Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 6/2021

07.02.2021 | Handsurgery

Viscoelastic properties of the human A2 finger pulley

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 6/2021

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Biomechanical evaluation of the viscoelastic properties tissue deformation, stiffness, and maximum breaking load of the human A2 pulley. We hypothesized that the A2 pulleys of index, middle, and ring fingers exhibit no difference regarding the aforementioned biomechanical parameters.

Methods

Forty-one A2 pulleys of 14 upper extremities (8 body donors) were assessed. Cyclic and load-to-failure testing were performed. The biomechanical parameters tissue deformation during cyclic and load-to-failure testing, stiffness, and maximum breaking load were determined.

Results

No significant differences between the fingers could be detected regarding the biomechanical parameters. A significant negative correlation could be detected between stiffness and deformation of the pulley. Significant positive correlations could be identified between stiffness and maximum breaking load and between maximum breaking load and deformation of the pulleys.

Conclusions

Assessment of the viscoelastic properties of the A2 finger pulley promotes precise diagnosis of pulley lesions and will help to optimize treatment.
Literatur
3.
Zurück zum Zitat Gabl M, Rangger C, Lutz M, Fink C, Rudisch A, Pechlaner S (1998) Disruption of the finger flexor pulley system in elite rock climbers. Am J Sports Med 26(5):651–655CrossRef Gabl M, Rangger C, Lutz M, Fink C, Rudisch A, Pechlaner S (1998) Disruption of the finger flexor pulley system in elite rock climbers. Am J Sports Med 26(5):651–655CrossRef
5.
Zurück zum Zitat Barton NJ (1969) Experimental study of optimal location of flexor tendon pulleys. PlastReconstrSurg 43(2):125–129 Barton NJ (1969) Experimental study of optimal location of flexor tendon pulleys. PlastReconstrSurg 43(2):125–129
6.
Zurück zum Zitat Lin GT, Amadio PC, An KN, Cooney WP (1989) Functional anatomy of the human digital flexor pulley system. J Hand Surg Am 14(6):949–956CrossRef Lin GT, Amadio PC, An KN, Cooney WP (1989) Functional anatomy of the human digital flexor pulley system. J Hand Surg Am 14(6):949–956CrossRef
9.
Zurück zum Zitat Langer MF, Oeckenpöhler S, Hartensuer R, Herrmann K, Wieskötter B (2015) Pulley reconstruction in the hand. Orthopäde 44(10):757–766CrossRef Langer MF, Oeckenpöhler S, Hartensuer R, Herrmann K, Wieskötter B (2015) Pulley reconstruction in the hand. Orthopäde 44(10):757–766CrossRef
10.
Zurück zum Zitat Doyle JR (1988) Anatomy of the finger flexor tendon sheath and pulley system. J Hand Surg Am 13(4):473–484CrossRef Doyle JR (1988) Anatomy of the finger flexor tendon sheath and pulley system. J Hand Surg Am 13(4):473–484CrossRef
11.
Zurück zum Zitat Doyle JR (1989) Anatomy of the flexor tendon sheath and pulley system: a current review. J Hand Surg Am 14(2 Pt 2):349–351CrossRef Doyle JR (1989) Anatomy of the flexor tendon sheath and pulley system: a current review. J Hand Surg Am 14(2 Pt 2):349–351CrossRef
13.
Zurück zum Zitat Bassemir D, Unglaub F, Hahn P, Müller LP, Bruckner T, Spies CK (2015) Sonographical parameters of the finger pulley system in helathy adults. Arch Orthop Trauma Surg 135(11):1615–1622CrossRef Bassemir D, Unglaub F, Hahn P, Müller LP, Bruckner T, Spies CK (2015) Sonographical parameters of the finger pulley system in helathy adults. Arch Orthop Trauma Surg 135(11):1615–1622CrossRef
14.
Zurück zum Zitat Lin GT, Cooney P, Amadio PC, An KN (1990) Mechanical properties of human pulleys. J Hand SurgEur 15B(4):429–434CrossRef Lin GT, Cooney P, Amadio PC, An KN (1990) Mechanical properties of human pulleys. J Hand SurgEur 15B(4):429–434CrossRef
15.
Zurück zum Zitat Marco RA, Sharkey NA, Smith TS, Zissimos AG (1998) Pathomechanics of closed rupture of the flexor tendon pulleys in rock climbers. J Bone Joint Surg Am 80(7):1012–1019CrossRef Marco RA, Sharkey NA, Smith TS, Zissimos AG (1998) Pathomechanics of closed rupture of the flexor tendon pulleys in rock climbers. J Bone Joint Surg Am 80(7):1012–1019CrossRef
