Skip to main content
Erschienen in: Acta Neurochirurgica 8/2010

Open Access 01.08.2010 | Clinical Article

The influence of transcutaneous electrical neurostimulation (TENS) on human cerebral blood flow velocities

verfasst von: Mark ter Laan, J. Marc C. van Dijk, Jan-Willem J. Elting, Vaclav Fidler, Michiel J. Staal

Erschienen in: Acta Neurochirurgica | Ausgabe 8/2010

Abstract

Background

It has been shown that transcutaneous electrical neurostimulation (TENS) reduces sympathetic tone. Spinal cord stimulation (SCS) has proven qualities to improve coronary, peripheral, and cerebral blood circulation. Therefore, we postulate that TENS and SCS affect the autonomic nervous system in analogous ways. In this line of thought, cervical application of TENS might be a useful and simple adjunct in the treatment of cerebrovascular disease by improving cerebral blood flow. Experiments were performed in order to assess whether cervical TENS is safe and whether an effect on cerebral blood flow velocity (CBFV) can be shown in healthy subjects.

Method

A controlled, non-randomized, phase 1 study was performed with 20 healthy volunteers. Cervical TENS was applied in several frequencies, with and without hyperventilation. Continuous registration of blood pressure, pulse, CBFV (estimated by transcranial Doppler sonography) and end-tidal carbon dioxide concentration was performed.

Findings

Cervical TENS was well-tolerated by all subjects. Despite small effects on heart rate (HR) and mean arterial blood pressure (MAP), a significant effect on middle cerebral artery (MCA) blood flow velocity was not demonstrated. No effect of age, gender, current or session order on MCA, HR, or MAP was found. TENS did not influence the effect of hyperventilation.

Conclusions

In these experiments, application of cervical TENS is proven to be a safe procedure. However, no effects on cerebral blood flow velocity could be detected, perhaps due to the intact cerebral autoregulation in the healthy volunteers.
Hinweise

Comment

This study seeks to evaluate the efficacy and application of electromagnetic fields to modulate and treat cerebrovascular disease. The device of choice was the transcutaneous electrical neurostimulator (TENS); the end-point followed was cerebral blood flow in the middle cerebral artery, as measured by transcranial doppler ultrasonography. Within the 20 patients examined, no significant difference in outcomes was noted.
While simple, this paper provides a vital critique of popular mode of treatment. The use of electromagnetic and other non-invasive techniques to modify physiology has been proposed for over a century. More and more we see variations on this in products from industry designed to treat diseases without pills or surgery. The pursuit of non-invasive therapies is wonderful, but this article reminds us of the need to be rational and critical in our evaluation of novel therapies.
Markus Bookland, MD
Christopher M. Loftus MD
Philadelphia, USA

