Skip to main content
Erschienen in: Current Cardiology Reports 6/2019

01.06.2019 | Structural Heart Disease (RJ Siegel and NC Wunderlich, Section Editors)

Transseptal Puncture: Devices, Techniques, and Considerations for Specific Interventions

verfasst von: Sharan Prakash Sharma, Rahul Nalamasu, Rakesh Gopinathannair, Chandrasekhar Vasamreddy, Dhanunjaya Lakkireddy

Erschienen in: Current Cardiology Reports | Ausgabe 6/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose of Review

Transseptal puncture is a routinely performed interventional cardiology procedure for an array of cardiac diseases. We aimed to review the current status of available devices and techniques of transseptal puncture with consideration to specific interventions.

Recent Findings

Except for a few modifications, devices for transseptal puncture technique has not changed much compared to when it was first described almost 60 years ago. For difficult transseptal puncture, a few newer techniques such as radio frequency needle puncture system have been used but there is lack of robust clinical study. Advanced imaging, such as intracardiac echocardiography and transesophageal echocardiography, has been found to make transseptal puncture safer. A new transseptal approach that incorporates 3D non-fluoroscopic catheter tracking systems has shown promising results in two human studies.

Summary

While various modifications in the transseptal technique tailored to the specific interventions have improved procedural safety, further improvement in existing devices focusing on distinct procedure might be needed in the future.
Literatur
1.
Zurück zum Zitat Ross J, Braunwald E, Morrow AG. Transseptal left atrial puncture; new technique for the measurement of left atrial pressure in man. Am J Cardiol. 1959;3:653–5.CrossRef Ross J, Braunwald E, Morrow AG. Transseptal left atrial puncture; new technique for the measurement of left atrial pressure in man. Am J Cardiol. 1959;3:653–5.CrossRef
2.
Zurück zum Zitat Ross J. Transeptal left heart catheterization: a new method of left atrial puncture. Ann Surg. 1959;149:395–401.CrossRef Ross J. Transeptal left heart catheterization: a new method of left atrial puncture. Ann Surg. 1959;149:395–401.CrossRef
3.
Zurück zum Zitat Alkhouli M, Rihal CS, Holmes DR. Transseptal techniques for emerging structural heart interventions. JACC Cardiovasc Interv. 2016;9:2465–80.CrossRef Alkhouli M, Rihal CS, Holmes DR. Transseptal techniques for emerging structural heart interventions. JACC Cardiovasc Interv. 2016;9:2465–80.CrossRef
4.
Zurück zum Zitat Joshi SD, Chawre HK, Joshi SS. Morphological study of fossa ovalis and its clinical relevance. Indian Heart J. 2016;68:147–52.CrossRef Joshi SD, Chawre HK, Joshi SS. Morphological study of fossa ovalis and its clinical relevance. Indian Heart J. 2016;68:147–52.CrossRef
5.
Zurück zum Zitat O’Brien B, Zafar H, De Freitas S, Sharif F. Transseptal puncture - review of anatomy, techniques, complications and challenges. Int J Cardiol. 2017;233:12–22.CrossRef O’Brien B, Zafar H, De Freitas S, Sharif F. Transseptal puncture - review of anatomy, techniques, complications and challenges. Int J Cardiol. 2017;233:12–22.CrossRef
6.
Zurück zum Zitat Sweeney LJ, Rosenquist GC. The normal anatomy of the atrial septum in the human heart. Am Heart J. 1979;98:194–9.CrossRef Sweeney LJ, Rosenquist GC. The normal anatomy of the atrial septum in the human heart. Am Heart J. 1979;98:194–9.CrossRef
7.