16.
Zurück zum Zitat Schöffl V, Hochholzer T, Winkelmann HP, Strecker W (2003) Pulley injuries in rock climbers. Wilderness Environ Med 14(2):94–100CrossRef Schöffl V, Hochholzer T, Winkelmann HP, Strecker W (2003) Pulley injuries in rock climbers. Wilderness Environ Med 14(2):94–100CrossRef
17.
Zurück zum Zitat Hohendorff B, Unglaub F, Spies CK, Wegmann K, Müller LP, Ries C (2019) Surgical approaches to the hand. OperOrthopTraumatol 31(5):372–383 Hohendorff B, Unglaub F, Spies CK, Wegmann K, Müller LP, Ries C (2019) Surgical approaches to the hand. OperOrthopTraumatol 31(5):372–383
18.
Zurück zum Zitat Armitage P, Berry G, Matthews JNS (2002) Statistical methods in medical research, 4th edn. Blackwell Scientific Ltd, OxfordCrossRef Armitage P, Berry G, Matthews JNS (2002) Statistical methods in medical research, 4th edn. Blackwell Scientific Ltd, OxfordCrossRef
19.
Zurück zum Zitat Martinoli C, Bianchi S, Nebiolo M, Derchi LE, Garcia JF (2000) Sonographic evaluation of digital annular pulley tears. Skeletal Radiol 29(7):387–391CrossRef Martinoli C, Bianchi S, Nebiolo M, Derchi LE, Garcia JF (2000) Sonographic evaluation of digital annular pulley tears. Skeletal Radiol 29(7):387–391CrossRef
21.
Zurück zum Zitat Stauffer A, Schwarz Y, Uranyi M, Schachinger F, Girsch W, Ganger R, Farr S (2020) Outcomes after thumb carpometacarpal joint stabilization with an abductor pollicis longus tendon strip for the treatment of chronic instability. Arch Orthop Trauma Surg 140(2):275–282CrossRef Stauffer A, Schwarz Y, Uranyi M, Schachinger F, Girsch W, Ganger R, Farr S (2020) Outcomes after thumb carpometacarpal joint stabilization with an abductor pollicis longus tendon strip for the treatment of chronic instability. Arch Orthop Trauma Surg 140(2):275–282CrossRef
22.
Zurück zum Zitat Klauser A, Bodner G, Frauscher F, Gabl M, ZurNedden D (1999) Finger injuries in extreme rock climbers Assessment of high-resolution ultrasonography. Am J Sports Med 27(6):733–737CrossRef Klauser A, Bodner G, Frauscher F, Gabl M, ZurNedden D (1999) Finger injuries in extreme rock climbers Assessment of high-resolution ultrasonography. Am J Sports Med 27(6):733–737CrossRef
23.
Zurück zum Zitat Uludag A, Tosun HB, Celik S, Serbest S, Kayalar M, Aytac G, Sindel M, ErbayElibol FK, Demir T (2020) Comparison of various tendon repair techniques in extensor zone 3 injuries: an experimental biomechanical cadaver study. Arch Orthop Trauma Surg 140(4):583–590CrossRef Uludag A, Tosun HB, Celik S, Serbest S, Kayalar M, Aytac G, Sindel M, ErbayElibol FK, Demir T (2020) Comparison of various tendon repair techniques in extensor zone 3 injuries: an experimental biomechanical cadaver study. Arch Orthop Trauma Surg 140(4):583–590CrossRef
25.
Zurück zum Zitat Pillukat T, Kalb K, Fuhrmann R, Windolf J, van Schoonhoven J (2019) Reconstruction of the middle phalangeal base of the finger using an osteocartilaginous autograft from the hamate. OperOrthop Trauma 31(5):393–407CrossRef Pillukat T, Kalb K, Fuhrmann R, Windolf J, van Schoonhoven J (2019) Reconstruction of the middle phalangeal base of the finger using an osteocartilaginous autograft from the hamate. OperOrthop Trauma 31(5):393–407CrossRef
26.
Zurück zum Zitat Langer MF, Wieskötter B, Öckenpöhler S, Unglaub F, Spies C, Grünert JG (2020) Secondary reconstruction of flexor tendons. Unfallchirurg 123(2):114–125CrossRef Langer MF, Wieskötter B, Öckenpöhler S, Unglaub F, Spies C, Grünert JG (2020) Secondary reconstruction of flexor tendons. Unfallchirurg 123(2):114–125CrossRef
Metadaten
Titel
Viscoelastic properties of the human A2 finger pulley
Publikationsdatum
07.02.2021
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 6/2021
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-021-03781-8

Weitere Artikel der Ausgabe 6/2021

Archives of Orthopaedic and Trauma Surgery 6/2021 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.