Introduction

Spinal cord stimulation (SCS) is widely used in the treatment of pain. Although several mechanisms have been proposed, its exact mechanism of action remains unclear [13]. At least part of the effects of SCS is mediated by the autonomic nervous system, as shown by the fact that sympathetically mediated pain (e.g., visceral pain and complex regional pain syndromes) responds better than nociceptive pain to SCS treatment [13]. In addition, it has been demonstrated that SCS has autonomic (side)effects, such as increasing peripheral blood flow in Raynaud's phenomenon, peripheral ischemic pain, coronary disease, and complex regional pain syndromes [4, 11, 13]. Since the sympathetic fibers are located ventrally in the spinal cord and SCS electrodes are placed dorsally, these ventral fibers are not located within the electrical field. Therefore, these autonomic effect must be indirect, e.g., via antidromic pathways [13].
Transcutaneous electrical neurostimulation (TENS) has been used since 1974 to test the tolerance for stimuli in the work-up for SCS [1]. Some of the effects seen in SCS can be produced by TENS as well. Effects on peripheral blood flow have been shown, as well as increased coronary perfusion [12]. An experiment on autonomic cardiovascular reflexes demonstrated a decreased sympathetic response when using TENS [17]. Since the sympathetic effects as shown by SCS must be indirect effects of the electrical stimulation, we postulate that TENS produces these effects in the same way.
In several studies, an increase of cerebral blood flow (CBF) has been described as a result of cervical SCS [2, 3, 9, 10]. The effects of SCS on CBF are most likely mediated through the sympathetic nervous system, since cerebral vasculature is highly sympathetically innervated and the vascular diameter is related to sympathetic tone [18]. Patel showed that this effect is mediated via a central pathway [15]. This pathway involves brainstem vasomotor centers that connect with the cerebral microvasculature through intrinsic nerve pathways. In experiments on rats, he showed that surgical sympathectomy failed to influence the CBF response caused by cervical SCS, while transsection of the spinal cord at the cervicomedullary junction completely abolished all increases in CBF. Taking into account the proven effect of TENS on peripheral blood flow and its (indirect) effect on sympathetic tone, TENS should be able to alter CBF, an analog to SCS. As such, TENS could be a useful non-invasive adjunct in the treatment of cerebrovascular disease (CVD).
TENS either has a direct effect on vascular diameter or has an effect on the sympathetic tone. If the latter is true, then, in resting conditions, there should be no effect on CBF. Therefore, in order to find out whether the sympathetic tone is reduced by TENS, the effects of TENS on CBF in hyperventilating subjects is of interest. Given that cerebral blood flow in response to hyperventilation might partially be sympathetically mediated [7, 8], this response should be reduced by TENS.
As cervical TENS is a novel potential therapeutic application in the treatment of CVD, this paper describes the experiments that were performed to assess the effects of TENS on CBF in healthy subjects and to register its potential side effects.

Materials and methods

Study design

The study was designed as a controlled (subjects were their own controls), non-randomized phase 1 experiment. Healthy volunteers were recruited from the general public by advertisement in the local newspapers. Cerebral blood flow velocity (CBFV) can be seen as a representation of CBF when the vascular cross-sectional area (CSA) remains constant (CBFV=CBF/CSA). Cerebral blood flow velocity was measured by transcranial Doppler (TCD) of the medial cerebral artery (MCA). The trial has been authorized by the local Research Ethical Board and the Dutch Central Commission of Human Research.

Sample size calculation

The literature reports inter-individual standard deviation of flow velocities as about 15% [21] and the intra-individual standard deviation as 8% [14]. Sample size calculation is based on the requirement that a difference in flow velocities of 20 cm/s (ca 20%) between frequencies 2 and 120 Hz should be detected with a probability (power) of 90% when testing at a significance level of 5% two-sided. This results in a sample size of 20.

Treatment of subjects

The subjects were treated with conventional TENS, providing a continuous flow of symmetrical rectangular biphasic pulses (Schwa Medico, Pierenkemper GMBH; Wetzlarestr. 41-43, D-35630, Ehringhausen, Germany). Stimulation was performed at 90% of the highest tolerated current, with a pulse-width of 200 ms. Stimulation frequencies were 2, 20, 50, 100, and 120 Hz. In this way, the entire range of possible TENS frequencies and the most used frequencies in current TENS treatments were captured. Subjects were supine during the entire experiment. The TENS electrodes were applied cervical at the height of the mandible on both sides of the nuchal ligament (dermatome C2-C3). Doppler probes were applied to the skull for continuous registration of flow velocity in the MCA (left and right). Continuous registration of pulse and blood pressure was recorded by plethysmography.
For the first experiment (Fig. 1), five blocks of measurements took place for each TENS frequency, 5 min of registration without TENS, and followed by 5 min with TENS (so each TENS frequency had its own control-baseline). The order of frequencies was randomized (using the QuickCalcs online calculator, GraphPad Software, Inc.) in order to correct for possible alteration in time of the sympathetic tone during the experiment.
The second experiment (Fig. 2) was designed to examine whether TENS influences the normal cerebral regulation that physiologically occurs in reaction to hyperventilation. In the same way as the first experiment, blocks of measurements were recorded, now at a fixed frequency of 100 Hz. For practical purposes, only one frequency was used for this experiment. The frequency of 100 Hz was chosen because it has been used in previous TENS experiments to alter blood flow in coronary arteries [5]. During this part of the experiment, end-tidal partial carbon dioxide concentration (ETCO2) was measured in the exhaled air as a measure of hyperventilation. Hyperventilation was defined as a decrease of ETCO2 to 2%. Measurements were performed following the scheme below (in half of the subjects the order was reversed, i.e., first TENS with hyperventilation):
  • Three minutes registration with hyperventilation (1 min to achieve an ETCO2 of 2%, 2 min measurement)
  • Ten minutes registration without TENS/hyperventilation
  • Three minutes registration with TENS and hyperventilation (1 min to achieve an ETCO2 of 2%, 2 min measuring)
  • Ten minutes registration without TENS or until baseline variables were approached

