Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 12/2013

01.12.2013 | Knee

Variations in ankle registration using two different anatomic landmarks: a radiographic study

verfasst von: Eduardo M. Suero, Mustafa Citak, Charles Claps, Andrew D. Pearle, Christopher Plaskos

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 12/2013

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To quantify the average deviation in tibial mechanical axis registration when registering the ankle centre using (a) the extreme medial and lateral points and (b) the most distal points, of the respective malleoli, and to identify whether body mass index (BMI) had any significant effect on mechanical axis registration error.

Methods

The preoperative standing hip-knee-ankle radiographs of 40 patients who underwent navigated TKR at our institution were reviewed. The divergence from the anatomic ankle centre in degrees and millimetres was compared when using the Extremes Midpoint and the Distal Midpoint techniques.

Results

No significant divergence was measured with either the Extremes Midpoint (0.2° lateral, SD = 0.5°; 1.1 mm lateral, SD = 2.6 mm) or the Distal Midpoint (0.2° lateral, SD = 0.6°; 1.7 mm lateral, SD = 2.3 mm) techniques. BMI had no significant effect on these differences.

Conclusions

Both the Extremes Midpoint and the Distal Midpoint techniques offer accurate registration of the ankle centre. BMI does not seem to affect the registration of the ankle centre with either technique. The findings of this study will help knee surgeons when choosing an ankle registration technique. These results may also lead to more accurate knee replacement navigation systems.

