Abstract

The current version (ver. 7.3) of the popular quantitative coronary analysis system QAngio XA (Medis Medical Imaging System BV, Leiden, the Netherlands) is widely used without evaluating the agreement between the current and older versions in relation to a change of algorithms. The purpose of this study was to assess the equivalence of averages between QAngio XA versions 7.3 and 6.0. Based on the calculated sample size, angiographic images of 100 patients who underwent percutaneous coronary intervention of a single target lesion were randomly selected from two published studies (OUCH-TL: 154 lesions; OUCH-PRO: 160 lesions). The primary endpoint was the minimum lumen diameter (MLD), and the secondary endpoints were the reference diameter (RefD) and length of the stenotic lesion (LL). Two independent analysts measured the same frame using both previous and current versions of QAngio XA. Version-order for each lesion was randomly determined per coronary locations targeted. Data were analysed by using a mixed model that includes random lesion effects and fixed rater effects and reading-order effects. A Bland–Altman plot of parameters showed no large differences between the versions. Differences in parameters were estimated by the mixed model, and the 95% confidence interval of the MLD, RefD, and LL estimates was from −0.045 to −0.0001 mm, from −0.040 to 0.006 mm, and from −1.08 to 0.46 mm, respectively, compared with the predefined non-inferiority margin of ±0.2 mm. Measurements of MLD and RefD using QAngio XA showed no major systematic differences between versions.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Scanlon PJ, Faxon DP, Audet AM, Carabello B, Dehmer GJ, Eagle KA, Legako RD, Leon DF, Murray JA, Nissen SE, Pepine CJ, Watson RM, Ritchie JL, Gibbons RJ, Cheitlin MD, Gardner TJ, Garson A Jr, Russell RO Jr, Ryan TJ, Smith SC Jr (1999) ACC/AHA guidelines for coronary angiography. A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Coronary Angiography). Developed in collaboration with the Society for Cardiac Angiography and Interventions. J Am Coll Cardiol 33(6):1756–1824CrossRefPubMed Scanlon PJ, Faxon DP, Audet AM, Carabello B, Dehmer GJ, Eagle KA, Legako RD, Leon DF, Murray JA, Nissen SE, Pepine CJ, Watson RM, Ritchie JL, Gibbons RJ, Cheitlin MD, Gardner TJ, Garson A Jr, Russell RO Jr, Ryan TJ, Smith SC Jr (1999) ACC/AHA guidelines for coronary angiography. A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Coronary Angiography). Developed in collaboration with the Society for Cardiac Angiography and Interventions. J Am Coll Cardiol 33(6):1756–1824CrossRefPubMed
2.
Zurück zum Zitat Desmet W, De Scheerder I, Beatt K, Huehns T, Piessens J (1995) In vivo comparison of different quantitative edge detection systems used for measuring coronary arterial diameters. Cathet Cardiovasc Diagn 34(1):72–80; discussion 81CrossRefPubMed Desmet W, De Scheerder I, Beatt K, Huehns T, Piessens J (1995) In vivo comparison of different quantitative edge detection systems used for measuring coronary arterial diameters. Cathet Cardiovasc Diagn 34(1):72–80; discussion 81CrossRefPubMed
3.
Zurück zum Zitat Gottsauner-Wolf M, Sochor H, Moertl D, Gwechenberger M, Stockenhuber F, Probst P (1996) Assessing coronary stenosis. Quantitative coronary angiography versus visual estimation from cine-film or pharmacological stress perfusion images. Eur Heart J 17(8):1167–1174CrossRefPubMed Gottsauner-Wolf M, Sochor H, Moertl D, Gwechenberger M, Stockenhuber F, Probst P (1996) Assessing coronary stenosis. Quantitative coronary angiography versus visual estimation from cine-film or pharmacological stress perfusion images. Eur Heart J 17(8):1167–1174CrossRefPubMed
5.
Zurück zum Zitat Dietz U, Rupprecht HJ, Brennecke R, Fritsch HP, Woltmann J, Blankenberg S, Meyer J (1997) Comparison of QCA systems. Int J Card Imaging 13(4):271–280CrossRefPubMed Dietz U, Rupprecht HJ, Brennecke R, Fritsch HP, Woltmann J, Blankenberg S, Meyer J (1997) Comparison of QCA systems. Int J Card Imaging 13(4):271–280CrossRefPubMed
6.
