Skip to main content
Erschienen in: International Orthopaedics 3/2019

27.03.2018 | Review Article

Total knee arthroplasties from the origin to navigation: history, rationale, indications

verfasst von: Dominique Saragaglia, Brice Rubens-Duval, Julia Gaillot, Gabriel Lateur, Régis Pailhé

Erschienen in: International Orthopaedics | Ausgabe 3/2019

Einloggen, um Zugang zu erhalten

Abstract

Since the early 1970s, total knee arthroplasties have undergone many changes in both their design and their surgical instrumentation. It soon became apparent that to improve prosthesis durability, it was essential to have instruments which allowed them to be fitted reliably and consistently. Despite increasingly sophisticated surgical techniques, preoperative objectives were only met in 75% of cases, which led to the development, in the early 1990s, in Grenoble (France), of computer-assisted orthopaedic surgery for knee prosthesis implantation. In the early 2000s, many navigation systems emerged, some including pre-operative imagery (“CT-based”), others using intra-operative imagery (“fluoroscopy-based”), and yet others with no imagery at all (“imageless”), which soon became the navigation “gold standard”. They use an optoelectronic tracker, markers which are fixed solidly to the bones and instruments, and a navigation workstation (computer), with a control system (e.g. pedal). Despite numerous studies demonstrating the benefit of computer navigation in meeting preoperative objectives, such systems have not yet achieved the success they warrant, for various reasons we will be covering in this article. If the latest navigation systems prove to be as effective as the older systems, they should give this type of technology a well-deserved boost.
Literatur
1.
Zurück zum Zitat Aubriot JH (1989) historique et évolution des prothèses totales du genou. Cahier d’enseignement de la SOFCOT n°35. Expans Sci Fr Paris 189:4 Aubriot JH (1989) historique et évolution des prothèses totales du genou. Cahier d’enseignement de la SOFCOT n°35. Expans Sci Fr Paris 189:4
2.
Zurück zum Zitat Aubriot JH, Deburge A, Kenesi CL, Schramm P (1973) La prothèse Guépar. Acta Orthop Belg 39:257–279PubMed Aubriot JH, Deburge A, Kenesi CL, Schramm P (1973) La prothèse Guépar. Acta Orthop Belg 39:257–279PubMed
3.
Zurück zum Zitat Trillat A, Dejour H, Bousquet G, Grammont P (1973) La prothèse rotatoire du genou. Rev Chir Orthop Reparatrice Appar Mot 59:513–522PubMed Trillat A, Dejour H, Bousquet G, Grammont P (1973) La prothèse rotatoire du genou. Rev Chir Orthop Reparatrice Appar Mot 59:513–522PubMed
4.
Zurück zum Zitat Gunston FH (1971) Polycentric knee arthroplasty. J Bone Joint Surg Br 53:272–277PubMed Gunston FH (1971) Polycentric knee arthroplasty. J Bone Joint Surg Br 53:272–277PubMed
5.
Zurück zum Zitat Marmor L (1973) The modular knee. Clin Orthop Relat Res 94:242–248 Marmor L (1973) The modular knee. Clin Orthop Relat Res 94:242–248
6.
Zurück zum Zitat Goodfellow J, O’Connor J (1978) The mechanics of the knee and prosthesis design. J Bone Joint Surg Br 60:358–369PubMed Goodfellow J, O’Connor J (1978) The mechanics of the knee and prosthesis design. J Bone Joint Surg Br 60:358–369PubMed
7.
Zurück zum Zitat Cloutier JM (1983) Results of total knee arthroplasty with a non-constrained prosthesis. J Bone Joint Surg Am 65:906–919PubMed Cloutier JM (1983) Results of total knee arthroplasty with a non-constrained prosthesis. J Bone Joint Surg Am 65:906–919PubMed
8.
Zurück zum Zitat Insall J, Lachiewicz PF, Burnstein AH (1982) The posterior stabilized condylar prosthesis: a modification of the total condylar design. Two to four-year clinical experience. J Bone Joint Surg Am 64:1317–1323PubMed Insall J, Lachiewicz PF, Burnstein AH (1982) The posterior stabilized condylar prosthesis: a modification of the total condylar design. Two to four-year clinical experience. J Bone Joint Surg Am 64:1317–1323PubMed
9.