Level of evidence

III.
Literatur
1.
Zurück zum Zitat Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Jt Surg Br 86(5):682–687CrossRef Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Jt Surg Br 86(5):682–687CrossRef
2.
Zurück zum Zitat Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34PubMedCrossRef Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE (2004) Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res 428:26–34PubMedCrossRef
3.
Zurück zum Zitat Bolognesi M, Hofmann A (2005) Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res 440:162–169PubMedCrossRef Bolognesi M, Hofmann A (2005) Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res 440:162–169PubMedCrossRef
4.
Zurück zum Zitat Callaghan JJ, Liu SS, Warth LC (2006) Computer-assisted surgery: a wine before its time—in the affirmative. J Arthroplasty 21(4 Suppl 1):27–28PubMedCrossRef Callaghan JJ, Liu SS, Warth LC (2006) Computer-assisted surgery: a wine before its time—in the affirmative. J Arthroplasty 21(4 Suppl 1):27–28PubMedCrossRef
5.
Zurück zum Zitat Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Jt Surg Br 86(3):372–377CrossRef Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Jt Surg Br 86(3):372–377CrossRef
6.
Zurück zum Zitat Chin PL, Yang KY, Yeo SJ, Lo NN (2005) Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty 20(5):618–626PubMedCrossRef Chin PL, Yang KY, Yeo SJ, Lo NN (2005) Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty 20(5):618–626PubMedCrossRef
7.
Zurück zum Zitat Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty 20(3):282–288PubMedCrossRef Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty 20(3):282–288PubMedCrossRef
8.
Zurück zum Zitat Fehring TK, Odum S, Griffin WL, Mason JB, Nadaud M (2001) Early failures in total knee arthroplasty. Clin Orthop Relat Res 392:315–318PubMedCrossRef Fehring TK, Odum S, Griffin WL, Mason JB, Nadaud M (2001) Early failures in total knee arthroplasty. Clin Orthop Relat Res 392:315–318PubMedCrossRef
9.
Zurück zum Zitat Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152–159PubMedCrossRef Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152–159PubMedCrossRef
10.
Zurück zum Zitat Hart R, Janecek M, Chaker A, Bucek P (2003) Total knee arthroplasty implanted with and without kinematic navigation. Int Orthop 27(6):366–369PubMedCrossRef Hart R, Janecek M, Chaker A, Bucek P (2003) Total knee arthroplasty implanted with and without kinematic navigation. Int Orthop 27(6):366–369PubMedCrossRef
11.
Zurück zum Zitat Kim SJ, MacDonald M, Hernandez J, Wixson RL (2005) Computer assisted navigation in total knee arthroplasty: improved coronal alignment. J Arthroplasty 20(7 Suppl 3):123–131PubMedCrossRef Kim SJ, MacDonald M, Hernandez J, Wixson RL (2005) Computer assisted navigation in total knee arthroplasty: improved coronal alignment. J Arthroplasty 20(7 Suppl 3):123–131PubMedCrossRef
12.
Zurück zum Zitat Krackow KA, Bayers-Thering M, Phillips MJ, Bayers-Thering M, Mihalko WM (1999) A new technique for determining proper mechanical axis alignment during total knee arthroplasty: progress toward computer-assisted TKA. Orthopedics 22(7):698–702PubMed Krackow KA, Bayers-Thering M, Phillips MJ, Bayers-Thering M, Mihalko WM (1999) A new technique for determining proper mechanical axis alignment during total knee arthroplasty: progress toward computer-assisted TKA. Orthopedics 22(7):698–702PubMed
13.
Zurück zum Zitat Malik MH, Wadia F, Porter ML (2007) Preliminary radiological evaluation of the vector vision CT-free knee module for implantation of the LCS knee prosthesis. Knee 14(1):19–21PubMedCrossRef Malik MH, Wadia F, Porter ML (2007) Preliminary radiological evaluation of the vector vision CT-free knee module for implantation of the LCS knee prosthesis. Knee 14(1):19–21PubMedCrossRef
14.
Zurück zum Zitat Martin A, von Strempel A (2006) Two-year outcomes of computed tomography-based and computed tomography free navigation for total knee arthroplasties. Clin Orthop Relat Res 449:275–282PubMed Martin A, von Strempel A (2006) Two-year outcomes of computed tomography-based and computed tomography free navigation for total knee arthroplasties. Clin Orthop Relat Res 449:275–282PubMed
15.
Zurück zum Zitat Matsumoto T, Tsumura N, Kurosaka M, Muratsu H, Kuroda R, Ishimoto K, Tsujimoto K, Shiba R, Yoshiya S (2004) Prosthetic alignment and sizing in computer-assisted total knee arthroplasty. Int Orthop 28(5):282–285PubMedCrossRef Matsumoto T, Tsumura N, Kurosaka M, Muratsu H, Kuroda R, Ishimoto K, Tsujimoto K, Shiba R, Yoshiya S (2004) Prosthetic alignment and sizing in computer-assisted total knee arthroplasty. Int Orthop 28(5):282–285PubMedCrossRef
16.
Zurück zum Zitat Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Jt Surg Am 89(2):236–243CrossRef Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Jt Surg Am 89(2):236–243CrossRef
17.
Zurück zum Zitat Nofrini L, Slomczykowski M, Iacono F, Marcacci M (2004) Evaluation of accuracy in ankle center location for tibial mechanical axis identification. J Invest Surg 17(1):23–29PubMed Nofrini L, Slomczykowski M, Iacono F, Marcacci M (2004) Evaluation of accuracy in ankle center location for tibial mechanical axis identification. J Invest Surg 17(1):23–29PubMed
18.
Zurück zum Zitat Perlick L, Bathis H, Perlick C, Luring C, Tingart M, Grifka J (2005) Revision total knee arthroplasty: a comparison of postoperative leg alignment after computer-assisted implantation versus the conventional technique. Knee Surg Sports Traumatol Arthrosc 13(3):167–173PubMedCrossRef Perlick L, Bathis H, Perlick C, Luring C, Tingart M, Grifka J (2005) Revision total knee arthroplasty: a comparison of postoperative leg alignment after computer-assisted implantation versus the conventional technique. Knee Surg Sports Traumatol Arthrosc 13(3):167–173PubMedCrossRef
19.
Zurück zum Zitat Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153–156PubMed
20.
Zurück zum Zitat Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Insall award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res 404:7–13PubMedCrossRef Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM (2002) Insall award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res 404:7–13PubMedCrossRef
21.
Zurück zum Zitat Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD (2001) The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA 286(2):188–195PubMedCrossRef Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD (2001) The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA 286(2):188–195PubMedCrossRef
22.
Zurück zum Zitat Siston RA, Daub AC, Giori NJ, Goodman SB, Delp SL (2005) Evaluation of methods that locate the center of the ankle for computer-assisted total knee arthroplasty. Clin Orthop Relat Res 439:129–135PubMedCrossRef Siston RA, Daub AC, Giori NJ, Goodman SB, Delp SL (2005) Evaluation of methods that locate the center of the ankle for computer-assisted total knee arthroplasty. Clin Orthop Relat Res 439:129–135PubMedCrossRef
23.
Zurück zum Zitat Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Jt Surg Br 85(6):830–835 Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Jt Surg Br 85(6):830–835
24.
Zurück zum Zitat Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O (2004) Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 426:180–186PubMedCrossRef Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O (2004) Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 426:180–186PubMedCrossRef
25.
Zurück zum Zitat Subburaj K, Ravi B, Agarwal M (2009) Automated identification of anatomical landmarks on 3D bone models reconstructed from CT scan images. Comput Med Imaging Graph 33(5):359–368PubMedCrossRef Subburaj K, Ravi B, Agarwal M (2009) Automated identification of anatomical landmarks on 3D bone models reconstructed from CT scan images. Comput Med Imaging Graph 33(5):359–368PubMedCrossRef
26.
Zurück zum Zitat van den Bogert AJ, Smith GD, Nigg BM (1994) In vivo determination of the anatomical axes of the ankle joint complex: an optimization approach. J Biomech 27(12):1477–1488PubMedCrossRef van den Bogert AJ, Smith GD, Nigg BM (1994) In vivo determination of the anatomical axes of the ankle joint complex: an optimization approach. J Biomech 27(12):1477–1488PubMedCrossRef
27.
Zurück zum Zitat Victor J, Hoste D (2004) Image-based computer-assisted total knee arthroplasty leads to lower variability in coronal alignment. Clin Orthop Relat Res 428:131–139PubMedCrossRef Victor J, Hoste D (2004) Image-based computer-assisted total knee arthroplasty leads to lower variability in coronal alignment. Clin Orthop Relat Res 428:131–139PubMedCrossRef
Metadaten
Titel
Variations in ankle registration using two different anatomic landmarks: a radiographic study
verfasst von
Eduardo M. Suero
Mustafa Citak
Charles Claps
Andrew D. Pearle
Christopher Plaskos
Publikationsdatum
01.12.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 12/2013
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-012-2165-5

Weitere Artikel der Ausgabe 12/2013

Knee Surgery, Sports Traumatology, Arthroscopy 12/2013 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders scheint das auf weibliche Kranke zuzutreffen, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.