The scalographic pattern of Morlet continuous wavelet transform can differentiate bileaflet valve function

verfasst von: Hiroshi Sugiki, Kenji Sugiki

Erschienen in: Journal of Artificial Organs | Ausgabe 3/2018

Einloggen, um Zugang zu erhalten

Abstract

The authors have discussed the significance of the Morlet continuous wavelet transform of bileaflet mechanical heart valve (BLMHV) sound for detecting its malfunction: consecutive single patterns on the scalogram alway suggested its malfunction, whereas the tandem pattern with two steepled figures was demonstrated in both normal and malfunctioning valves. Therefore, authors have tried to distinguish this pattern between them by manually calculated multiple scalographic parameters. Although only the sum of wavelet coefficients (SWC) is supposed to be closer to valve sound property than other parameters, its calculation was not available in the original wavelet application. Therefore, the application was customized in the current study to semi-automatically calculate the SWC ratio between two figures for classifying the scalographic pattern of malfunctioning valves, and its efficacy to distinguish valve function was compared to other parameters. Among 155 BLMHVs, 6 valves with consecutive single patterns (type-I) and other 6 with two similar needle-like narrow figures (type-II) were confirmed to be a malfunction by fluoroscopic examination, whereas 14 malfunctioning valves with the tandem pattern which showed a great difference between two figure sizes (type-III) were distinguished from 129 normal valves by the cutoff point of the SWC ratio < 0.482 with the highest AUC (0.960) compared to other parameters by the ROC analysis.
Literatur
1.
Zurück zum Zitat Sugiki H, Murashita T, Shiiya N, Kubota T, Yasuda K. Selection of the analyzing wavelet adequate to analyze artificial mechanical valve sound (in Japanese). Jpn J Artif Organs. 2004;33:Supplement-158. Sugiki H, Murashita T, Shiiya N, Kubota T, Yasuda K. Selection of the analyzing wavelet adequate to analyze artificial mechanical valve sound (in Japanese). Jpn J Artif Organs. 2004;33:Supplement-158.
2.
Zurück zum Zitat Sugiki H, Murashita T, Shiiya N, Kunihara T, Matsuzaki K, Kubota T, Sugiki K. The trials of diagnosis of bileaflet mechanical valve malfunction by the wavelet analysis (in Japanese). Jpn J Cardiovasc Surg. 2005;53:Supplement-515. Sugiki H, Murashita T, Shiiya N, Kunihara T, Matsuzaki K, Kubota T, Sugiki K. The trials of diagnosis of bileaflet mechanical valve malfunction by the wavelet analysis (in Japanese). Jpn J Cardiovasc Surg. 2005;53:Supplement-515.
3.
Zurück zum Zitat Sugiki H, Shiiya N, Murashita T, Kubota T, Kunihara T, Matsuzaki K, Sugiki T, Sugiki K. The study on the wavelet analysis of bileaflet mechanical valve closing sound (in Japanese). Jpn J Artif Organs. 2005;34:S-172. Sugiki H, Shiiya N, Murashita T, Kubota T, Kunihara T, Matsuzaki K, Sugiki T, Sugiki K. The study on the wavelet analysis of bileaflet mechanical valve closing sound (in Japanese). Jpn J Artif Organs. 2005;34:S-172.
4.
Zurück zum Zitat Sugiki H, Shiiya N, Murashita T, Yasuda K. Bileaflet mechanical valve sound analysis with continuous wavelet transform. J Artif Orgrans. 2006;9:42 – 9.CrossRef Sugiki H, Shiiya N, Murashita T, Yasuda K. Bileaflet mechanical valve sound analysis with continuous wavelet transform. J Artif Orgrans. 2006;9:42 – 9.CrossRef
5.
Zurück zum Zitat Sugiki H, Shiiya N, Murashita T, Kunihara T, Matsuzaki K, Kubota T, Matsui Y, Sugiki K. Wavelet analyis of bileaflet mechanical valve sounds. J Artif Organs. 2007;10:16–21.CrossRefPubMed Sugiki H, Shiiya N, Murashita T, Kunihara T, Matsuzaki K, Kubota T, Matsui Y, Sugiki K. Wavelet analyis of bileaflet mechanical valve sounds. J Artif Organs. 2007;10:16–21.CrossRefPubMed
6.
Zurück zum Zitat Sugiki H, Murashita T, Shiiya N, Matsui Y, Sugiki K. Wavelet analysis of valve closing sound can detects malfunction of bileaflet mechanical valve. J Artif Organs. 2008;11:29–37.CrossRefPubMed Sugiki H, Murashita T, Shiiya N, Matsui Y, Sugiki K. Wavelet analysis of valve closing sound can detects malfunction of bileaflet mechanical valve. J Artif Organs. 2008;11:29–37.CrossRefPubMed