Zurück zum Zitat De Ponti R, Cappato R, Curnis A, et al. Trans-septal catheterization in the electrophysiology laboratory: data from a multicenter survey spanning 12 years. J Am Coll Cardiol. 2006;47:1037–42.CrossRef De Ponti R, Cappato R, Curnis A, et al. Trans-septal catheterization in the electrophysiology laboratory: data from a multicenter survey spanning 12 years. J Am Coll Cardiol. 2006;47:1037–42.CrossRef
8.
Zurück zum Zitat Babaliaros VC, Green JT, Lerakis S, Lloyd M, Block PC. Emerging applications for transseptal left heart catheterization old techniques for new procedures. J Am Coll Cardiol. 2008;51:2116–22.CrossRef Babaliaros VC, Green JT, Lerakis S, Lloyd M, Block PC. Emerging applications for transseptal left heart catheterization old techniques for new procedures. J Am Coll Cardiol. 2008;51:2116–22.CrossRef
9.
Zurück zum Zitat Earley MJ. How to perform a transseptal puncture. Heart. 2009;95:85–92.CrossRef Earley MJ. How to perform a transseptal puncture. Heart. 2009;95:85–92.CrossRef
10.
Zurück zum Zitat Gul EE, Baranchuk A, Glover BM. A guide to transseptal access. Can J Cardiol. 2017;33:544–7.CrossRef Gul EE, Baranchuk A, Glover BM. A guide to transseptal access. Can J Cardiol. 2017;33:544–7.CrossRef
11.
Zurück zum Zitat Klimek-Piotrowska W, Hołda MK, Koziej M, Piątek K, Hołda J. Anatomy of the true interatrial septum for transseptal access to the left atrium. Ann Anat. 2016;205:60–4.CrossRef Klimek-Piotrowska W, Hołda MK, Koziej M, Piątek K, Hołda J. Anatomy of the true interatrial septum for transseptal access to the left atrium. Ann Anat. 2016;205:60–4.CrossRef
12.
Zurück zum Zitat • Kataria V, Berte B, Vandekerckhove Y, Tavernier R, Duytschaever M. Modified transseptal puncture technique in challenging septa: a randomized comparison to conventional technique. Biomed Res Int. 2017;2017:2351925 It shows modified transseptal techniques could allow effective, safe, and time-sparing transseptal puncture in patients when conventional technique fail.PubMedPubMedCentral • Kataria V, Berte B, Vandekerckhove Y, Tavernier R, Duytschaever M. Modified transseptal puncture technique in challenging septa: a randomized comparison to conventional technique. Biomed Res Int. 2017;2017:2351925 It shows modified transseptal techniques could allow effective, safe, and time-sparing transseptal puncture in patients when conventional technique fail.PubMedPubMedCentral
13.
Zurück zum Zitat McWilliams MJ, Tchou P. The use of a standard radiofrequency energy delivery system to facilitate transseptal puncture. J Cardiovasc Electrophysiol. 2009;20:238–40.CrossRef McWilliams MJ, Tchou P. The use of a standard radiofrequency energy delivery system to facilitate transseptal puncture. J Cardiovasc Electrophysiol. 2009;20:238–40.CrossRef
14.
Zurück zum Zitat Capulzini L, Paparella G, Sorgente A, de Asmundis C, Chierchia GB, Sarkozy A, et al. Feasibility, safety, and outcome of a challenging transseptal puncture facilitated by radiofrequency energy delivery: a prospective single-centre study. Europace. 2010;12:662–7.CrossRef Capulzini L, Paparella G, Sorgente A, de Asmundis C, Chierchia GB, Sarkozy A, et al. Feasibility, safety, and outcome of a challenging transseptal puncture facilitated by radiofrequency energy delivery: a prospective single-centre study. Europace. 2010;12:662–7.CrossRef
15.
Zurück zum Zitat Maisano F, La Canna G, Latib A, et al. Transseptal access for MitraClip® procedures using surgical diathermy under echocardiographic guidance. EuroIntervention. 2012;8:579–86.CrossRef Maisano F, La Canna G, Latib A, et al. Transseptal access for MitraClip® procedures using surgical diathermy under echocardiographic guidance. EuroIntervention. 2012;8:579–86.CrossRef