Data processing

Data was collected using a continuous TCD monitor (DIGI-LITEtm, Raanana, Israel), a plethysmograph for assessing blood pressure and pulse (Finometer-Pro, Finapress Medical Systems, Amsterdam, The Netherlands), an electrocardiograph (Finometer-Pro, Finapress Medical Systems, Amsterdam, The Netherlands), and a capnograph (Capnomac Ultima, GE Healthcare, Chalfont St Giles, UK). All analog output was routed to a computer via a digitizer. The data were continuously registered using Neuromon (incorporating Labview 7.1, National Instruments) software. Before statistical analysis, all artifacts were deleted from the data streams (e.g., reduced Doppler signal due to transducer dislodgement). In order to clean the data from noise, filtering was performed using in-house written routines in the Matlab environment (The Math Works, Inc., Natwick, MA, USA, Matlab 6.5). Bandwidths for the data were defined (50–150 bpm for HR, 5–100 cm/s for MCA, 60–180 mmHg for ABP, and 2–6% for CO2 in resting phase), and top and bottom 10% of data were deleted, replacing those by linear interpolation. Next, 3-min data streams were taken from each measurement, in each case a stream from −4 to −1 min before the start of TENS and a stream from +1 to +4 min after the start of TENS. From the hyperventilation data, a stream was taken from −2.5 to −0.5 min from the start of HV and another 2-min stream as soon as ETCO2 had stabilized around 2–2.5% (app. 15–20 mmHg). Average values of all streams were calculated and used for statistical analysis.

Statistical analysis

The purpose of the analysis was to find out (1) the effect of different TENS frequencies on cerebral blood flow and (2) whether the TENS frequency of 100 Hz modifies the effect of hyperventilation on cerebral blood flow. The data from the first experiment were used to address the first question and the data from the second experiment to address the second question. For each TENS frequency, we subtracted the measurement at the preceding non-TENS session from the measurement with TENS and used these “baseline-corrected” differences as basic outcomes in the analysis. We used all observations from the MCA side which had the highest blood flow velocity at baseline as measured by TCD. For both questions, the analysis consisted of fitting mixed effects regression models to the data [16]. For question 1, we have used the TENS frequency (at five levels), the order of observations, age, and gender of the participants as fixed effect explanatory variables. For question 2, the fixed effects were TENS frequency (0 or 100), ETCO2, age, and gender. Statistical tests were carried out at 5% level of significance. We used the statistical package R for computations (version 2.8.1; library nlme).

