaflex: a 10 year review of a rotating hinge prosthesis. J Arthroplasty 13:402–408CrossRefPubMed
10.
Zurück zum Zitat Deehan DJ, Murray JD, Birdsall PD, Pinder IM (2006) Quality of life after knee revision arthroplasty. Acta Orthop 77:761–766CrossRefPubMed Deehan DJ, Murray JD, Birdsall PD, Pinder IM (2006) Quality of life after knee revision arthroplasty. Acta Orthop 77:761–766CrossRefPubMed
11.
Zurück zum Zitat Doll R, Hill AB (1956) Lung cancer and other causes of death in relation to smoking; a second report on the mortality of British doctors. Br Med J 2:1071–1081CrossRefPubMedPubMedCentral Doll R, Hill AB (1956) Lung cancer and other causes of death in relation to smoking; a second report on the mortality of British doctors. Br Med J 2:1071–1081CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Friesenbichler J, Schwarzkopf R, Sadoghi P, Marwin SE, Glehr M, Maurer-Ertl W, Leithner A (2012) Failure rate of a rotating hinge knee design due to yoke fracture of the hinged tibial insert: a retrospective data analysis and review of the literature. Int Orthop 36:993–998CrossRefPubMed Friesenbichler J, Schwarzkopf R, Sadoghi P, Marwin SE, Glehr M, Maurer-Ertl W, Leithner A (2012) Failure rate of a rotating hinge knee design due to yoke fracture of the hinged tibial insert: a retrospective data analysis and review of the literature. Int Orthop 36:993–998CrossRefPubMed
14.
Zurück zum Zitat Furnes O, Espehaug B, Lie SA, Vollset SE, Engesaeter LB, Havelin LI (2002) Early failures among 7,174 primary total knee replacements: a follow-up study from the Norwegian Arthroplasty Register 1994–2000. Acta Orthop Scand 73:117–129CrossRefPubMed Furnes O, Espehaug B, Lie SA, Vollset SE, Engesaeter LB, Havelin LI (2002) Early failures among 7,174 primary total knee replacements: a follow-up study from the Norwegian Arthroplasty Register 1994–2000. Acta Orthop Scand 73:117–129CrossRefPubMed
15.
Zurück zum Zitat Hwang N, Grimer RJ, Carter SR, Tillman RM, Abudu A, Jeys LM (2012) Early results of a non-invasive extendible prosthesis for limb-salvage surgery in children with bone tumours. J Bone Jt Surg Br 94:265–269CrossRef Hwang N, Grimer RJ, Carter SR, Tillman RM, Abudu A, Jeys LM (2012) Early results of a non-invasive extendible prosthesis for limb-salvage surgery in children with bone tumours. J Bone Jt Surg Br 94:265–269CrossRef
17.
Zurück zum Zitat Lewold S, Robertsson O, Knutson K, Lidgren L (1998) Revision of unicompartmental knee arthroplasty: outcome in 1,135 cases from the Swedish Knee Arthroplasty study. Acta Orthop Scand 69:469–474CrossRefPubMed Lewold S, Robertsson O, Knutson K, Lidgren L (1998) Revision of unicompartmental knee arthroplasty: outcome in 1,135 cases from the Swedish Knee Arthroplasty study. Acta Orthop Scand 69:469–474CrossRefPubMed
18.
Zurück zum Zitat Manzotti A, Chemello C, Pullen C, Cerveri P, Confalonieri N (2013) An uncommon cause of cemented unicompartmental knee arthroplasty failure: fracture of metallic components. Knee Surg Sports Traumatol Arthrosc 21:2518–2522CrossRefPubMed Manzotti A, Chemello C, Pullen C, Cerveri P, Confalonieri N (2013) An uncommon cause of cemented unicompartmental knee arthroplasty failure: fracture of metallic components. Knee Surg Sports Traumatol Arthrosc 21:2518–2522CrossRefPubMed
20.
22.