16.
Zurück zum Zitat • Gowda ST, Qureshi AM, Turner D, et al. Transseptal puncture using surgical electrocautery in children and adults with and without complex congenital heart disease. Catheter Cardiovasc Interv. 2017;90:E46–54 This shows radio frequency current delivery using surgical electrocautery for transseptal puncture is a feasible and an effective option in patients requiring transseptal puncture for wide array of conditions.CrossRef • Gowda ST, Qureshi AM, Turner D, et al. Transseptal puncture using surgical electrocautery in children and adults with and without complex congenital heart disease. Catheter Cardiovasc Interv. 2017;90:E46–54 This shows radio frequency current delivery using surgical electrocautery for transseptal puncture is a feasible and an effective option in patients requiring transseptal puncture for wide array of conditions.CrossRef
17.
Zurück zum Zitat Abed HS, Alasady M, Lau DH, Lim HS, Sanders P. Approach to the difficult transseptal: diathermy facilitated left atrial access. Heart Lung Circ. 2012;21:108–12.CrossRef Abed HS, Alasady M, Lau DH, Lim HS, Sanders P. Approach to the difficult transseptal: diathermy facilitated left atrial access. Heart Lung Circ. 2012;21:108–12.CrossRef
18.
Zurück zum Zitat Smelley MP, Shah DP, Weisberg I, et al. Initial experience using a radiofrequency powered transseptal needle. J Cardiovasc Electrophysiol. 2010;21:423–7.CrossRef Smelley MP, Shah DP, Weisberg I, et al. Initial experience using a radiofrequency powered transseptal needle. J Cardiovasc Electrophysiol. 2010;21:423–7.CrossRef
19.
Zurück zum Zitat Esch JJ, Triedman JK, Cecchin F, Alexander ME, Walsh EP. Radiofrequency-assisted transseptal perforation for electrophysiology procedures in children and adults with repaired congenital heart disease. Pacing Clin Electrophysiol. 2013;36:607–11.CrossRef Esch JJ, Triedman JK, Cecchin F, Alexander ME, Walsh EP. Radiofrequency-assisted transseptal perforation for electrophysiology procedures in children and adults with repaired congenital heart disease. Pacing Clin Electrophysiol. 2013;36:607–11.CrossRef
20.
Zurück zum Zitat Radinovic A, Mazzone P, Landoni G, Agricola E, Regazzoli D, Bella PD. Different transseptal puncture for different procedures: optimization of left atrial catheterization guided by transesophageal echocardiography. Ann Card Anaesth. 2016;19:589–93.CrossRef Radinovic A, Mazzone P, Landoni G, Agricola E, Regazzoli D, Bella PD. Different transseptal puncture for different procedures: optimization of left atrial catheterization guided by transesophageal echocardiography. Ann Card Anaesth. 2016;19:589–93.CrossRef
21.
Zurück zum Zitat Fromentin S, Sarrazin J-F, Champagne J, Nault I, Philippon F, Molin F, et al. Prospective comparison between conventional transseptal puncture and transseptal needle puncture with radiofrequency energy. J Interv Card Electrophysiol. 2011;31:237–42.CrossRef Fromentin S, Sarrazin J-F, Champagne J, Nault I, Philippon F, Molin F, et al. Prospective comparison between conventional transseptal puncture and transseptal needle puncture with radiofrequency energy. J Interv Card Electrophysiol. 2011;31:237–42.CrossRef
22.
Zurück zum Zitat Hsu JC, Badhwar N, Gerstenfeld EP, et al. Randomized trial of conventional transseptal needle versus radiofrequency energy needle puncture for left atrial access (the TRAVERSE-LA study). J Am Heart Assoc. 2013;2:e000428.PubMedPubMedCentral Hsu JC, Badhwar N, Gerstenfeld EP, et al. Randomized trial of conventional transseptal needle versus radiofrequency energy needle puncture for left atrial access (the TRAVERSE-LA study). J Am Heart Assoc. 2013;2:e000428.PubMedPubMedCentral