Results

A group of 11 females and nine males, all healthy subjects, completed the experiment, in age ranging from 25 to 65 years (median 46.5 years). Two more volunteers participated, but their measurements failed. In one individual, the temporal bony windows were insufficient to obtain adequate MCA signals. In the other, an exceptional amount of noise was perceived on all signals; therefore, the experiment was aborted.
All volunteers tolerated TENS well, though the highest tolerated current did vary from 10 to 35 mA. The only adverse events reported by the volunteers were pressure from the cap used to position the TCD probes and tingling sensations or dizziness as a result of the hyperventilation. All volunteers reached the predefined threshold of an ETCO2 of 2% during hyperventilation.
Figure 3a shows box plots with values of MCA blood flow velocities, blood pressures (MAP), and pulse (HR) without TENS and per TENS frequency for the first experiment. Box plots in Fig. 3b show differences between MCA blood flow velocities, MAPs and HR, and their coupled baseline values. The mean differences and the corresponding confidence intervals for MCA, HR, and MAP are shown in Table 1. The effect of TENS on MCA was on average 0.78 cm/s (95% CI; 0.06 to 1.50), the effects at different TENS frequencies were not statistically significantly different (P = 0.80). For HR and MAP, too, the effects of different TENS frequencies did not differ (P = 0.06 and P = 0.14, respectively). Compared with the baseline, the HR was significantly lower at 120 Hz, and the MAP was significantly higher at 2, 50, and 100 Hz. However, the effects are so small, that they cannot be judged clinically relevant. No effect of age, gender, or session order on MCA, HR, or MAP was found.
Table 1
Differences of MCA blood flow velocities (MCA), heart rates (HR), and mean arterial blood pressures (MAP) for each TENS frequency compared with their coupled baseline values
 
MCA
 
HR
 
MAP
 
Frequency
Effect
95% CI
Effect
95% CI
Effect
95% CI
2 Hz
1.019
(−0.277, 2.315)
−0.233
(−1.410, 0.944)
2.133a
(0.720, 3.547)
20 Hz
0.399
(−0.897, 1.695)
−0.453
(−1.750, 0.844)
0.876
(−0.570, 2.322)
50 Hz
1.247
(−0.049, 2.543)
−0.116
(−1.369, 1.137)
2.565a
(1.152, 3.979)
100 Hz
0.874
(−0.423, 2.170)
0.713
(−0.500, 1.927)
2.180a
(0.766, 3.593)
120 Hz
0.347
(−0.931, 1.661)
−1.844a
(−3.057, −0.631)
0.668
(−0.778, 2.115)
Overall
0.781
(0.060, 1.501)
−0.390
(−0.971,0.191)
1.708
(0.825,2.591)
aSignificant effect
Figure 4a, b show box plots of values of MCA blood flow, blood pressure, and pulse for experiment 2: with and without TENS, and with and without hyperventilation. No significant effect of TENS on MCA, HR, or MAP on the effect of hyperventilation was detected (P values 0.43, 0.58, 0.31, respectively). ETC02 (difference between the measurements with and without hyperventilation) was found to be positively related to MCA and negatively to HR (P < 0.001).
Because the highest tolerated current varied between volunteers from 10 to 35 mA, we have also included the current in the fixed-effects model. No statistically significant effects of current could be found.