Zurück zum Zitat Buechel FF, Pappas MJ (1986) The New Jersey Low-Contact-Stress Knee Replacement System: biomechanical rationale and review of the first 123 cemented cases. Arch Orthop Trauma Surg 105:197–204PubMed Buechel FF, Pappas MJ (1986) The New Jersey Low-Contact-Stress Knee Replacement System: biomechanical rationale and review of the first 123 cemented cases. Arch Orthop Trauma Surg 105:197–204PubMed
10.
Zurück zum Zitat Argenson JN, Parratte S, Ashour A, Saintmard B, Aubaniac JM (2012) The outcome of rotating-platform total knee arthroplasty with cement at a minimum of ten years of follow-up. J Bone Joint Surg Am 94:638–644PubMed Argenson JN, Parratte S, Ashour A, Saintmard B, Aubaniac JM (2012) The outcome of rotating-platform total knee arthroplasty with cement at a minimum of ten years of follow-up. J Bone Joint Surg Am 94:638–644PubMed
13.
Zurück zum Zitat Saragaglia D, Sigwalt L, Gaillot J, Morin V, Rubens-Duval B, Pailhé R (2017) Results with eight and a half years average follow-up on two hundred and eight e-Motion FP® knee prostheses, fitted using computer navigation for knee osteoarthritis in patients with over ten degrees genu varum. Int Orthop. https://doi.org/10.1007/s00264-017-3618-8 Saragaglia D, Sigwalt L, Gaillot J, Morin V, Rubens-Duval B, Pailhé R (2017) Results with eight and a half years average follow-up on two hundred and eight e-Motion FP® knee prostheses, fitted using computer navigation for knee osteoarthritis in patients with over ten degrees genu varum. Int Orthop. https://​doi.​org/​10.​1007/​s00264-017-3618-8
14.
Zurück zum Zitat Argenson JN, Scuderi GR, Komistek RD, Scott WN, Kelly MA, Aubaniac JM (2005) In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty. J Biomech 38:277–284PubMed Argenson JN, Scuderi GR, Komistek RD, Scott WN, Kelly MA, Aubaniac JM (2005) In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty. J Biomech 38:277–284PubMed
17.
Zurück zum Zitat Laskin RS (1991) Total knee replacement. Springer-Verlag, London, p 268 Laskin RS (1991) Total knee replacement. Springer-Verlag, London, p 268
18.
Zurück zum Zitat Bargren JH, Blaha JD, Freeman MAR (1983) Alignment in total knee arthroplasty: correlated biomechanical and clinical observations. Clin Orthop 173:178–183 Bargren JH, Blaha JD, Freeman MAR (1983) Alignment in total knee arthroplasty: correlated biomechanical and clinical observations. Clin Orthop 173:178–183
19.
Zurück zum Zitat Ecker ML, Lotke PA, Windor RE, Cello JP (1987) Long term results after total condylar knee arthroplasty. Clin Orthop 216:151–158 Ecker ML, Lotke PA, Windor RE, Cello JP (1987) Long term results after total condylar knee arthroplasty. Clin Orthop 216:151–158
20.
Zurück zum Zitat Hood RW, Vanni M, Insall JN (1981) The correction of knee alignment in 225 consecutive total condylar knee replacements. Clin Orthop 160:94–105 Hood RW, Vanni M, Insall JN (1981) The correction of knee alignment in 225 consecutive total condylar knee replacements. Clin Orthop 160:94–105
21.
Zurück zum Zitat Hsu H, Garg A, Walker PS, Spector M, Ewald FC (1989) Effect of knee component alignment on tibial load distribution with clinical correlation. Clin Orthop 248:135–144 Hsu H, Garg A, Walker PS, Spector M, Ewald FC (1989) Effect of knee component alignment on tibial load distribution with clinical correlation. Clin Orthop 248:135–144
22.
Zurück zum Zitat Jeffrey RS, Morris RW, Benham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714 Jeffrey RS, Morris RW, Benham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709–714
23.
Zurück zum Zitat Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59:77–79PubMed
24.
Zurück zum Zitat Ranawat CS, Boachie-Adjei O (1988) Survivorship analysis and results of total condylar knee arthroplasty. Clin Orthop 226:6–13 Ranawat CS, Boachie-Adjei O (1988) Survivorship analysis and results of total condylar knee arthroplasty. Clin Orthop 226:6–13
25.
Zurück zum Zitat Ritter MA, Faris PM, Keating E, Meding JB (1994) Postoperative alignment of total knee replacement: its effects on survival. Clin Orthop 299:153–157 Ritter MA, Faris PM, Keating E, Meding JB (1994) Postoperative alignment of total knee replacement: its effects on survival. Clin Orthop 299:153–157
