Skip to main content
Erschienen in: HSS Journal ® 1/2017

25.08.2016 | Global Tribology Summit

The Role of Metal-on-Metal Bearings in Total Hip Arthroplasty and Hip Resurfacing

Review Article

verfasst von: David Sands, MSc, MD (c), Emil H. Schemitsch, MD, FRCSC

Erschienen in: HSS Journal ® | Ausgabe 1/2017

Einloggen, um Zugang zu erhalten

Abstract

Background

The current role of metal-on-metal (MoM) bearings in hip arthroplasty remains controversial. The low wear offered by MoM bearings compared to metal-on-polyethylene and the possibility of a lower risk of dislocation with larger head sizes, encouraged a trend towards the re-introduction of the MoM bearing couple. However, recent evidence has shown that not all designs of the MoM bearing have been successful.

Questions/Purposes

The purpose of this paper is to provide an update on the use of MoM bearings and address the following issues: (1) the reintroduction of metal-on-metal bearings in total hip arthroplasty, (2) the failure of metal-on-metal bearings in stemmed total hip arthroplasty, (3) the role of metal-on-metal hip resurfacing in modern orthopaedics and (4) metal-on-metal hip resurfacing versus total hip arthroplasty.

Methods

A literature search strategy was conducted using various search terms in MEDLINE and Embase. The highest quality articles that met the inclusion criteria and best answered the topics of focus of this review were selected. Key search terms included ‘metal-on-metal’, ‘total hip arthroplasty’ and ‘hip resurfacing’.

Results

The initial search retrieved 1240 articles. Twenty-two articles were selected and used in the review.

