Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 7/2015

01.07.2015 | Trauma Surgery

Treatment of patella fracture by claw-like shape memory alloy

verfasst von: Wei Hao, Lugang Zhou, Yujie Sun, Peng Shi, Hongzhi Liu, Xin Wang

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 7/2015

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Titanium-nickel shape memory alloy (Ti-Ni SMA) is characterized by shape-memory effect, super-elasticity, excellent fatigue behavior, corrosion resistance, acceptable biocompatibility and high damping capacity.

Materials and methods

Claw-like Ti-Ni SMA fixator (SMA-claw) has been used to treat transverse fracture of patella. 29 patients (19 males, 10 females) aged from 21 to 71 years old (averaged 43.0 years old) have been received open reduction and internal fixation with SMA-claw from January 2011 to December 2011. After operation, patients have been received gradual knee function exercises, followed by radiographic analysis and Lysholm Knee Score at 1, 2, 3, 6, 9 and 12 months postoperation.

Results

The mean follow-up time was 11.48 months (25 patients finished, 1 lost after 6 months and 3 lost after 9 months). Radiographic bone union occurred at 2 months (7 patients) or 3 months (22 patients). Satisfied range of motion for the knee joint has been observed with 1.90/141.72° (hyperextension/flexion) at 3 months, 4.83/143.97° at 6 months, 4.82/144.82° at 9 months and 5.2/145° at 12 months postsurgery.