26.
Zurück zum Zitat Tew M, Waugh W (1985) Tibial-femoral alignment and the results of knee replacement. J Bone Joint Surg Br 67:551–556PubMed Tew M, Waugh W (1985) Tibial-femoral alignment and the results of knee replacement. J Bone Joint Surg Br 67:551–556PubMed
27.
Zurück zum Zitat Picard F, Leitner F, Saragaglia D, Cinquin P (1997) Mise en place d’une prothèse totale du genou assistée par ordinateur: A propos de 7 implantations sur cadavre. Rev Chir Orthop Reparatrice Appar Mot 83(Suppl. II):31 Picard F, Leitner F, Saragaglia D, Cinquin P (1997) Mise en place d’une prothèse totale du genou assistée par ordinateur: A propos de 7 implantations sur cadavre. Rev Chir Orthop Reparatrice Appar Mot 83(Suppl. II):31
28.
Zurück zum Zitat Leitner F, Picard F, Minfelde R, Schultz HJ, Cinquin P, Saragaglia D (1997) Computer-assisted knee surgical total replacement. In: lecture note in computer science: CURMed-MRCAS'97. Springer Verlag, Berlin-Heidelberg, pp 629–638 Leitner F, Picard F, Minfelde R, Schultz HJ, Cinquin P, Saragaglia D (1997) Computer-assisted knee surgical total replacement. In: lecture note in computer science: CURMed-MRCAS'97. Springer Verlag, Berlin-Heidelberg, pp 629–638
29.
Zurück zum Zitat Saragaglia D, Picard F, Chaussard C, Montbarbon E, Leitner F, Cinquin P (2001) Mise en place des prothèses totale du genou assistée par ordinateur: comparaison avec la technique conventionnelle. A propos d’une étude prospective randomisée de 50 cas. Rev Chir Orthop Reparatrice Appar Mot 87:18–28PubMed Saragaglia D, Picard F, Chaussard C, Montbarbon E, Leitner F, Cinquin P (2001) Mise en place des prothèses totale du genou assistée par ordinateur: comparaison avec la technique conventionnelle. A propos d’une étude prospective randomisée de 50 cas. Rev Chir Orthop Reparatrice Appar Mot 87:18–28PubMed
30.
Zurück zum Zitat Saragaglia D, Roberts J (2005) Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum. Orthopaedics 28(Suppl n° 10):S1269–S1274 Saragaglia D, Roberts J (2005) Navigated osteotomies around the knee in 170 patients with osteoarthritis secondary to genu varum. Orthopaedics 28(Suppl n° 10):S1269–S1274
31.
Zurück zum Zitat Saragaglia D, Mercier N, Colle PE (2010) Computer-assisted osteotomies for genu varum deformity: which osteotomy for which varus? Int Orthop 34:185–190PubMed Saragaglia D, Mercier N, Colle PE (2010) Computer-assisted osteotomies for genu varum deformity: which osteotomy for which varus? Int Orthop 34:185–190PubMed
35.
Zurück zum Zitat Nizard RS, Porcher R, Ravaud P, Vangaver E, Hannouche D, Bizot P et al (2004) Use of the Cusum technique for evaluation of a CT-based navigation system for total knee replacement. Clin Orthop Relat Res 425:180–188 Nizard RS, Porcher R, Ravaud P, Vangaver E, Hannouche D, Bizot P et al (2004) Use of the Cusum technique for evaluation of a CT-based navigation system for total knee replacement. Clin Orthop Relat Res 425:180–188
36.
Zurück zum Zitat Weise M, Schmidt K, Willburger RE (2004) Clinical experience with CT-based VectorVision system. In: Stiehl JB, Konermann WH, Haaker RG (eds) Navigation and robotics in total joint and spine surgery. Springer-Verlag, Berlin, pp 301–303 Weise M, Schmidt K, Willburger RE (2004) Clinical experience with CT-based VectorVision system. In: Stiehl JB, Konermann WH, Haaker RG (eds) Navigation and robotics in total joint and spine surgery. Springer-Verlag, Berlin, pp 301–303
37.
Zurück zum Zitat Sparmann M, Wolke B (2004) Knee endoprosthesis navigation with the Stryker system. In: Stiehl JB, Konermann WH, Haaker RG (eds) Navigation and robotics in total joint and spine surgery. Springer-Verlag, Berlin, pp 319–323 Sparmann M, Wolke B (2004) Knee endoprosthesis navigation with the Stryker system. In: Stiehl JB, Konermann WH, Haaker RG (eds) Navigation and robotics in total joint and spine surgery. Springer-Verlag, Berlin, pp 319–323
38.