Conclusion

Metal-on-metal hip resurfacing is still a suitable treatment option in specific patient populations with the appropriate implant design and surgical skill, while stemmed metal-on-metal total hip arthroplasty should be avoided in all patient populations. Continued follow-up of patients undergoing metal-on-metal hip resurfacing is critical in order to further understand the long-term outcomes of these patients and why certain complications tend to occur with this procedure.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Australian Orthopaedic Association National Joint Replacement Registry. Annual report. Adelaide: AOA; 2014. Australian Orthopaedic Association National Joint Replacement Registry. Annual report. Adelaide: AOA; 2014.
2.
Zurück zum Zitat Bayley N, Khan H, Grosso P, et al. What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA? Clin Orthop Relat Res. 2015; 473(2): 477-484.CrossRefPubMed Bayley N, Khan H, Grosso P, et al. What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA? Clin Orthop Relat Res. 2015; 473(2): 477-484.CrossRefPubMed
3.
Zurück zum Zitat Bernstein M, Desy NM, Petit A, Zukor DJ, Huk OL, Antoniou J. Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty. Int Orthop. 2012; 36(9): 1807-1812.CrossRefPubMedPubMedCentral Bernstein M, Desy NM, Petit A, Zukor DJ, Huk OL, Antoniou J. Long-term follow-up and metal ion trend of patients with metal-on-metal total hip arthroplasty. Int Orthop. 2012; 36(9): 1807-1812.CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Bolland BJ, Culliford DJ, Langton DJ, Millington JP, Arden NK, Latham JM. High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: Clinical, radiological and retrieval analysis. J Bone Joint Surg (Br). 2011; 93(5): 608-615.CrossRef Bolland BJ, Culliford DJ, Langton DJ, Millington JP, Arden NK, Latham JM. High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: Clinical, radiological and retrieval analysis. J Bone Joint Surg (Br). 2011; 93(5): 608-615.CrossRef
5.
Zurück zum Zitat Bosker BH, Ettema HB, Boomsma MF, Kollen BJ, Maas M, Verheyen CC. High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement: A prospective cohort study. J Bone Joint Surg (Br). 2012; 94(6): 755-761.CrossRef Bosker BH, Ettema HB, Boomsma MF, Kollen BJ, Maas M, Verheyen CC. High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement: A prospective cohort study. J Bone Joint Surg (Br). 2012; 94(6): 755-761.CrossRef
6.
Zurück zum Zitat Canadian Hip Resurfacing Study Group. A survey on the prevalence of pseudotumors with metal-on-metal hip resurfacing in Canadian Academic Centers. J Bone Joint Surg Am. 2011; 93(Suppl 2): 118-121.CrossRef Canadian Hip Resurfacing Study Group. A survey on the prevalence of pseudotumors with metal-on-metal hip resurfacing in Canadian Academic Centers. J Bone Joint Surg Am. 2011; 93(Suppl 2): 118-121.CrossRef
8.
Zurück zum Zitat Dowson D, Jin ZM. Metal-on-metal hip joint tribology. Proc Inst Mech Eng H. 2006; 220(2): 107-118.CrossRefPubMed Dowson D, Jin ZM. Metal-on-metal hip joint tribology. Proc Inst Mech Eng H. 2006; 220(2): 107-118.CrossRefPubMed
9.
Zurück zum Zitat Engh CA, MacDonald SJ, Sritulanondha S, Korczak A, Naudie D, Engh C. Metal ion levels after metal-on-metal total hip arthroplasty: a five-year, prospective randomized trial. J Bone Joint Surg Am. 2014; 96(6): 448-455.CrossRefPubMed Engh CA, MacDonald SJ, Sritulanondha S, Korczak A, Naudie D, Engh C. Metal ion levels after metal-on-metal total hip arthroplasty: a five-year, prospective randomized trial. J Bone Joint Surg Am. 2014; 96(6): 448-455.CrossRefPubMed
10.
Zurück zum Zitat Fricka KB, Ho H, Peace WJ, Engh CA Jr. Metal-on-metal local tissue reaction is associated with corrosion of the head taper junction. J Arthroplasty. 2012; 27(8 Suppl): 26-31.e1.CrossRefPubMed Fricka KB, Ho H, Peace WJ, Engh CA Jr. Metal-on-metal local tissue reaction is associated with corrosion of the head taper junction. J Arthroplasty. 2012; 27(8 Suppl): 26-31.e1.CrossRefPubMed
11.
Zurück zum Zitat Haddad FS, Thakrar RR, Hart AJ, et al. Metal-on-metal bearings: the evidence so far. J Bone Joint Surg (Br). 2011; 93(5): 572-579.CrossRef Haddad FS, Thakrar RR, Hart AJ, et al. Metal-on-metal bearings: the evidence so far. J Bone Joint Surg (Br). 2011; 93(5): 572-579.CrossRef
12.