Discussion

We have studied whether TENS can influence the cerebral blood flow in healthy subjects. We postulated that TENS might influence cerebral blood flow via sympathetic pathways as observed in experiments with SCS [2, 3, 6, 911, 13, 15]. Also, TENS has been shown to increase locoregional blood flow and sympathetic tone [12, 17].
The purpose of this study was twofold: (1) to find out if the use of cervically applied TENS is safe and (2) to find out the effect on CBF in healthy subjects.
We suggested TENS might either (indirectly) create a sympathetic response that influences CBF or TENS might alter the sympathetic tone. To test the first way of action, we performed experiment 1 in which CBF was measured during stimulation with several TENS frequencies in resting healthy subjects. If only sympathetic tone is influenced by TENS, subjects in rest will not show an effect, but subjects that have to apply their autonomous nervous system might. Because the cerebral response to carbon dioxide changes might be partially sympathetically mediated [7, 8], we have also tested whether TENS influences the response to hyperventilation.
Because sympathetic tone can easily change during an experiment (an individual can become either more or less comfortable during the experiment), we have applied several measures to compensate for this effect. Firstly, we have randomized the order of applied TENS frequencies; secondly we have provided each frequency with its own control-baseline-measurement, and thirdly, the order of TENS with/without hyperventilation varied.
TENS was tolerated very well by all subjects. No adverse events were found. Also, systemic blood pressure and heart rate were not affected by TENS in a clinically relevant manner.
As for the effect of TENS on CBF, no statistically significant effects were found for the individual TENS frequencies, neither at rest nor in the hyperventilation experiment. Overall, there was a small increase of MCA blood flow velocity (0.78 cm/s) when TENS is compared with rest. The fall in MCA blood flow velocity as a result of hyperventilation was a little less prominent when TENS was applied, but this did not reach statistical significance.
Several explanations can be advanced as to why no effect was found. Firstly, of course, there might be no effect at all. Secondly, TENS might not be powerful enough because subjects can only tolerate a certain amount of current. However, we did not find a difference between volunteers that tolerated higher and volunteers that tolerated lower currents. Thirdly, we have only used one frequency in the hyperventilation experiment; possibly, other frequencies give different results. Fourthly, one might have to apply TENS for a longer period, although we do not think this is plausible, given the results of other TENS studies. Finally, regulatory mechanisms of CBF are complex. CBF depends on several parameters including MAP, ICP, CO2, O2, and other (auto)regulatory mechanisms. The role of the sympathetic nervous system on these parameters remains unclear. Sympathetic tone does regulate MAP by means of peripheral vasoconstriction in organ beds, but there is ongoing debate about the sympathetic effects on cerebral vasculature [19, 20]. Also, the effects of CO2 might be far stronger than the sympathetic effects; possibly, sympathetic tone only has a modulating effect [8]. Moreover, the study was performed in healthy subjects with a powerful, intact autoregulation. This might have masked the effects of TENS on sympathetic tone.
The power analysis was aimed at finding a clinically significant effect; thus, with our experiments, we can only conclude that there seems to be no such effect in a healthy population. This does not yet prove that TENS does not influence the sympathetic nervous system and CBF, especially because we did notice a tendency towards less decreased blood flow velocities in reaction to hyperventilation when TENS was applied.
Possibly, an effect of TENS is appreciated in patients with disturbed autoregulation, e.g., patients with cerebral ischemia or following subarachnoid hemorrhage (with locally disturbed blood–brain barrier). Since cervical TENS did not have a clinically relevant effect on systemic blood pressure and heart rate, TENS can be safely applied to those patients. We think it is important to further investigate the effect of TENS on CBF in the presence of a disturbed autoregulation, especially since the influence of sympathetic tone is possibly much more significant in these pathological situations.

Open Access

This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
Open AccessThis is an open access article distributed under the terms of the Creative Commons Attribution Noncommercial License (https://​creativecommons.​org/​licenses/​by-nc/​2.​0), which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.

Comment

This study seeks to evaluate the efficacy and application of electromagnetic fields to modulate and treat cerebrovascular disease. The device of choice was the transcutaneous electrical neurostimulator (TENS); the end-point followed was cerebral blood flow in the middle cerebral artery, as measured by transcranial doppler ultrasonography. Within the 20 patients examined, no significant difference in outcomes was noted.
While simple, this paper provides a vital critique of popular mode of treatment. The use of electromagnetic and other non-invasive techniques to modify physiology has been proposed for over a century. More and more we see variations on this in products from industry designed to treat diseases without pills or surgery. The pursuit of non-invasive therapies is wonderful, but this article reminds us of the need to be rational and critical in our evaluation of novel therapies.
Markus Bookland, MD
Christopher M. Loftus MD
Philadelphia, USA

Unsere Produktempfehlungen

Die Chirurgie

Print-Titel

Das Abo mit mehr Tiefe

Mit der Zeitschrift Die Chirurgie erhalten Sie zusätzlich Online-Zugriff auf weitere 43 chirurgische Fachzeitschriften, CME-Fortbildungen, Webinare, Vorbereitungskursen zur Facharztprüfung und die digitale Enzyklopädie e.Medpedia.

Bis 30. April 2024 bestellen und im ersten Jahr nur 199 € zahlen!