23.
Zurück zum Zitat •• Sharma G, Singh GD, Smith TW, Fan D, Low RI, Rogers JH. Accuracy and procedural characteristics of standard needle compared with radiofrequency needle transseptal puncture for structural heart interventions. Catheter Cardiovasc Interv. 2017;89:E200–6 This study shows that radio frequency needle compared to standard needle is associated with improved outcome when standard needle fails. It is associated with favorable procedural time and degree of septum tenting.CrossRef •• Sharma G, Singh GD, Smith TW, Fan D, Low RI, Rogers JH. Accuracy and procedural characteristics of standard needle compared with radiofrequency needle transseptal puncture for structural heart interventions. Catheter Cardiovasc Interv. 2017;89:E200–6 This study shows that radio frequency needle compared to standard needle is associated with improved outcome when standard needle fails. It is associated with favorable procedural time and degree of septum tenting.CrossRef
24.
Zurück zum Zitat •• Tokuda M, Yamashita S, Matsuo S, et al. Radiofrequency needle for transseptal puncture is associated with lower incidence of thromboembolism during catheter ablation of atrial fibrillation: propensity score-matched analysis. Heart Vessel. 2018;33:1238–44 Interesting findings came from this study. It shows patients undergoing atrial fibrillation ablation with radio frequency needle for transseptal puncture had lower incidence of MRI-confirmed acute cerebral embolism.CrossRef •• Tokuda M, Yamashita S, Matsuo S, et al. Radiofrequency needle for transseptal puncture is associated with lower incidence of thromboembolism during catheter ablation of atrial fibrillation: propensity score-matched analysis. Heart Vessel. 2018;33:1238–44 Interesting findings came from this study. It shows patients undergoing atrial fibrillation ablation with radio frequency needle for transseptal puncture had lower incidence of MRI-confirmed acute cerebral embolism.CrossRef
25.
Zurück zum Zitat Feld GK, Tiongson J, Oshodi G. Particle formation and risk of embolization during transseptal catheterization: comparison of standard transseptal needles and a new radiofrequency transseptal needle. J Interv Card Electrophysiol. 2011;30:31–6.CrossRef Feld GK, Tiongson J, Oshodi G. Particle formation and risk of embolization during transseptal catheterization: comparison of standard transseptal needles and a new radiofrequency transseptal needle. J Interv Card Electrophysiol. 2011;30:31–6.CrossRef
26.
Zurück zum Zitat •• Rogers JH, Stripe BR, Singh GD, Boyd WD, Fan D, Smith TWR. Initial clinical experience with the FlexPoint steerable transseptal needle in left-sided structural heart procedures. Catheter Cardiovasc Interv. 2018;92:792–6 This study presents the initial experience of using steerable needle in 27 patients for transseptal puncture. With real-time adjustable deflection capability, steerable needle was used able to puncture the specific intended part of fossa ovalis without any complications.CrossRef •• Rogers JH, Stripe BR, Singh GD, Boyd WD, Fan D, Smith TWR. Initial clinical experience with the FlexPoint steerable transseptal needle in left-sided structural heart procedures. Catheter Cardiovasc Interv. 2018;92:792–6 This study presents the initial experience of using steerable needle in 27 patients for transseptal puncture. With real-time adjustable deflection capability, steerable needle was used able to puncture the specific intended part of fossa ovalis without any complications.CrossRef