Zurück zum Zitat Lansky AJ, Popma JJ, Cutlip D, Ho KK, Abizaid AS, Saucedo J, Zhang Y, Senerchia C, Kuntz RE, Leon MB, Baim DS (1999) Comparative analysis of early and late angiographic outcomes using two quantitative algorithms in the Balloon versus Optimal Atherectomy Trial (BOAT). Am J Cardiol 83(12):1611–1616CrossRefPubMed Lansky AJ, Popma JJ, Cutlip D, Ho KK, Abizaid AS, Saucedo J, Zhang Y, Senerchia C, Kuntz RE, Leon MB, Baim DS (1999) Comparative analysis of early and late angiographic outcomes using two quantitative algorithms in the Balloon versus Optimal Atherectomy Trial (BOAT). Am J Cardiol 83(12):1611–1616CrossRefPubMed
7.
Zurück zum Zitat Keane D, Haase J, Slager CJ, Montauban van Swijndregt E, Lehmann KG, Ozaki Y, di Mario C, Kirkeeide R, Serruys PW (1995) Comparative validation of quantitative coronary angiography systems. Results and implications from a multicenter study using a standardized approach. Circulation 91(8):2174–2183CrossRefPubMed Keane D, Haase J, Slager CJ, Montauban van Swijndregt E, Lehmann KG, Ozaki Y, di Mario C, Kirkeeide R, Serruys PW (1995) Comparative validation of quantitative coronary angiography systems. Results and implications from a multicenter study using a standardized approach. Circulation 91(8):2174–2183CrossRefPubMed
8.
Zurück zum Zitat Kozuma K, Otsuka M, Ikari Y, Uehara Y, Yokoi H, Sano K, Tanabe K, Hibi K, Yamane M, Ishiwata S, Ohta H, Yamauchi Y, Suematsu N, Nakayama M, Inoue N, Kyono H, Suzuki N, Isshiki T (2015) Clinical and angiographic outcomes of paclitaxel-eluting coronary stent implantation in hemodialysis patients: a prospective multicenter registry: The OUCH-TL study (outcome in hemodialysis of TAXUS Liberte). J Cardiol 66(6):502–508. doi:10.1016/j.jjcc.2015.03.008 CrossRefPubMed Kozuma K, Otsuka M, Ikari Y, Uehara Y, Yokoi H, Sano K, Tanabe K, Hibi K, Yamane M, Ishiwata S, Ohta H, Yamauchi Y, Suematsu N, Nakayama M, Inoue N, Kyono H, Suzuki N, Isshiki T (2015) Clinical and angiographic outcomes of paclitaxel-eluting coronary stent implantation in hemodialysis patients: a prospective multicenter registry: The OUCH-TL study (outcome in hemodialysis of TAXUS Liberte). J Cardiol 66(6):502–508. doi:10.​1016/​j.​jjcc.​2015.​03.​008 CrossRefPubMed
10.
Zurück zum Zitat Ikari Y, Tanabe K, Koyama Y, Kozuma K, Sano K, Isshiki T, Katsuki T, Kimura K, Yamane M, Takahashi N, Hibi K, Hasegawa K, Ishiwata S, Kiyooka T, Yokoi H, Uehara Y, Hara K (2012) Sirolimus eluting coronary stent implantation in patients on maintenance hemodialysis: the OUCH study (outcome of cypher stent inhemodialysis patients). Circ J 76(8):1856–1863CrossRefPubMed Ikari Y, Tanabe K, Koyama Y, Kozuma K, Sano K, Isshiki T, Katsuki T, Kimura K, Yamane M, Takahashi N, Hibi K, Hasegawa K, Ishiwata S, Kiyooka T, Yokoi H, Uehara Y, Hara K (2012) Sirolimus eluting coronary stent implantation in patients on maintenance hemodialysis: the OUCH study (outcome of cypher stent inhemodialysis patients). Circ J 76(8):1856–1863CrossRefPubMed
11.
Zurück zum Zitat Reiber JH, van der Zwet PM, Koning G, von Land CD, van Meurs B, Gerbrands JJ, Buis B, van Voorthuisen AE (1993) Accuracy and precision of quantitative digital coronary arteriography: observer-, short-, and medium-term variabilities. Cathet Cardiovasc Diagn 28(3):187–198CrossRefPubMed Reiber JH, van der Zwet PM, Koning G, von Land CD, van Meurs B, Gerbrands JJ, Buis B, van Voorthuisen AE (1993) Accuracy and precision of quantitative digital coronary arteriography: observer-, short-, and medium-term variabilities. Cathet Cardiovasc Diagn 28(3):187–198CrossRefPubMed
12.