Zurück zum Zitat Panousis K, Murnaghan C, Koettig P, Grigoris P (2004) Fracture of the femoral component of a Brigham unicompartmental knee: a case report. Knee Surg Sports Traumatol Arthrosc 12:307–310CrossRefPubMed Panousis K, Murnaghan C, Koettig P, Grigoris P (2004) Fracture of the femoral component of a Brigham unicompartmental knee: a case report. Knee Surg Sports Traumatol Arthrosc 12:307–310CrossRefPubMed
23.
Zurück zum Zitat Robertsson O (2007) Knee arthroplasty registers. J Bone Jt Surg Br 89:1–4CrossRef Robertsson O (2007) Knee arthroplasty registers. J Bone Jt Surg Br 89:1–4CrossRef
24.
Zurück zum Zitat Sadoghi P, Pawelka W, Liebensteiner MC, Williams A, Leithner A, Labek G (2014) The incidence of implant fractures after total hip arthroplasty. Int Orthop 38:39–46CrossRefPubMed Sadoghi P, Pawelka W, Liebensteiner MC, Williams A, Leithner A, Labek G (2014) The incidence of implant fractures after total hip arthroplasty. Int Orthop 38:39–46CrossRefPubMed
25.
Zurück zum Zitat Sadoghi P, Liebensteiner M, Agreiter M, Leithner A, Bohler N, Labek G (2013) Revision surgery after total joint arthroplasty: a complication-based analysis using worldwide arthroplasty registers. J Arthroplasty 28:1329–1332CrossRefPubMed Sadoghi P, Liebensteiner M, Agreiter M, Leithner A, Bohler N, Labek G (2013) Revision surgery after total joint arthroplasty: a complication-based analysis using worldwide arthroplasty registers. J Arthroplasty 28:1329–1332CrossRefPubMed
26.
Zurück zum Zitat Schuh R, Neumann D, Rauf R, Hofstaetter J, Boehler N, Labek G (2012) Revision rate of Birmingham Hip Resurfacing arthroplasty: comparison of published literature and arthroplasty register data. Int Orthop 36:1349–1354CrossRefPubMedPubMedCentral Schuh R, Neumann D, Rauf R, Hofstaetter J, Boehler N, Labek G (2012) Revision rate of Birmingham Hip Resurfacing arthroplasty: comparison of published literature and arthroplasty register data. Int Orthop 36:1349–1354CrossRefPubMedPubMedCentral
27.
Zurück zum Zitat Skou ST, Roos EM, Laursen MB, Rathleff MS, Arendt-Nielsen L, Simonsen O, Rasmussen S (2015) A randomized, controlled trial of total knee replacement. N Engl J Med 373:1597–1606CrossRefPubMed Skou ST, Roos EM, Laursen MB, Rathleff MS, Arendt-Nielsen L, Simonsen O, Rasmussen S (2015) A randomized, controlled trial of total knee replacement. N Engl J Med 373:1597–1606CrossRefPubMed
28.
Zurück zum Zitat Smith TH, Gad BV, Klika AK, Styron JF, Joyce TA, Barsoum WK (2013) Comparison of mechanical and nonmechanical failure rates associated with rotating hinged total knee arthroplasty in nontumor patients. J Arthroplasty 28(62–7):e1 Smith TH, Gad BV, Klika AK, Styron JF, Joyce TA, Barsoum WK (2013) Comparison of mechanical and nonmechanical failure rates associated with rotating hinged total knee arthroplasty in nontumor patients. J Arthroplasty 28(62–7):e1
29.
Zurück zum Zitat Springer BD, Sim FH, Hanssen AD, Lewallen DG (2004) The modular segmental kinematic rotating hinge for nonneoplastic limb salvage. Clin Orthop Relat Res 421:181–187CrossRefPubMed Springer BD, Sim FH, Hanssen AD, Lewallen DG (2004) The modular segmental kinematic rotating hinge for nonneoplastic limb salvage. Clin Orthop Relat Res 421:181–187CrossRefPubMed
30.