Zurück zum Zitat Perlick L, Bäthis H, Lüring C, Tingart M, Grifka J (2004) CT-based and CT-free navigation with the BrainLAB VectorVision system in total knee arthroplasty. In: Stiehl JB, Konermann WH, Haaker RG (eds) Navigation and robotics in total joint and spine surgery. Springer-Verlag, Berlin, pp 304–310 Perlick L, Bäthis H, Lüring C, Tingart M, Grifka J (2004) CT-based and CT-free navigation with the BrainLAB VectorVision system in total knee arthroplasty. In: Stiehl JB, Konermann WH, Haaker RG (eds) Navigation and robotics in total joint and spine surgery. Springer-Verlag, Berlin, pp 304–310
39.
Zurück zum Zitat Stindel E, Briard JL, Merloz P, Plaweski S, Dubrana F, Lefevre C et al (2002) Bone morphing: 3D morphological data for total knee arthroplasty. Comp Aid Surg 7:156–168 Stindel E, Briard JL, Merloz P, Plaweski S, Dubrana F, Lefevre C et al (2002) Bone morphing: 3D morphological data for total knee arthroplasty. Comp Aid Surg 7:156–168
40.
Zurück zum Zitat Hagena FW, Kettrukat M, Christ RM, Hackbart M (2004) Fluoroscopy-based navigation in genesis II total knee arthroplasty with Medtronic « Viking » system. In: Stiehl JB, Konermann WH, Haaker RG (eds) Navigation and robotics in total joint and spine surgery. Springer-Verlag, Berlin, pp 330–335 Hagena FW, Kettrukat M, Christ RM, Hackbart M (2004) Fluoroscopy-based navigation in genesis II total knee arthroplasty with Medtronic « Viking » system. In: Stiehl JB, Konermann WH, Haaker RG (eds) Navigation and robotics in total joint and spine surgery. Springer-Verlag, Berlin, pp 330–335
41.
Zurück zum Zitat Victor J, Hoste D (2004) Image-based computer-assisted total knee arthroplasty leads to lower variability in coronal alignment. Clin Orthop Relat Res 428:131–139 Victor J, Hoste D (2004) Image-based computer-assisted total knee arthroplasty leads to lower variability in coronal alignment. Clin Orthop Relat Res 428:131–139
42.
Zurück zum Zitat Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplast 22(8):1097–1106 Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplast 22(8):1097–1106
43.
Zurück zum Zitat Brin YS, Nikolaou VS, Joseph L, Zukor DJ, Antoniou J (2011) Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies. Int Orthop 35(3):331–339PubMed Brin YS, Nikolaou VS, Joseph L, Zukor DJ, Antoniou J (2011) Imageless computer assisted versus conventional total knee replacement. A Bayesian meta-analysis of 23 comparative studies. Int Orthop 35(3):331–339PubMed
44.
Zurück zum Zitat Cheng T, Zhao S, Peng X, Zhang X (2012) Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials. Knee Surg Sports Traumatol Arthrosc 20(7):1307–1322PubMed Cheng T, Zhao S, Peng X, Zhang X (2012) Does computer-assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta-analysis of randomized controlled trials. Knee Surg Sports Traumatol Arthrosc 20(7):1307–1322PubMed
45.
Zurück zum Zitat Hetaimish BM, Khan MM, Simunovic N, Al-Harbi HH, Bhandari M, Zalzal PK (2012) Meta-analysis of navigation vs conventional total knee arthroplasty. J Arthroplast 27(6):1177–1182 Hetaimish BM, Khan MM, Simunovic N, Al-Harbi HH, Bhandari M, Zalzal PK (2012) Meta-analysis of navigation vs conventional total knee arthroplasty. J Arthroplast 27(6):1177–1182
46.
Zurück zum Zitat Lee DH, Park JH, Song DI, Padhy D, Jeong WK, Han SB (2010) Accuracy of soft tissue balancing in TKA: comparison between navigation-assisted gap balancing and conventional measured resection. Knee Surg Sports Traumatol Arthrosc 18(3):381–387PubMed Lee DH, Park JH, Song DI, Padhy D, Jeong WK, Han SB (2010) Accuracy of soft tissue balancing in TKA: comparison between navigation-assisted gap balancing and conventional measured resection. Knee Surg Sports Traumatol Arthrosc 18(3):381–387PubMed
47.
Zurück zum Zitat Kim YH, Kim JS, Choi Y, Kwon OR (2009) Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty. J Bone Joint Surg Am 91(1):14–19PubMed Kim YH, Kim JS, Choi Y, Kwon OR (2009) Computer-assisted surgical navigation does not improve the alignment and orientation of the components in total knee arthroplasty. J Bone Joint Surg Am 91(1):14–19PubMed