Zurück zum Zitat Serruys PW, Foley DP, De Feyter PJ (1994) Quantitative coronary angiography in clinical practice. Developments in cardiovascular medicine, vol 145. Kluwer Academic Publishers, DordrechtCrossRef Serruys PW, Foley DP, De Feyter PJ (1994) Quantitative coronary angiography in clinical practice. Developments in cardiovascular medicine, vol 145. Kluwer Academic Publishers, DordrechtCrossRef
13.
Zurück zum Zitat Nakamura M, Kotani J, Kozuma K, Uchida T, Iwabuchi M, Muramatsu T, Hirayama H, Fujii K, Saito S (2011) Effectiveness of paclitaxel-eluting stents in complex clinical patients—Insights from the TAXUS Japan Postmarket surveillance study. Circ J 75(11):2573–2580CrossRefPubMed Nakamura M, Kotani J, Kozuma K, Uchida T, Iwabuchi M, Muramatsu T, Hirayama H, Fujii K, Saito S (2011) Effectiveness of paclitaxel-eluting stents in complex clinical patients—Insights from the TAXUS Japan Postmarket surveillance study. Circ J 75(11):2573–2580CrossRefPubMed
14.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310CrossRefPubMed Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310CrossRefPubMed
15.
Zurück zum Zitat Puricel S, Arroyo D, Corpataux N, Baeriswyl G, Lehmann S, Kallinikou Z, Muller O, Allard L, Stauffer JC, Togni M, Goy JJ, Cook S (2015) Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds. J Am Coll Cardiol 65(8):791–801. doi:10.1016/j.jacc.2014.12.017 CrossRefPubMed Puricel S, Arroyo D, Corpataux N, Baeriswyl G, Lehmann S, Kallinikou Z, Muller O, Allard L, Stauffer JC, Togni M, Goy JJ, Cook S (2015) Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds. J Am Coll Cardiol 65(8):791–801. doi:10.​1016/​j.​jacc.​2014.​12.​017 CrossRefPubMed
16.
Zurück zum Zitat Alfonso F, Perez-Vizcayno MJ, Cardenas A, Garcia Del Blanco B, Seidelberger B, Iniguez A, Gomez-Recio M, Masotti M, Velazquez MT, Sanchis J, Garcia-Touchard A, Zueco J, Bethencourt A, Melgares R, Cequier A, Dominguez A, Mainar V, Lopez-Minguez JR, Moreu J, Marti V, Moreno R, Jimenez-Quevedo P, Gonzalo N, Fernandez C, Macaya C (2014) A randomized comparison of drug-eluting balloon versus everolimus-eluting stent in patients with bare-metal stent-in-stent restenosis: the RIBS V Clinical Trial (Restenosis Intra-stent of Bare Metal Stents: paclitaxel-eluting balloon vs. everolimus-eluting stent). J Am Coll Cardiol 63(14):1378–1386. doi:10.1016/j.jacc.2013.12.006 CrossRefPubMed Alfonso F, Perez-Vizcayno MJ, Cardenas A, Garcia Del Blanco B, Seidelberger B, Iniguez A, Gomez-Recio M, Masotti M, Velazquez MT, Sanchis J, Garcia-Touchard A, Zueco J, Bethencourt A, Melgares R, Cequier A, Dominguez A, Mainar V, Lopez-Minguez JR, Moreu J, Marti V, Moreno R, Jimenez-Quevedo P, Gonzalo N, Fernandez C, Macaya C (2014) A randomized comparison of drug-eluting balloon versus everolimus-eluting stent in patients with bare-metal stent-in-stent restenosis: the RIBS V Clinical Trial (Restenosis Intra-stent of Bare Metal Stents: paclitaxel-eluting balloon vs. everolimus-eluting stent). J Am Coll Cardiol 63(14):1378–1386. doi:10.​1016/​j.​jacc.​2013.​12.​006 CrossRefPubMed
17.
Zurück zum Zitat Park KW, Chae IH, Lim DS, Han KR, Yang HM, Lee HY, Kang HJ, Koo BK, Ahn T, Yoon JH, Jeong MH, Hong TJ, Chung WY, Jo SH, Choi YJ, Hur SH, Kwon HM, Jeon DW, Kim BO, Park SH, Lee NH, Jeon HK, Gwon HC, Jang YS, Kim HS (2011) Everolimus-eluting versus sirolimus-eluting stents in patients undergoing percutaneous coronary intervention: the EXCELLENT (Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss After Stenting) randomized trial. J Am Coll Cardiol 58(18):1844–1854. doi:10.1016/j.jacc.2011.07.031 CrossRefPubMed Park KW, Chae IH, Lim DS, Han KR, Yang HM, Lee HY, Kang HJ, Koo BK, Ahn T, Yoon JH, Jeong MH, Hong TJ, Chung WY, Jo SH, Choi YJ, Hur SH, Kwon HM, Jeon DW, Kim BO, Park SH, Lee NH, Jeon HK, Gwon HC, Jang YS, Kim HS (2011) Everolimus-eluting versus sirolimus-eluting stents in patients undergoing percutaneous coronary intervention: the EXCELLENT (Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss After Stenting) randomized trial. J Am Coll Cardiol 58(18):1844–1854. doi:10.​1016/​j.​jacc.​2011.​07.​031 CrossRefPubMed
18.