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Neurologie & Psychiatrie

Kombi-Abonnement

Mit e.Med Neurologie & Psychiatrie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

Weitere Produktempfehlungen anzeigen
Literatur
1.
Zurück zum Zitat Burton C (1974) Instrumentation for dorsal column stimulator implantation. Surg Neurol 2(1):39–40PubMed Burton C (1974) Instrumentation for dorsal column stimulator implantation. Surg Neurol 2(1):39–40PubMed
2.
Zurück zum Zitat Clavo B, Robaina F, Catala L, Perez JL, Lloret M, Carames MA, Morera J, Lopez L, Suarez G, Macias D, Rivero J, Hernandez MA (2004) Effect of cervical spinal cord stimulation on regional blood flow and oxygenation in advanced head and neck tumours. Ann Oncol 15(5):802–807PubMedCrossRef Clavo B, Robaina F, Catala L, Perez JL, Lloret M, Carames MA, Morera J, Lopez L, Suarez G, Macias D, Rivero J, Hernandez MA (2004) Effect of cervical spinal cord stimulation on regional blood flow and oxygenation in advanced head and neck tumours. Ann Oncol 15(5):802–807PubMedCrossRef
3.
Zurück zum Zitat Clavo B, Robaina F, Catala L, Valcarcel B, Morera J, Carames MA, Ruiz-Egea E, Panero F, Lloret M, Hernandez MA (2003) Increased locoregional blood flow in brain tumors after cervical spinal cord stimulation. J Neurosurg 98(6):1263–1270PubMedCrossRef Clavo B, Robaina F, Catala L, Valcarcel B, Morera J, Carames MA, Ruiz-Egea E, Panero F, Lloret M, Hernandez MA (2003) Increased locoregional blood flow in brain tumors after cervical spinal cord stimulation. J Neurosurg 98(6):1263–1270PubMedCrossRef
4.
Zurück zum Zitat Cook AW, Oygar A, Baggenstos P, Pacheco S, Kleriga E (1976) Vascular disease of extremities. Electric stimulation of spinal cord and posterior roots. N Y State J Med 76(3):366–368PubMed Cook AW, Oygar A, Baggenstos P, Pacheco S, Kleriga E (1976) Vascular disease of extremities. Electric stimulation of spinal cord and posterior roots. N Y State J Med 76(3):366–368PubMed
5.
Zurück zum Zitat De Vries J, Anthonio RL, DeJongste MJ, Jessurun GA, Tan ES, de Smet BJ, van den Heuvel AF, Staal MJ, Zijlstra F (2007) The effect of electrical neurostimulation on collateral perfusion during acute coronary occlusion. BMC Cardiovasc Disord 7:18PubMedCrossRef De Vries J, Anthonio RL, DeJongste MJ, Jessurun GA, Tan ES, de Smet BJ, van den Heuvel AF, Staal MJ, Zijlstra F (2007) The effect of electrical neurostimulation on collateral perfusion during acute coronary occlusion. BMC Cardiovasc Disord 7:18PubMedCrossRef
6.
Zurück zum Zitat Hautvast RW, Ter Horst GJ, DeJong BM, DeJongste MJ, Blanksma PK, Paans AM, Korf J (1997) Relative changes in regional cerebral blood flow during spinal cord stimulation in patients with refractory angina pectoris. Eur J Neurosci 9(6):1178–1183PubMedCrossRef Hautvast RW, Ter Horst GJ, DeJong BM, DeJongste MJ, Blanksma PK, Paans AM, Korf J (1997) Relative changes in regional cerebral blood flow during spinal cord stimulation in patients with refractory angina pectoris. Eur J Neurosci 9(6):1178–1183PubMedCrossRef
7.
Zurück zum Zitat Jordan J, Shannon JR, Black BK, Paranjape SY, Barwise J, Robertson D (1998) Raised cerebrovascular resistance in idiopathic orthostatic intolerance: evidence for sympathetic vasoconstriction. Hypertension 32(4):699–704PubMed Jordan J, Shannon JR, Black BK, Paranjape SY, Barwise J, Robertson D (1998) Raised cerebrovascular resistance in idiopathic orthostatic intolerance: evidence for sympathetic vasoconstriction. Hypertension 32(4):699–704PubMed