48.
Zurück zum Zitat Burnett RSJ, Barrack RL (2013) Computer-assisted total knee arthroplasty is currently of no proven clinical benefit: a systematic review. Clin Orthop Relat Res 471(1):264–276PubMed Burnett RSJ, Barrack RL (2013) Computer-assisted total knee arthroplasty is currently of no proven clinical benefit: a systematic review. Clin Orthop Relat Res 471(1):264–276PubMed
49.
Zurück zum Zitat Rebal BA, Babatunde OM, Lee JH, Geller JA, Patrick DA, Macaulay W (2014) Imageless computer navigation in total knee arthroplasty provides superior short term functional outcomes: a meta-analysis. J Arthroplast 29(5):938–944 Rebal BA, Babatunde OM, Lee JH, Geller JA, Patrick DA, Macaulay W (2014) Imageless computer navigation in total knee arthroplasty provides superior short term functional outcomes: a meta-analysis. J Arthroplast 29(5):938–944
50.
Zurück zum Zitat De Steiger RN, Liu YL, Graves SE (2015) Computer navigation for total knee arthroplasty reduces revision rate for patients less than sixty-five years of age. J Bone Joint Surg Am 97(8):635–642PubMed De Steiger RN, Liu YL, Graves SE (2015) Computer navigation for total knee arthroplasty reduces revision rate for patients less than sixty-five years of age. J Bone Joint Surg Am 97(8):635–642PubMed
53.
Zurück zum Zitat Saragaglia D, Picard F (2004) Computer-assisted implantation of total knee endoprosthesis with no pre-operative imaging: the kinematic model. In: Stiehl JB, Konermann WH, Haaker RG (eds) Navigation and robotics in total joint and spine surgery. Springer-Verlag, Berlin, pp 226–233 Saragaglia D, Picard F (2004) Computer-assisted implantation of total knee endoprosthesis with no pre-operative imaging: the kinematic model. In: Stiehl JB, Konermann WH, Haaker RG (eds) Navigation and robotics in total joint and spine surgery. Springer-Verlag, Berlin, pp 226–233
60.
Zurück zum Zitat Kalairajah Y, Cossey AJ, Verrall GM, Ludbrook G, Spriggins AJ (2006) Are systemic emboli reduced in computer-assisted knee surgery? A prospective, randomised, clinical trial. J Bone Joint Surg Br 88(2):198–202PubMed Kalairajah Y, Cossey AJ, Verrall GM, Ludbrook G, Spriggins AJ (2006) Are systemic emboli reduced in computer-assisted knee surgery? A prospective, randomised, clinical trial. J Bone Joint Surg Br 88(2):198–202PubMed
61.
Zurück zum Zitat McConnell J, Dillon J, Kinninmonth A, Sarungi M, Picard F (2012) Blood loss following total knee replacement is reduced when using computer-assisted versus standard methods. Acta Orthop Belg 78(1):75–78PubMed McConnell J, Dillon J, Kinninmonth A, Sarungi M, Picard F (2012) Blood loss following total knee replacement is reduced when using computer-assisted versus standard methods. Acta Orthop Belg 78(1):75–78PubMed
63.
Zurück zum Zitat Saragaglia D, Chaussard C, Rubens-Duval B (2006) Navigation as a predictor of soft tissue release during 90 cases of computer-assisted total knee arthroplasty. Orthopedics 29(10 Suppl):S137–S138PubMed Saragaglia D, Chaussard C, Rubens-Duval B (2006) Navigation as a predictor of soft tissue release during 90 cases of computer-assisted total knee arthroplasty. Orthopedics 29(10 Suppl):S137–S138PubMed
64.
Zurück zum Zitat Mullaji A, Shetty GM (2009) Computer-assisted total knee arthroplasty for arthritis with extra-articular deformity. J Arthroplast 24(8):1164–1169 Mullaji A, Shetty GM (2009) Computer-assisted total knee arthroplasty for arthritis with extra-articular deformity. J Arthroplast 24(8):1164–1169
Metadaten
Titel
Total knee arthroplasties from the origin to navigation: history, rationale, indications
verfasst von
Dominique Saragaglia
Brice Rubens-Duval
Julia Gaillot
Gabriel Lateur
Régis Pailhé
Publikationsdatum
27.03.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 3/2019
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-018-3913-z

Weitere Artikel der Ausgabe 3/2019

International Orthopaedics 3/2019 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.