Conclusion

The Ti-Ni SMA-claw fixator produced good osteosynthesis effect by continuous recovery stress with relatively simple and minimally invasive handling process, which can be introduced as an alternative to traditional tension band technique for treatment of patellar transverse fracture.
Literatur
1.
Zurück zum Zitat Springorum HP, Siewe J, Dargel J, Schiffer G, Michael JW, Eysel P (2011) Classification and treatment of patella fractures. Orthopade 40(10):877–880PubMedCrossRef Springorum HP, Siewe J, Dargel J, Schiffer G, Michael JW, Eysel P (2011) Classification and treatment of patella fractures. Orthopade 40(10):877–880PubMedCrossRef
2.
Zurück zum Zitat Lee SK, Hwang YS, Choy WS (2014) Horizontal versus vertical orientation of the loop for tension band wiring of transverse patella fractures. Orthopedics 37(3):e265–e271PubMedCrossRef Lee SK, Hwang YS, Choy WS (2014) Horizontal versus vertical orientation of the loop for tension band wiring of transverse patella fractures. Orthopedics 37(3):e265–e271PubMedCrossRef
3.
Zurück zum Zitat Mao N, Liu D, Ni H, Tang H, Zhang Q (2013) Comparison of the cable pin system with conventional open surgery for transverse patella fractures. Clin Orthop Relat Res 471(7):2361–2366PubMedCentralPubMedCrossRef Mao N, Liu D, Ni H, Tang H, Zhang Q (2013) Comparison of the cable pin system with conventional open surgery for transverse patella fractures. Clin Orthop Relat Res 471(7):2361–2366PubMedCentralPubMedCrossRef
4.
Zurück zum Zitat Banks KE, Ambrose CG, Wheeless JS, Tissue CM, Sen M (2013) An alternative patellar fracture fixation: a biomechanical study. J Orthop Trauma 27(6):345–351PubMedCrossRef Banks KE, Ambrose CG, Wheeless JS, Tissue CM, Sen M (2013) An alternative patellar fracture fixation: a biomechanical study. J Orthop Trauma 27(6):345–351PubMedCrossRef
5.
Zurück zum Zitat Domby B, Henderson E, Nayak A, Erdoğan M, Gutierrez S, Santoni BG, Sagi HC (2012) Comparison of cannulated screw with tension band wiring versus compressive cannulated locking bolt and nut device (CompresSURE) in patella fractures-a cadaveric biomechanical study. J Orthop Trauma 26(12):678–683PubMedCrossRef Domby B, Henderson E, Nayak A, Erdoğan M, Gutierrez S, Santoni BG, Sagi HC (2012) Comparison of cannulated screw with tension band wiring versus compressive cannulated locking bolt and nut device (CompresSURE) in patella fractures-a cadaveric biomechanical study. J Orthop Trauma 26(12):678–683PubMedCrossRef
6.
Zurück zum Zitat Li H, Wang W, Liu YJ, Chen W, Zhang Q, Li X, Zhu L, Zhang YZ (2013) Closed patella fracture combined with cruciate ligament injury: a case control study. Chin Med J (Engl) 126(20):3856–3859 Li H, Wang W, Liu YJ, Chen W, Zhang Q, Li X, Zhu L, Zhang YZ (2013) Closed patella fracture combined with cruciate ligament injury: a case control study. Chin Med J (Engl) 126(20):3856–3859
7.
Zurück zum Zitat Thelen S, Schneppendahl J, Jopen E, Eichler C, Koebke J, Schönau E, Hakimi M, Windolf J, Wild M (2012) Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation intransverse patella fractures. Injury 43(8):1290–1295PubMedCrossRef Thelen S, Schneppendahl J, Jopen E, Eichler C, Koebke J, Schönau E, Hakimi M, Windolf J, Wild M (2012) Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation intransverse patella fractures. Injury 43(8):1290–1295PubMedCrossRef
8.
Zurück zum Zitat Smith ST, Cramer KE, Karges DE, Watson JT, Moed BR (1997) Early complications in the operative treatment of patella fractures. J Orthop Trauma 11(3):183–187PubMedCrossRef Smith ST, Cramer KE, Karges DE, Watson JT, Moed BR (1997) Early complications in the operative treatment of patella fractures. J Orthop Trauma 11(3):183–187PubMedCrossRef
9.
Zurück zum Zitat Bassani P, Panseri S, Ruffini A, Montesi M, Ghetti M, Zanotti C, Tampieri A, Tuissi A (2014) Porous NiTi shape memory alloys produced by SHS: microstructure and biocompatibility in comparison with Ti2Ni and TiNi 3. J Mater Sci Mater Med Epub ahead of print Bassani P, Panseri S, Ruffini A, Montesi M, Ghetti M, Zanotti C, Tampieri A, Tuissi A (2014) Porous NiTi shape memory alloys produced by SHS: microstructure and biocompatibility in comparison with Ti2Ni and TiNi 3. J Mater Sci Mater Med Epub ahead of print
10.
Zurück zum Zitat Wang Y, Zheng G, Zhang X, Zhang Y, Xiao S, Wang Z (2010) Comparative analysis between shape memory alloy-based correction and traditional correction technique in pedicle screws constructs for treating severe scoliosis. Eur Spine J 19(3):394–399PubMedCentralPubMedCrossRef Wang Y, Zheng G, Zhang X, Zhang Y, Xiao S, Wang Z (2010) Comparative analysis between shape memory alloy-based correction and traditional correction technique in pedicle screws constructs for treating severe scoliosis. Eur Spine J 19(3):394–399PubMedCentralPubMedCrossRef
11.
Zurück zum Zitat Schindler OS (2012) Basic kinematics and biomechanics of the patellofemoral joint part 2: the patella in total knee arthroplasty. Acta Orthop Belg 78(1):11–29PubMed Schindler OS (2012) Basic kinematics and biomechanics of the patellofemoral joint part 2: the patella in total knee arthroplasty. Acta Orthop Belg 78(1):11–29PubMed
12.
Zurück zum Zitat Müller ME, Allgöwer, Robert Schneider M, Willenegger Hans, Perren SM (1991) Manual of INTERNAL FIXATION: techniques recommended by the AO-ASIF Group. 3rd edn, Springer Müller ME, Allgöwer, Robert Schneider M, Willenegger Hans, Perren SM (1991) Manual of INTERNAL FIXATION: techniques recommended by the AO-ASIF Group. 3rd edn, Springer