8.
Zurück zum Zitat Jordan J, Shannon JR, Diedrich A, Black B, Costa F, Robertson D, Biaggioni I (2000) Interaction of carbon dioxide and sympathetic nervous system activity in the regulation of cerebral perfusion in humans. Hypertension 36(3):383–388PubMed Jordan J, Shannon JR, Diedrich A, Black B, Costa F, Robertson D, Biaggioni I (2000) Interaction of carbon dioxide and sympathetic nervous system activity in the regulation of cerebral perfusion in humans. Hypertension 36(3):383–388PubMed
9.
Zurück zum Zitat Karadag O (2005) Cervical spinal cord stimulation increases cerebral cortical blood flow in an experimental cerebral vasospasm model. Acta Neurochir (Wien ) 147(1):79–84CrossRef Karadag O (2005) Cervical spinal cord stimulation increases cerebral cortical blood flow in an experimental cerebral vasospasm model. Acta Neurochir (Wien ) 147(1):79–84CrossRef
10.
Zurück zum Zitat Lee JY, Huang DL, Keep R, Sagher O (2008) Effect of electrical stimulation of the cervical spinal cord on blood flow following subarachnoid hemorrhage. J Neurosurg 109(6):1148–1154PubMedCrossRef Lee JY, Huang DL, Keep R, Sagher O (2008) Effect of electrical stimulation of the cervical spinal cord on blood flow following subarachnoid hemorrhage. J Neurosurg 109(6):1148–1154PubMedCrossRef
11.
Zurück zum Zitat Linderoth B, Fedorcsak I, Meyerson BA (1991) Peripheral vasodilatation after spinal cord stimulation: animal studies of putative effector mechanisms. Neurosurgery 28(2):187–195PubMedCrossRef Linderoth B, Fedorcsak I, Meyerson BA (1991) Peripheral vasodilatation after spinal cord stimulation: animal studies of putative effector mechanisms. Neurosurgery 28(2):187–195PubMedCrossRef
12.
Zurück zum Zitat Mannheimer C, Carlsson CA, Emanuelsson H, Vedin A, Waagstein F, Wilhelmsson C (1985) The effects of transcutaneous electrical nerve stimulation in patients with severe angina pectoris. Circulation 71(2):308–316PubMed Mannheimer C, Carlsson CA, Emanuelsson H, Vedin A, Waagstein F, Wilhelmsson C (1985) The effects of transcutaneous electrical nerve stimulation in patients with severe angina pectoris. Circulation 71(2):308–316PubMed
13.
Zurück zum Zitat Oakley JC, Prager JP (2002) Spinal cord stimulation: mechanisms of action. Spine 27(22):2574–2583PubMedCrossRef Oakley JC, Prager JP (2002) Spinal cord stimulation: mechanisms of action. Spine 27(22):2574–2583PubMedCrossRef
14.
Zurück zum Zitat Padayachee TS, Kirkham FJ, Lewis RR, Gillard J, Hutchinson MCE, Gosling RG (1986) Transcranial measurement of blood velocities in the basal cerebral arteries using pulsed Doppler ultrasound: a method of assessing the Circle of Willis. Ultrasound Med Biol 12(1):5–14PubMedCrossRef Padayachee TS, Kirkham FJ, Lewis RR, Gillard J, Hutchinson MCE, Gosling RG (1986) Transcranial measurement of blood velocities in the basal cerebral arteries using pulsed Doppler ultrasound: a method of assessing the Circle of Willis. Ultrasound Med Biol 12(1):5–14PubMedCrossRef
15.
Zurück zum Zitat Patel S (2004) Evidence for a central pathway in the cerebrovascular effects of spinal cord stimulation. Neurosurgery 55(1):201–206PubMedCrossRef Patel S (2004) Evidence for a central pathway in the cerebrovascular effects of spinal cord stimulation. Neurosurgery 55(1):201–206PubMedCrossRef