27.
Zurück zum Zitat Bommer WJ, Lee G, Riemenschneider TA, Ikeda RM, Rebeck K, Stobbe D, et al. Laser atrial septostomy. Am Heart J. 1983;106:1152–6.CrossRef Bommer WJ, Lee G, Riemenschneider TA, Ikeda RM, Rebeck K, Stobbe D, et al. Laser atrial septostomy. Am Heart J. 1983;106:1152–6.CrossRef
28.
Zurück zum Zitat Galal O, Weber HP, Enders S, al Watban F, ElSayet RM, Duran C. Transcatheter laser atrial septostomy in rabbits. Int J Cardiol. 1993;42:31–5.CrossRef Galal O, Weber HP, Enders S, al Watban F, ElSayet RM, Duran C. Transcatheter laser atrial septostomy in rabbits. Int J Cardiol. 1993;42:31–5.CrossRef
29.
Zurück zum Zitat Elagha AA, Kocaturk O, Guttman MA, Ozturk C, Kim AH, Burton GW, et al. Real-time MR imaging-guided laser atrial septal puncture in swine. J Vasc Interv Radiol. 2008;19:1347–53.CrossRef Elagha AA, Kocaturk O, Guttman MA, Ozturk C, Kim AH, Burton GW, et al. Real-time MR imaging-guided laser atrial septal puncture in swine. J Vasc Interv Radiol. 2008;19:1347–53.CrossRef
31.
Zurück zum Zitat Daoud EG, Kalbfleisch SJ, Hummel JD. Intracardiac echocardiography to guide transseptal left heart catheterization for radiofrequency catheter ablation. J Cardiovasc Electrophysiol. 1999;10:358–63.CrossRef Daoud EG, Kalbfleisch SJ, Hummel JD. Intracardiac echocardiography to guide transseptal left heart catheterization for radiofrequency catheter ablation. J Cardiovasc Electrophysiol. 1999;10:358–63.CrossRef
32.
Zurück zum Zitat Hung JS, Fu M, Yeh KH, Wu CJ, Wong P. Usefulness of intracardiac echocardiography in complex transseptal catheterization during percutaneous transvenous mitral commissurotomy. Mayo Clin Proc. 1996;71:134–40.CrossRef Hung JS, Fu M, Yeh KH, Wu CJ, Wong P. Usefulness of intracardiac echocardiography in complex transseptal catheterization during percutaneous transvenous mitral commissurotomy. Mayo Clin Proc. 1996;71:134–40.CrossRef
33.
Zurück zum Zitat Szili-Torok T, Kimman G, Theuns D, Res J, Roelandt JR, Jordaens LJ. Transseptal left heart catheterisation guided by intracardiac echocardiography. Heart. 2001;86:E11–111.CrossRef Szili-Torok T, Kimman G, Theuns D, Res J, Roelandt JR, Jordaens LJ. Transseptal left heart catheterisation guided by intracardiac echocardiography. Heart. 2001;86:E11–111.CrossRef
34.
Zurück zum Zitat Citro R, Ducceschi V, Salustri A, Santoro M, Salierno M, Gregorio G. Intracardiac echocardiography to guide transseptal catheterization for radiofrequency catheter ablation of left-sided accessory pathways: two case reports. Cardiovasc Ultrasound. 2004;2:20.CrossRef Citro R, Ducceschi V, Salustri A, Santoro M, Salierno M, Gregorio G. Intracardiac echocardiography to guide transseptal catheterization for radiofrequency catheter ablation of left-sided accessory pathways: two case reports. Cardiovasc Ultrasound. 2004;2:20.CrossRef
35.
Zurück zum Zitat Epstein LM, Smith T, TenHoff H. Nonfluoroscopic transseptal catheterization: safety and efficacy of intracardiac echocardiographic guidance. J Cardiovasc Electrophysiol. 1998;9:625–30.CrossRef Epstein LM, Smith T, TenHoff H. Nonfluoroscopic transseptal catheterization: safety and efficacy of intracardiac echocardiographic guidance. J Cardiovasc Electrophysiol. 1998;9:625–30.CrossRef
36.
Zurück zum Zitat Hanaoka T, Suyama K, Taguchi A, Shimizu W, Kurita T, Aihara N, et al. Shifting of puncture site in the fossa ovalis during radiofrequency catheter ablation: intracardiac echocardiography-guided transseptal left heart catheterization. Jpn Heart J. 2003;44:673–80.CrossRef Hanaoka T, Suyama K, Taguchi A, Shimizu W, Kurita T, Aihara N, et al. Shifting of puncture site in the fossa ovalis during radiofrequency catheter ablation: intracardiac echocardiography-guided transseptal left heart catheterization. Jpn Heart J. 2003;44:673–80.CrossRef