Zurück zum Zitat Steele RG, Hutabarat S, Evans RL, Ackroyd CE, Newman JH (2006) Survivorship of the St Georg Sled medial unicompartmental knee replacement beyond ten years. J Bone Jt Surg Br 88:1164–1168CrossRef Steele RG, Hutabarat S, Evans RL, Ackroyd CE, Newman JH (2006) Survivorship of the St Georg Sled medial unicompartmental knee replacement beyond ten years. J Bone Jt Surg Br 88:1164–1168CrossRef
31.
Zurück zum Zitat Swamy GN, Quah C, Bagouri E, Badhe NP (2014) Nontraumatic fracture of the femoral condylar prosthesis in a total knee arthroplasty leading to mechanical failure. Case Rep Orthop 2014:896348PubMedPubMedCentral Swamy GN, Quah C, Bagouri E, Badhe NP (2014) Nontraumatic fracture of the femoral condylar prosthesis in a total knee arthroplasty leading to mechanical failure. Case Rep Orthop 2014:896348PubMedPubMedCentral
32.
Zurück zum Zitat Thiele K, Perka C, Matziolis G, Mayr HO, Sostheim M, Hube R (2015) Current failure mechanisms after knee arthroplasty have changed: polyethylene wear is less common in revision surgery. J Bone Jt Surg Am 97:715–720CrossRef Thiele K, Perka C, Matziolis G, Mayr HO, Sostheim M, Hube R (2015) Current failure mechanisms after knee arthroplasty have changed: polyethylene wear is less common in revision surgery. J Bone Jt Surg Am 97:715–720CrossRef
33.
Zurück zum Zitat Unwin PS, Cobb JP, Walker PS (1993) Distal femoral arthroplasty using custom-made prostheses. The first 218 cases. J Arthroplasty 8:259–268CrossRefPubMed Unwin PS, Cobb JP, Walker PS (1993) Distal femoral arthroplasty using custom-made prostheses. The first 218 cases. J Arthroplasty 8:259–268CrossRefPubMed
34.
Zurück zum Zitat Vessely MB, Whaley AL, Harmsen WS, Schleck CD, Berry DJ (2006) The Chitranjan Ranawat Award: long-term survivorship and failure modes of 1000 cemented condylar total knee arthroplasties. Clin Orthop Relat Res 452:28–34CrossRefPubMed Vessely MB, Whaley AL, Harmsen WS, Schleck CD, Berry DJ (2006) The Chitranjan Ranawat Award: long-term survivorship and failure modes of 1000 cemented condylar total knee arthroplasties. Clin Orthop Relat Res 452:28–34CrossRefPubMed
35.
Zurück zum Zitat Wang H, Lou H, Zhang H, Jiang J, Liu K (2014) Similar survival between uncemented and cemented fixation prostheses in total knee arthroplasty: a meta-analysis and systematic comparative analysis using registers. Knee Surg Sports Traumatol Arthrosc 22:3191–3197CrossRefPubMed Wang H, Lou H, Zhang H, Jiang J, Liu K (2014) Similar survival between uncemented and cemented fixation prostheses in total knee arthroplasty: a meta-analysis and systematic comparative analysis using registers. Knee Surg Sports Traumatol Arthrosc 22:3191–3197CrossRefPubMed
36.
Zurück zum Zitat Whiteside LA, Fosco DR, Brooks JG Jr (1993) Fracture of the femoral component in cementless total knee arthroplasty. Clin Orthop Relat Res 286:71–77PubMed Whiteside LA, Fosco DR, Brooks JG Jr (1993) Fracture of the femoral component in cementless total knee arthroplasty. Clin Orthop Relat Res 286:71–77PubMed
Metadaten
Titel
The incidence of implant fractures after knee arthroplasty
verfasst von
Magdalena M. Gilg
Christian W. Zeller
Lukas Leitner
Andreas Leithner
Gerold Labek
Patrick Sadoghi
Publikationsdatum
06.05.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 10/2016
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-016-4160-8

Weitere Artikel der Ausgabe 10/2016

Knee Surgery, Sports Traumatology, Arthroscopy 10/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.