16.
Zurück zum Zitat Pinheiro JC, Bates JM (2000) Mixed-effects models in S and S-PLUS. Illustrated ed. Springer, New York Pinheiro JC, Bates JM (2000) Mixed-effects models in S and S-PLUS. Illustrated ed. Springer, New York
17.
Zurück zum Zitat Sanderson JE, Tomlinson B, Lau MS, So KW, Cheung AH, Critchley JA, Woo KS (1995) The effect of transcutaneous electrical nerve stimulation (TENS) on autonomic cardiovascular reflexes. Clin Auton Res 5(2):81–84PubMedCrossRef Sanderson JE, Tomlinson B, Lau MS, So KW, Cheung AH, Critchley JA, Woo KS (1995) The effect of transcutaneous electrical nerve stimulation (TENS) on autonomic cardiovascular reflexes. Clin Auton Res 5(2):81–84PubMedCrossRef
18.
19.
Zurück zum Zitat Van Lieshout JJ, Secher NH (2008) Point:counterpoint: sympathetic activity does/does not influence cerebral blood flow. Point: sympathetic activity does influence cerebral blood flow. J Appl Physiol 105(4):1364–1366PubMedCrossRef Van Lieshout JJ, Secher NH (2008) Point:counterpoint: sympathetic activity does/does not influence cerebral blood flow. Point: sympathetic activity does influence cerebral blood flow. J Appl Physiol 105(4):1364–1366PubMedCrossRef
20.
Zurück zum Zitat Van Lieshout JJ, Secher NH (2008) Last word on point:counterpoint: sympathetic activity does/does not influence cerebral blood flow. J Appl Physiol 105(4):1374PubMedCrossRef Van Lieshout JJ, Secher NH (2008) Last word on point:counterpoint: sympathetic activity does/does not influence cerebral blood flow. J Appl Physiol 105(4):1374PubMedCrossRef
21.
Zurück zum Zitat Vriens EM (1989) Transcranial pulsed Doppler measurements of blood velocity in the middle cerebral artery: reference values at rest and during hyperventilation in healthy volunteers in relation to age and sex. Ultrasound Med Biol 15(1):1–8PubMedCrossRef Vriens EM (1989) Transcranial pulsed Doppler measurements of blood velocity in the middle cerebral artery: reference values at rest and during hyperventilation in healthy volunteers in relation to age and sex. Ultrasound Med Biol 15(1):1–8PubMedCrossRef
Metadaten
Titel
The influence of transcutaneous electrical neurostimulation (TENS) on human cerebral blood flow velocities
verfasst von
Mark ter Laan
J. Marc C. van Dijk
Jan-Willem J. Elting
Vaclav Fidler
Michiel J. Staal
Publikationsdatum
01.08.2010
Verlag
Springer Vienna
Erschienen in
Acta Neurochirurgica / Ausgabe 8/2010
Print ISSN: 0001-6268
Elektronische ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-010-0678-6

Weitere Artikel der Ausgabe 8/2010

Acta Neurochirurgica 8/2010 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Frühe Alzheimertherapie lohnt sich

25.04.2024 AAN-Jahrestagung 2024 Nachrichten

Ist die Tau-Last noch gering, scheint der Vorteil von Lecanemab besonders groß zu sein. Und beginnen Erkrankte verzögert mit der Behandlung, erreichen sie nicht mehr die kognitive Leistung wie bei einem früheren Start. Darauf deuten neue Analysen der Phase-3-Studie Clarity AD.

Viel Bewegung in der Parkinsonforschung

25.04.2024 Parkinson-Krankheit Nachrichten

Neue arznei- und zellbasierte Ansätze, Frühdiagnose mit Bewegungssensoren, Rückenmarkstimulation gegen Gehblockaden – in der Parkinsonforschung tut sich einiges. Auf dem Deutschen Parkinsonkongress ging es auch viel um technische Innovationen.

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.