7.
Zurück zum Zitat Sugiki T, Sugiki H, Shiiya N, Matsui Y, Sugiki K. New automated wavelet analytical system with a cellular phone for recording intercellular phone remote transmitted bileaflet valve sound. J Artif Organs. 2009; 12:232–41.CrossRefPubMed Sugiki T, Sugiki H, Shiiya N, Matsui Y, Sugiki K. New automated wavelet analytical system with a cellular phone for recording intercellular phone remote transmitted bileaflet valve sound. J Artif Organs. 2009; 12:232–41.CrossRefPubMed
8.
Zurück zum Zitat Sugiki H, Kubota S, Matsui Y, Sugiki K. Comparison of two spike areas in bileaflet mechanical valve closing sound. J Artif Organs. 2012;15:357–63.CrossRefPubMed Sugiki H, Kubota S, Matsui Y, Sugiki K. Comparison of two spike areas in bileaflet mechanical valve closing sound. J Artif Organs. 2012;15:357–63.CrossRefPubMed
11.
Zurück zum Zitat Akoheng AK. Understanding diagnostic test 3; receiver operating characteristic curves. Acta Paediatricca. 2007;96:644–7.CrossRef Akoheng AK. Understanding diagnostic test 3; receiver operating characteristic curves. Acta Paediatricca. 2007;96:644–7.CrossRef
12.
Zurück zum Zitat Fluss R, Faraggi D, Reiser B. Estimation of the Youden Index and its associated cutoff point. Biom J. 2005;47:458 – 72.CrossRefPubMed Fluss R, Faraggi D, Reiser B. Estimation of the Youden Index and its associated cutoff point. Biom J. 2005;47:458 – 72.CrossRefPubMed
13.
Zurück zum Zitat Gomi A, Takeuchi Y, Okamura Y, Yokomuro H, Mori H, Hattori J, Masuda H. The improving method for the wave and frequency analysis of the various prosthetic heart valves sound (in Japanese). Jpn J Artif Organs. 1989;18(2):698–701. Gomi A, Takeuchi Y, Okamura Y, Yokomuro H, Mori H, Hattori J, Masuda H. The improving method for the wave and frequency analysis of the various prosthetic heart valves sound (in Japanese). Jpn J Artif Organs. 1989;18(2):698–701.
14.
Zurück zum Zitat Tsubota M, Misaki T, Matsunaga Y, Iwa T, Funada T. Basic study of wave shape and spectral analysis of mechanical valve closing sound (in Japanese). Jpn J Artif Organs. 1989;18(2):702–5. Tsubota M, Misaki T, Matsunaga Y, Iwa T, Funada T. Basic study of wave shape and spectral analysis of mechanical valve closing sound (in Japanese). Jpn J Artif Organs. 1989;18(2):702–5.
15.
Zurück zum Zitat Sugiki K, Ohno T, Sasaki A, Doi H. New analyzing system of mechanical valve sounds and the possibilities of the clinical application. KOKYU TO JUNKAN (in Japanese). 1994;42(9):871–6. Sugiki K, Ohno T, Sasaki A, Doi H. New analyzing system of mechanical valve sounds and the possibilities of the clinical application. KOKYU TO JUNKAN (in Japanese). 1994;42(9):871–6.
16.
Zurück zum Zitat Fujita Y, Hayashi J, Moro H, Saito A, Ueno M, Eguchi S, Hori J, Saito Y. Frequency spectrum analysis of closing sound of SJM cardiac valve prosthesis in vitro and in vivo. Jpn J Artif organs. 1991;20(3):915–8. Fujita Y, Hayashi J, Moro H, Saito A, Ueno M, Eguchi S, Hori J, Saito Y. Frequency spectrum analysis of closing sound of SJM cardiac valve prosthesis in vitro and in vivo. Jpn J Artif organs. 1991;20(3):915–8.
17.
Zurück zum Zitat Donnerstein RL, Allen HD. Asynchronous leaflet closure in normally functioning bileaflet mechanical valve. Am Heart J. 1990;119:694–7.CrossRefPubMed Donnerstein RL, Allen HD. Asynchronous leaflet closure in normally functioning bileaflet mechanical valve. Am Heart J. 1990;119:694–7.CrossRefPubMed
Metadaten
Titel
The scalographic pattern of Morlet continuous wavelet transform can differentiate bileaflet valve function
verfasst von
Hiroshi Sugiki
Kenji Sugiki
Publikationsdatum
06.03.2018
Verlag
Springer Japan
Erschienen in
Journal of Artificial Organs / Ausgabe 3/2018
Print ISSN: 1434-7229
Elektronische ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-018-1031-8

Weitere Artikel der Ausgabe 3/2018

Journal of Artificial Organs 3/2018 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.