Zurück zum Zitat Hart AJ, Satchithananda K, Liddle AD, et al. Pseudotumors in association with well-functioning metal-on-metal hip prostheses: a case-control study using three-dimensional computed tomography and magnetic resonance imaging. J Bone Joint Surg Am. 2012; 94(4): 317-325.CrossRefPubMed Hart AJ, Satchithananda K, Liddle AD, et al. Pseudotumors in association with well-functioning metal-on-metal hip prostheses: a case-control study using three-dimensional computed tomography and magnetic resonance imaging. J Bone Joint Surg Am. 2012; 94(4): 317-325.CrossRefPubMed
13.
Zurück zum Zitat Heintzbergen S, Kulin NA, Ijzerman MJ, et al. Cost-utility of metal-on-metal hip resurfacing compared to conventional total hip replacement in young active patients with osteoarthritis. Value Health. 2013; 16(6): 942-952.CrossRefPubMed Heintzbergen S, Kulin NA, Ijzerman MJ, et al. Cost-utility of metal-on-metal hip resurfacing compared to conventional total hip replacement in young active patients with osteoarthritis. Value Health. 2013; 16(6): 942-952.CrossRefPubMed
14.
Zurück zum Zitat Innmann MM, Gotterbarm T, Kretzer JP, et al. Minimum ten-year results of a 28-mm metal-on-metal bearing in cementless total hip arthroplasty in patients fifty years of age and younger. Int Orthop. 2014; 38(5): 929-934.CrossRefPubMed Innmann MM, Gotterbarm T, Kretzer JP, et al. Minimum ten-year results of a 28-mm metal-on-metal bearing in cementless total hip arthroplasty in patients fifty years of age and younger. Int Orthop. 2014; 38(5): 929-934.CrossRefPubMed
15.
Zurück zum Zitat Kinbrum A, Unsworth A. The wear of high-carbon metal-on-metal bearings after different heat treatments. Proc Inst Mech Eng H. 2008; 222(6): 887-895.CrossRefPubMed Kinbrum A, Unsworth A. The wear of high-carbon metal-on-metal bearings after different heat treatments. Proc Inst Mech Eng H. 2008; 222(6): 887-895.CrossRefPubMed
16.
Zurück zum Zitat Kwon YM, Ostlere SJ, McLardy-Smith P, Athanasou NA, Gill HS, Murray DW. “Asymptomatic” pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study. J Arthroplasty. 2011; 26(4): 511-518.CrossRefPubMed Kwon YM, Ostlere SJ, McLardy-Smith P, Athanasou NA, Gill HS, Murray DW. “Asymptomatic” pseudotumors after metal-on-metal hip resurfacing arthroplasty: prevalence and metal ion study. J Arthroplasty. 2011; 26(4): 511-518.CrossRefPubMed
17.
Zurück zum Zitat Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV. Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg (Br). 2010; 92(1): 38-46.CrossRef Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV. Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg (Br). 2010; 92(1): 38-46.CrossRef
18.
Zurück zum Zitat Lavigne M, Belzile EL, Roy A, Morin F, Amzica T, Vendittoli PA. Comparison of whole-blood metal ion levels in four types of metal-on-metal large-diameter femoral head total hip arthroplasty: the potential influence of the adapter sleeve. J Bone Joint Surg Am. 2011; 93(Suppl 2): 128-136.CrossRefPubMed Lavigne M, Belzile EL, Roy A, Morin F, Amzica T, Vendittoli PA. Comparison of whole-blood metal ion levels in four types of metal-on-metal large-diameter femoral head total hip arthroplasty: the potential influence of the adapter sleeve. J Bone Joint Surg Am. 2011; 93(Suppl 2): 128-136.CrossRefPubMed
19.
Zurück zum Zitat Marshall DA, Pykerman K, Werle J, et al. Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes. Clin Orthop Relat Res. 2014; 472(7): 2217-2230.CrossRefPubMedPubMedCentral Marshall DA, Pykerman K, Werle J, et al. Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes. Clin Orthop Relat Res. 2014; 472(7): 2217-2230.CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Matharu GS, Pandit HG, Murray DW, Treacy RB. The future role of metal-on-metal hip resurfacing. Int Orthop. 2015. Matharu GS, Pandit HG, Murray DW, Treacy RB. The future role of metal-on-metal hip resurfacing. Int Orthop. 2015.
21.
Zurück zum Zitat Matthies AK, Skinner JA, Osmani H, Henckel J, Hart AJ. Pseudotumors are common in well-positioned low-wearing metal-on-metal hips. Clin Orthop Relat Res. 2012; 470(7): 1895-1906.CrossRefPubMed Matthies AK, Skinner JA, Osmani H, Henckel J, Hart AJ. Pseudotumors are common in well-positioned low-wearing metal-on-metal hips. Clin Orthop Relat Res. 2012; 470(7): 1895-1906.CrossRefPubMed
22.
Zurück zum Zitat Matthies A, Underwood R, Cann P, et al. Retrieval analysis of 240 metal-on-metal hip components, comparing modular total hip replacement with hip resurfacing. J Bone Joint Surg (Br). 2011; 93(3): 307-314.CrossRef Matthies A, Underwood R, Cann P, et al. Retrieval analysis of 240 metal-on-metal hip components, comparing modular total hip replacement with hip resurfacing. J Bone Joint Surg (Br). 2011; 93(3): 307-314.CrossRef