37.
Zurück zum Zitat Matoshvili Z, Bastani H, Bourke T, Braunschweig F, Drca N, Gudmundsson K, et al. Safety of fluoroscopy-guided transseptal approach for ablation of left-sided arrhythmias. Europace. 2017;19:2023–6.CrossRef Matoshvili Z, Bastani H, Bourke T, Braunschweig F, Drca N, Gudmundsson K, et al. Safety of fluoroscopy-guided transseptal approach for ablation of left-sided arrhythmias. Europace. 2017;19:2023–6.CrossRef
38.
Zurück zum Zitat •• Enriquez A, Saenz LC, Rosso R, et al. Use of intracardiac echocardiography in interventional cardiology: working with the anatomy rather than fighting it. Circulation. 2018;137:2278–94 This comprehensive review provides findings about the emerging roles of intracardiac echocardiography in electrophysiology procedures including transseptal puncture.CrossRef •• Enriquez A, Saenz LC, Rosso R, et al. Use of intracardiac echocardiography in interventional cardiology: working with the anatomy rather than fighting it. Circulation. 2018;137:2278–94 This comprehensive review provides findings about the emerging roles of intracardiac echocardiography in electrophysiology procedures including transseptal puncture.CrossRef
39.
Zurück zum Zitat • Mansour M, Afzal MR, Gunda S, et al. Feasibility of transseptal puncture using a nonfluoroscopic catheter tracking system. Pacing Clin Electrophysiol. 2015;38:791–6 This prospective observational study shows transseptal puncture can be successfully performed using non-fluoroscopic catheter tracking system (MediGuide) and that it results in significant reduction in radiation exposure.CrossRef • Mansour M, Afzal MR, Gunda S, et al. Feasibility of transseptal puncture using a nonfluoroscopic catheter tracking system. Pacing Clin Electrophysiol. 2015;38:791–6 This prospective observational study shows transseptal puncture can be successfully performed using non-fluoroscopic catheter tracking system (MediGuide) and that it results in significant reduction in radiation exposure.CrossRef
40.
Zurück zum Zitat Ballesteros G, Ramos Ardanaz P, Neglia R, et al. Mediguide-assisted transseptal puncture without echocardiographic guidance. Pacing Clin Electrophysiol. 2017;40:545–50.CrossRef Ballesteros G, Ramos Ardanaz P, Neglia R, et al. Mediguide-assisted transseptal puncture without echocardiographic guidance. Pacing Clin Electrophysiol. 2017;40:545–50.CrossRef
41.
Zurück zum Zitat Ruisi CP, Brysiewicz N, Asnes JD, et al. Use of intracardiac echocardiography during atrial fibrillation ablation. Pacing Clin Electrophysiol. 2013;36:781–8.CrossRef Ruisi CP, Brysiewicz N, Asnes JD, et al. Use of intracardiac echocardiography during atrial fibrillation ablation. Pacing Clin Electrophysiol. 2013;36:781–8.CrossRef
42.
Zurück zum Zitat Bazaz R, Schwartzman D. Site-selective atrial septal puncture. J Cardiovasc Electrophysiol. 2003;14:196–9.CrossRef Bazaz R, Schwartzman D. Site-selective atrial septal puncture. J Cardiovasc Electrophysiol. 2003;14:196–9.CrossRef
43.
Zurück zum Zitat Okubo K, Kuwahara T, Takigawa M, Tanaka Y, Nakajima J, Watari Y, et al. Impact of anteroinferior transseptal puncture on creation of a complete block at the mitral isthmus in patients with atrial fibrillation. J Interv Card Electrophysiol. 2017;48:317–25.CrossRef Okubo K, Kuwahara T, Takigawa M, Tanaka Y, Nakajima J, Watari Y, et al. Impact of anteroinferior transseptal puncture on creation of a complete block at the mitral isthmus in patients with atrial fibrillation. J Interv Card Electrophysiol. 2017;48:317–25.CrossRef
