Abstract

In this study, Elman recurrent neural networks have been defined by using conjugate gradient algorithm in order to determine the depth of anesthesia in the continuation stage of the anesthesia and to estimate the amount of medicine to be applied at that moment. The feed forward neural networks are also used for comparison. The conjugate gradient algorithm is compared with back propagation (BP) for training of the neural Networks. The applied artificial neural network is composed of three layers, namely the input layer, the hidden layer and the output layer. The nonlinear activation function sigmoid (sigmoid function) has been used in the hidden layer and the output layer. EEG data has been recorded with Nihon Kohden 9200 brand 22-channel EEG device. The international 8-channel bipolar 10–20 montage system (8 TB-b system) has been used in assembling the recording electrodes. EEG data have been recorded by being sampled once in every 2 milliseconds. The artificial neural network has been designed so as to have 60 neurons in the input layer, 30 neurons in the hidden layer and 1 neuron in the output layer. The values of the power spectral density (PSD) of 10-second EEG segments which correspond to the 1–50 Hz frequency range; the ratio of the total power of PSD values of the EEG segment at that moment in the same range to the total of PSD values of EEG segment taken prior to the anesthesia.
Literatur
1.
Zurück zum Zitat Muthuswamy, J., and Roy, R. J., The use of fuzzy integrals and bispectral analysis of the electroencephalogram to predict movement under anesthesia. IEEE trans. biomed. eng. 46 (3)291–99, 1999.CrossRef Muthuswamy, J., and Roy, R. J., The use of fuzzy integrals and bispectral analysis of the electroencephalogram to predict movement under anesthesia. IEEE trans. biomed. eng. 46 (3)291–99, 1999.CrossRef
2.
Zurück zum Zitat Aydın, A., Çömelekoğlu, Ü., Koçak, Z., Özge, A., Atıcı, Ş., Oral, U., The hemodynamic effect of remifentanil on stress response to tracheal, intubation : correlations with quantitative EEG analysis. Bulletin of Clinical Psychopharmacology. 11(4). 2001. Aydın, A., Çömelekoğlu, Ü., Koçak, Z., Özge, A., Atıcı, Ş., Oral, U., The hemodynamic effect of remifentanil on stress response to tracheal, intubation : correlations with quantitative EEG analysis. Bulletin of Clinical Psychopharmacology. 11(4). 2001.
3.
Zurück zum Zitat Da Silva, L., EEG analysis: Theory and Practice. In: Niedermayer, E., and Da Silva, L. (Eds.), Electroencephalography basic principles, clinical applications, and related fields, 4th edition. Lippincott Williams & Wilkins, USA, pp. 1135–58, 1999. Da Silva, L., EEG analysis: Theory and Practice. In: Niedermayer, E., and Da Silva, L. (Eds.), Electroencephalography basic principles, clinical applications, and related fields, 4th edition. Lippincott Williams & Wilkins, USA, pp. 1135–58, 1999.
4.
Zurück zum Zitat James, C. J., Jones, R. D., Bones, P. J., and Carroll, G. J., Detection of epileptiform discharges in the EEG by a hybrid system comprising mimetic, self-organized artificial neural network, and fuzzy logic stages. J. Int. Fed Clin Neurophysiology. 110 (12)2049–2063, 1999.CrossRef James, C. J., Jones, R. D., Bones, P. J., and Carroll, G. J., Detection of epileptiform discharges in the EEG by a hybrid system comprising mimetic, self-organized artificial neural network, and fuzzy logic stages. J. Int. Fed Clin Neurophysiology. 110 (12)2049–2063, 1999.CrossRef
5.
Zurück zum Zitat Arıkan, M. K., psychiatric Electrophysiology, Lilly medicine stock company. publication, s. 14–20. 1998. Arıkan, M. K., psychiatric Electrophysiology, Lilly medicine stock company. publication, s. 14–20. 1998.
6.