23.
Zurück zum Zitat McNamara I, Manktelow A. (Iv) metal on metal hip replacement. Orthopaed Trauma. 2013; 27(5): 287-295.CrossRef McNamara I, Manktelow A. (Iv) metal on metal hip replacement. Orthopaed Trauma. 2013; 27(5): 287-295.CrossRef
24.
Zurück zum Zitat Meyer H, Mueller T, Goldau G, Chamaon K, Ruetschi M, Lohmann CH. Corrosion at the cone/taper interface leads to failure of large-diameter metal-on-metal total hip arthroplasties. Clin Orthop Relat Res. 2012; 470(11): 3101-3108.CrossRefPubMedPubMedCentral Meyer H, Mueller T, Goldau G, Chamaon K, Ruetschi M, Lohmann CH. Corrosion at the cone/taper interface leads to failure of large-diameter metal-on-metal total hip arthroplasties. Clin Orthop Relat Res. 2012; 470(11): 3101-3108.CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Murgatroyd SE. Pseudotumor presenting as a pelvic mass: a complication of eccentric wear of a metal on polyethylene hip arthroplasty. J Arthroplasty. 2012; 27(5): 820.e1-820.e4.CrossRef Murgatroyd SE. Pseudotumor presenting as a pelvic mass: a complication of eccentric wear of a metal on polyethylene hip arthroplasty. J Arthroplasty. 2012; 27(5): 820.e1-820.e4.CrossRef
26.
Zurück zum Zitat Sehatzadeh S, Kaulback K, Levin L. Metal-on-metal hip resurfacing arthroplasty: an analysis of safety and revision rates. Ont Health Technol Assess Ser. 2012; 12(19): 1-63. Sehatzadeh S, Kaulback K, Levin L. Metal-on-metal hip resurfacing arthroplasty: an analysis of safety and revision rates. Ont Health Technol Assess Ser. 2012; 12(19): 1-63.
27.
Zurück zum Zitat Smith AJ, Dieppe P, Vernon K, Porter M, Blom AW, National Joint Registry of England and Wales. Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales. Lancet. 2012; 379(9822): 1199-1204.CrossRefPubMed Smith AJ, Dieppe P, Vernon K, Porter M, Blom AW, National Joint Registry of England and Wales. Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales. Lancet. 2012; 379(9822): 1199-1204.CrossRefPubMed
28.
Zurück zum Zitat Underwood RJ, Zografos A, Sayles RS, Hart A, Cann P. Edge loading in metal-on-metal hips: low clearance is a new risk factor. Proc Inst Mech Eng H. 2012; 226(3): 217-226.CrossRefPubMedPubMedCentral Underwood RJ, Zografos A, Sayles RS, Hart A, Cann P. Edge loading in metal-on-metal hips: low clearance is a new risk factor. Proc Inst Mech Eng H. 2012; 226(3): 217-226.CrossRefPubMedPubMedCentral
29.
Zurück zum Zitat Vendittoli PA, Roy A, Mottard S, Girard J, Lusignan D, Lavigne M. Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study. J Bone Joint Surg (Br). 2010; 92(1): 12-19.CrossRef Vendittoli PA, Roy A, Mottard S, Girard J, Lusignan D, Lavigne M. Metal ion release from bearing wear and corrosion with 28 mm and large-diameter metal-on-metal bearing articulations: a follow-up study. J Bone Joint Surg (Br). 2010; 92(1): 12-19.CrossRef
30.
Zurück zum Zitat Walsh AJ, Nikolaou VS, Antoniou J. Inflammatory pseudotumor complicating metal-on-highly cross-linked polyethylene total hip arthroplasty. J Arthroplasty. 2012; 27(2): 324.e5-324.e8.CrossRef Walsh AJ, Nikolaou VS, Antoniou J. Inflammatory pseudotumor complicating metal-on-highly cross-linked polyethylene total hip arthroplasty. J Arthroplasty. 2012; 27(2): 324.e5-324.e8.CrossRef
31.
Zurück zum Zitat Zijlstra WP, Bos N, van Raaij JJ. Large head metal-on-metal cementless total hip arthroplasty versus 28 mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial. BMC Musculoskelet Disord. 2008;9:136-2474-9-136. Zijlstra WP, Bos N, van Raaij JJ. Large head metal-on-metal cementless total hip arthroplasty versus 28 mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial. BMC Musculoskelet Disord. 2008;9:136-2474-9-136.
Metadaten
Titel
The Role of Metal-on-Metal Bearings in Total Hip Arthroplasty and Hip Resurfacing
Review Article
verfasst von
David Sands, MSc, MD (c)
Emil H. Schemitsch, MD, FRCSC
Publikationsdatum
25.08.2016
Verlag
Springer US
Erschienen in
HSS Journal ® / Ausgabe 1/2017
Print ISSN: 1556-3316
Elektronische ISSN: 1556-3324
DOI
https://doi.org/10.1007/s11420-016-9521-9

Weitere Artikel der Ausgabe 1/2017

HSS Journal ® 1/2017 Zur Ausgabe

Global Tribology Summit

Global Tribology Summit Editorial

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.