44.
Zurück zum Zitat Su W, Kowal R, Kowalski M, Metzner A, Svinarich JT, Wheelan K, et al. Best practice guide for cryoballoon ablation in atrial fibrillation: the compilation experience of more than 3000 procedures. Heart Rhythm. 2015;12:1658–66.CrossRef Su W, Kowal R, Kowalski M, Metzner A, Svinarich JT, Wheelan K, et al. Best practice guide for cryoballoon ablation in atrial fibrillation: the compilation experience of more than 3000 procedures. Heart Rhythm. 2015;12:1658–66.CrossRef
45.
Zurück zum Zitat Ellis ER, Culler SD, Simon AW, Reynolds MR. Trends in utilization and complications of catheter ablation for atrial fibrillation in Medicare beneficiaries. Heart Rhythm. 2009;6:1267–73.CrossRef Ellis ER, Culler SD, Simon AW, Reynolds MR. Trends in utilization and complications of catheter ablation for atrial fibrillation in Medicare beneficiaries. Heart Rhythm. 2009;6:1267–73.CrossRef
46.
Zurück zum Zitat Cappato R, Calkins H, Chen S-A, Davies W, Iesaka Y, Kalman J, et al. Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circ Arrhythm Electrophysiol. 2010;3:32–8.CrossRef Cappato R, Calkins H, Chen S-A, Davies W, Iesaka Y, Kalman J, et al. Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circ Arrhythm Electrophysiol. 2010;3:32–8.CrossRef
47.
Zurück zum Zitat Hsu L-F, Jaïs P, Hocini M, et al. Incidence and prevention of cardiac tamponade complicating ablation for atrial fibrillation. Pacing Clin Electrophysiol. 2005;28(Suppl 1):S106–9.CrossRef Hsu L-F, Jaïs P, Hocini M, et al. Incidence and prevention of cardiac tamponade complicating ablation for atrial fibrillation. Pacing Clin Electrophysiol. 2005;28(Suppl 1):S106–9.CrossRef
48.
Zurück zum Zitat Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen SA, et al. 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a report of the Heart Rhythm Society (HRS) task force on catheter and surgical ablation of atrial fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society. Heart Rhythm. 2012;9:632–696.e21.CrossRef Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen SA, et al. 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a report of the Heart Rhythm Society (HRS) task force on catheter and surgical ablation of atrial fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society. Heart Rhythm. 2012;9:632–696.e21.CrossRef
49.
Zurück zum Zitat Naik N. How to perform transeptal puncture. Indian Heart J. 2015;67:70–6.CrossRef Naik N. How to perform transeptal puncture. Indian Heart J. 2015;67:70–6.CrossRef
50.
Zurück zum Zitat Fagundes RL, Mantica M, De Luca L, et al. Safety of single transseptal puncture for ablation of atrial fibrillation: retrospective study from a large cohort of patients. J Cardiovasc Electrophysiol. 2007;18:1277–81.CrossRef Fagundes RL, Mantica M, De Luca L, et al. Safety of single transseptal puncture for ablation of atrial fibrillation: retrospective study from a large cohort of patients. J Cardiovasc Electrophysiol. 2007;18:1277–81.CrossRef
51.
Zurück zum Zitat Freixa X, Tzikas A, Basmadjian A, Garceau P, Ibrahim R. The chicken-wing morphology: an anatomical challenge for left atrial appendage occlusion. J Interv Cardiol. 2013;26:509–14.PubMed Freixa X, Tzikas A, Basmadjian A, Garceau P, Ibrahim R. The chicken-wing morphology: an anatomical challenge for left atrial appendage occlusion. J Interv Cardiol. 2013;26:509–14.PubMed
52.
