Sonographical parameters of the finger pulley system in healthy adults
verfasst von:
Dominik Bassemir, Frank Unglaub, Peter Hahn, Lars Peter Müller, Thomas Bruckner, Christian K. Spies
Erschienen in:
Archives of Orthopaedic and Trauma Surgery
|
Ausgabe 11/2015
Einloggen, um Zugang zu erhalten
Abstract
Introduction
To establish normative values of tendon to bone distances (TBDs) to evaluate the A2 and A4 annular pulley integrity, we hypothesized that these values correlate with gender, athletic exercise, occupation, individual’s age and body height.
Methods
Ultrasonography of 200 healthy individuals was performed prospectively. TBDs for the A2 and A4 pulley sections were measured for all fingers. Evaluation was performed in resting position and active forced flexion. Examination parameters included gender, age, body height, occupation, athletic exercise level, and hand dominance. Assessment of resting position and active forced flexion was done.
Results
No clinically relevant differences of TBDs with respect to the aforementioned parameters were observed. But TBDs were significantly greater in active forced flexion than in resting position for all measured pulley sections. Intraobserver reliability was very satisfactory.
Conclusions
Establishing normative values will help to detect injured pulleys more precisely and examination should be performed both in resting position and active forced flexion.