13.
Zurück zum Zitat Carpenter JE, Kasman RA, Patel N, Lee ML, Goldstein SA (1997) Biomechanical evaluation of current patella fracture fixation techniques. J Orthop Trauma 11(5):351–356PubMedCrossRef Carpenter JE, Kasman RA, Patel N, Lee ML, Goldstein SA (1997) Biomechanical evaluation of current patella fracture fixation techniques. J Orthop Trauma 11(5):351–356PubMedCrossRef
14.
Zurück zum Zitat Qi L, Chang C, Xin T, Xing PF, Tianfu Y, Gang Z, Jian L (2011) Double fixation of displaced patella fractures using bioabsorbable cannulated lag screws and braided polyester suture tension bands. Injury 42(10):1116–1120PubMedCrossRef Qi L, Chang C, Xin T, Xing PF, Tianfu Y, Gang Z, Jian L (2011) Double fixation of displaced patella fractures using bioabsorbable cannulated lag screws and braided polyester suture tension bands. Injury 42(10):1116–1120PubMedCrossRef
15.
Zurück zum Zitat Tian Y, Zhou F, Ji H, Zhang Z, Guo Y (2011) Cannulated screw and cable are superior to modified tension band in the treatment of transverse patella fractures. Clin Orthop Relat Res 469(12):3429–3435PubMedCentralPubMedCrossRef Tian Y, Zhou F, Ji H, Zhang Z, Guo Y (2011) Cannulated screw and cable are superior to modified tension band in the treatment of transverse patella fractures. Clin Orthop Relat Res 469(12):3429–3435PubMedCentralPubMedCrossRef
16.
Zurück zum Zitat Benjamin J, Bried J, Dohm M, McMurtry M (1987) Biomechanical evaluation of various forms of fixation of transverse patellar fractures. J Orthop Trauma 1(3):219–222PubMedCrossRef Benjamin J, Bried J, Dohm M, McMurtry M (1987) Biomechanical evaluation of various forms of fixation of transverse patellar fractures. J Orthop Trauma 1(3):219–222PubMedCrossRef
18.
Zurück zum Zitat Singh D, Sinha S, Singh H, Jagetia A, Gupta S, Gangoo P, Tandon M (2011) Use of nitinol shape memory alloy staples (NiTi clips) after cervical discoidectomy: minimally invasive instrumentation and long-term results. Minim Invasive Neurosurg 54(4):172–178PubMedCrossRef Singh D, Sinha S, Singh H, Jagetia A, Gupta S, Gangoo P, Tandon M (2011) Use of nitinol shape memory alloy staples (NiTi clips) after cervical discoidectomy: minimally invasive instrumentation and long-term results. Minim Invasive Neurosurg 54(4):172–178PubMedCrossRef
19.
Zurück zum Zitat Mei F, Ren X, Wang W (1997) The biomechanical effect and clinical application of a Ni-Ti shape memory expansion clamp. Spine (Phila Pa 1976) 22(18):2083–2088CrossRef Mei F, Ren X, Wang W (1997) The biomechanical effect and clinical application of a Ni-Ti shape memory expansion clamp. Spine (Phila Pa 1976) 22(18):2083–2088CrossRef
20.
Zurück zum Zitat Han HS, Kim DH, Kang SB (2011) The use of a ti-ni shape memory alloy ring bone fixator during the retrograde nailing of supracondylar femoral fractures. Knee Surg Relat Res 23(4):231–235PubMedCentralPubMedCrossRef Han HS, Kim DH, Kang SB (2011) The use of a ti-ni shape memory alloy ring bone fixator during the retrograde nailing of supracondylar femoral fractures. Knee Surg Relat Res 23(4):231–235PubMedCentralPubMedCrossRef
21.
Zurück zum Zitat Zhang Y, Zhao X, Tang Y, Zhang C, Xu S, Xie Y (2013) Application of Ni-Ti Alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients. BMC Musculoskelet Disord 14(1):355PubMedCentralPubMedCrossRef Zhang Y, Zhao X, Tang Y, Zhang C, Xu S, Xie Y (2013) Application of Ni-Ti Alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients. BMC Musculoskelet Disord 14(1):355PubMedCentralPubMedCrossRef
22.
Zurück zum Zitat Zhang Y, Zhao X, Tang Y, Zhang C, Xu S, Xie Y (2014) Comparative study of comminuted posterior acetabular wall fracture treated with the Acetabular Tridimensional Memory Fixation System. Injury 45(4):725–731PubMedCrossRef Zhang Y, Zhao X, Tang Y, Zhang C, Xu S, Xie Y (2014) Comparative study of comminuted posterior acetabular wall fracture treated with the Acetabular Tridimensional Memory Fixation System. Injury 45(4):725–731PubMedCrossRef
23.
Zurück zum Zitat Xu SG, Zhang CC (2011) Design and clinical application of proximal humerus memory connector. J Mater Eng Perform 20(1):143–146CrossRef Xu SG, Zhang CC (2011) Design and clinical application of proximal humerus memory connector. J Mater Eng Perform 20(1):143–146CrossRef
24.
Zurück zum Zitat Cao LH, Xu SG, Wu YL, Zhang CC (2011) Treatment of nonunion of scaphoid waist with Ni-Ti shape-memory alloy connector and iliac bone graft. J Mater Eng Perform 20(4):629–631CrossRef Cao LH, Xu SG, Wu YL, Zhang CC (2011) Treatment of nonunion of scaphoid waist with Ni-Ti shape-memory alloy connector and iliac bone graft. J Mater Eng Perform 20(4):629–631CrossRef
25.
Zurück zum Zitat Xu SG, Zhang CL, Wang JL (2001) Analysis of Nitinol patellar concentrator for treating patellar fractures by electrometric method. Shanghai J Biomed Eng 22(2):14–16 Xu SG, Zhang CL, Wang JL (2001) Analysis of Nitinol patellar concentrator for treating patellar fractures by electrometric method. Shanghai J Biomed Eng 22(2):14–16
Metadaten
Titel
Treatment of patella fracture by claw-like shape memory alloy
verfasst von
Wei Hao
Lugang Zhou
Yujie Sun
Peng Shi
Hongzhi Liu
Xin Wang
Publikationsdatum
01.07.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 7/2015
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-015-2241-7

Weitere Artikel der Ausgabe 7/2015

Archives of Orthopaedic and Trauma Surgery 7/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.