Zurück zum Zitat Thakkar J, Vasdeki D, Tzikas A, Meier B, Saw J. Incidence, prevention, and management of periprocedural complications of left atrial appendage occlusion. Interv Cardiol Clin. 2018;7:243–52.PubMed Thakkar J, Vasdeki D, Tzikas A, Meier B, Saw J. Incidence, prevention, and management of periprocedural complications of left atrial appendage occlusion. Interv Cardiol Clin. 2018;7:243–52.PubMed
53.
Zurück zum Zitat Urena M, Himbert D, Brochet E, Carrasco JL, Iung B, Nataf P, et al. Transseptal transcatheter mitral valve replacement using balloon-expandable transcatheter heart valves: A Step-by-Step Approach. JACC Cardiovasc Interv. 2017;10:1905–19.CrossRef Urena M, Himbert D, Brochet E, Carrasco JL, Iung B, Nataf P, et al. Transseptal transcatheter mitral valve replacement using balloon-expandable transcatheter heart valves: A Step-by-Step Approach. JACC Cardiovasc Interv. 2017;10:1905–19.CrossRef
54.
Zurück zum Zitat Feldman T, Wasserman HS, Herrmann HC, Gray W, Block PC, Whitlow P, et al. Percutaneous mitral valve repair using the edge-to-edge technique: six-month results of the EVEREST phase I clinical trial. J Am Coll Cardiol. 2005;46:2134–40.CrossRef Feldman T, Wasserman HS, Herrmann HC, Gray W, Block PC, Whitlow P, et al. Percutaneous mitral valve repair using the edge-to-edge technique: six-month results of the EVEREST phase I clinical trial. J Am Coll Cardiol. 2005;46:2134–40.CrossRef
55.
Zurück zum Zitat Chen K, Sang C, Dong J, Ma C. Transseptal puncture through Amplatzer septal occluder device for catheter ablation of atrial fibrillation: use of balloon dilatation technique. J Cardiovasc Electrophysiol. 2012;23:1139–41.CrossRef Chen K, Sang C, Dong J, Ma C. Transseptal puncture through Amplatzer septal occluder device for catheter ablation of atrial fibrillation: use of balloon dilatation technique. J Cardiovasc Electrophysiol. 2012;23:1139–41.CrossRef
56.
Zurück zum Zitat El-Said HG, Ing FF, Grifka RG, et al. 18-year experience with transseptal procedures through baffles, conduits, and other intra-atrial patches. Catheter Cardiovasc Interv. 2000;50:434–9 discussion 440.CrossRef El-Said HG, Ing FF, Grifka RG, et al. 18-year experience with transseptal procedures through baffles, conduits, and other intra-atrial patches. Catheter Cardiovasc Interv. 2000;50:434–9 discussion 440.CrossRef
Metadaten
Titel
Transseptal Puncture: Devices, Techniques, and Considerations for Specific Interventions
verfasst von
Sharan Prakash Sharma
Rahul Nalamasu
Rakesh Gopinathannair
Chandrasekhar Vasamreddy
Dhanunjaya Lakkireddy
Publikationsdatum
01.06.2019
Verlag
Springer US
Erschienen in
Current Cardiology Reports / Ausgabe 6/2019
Print ISSN: 1523-3782
Elektronische ISSN: 1534-3170
DOI
https://doi.org/10.1007/s11886-019-1136-6

Weitere Artikel der Ausgabe 6/2019

Current Cardiology Reports 6/2019 Zur Ausgabe

Ischemic Heart Disease (D Mukherjee, Section Editor)

Mortality and Cardiovascular Disease in Type 1 and Type 2 Diabetes

Lipid Abnormalities and Cardiovascular Prevention (G De Backer, Section Editor)

Is There a Need to Revise Goals in the Management of Dyslipidemias?

Psychological Aspects of Cardiovascular Diseases (A Steptoe, Section Editor)

Psychosocial Factors and Recovery After Acute Myocardial Infarction in Younger Women

Lipid Abnormalities and Cardiovascular Prevention (G De Backer, Section Editor)

Dyslipidemia Profiles in Patients with Peripheral Artery Disease

Structural Heart Disease (RJ Siegel and NC Wunderlich, Section Editors)

Treatment Challenges in Patients with Acute Heart Failure and Severe Aortic Valve Stenosis

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.