Zurück zum Zitat Iselin-Chaves, I. A., Flaishon, R., Sebel, P. S., et al., The effect of the interaction of Propofol and Alfentanil on recall, loss of consciousness, and the Bispectral index. Anesth. Analg. 87:949–955, 1998. doi:10.1097/00000539-199810000-00038.CrossRef Iselin-Chaves, I. A., Flaishon, R., Sebel, P. S., et al., The effect of the interaction of Propofol and Alfentanil on recall, loss of consciousness, and the Bispectral index. Anesth. Analg. 87:949–955, 1998. doi:10.​1097/​00000539-199810000-00038.CrossRef
7.
Zurück zum Zitat Gotman, S. Y., Pasupathy, J., Flanagan, A., Rosenblatt, D., and Gottesman, B., An expert system for EEG monitoring in the pediatric intensive care unit. Electroencephalogr. clin. neurophysiol.. 106 (6)488–500, 1998.CrossRef Gotman, S. Y., Pasupathy, J., Flanagan, A., Rosenblatt, D., and Gottesman, B., An expert system for EEG monitoring in the pediatric intensive care unit. Electroencephalogr. clin. neurophysiol.. 106 (6)488–500, 1998.CrossRef
8.
Zurück zum Zitat Ortolani, O., Conti, A., Di Filippo, A., Adembri, C., Moraldi, E., Evangelisti, A., Maggini, M., and Roberts, S. J., EEG signal processing in anaesthesia. Use of a neural network technique for monitoring depth of anaesthesia. Br. J. Anaesth. 88 (5)644–648, 2002. doi:10.1093/bja/88.5.644.CrossRef Ortolani, O., Conti, A., Di Filippo, A., Adembri, C., Moraldi, E., Evangelisti, A., Maggini, M., and Roberts, S. J., EEG signal processing in anaesthesia. Use of a neural network technique for monitoring depth of anaesthesia. Br. J. Anaesth. 88 (5)644–648, 2002. doi:10.​1093/​bja/​88.​5.​644.CrossRef
9.
Zurück zum Zitat Jiao, L., et al (eds.): Using Back Propagation Feedback Neural Networks and Recurrence Quantification Analysis of EEGs Predict Responses to Incision During Anesthesia, ICNC 2006, Part II, LNCS 4222, pp.364–373, 2006. Jiao, L., et al (eds.): Using Back Propagation Feedback Neural Networks and Recurrence Quantification Analysis of EEGs Predict Responses to Incision During Anesthesia, ICNC 2006, Part II, LNCS 4222, pp.364–373, 2006.
10.
Zurück zum Zitat Riedmiller, M., Braun, H., A Direct Adaptive Method for Faster backpropagation learning: The RPROP Algorithm, Proceedings of the IEEE Int. Conf. On Neural Networks, San Francisco, CA, March 28, 1993. Riedmiller, M., Braun, H., A Direct Adaptive Method for Faster backpropagation learning: The RPROP Algorithm, Proceedings of the IEEE Int. Conf. On Neural Networks, San Francisco, CA, March 28, 1993.
12.
Zurück zum Zitat Hagan, M. T., Demuth, H. B., and Beale, M. H., Neural network design. Vol. 17(2). pp. 273–78, Boston, MA: PWS, 1996. Hagan, M. T., Demuth, H. B., and Beale, M. H., Neural network design. Vol. 17(2). pp. 273–78, Boston, MA: PWS, 1996.
13.
Zurück zum Zitat Temurtas, F., Gunturkun, R., Yumusak, N., and Temurtas, H., Harmonic detection using feed forward and recurrent neural networks for active filters. Electric Power. Syst. Res. 72:33–40, 2004.CrossRef Temurtas, F., Gunturkun, R., Yumusak, N., and Temurtas, H., Harmonic detection using feed forward and recurrent neural networks for active filters. Electric Power. Syst. Res. 72:33–40, 2004.CrossRef
14.
Zurück zum Zitat Temurtas, F., Gunturkun, R., Yumusak, N., Temurtas, H., and Unsal, A., An application of elman’s recurrent neural networks to harmonic detection, IEA-AIE 04. Lect. Notes Artif. Intell. 3029:1043–1052, 2004. Temurtas, F., Gunturkun, R., Yumusak, N., Temurtas, H., and Unsal, A., An application of elman’s recurrent neural networks to harmonic detection, IEA-AIE 04. Lect. Notes Artif. Intell. 3029:1043–1052, 2004.
Metadaten
Titel
Using Elman Recurrent Neural Networks with Conjugate Gradient Algorithm in Determining the Anesthetic the Amount of Anesthetic Medicine to Be Applied
verfasst von
Rüştü Güntürkün
Publikationsdatum
01.08.2010
Verlag
Springer US
Erschienen in
Journal of Medical Systems / Ausgabe 4/2010
Print ISSN: 0148-5598
Elektronische ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-009-9260-2

Weitere Artikel der Ausgabe 4/2010

Journal of Medical Systems 4/2010 Zur Ausgabe