Zurück zum Zitat Kim WJ, Lee SW, Park SW, Kim YH, Yun SC, Lee JY, Park DW, Kang SJ, Lee CW, Lee JH, Choi SW, Seong IW, Lee BK, Lee NH, Cho YH, Shin WY, Lee SJ, Lee SW, Hyon MS, Bang DW, Park WJ, Kim HS, Chae JK, Lee K, Park HK, Park CB, Lee SG, Kim MK, Park KH, Choi YJ, Cheong SS, Yang TH, Jang JS, Her SH, Park SJ (2011) Randomized comparison of everolimus-eluting stent versus sirolimus-eluting stent implantation for de novo coronary artery disease in patients with diabetes mellitus (ESSENCE-DIABETES): results from the ESSENCE-DIABETES trial. Circulation 124(8):886–892. doi:10.1161/circulationaha.110.015453 CrossRefPubMed Kim WJ, Lee SW, Park SW, Kim YH, Yun SC, Lee JY, Park DW, Kang SJ, Lee CW, Lee JH, Choi SW, Seong IW, Lee BK, Lee NH, Cho YH, Shin WY, Lee SJ, Lee SW, Hyon MS, Bang DW, Park WJ, Kim HS, Chae JK, Lee K, Park HK, Park CB, Lee SG, Kim MK, Park KH, Choi YJ, Cheong SS, Yang TH, Jang JS, Her SH, Park SJ (2011) Randomized comparison of everolimus-eluting stent versus sirolimus-eluting stent implantation for de novo coronary artery disease in patients with diabetes mellitus (ESSENCE-DIABETES): results from the ESSENCE-DIABETES trial. Circulation 124(8):886–892. doi:10.​1161/​circulationaha.​110.​015453 CrossRefPubMed
19.
Zurück zum Zitat Park KW, Yoon JH, Kim JS, Hahn JY, Cho YS, Chae IH, Gwon HC, Ahn T, Oh BH, Park JE, Shim WH, Shin EK, Jang YS, Kim HS (2009) Efficacy of Xience/promus versus Cypher in rEducing Late Loss after stENTing (EXCELLENT) trial: study design and rationale of a Korean multicenter prospective randomized trial. Am Heart J 157(5):811–817.e811. doi:10.1016/j.ahj.2009.02.008 CrossRefPubMed Park KW, Yoon JH, Kim JS, Hahn JY, Cho YS, Chae IH, Gwon HC, Ahn T, Oh BH, Park JE, Shim WH, Shin EK, Jang YS, Kim HS (2009) Efficacy of Xience/promus versus Cypher in rEducing Late Loss after stENTing (EXCELLENT) trial: study design and rationale of a Korean multicenter prospective randomized trial. Am Heart J 157(5):811–817.e811. doi:10.​1016/​j.​ahj.​2009.​02.​008 CrossRefPubMed
20.
Zurück zum Zitat Stone GW, Midei M, Newman W, Sanz M, Hermiller JB, Williams J, Farhat N, Mahaffey KW, Cutlip DE, Fitzgerald PJ, Sood P, Su X, Lansky AJ (2008) Comparison of an everolimus-eluting stent and a paclitaxel-eluting stent in patients with coronary artery disease: a randomized trial. Jama 299(16):1903–1913. doi:10.1001/jama.299.16.1903 CrossRefPubMed Stone GW, Midei M, Newman W, Sanz M, Hermiller JB, Williams J, Farhat N, Mahaffey KW, Cutlip DE, Fitzgerald PJ, Sood P, Su X, Lansky AJ (2008) Comparison of an everolimus-eluting stent and a paclitaxel-eluting stent in patients with coronary artery disease: a randomized trial. Jama 299(16):1903–1913. doi:10.​1001/​jama.​299.​16.​1903 CrossRefPubMed
21.
Zurück zum Zitat Klein JL, Hoff J, Peifer J, Folks R, Cooke CD, King Iii S, Garcia E (1998) A quantitative evaluation of the three dimensional reconstruction of patients’ coronary arteries. Int J Card Imaging 14(2):75–87. doi:10.1023/A:1005903705300 CrossRefPubMed Klein JL, Hoff J, Peifer J, Folks R, Cooke CD, King Iii S, Garcia E (1998) A quantitative evaluation of the three dimensional reconstruction of patients’ coronary arteries. Int J Card Imaging 14(2):75–87. doi:10.​1023/​A:​1005903705300 CrossRefPubMed
22.
Zurück zum Zitat Agostoni P, Biondi-Zoccai G, Van Langenhove G, Cornelis K, Vermeersch P, Convens C, Vassanelli C, Van Den Heuvel P, Van Den Branden F, Verheye S (2008) Comparison of assessment of native coronary arteries by standard versus three-dimensional coronary angiography. Am J Cardiol 102(3):272–279. doi:10.1016/j.amjcard.2008.03.048 CrossRefPubMed Agostoni P, Biondi-Zoccai G, Van Langenhove G, Cornelis K, Vermeersch P, Convens C, Vassanelli C, Van Den Heuvel P, Van Den Branden F, Verheye S (2008) Comparison of assessment of native coronary arteries by standard versus three-dimensional coronary angiography. Am J Cardiol 102(3):272–279. doi:10.​1016/​j.​amjcard.​2008.​03.​048 CrossRefPubMed
23.
Zurück zum Zitat Gradaus R, Mathies K, Breithardt G, Böcker D (2006) Clinical assessment of a new real time 3D quantitative coronary angiography system: evaluation in stented vessel segments. Cathet Cardiovasc Interv 68(1):44–49. doi:10.1002/ccd.20775 CrossRef Gradaus R, Mathies K, Breithardt G, Böcker D (2006) Clinical assessment of a new real time 3D quantitative coronary angiography system: evaluation in stented vessel segments. Cathet Cardiovasc Interv 68(1):44–49. doi:10.​1002/​ccd.​20775 CrossRef
24.
Zurück zum Zitat Tuinenburg JC, Janssen JP, Kooistra R, Koning G, Corral MD, Lansky AJ, Reiber JH (2013) Clinical validation of the new T- and Y-shape models for the quantitative analysis of coronary bifurcations: an interobserver variability study. Cathet Cardiovasc Interv 81(6):E225–E236. doi:10.1002/ccd.24510 CrossRef Tuinenburg JC, Janssen JP, Kooistra R, Koning G, Corral MD, Lansky AJ, Reiber JH (2013) Clinical validation of the new T- and Y-shape models for the quantitative analysis of coronary bifurcations: an interobserver variability study. Cathet Cardiovasc Interv 81(6):E225–E236. doi:10.​1002/​ccd.​24510 CrossRef
26.
Zurück zum Zitat Ishibashi Y, Grundeken MJ, Nakatani S, Iqbal J, Morel MA, Genereux P, Girasis C, Wentzel JJ, Garcia-Garcia HM, Onuma Y, Serruys PW (2015) In vitro validation and comparison of different software packages or algorithms for coronary bifurcation analysis using calibrated phantoms: implications for clinical practice and research of bifurcation stenting. Cathet Cardiovasc Interv 85(4):554–563. doi:10.1002/ccd.25618 CrossRef Ishibashi Y, Grundeken MJ, Nakatani S, Iqbal J, Morel MA, Genereux P, Girasis C, Wentzel JJ, Garcia-Garcia HM, Onuma Y, Serruys PW (2015) In vitro validation and comparison of different software packages or algorithms for coronary bifurcation analysis using calibrated phantoms: implications for clinical practice and research of bifurcation stenting. Cathet Cardiovasc Interv 85(4):554–563. doi:10.​1002/​ccd.​25618 CrossRef
27.
Zurück zum Zitat Gelman A, Hill J (2006) Data analysis using regression and multilevel/hierarchical models. Cambridge University Press, Cambridge Gelman A, Hill J (2006) Data analysis using regression and multilevel/hierarchical models. Cambridge University Press, Cambridge
Metadaten
Titel
Two-by-two cross-over study to evaluate agreement between versions of a quantitative coronary analysis system (QAngio XA)
verfasst von
Kayoko Kozuma
Kosuke Kashiwabara
Tomohiro Shinozaki
Ken Kozuma
Koji Oba
Yutaka Matsuyama
Publikationsdatum
21.01.2017
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 6/2017
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-017-1068-4

Weitere Artikel der Ausgabe 6/2017

The International Journal of Cardiovascular Imaging 6/2017 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.