Skip to main content
main-content

01.03.2014 | Cardiac | Ausgabe 3/2014

European Radiology 3/2014

320-row CT coronary angiography predicts freedom from revascularisation and acts as a gatekeeper to defer invasive angiography in stable coronary artery disease: a fractional flow reserve-correlated study

Zeitschrift:
European Radiology > Ausgabe 3/2014
Autoren:
Brian S. Ko, Dennis T. L. Wong, James D. Cameron, Darryl P. Leong, Michael Leung, Ian T. Meredith, Nitesh Nerlekar, Paul Antonis, Marcus Crossett, John Troupis, Richard Harper, Yuvaraj Malaiapan, Sujith K. Seneviratne

Abstract

Objectives

To determine the accuracy of 320-row multidetector coronary computed tomography angiography (M320-CCTA) to detect functional stenoses using fractional flow reserve (FFR) as the reference standard and to predict revascularisation in stable coronary artery disease.

Methods

One hundred and fifteen patients (230 vessels) underwent M320-CCTA and FFR assessment and were followed for 18 months. Diameter stenosis on invasive angiography (ICA) and M320-CCTA were assessed by consensus by two observers and significant stenosis was defined as ≥50 %. FFR ≤0.8 indicated functionally significant stenoses.

Results

M320-CCTA had 94 % sensitivity and 94 % negative predictive value (NPV) for FFR ≤0.8. Overall accuracy was 70 %, specificity 54 % and positive predictive value 65 %. On receiver operating characteristic (ROC) curve analysis, the area under the curve (AUC) for CCTA to predict FFR ≤0.8 was 0.74 which was comparable with ICA. The absence of a significant stenosis on M320-CCTA was associated with a 6 % revascularisation rate. M320-CCTA predicted revascularisation with an AUC of 0.71 which was comparable with ICA.

Conclusions

M320-CCTA has excellent sensitivity and NPV for functional stenoses and therefore may act as an effective gatekeeper to defer ICA and revascularisation. Like ICA, M320-CCTA lacks specificity for functional stenoses and only has moderate accuracy to predict the need for revascularisation.

Key Points

Important information about the heart is provided by 320-row multidetector CT coronary angiography (M320-CCTA).
M320-CCTA accurately detects and excludes functional stenoses determined by fractional flow reserve (FFR).
Non-significant stenoses on M320-CCTA associated with fewer cardiac events and less revascularisation.
M320-CCTA may act as a gatekeeper for invasive angiography and inappropriate revascularisation.
Like ICA, M320-CCTA only has moderate accuracy to predict vessels requiring revascularisation.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 3/2014

European Radiology 3/2014 Zur Ausgabe
  1. Sie können e.Med Radiologie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

Neu im Fachgebiet Radiologie

Meistgelesene Bücher aus der Radiologie

2016 | Buch

Medizinische Fremdkörper in der Bildgebung

Thorax, Abdomen, Gefäße und Kinder

Dieses einzigartige Buch enthält ca. 1.600 hochwertige radiologische Abbildungen und Fotos iatrogen eingebrachter Fremdmaterialien im Röntgenbild und CT.

Herausgeber:
Dr. med. Daniela Kildal

2011 | Buch

Atlas Klinische Neuroradiologie des Gehirns

Radiologie lebt von Bildern! Der vorliegende Atlas trägt dieser Tatsache Rechnung. Sie finden zu jedem Krankheitsbild des Gehirns Referenzbilder zum Abgleichen mit eigenen Befunden.

Autoren:
Priv.-Doz. Dr. med. Jennifer Linn, Prof. Dr. med. Martin Wiesmann, Prof. Dr. med. Hartmut Brückmann

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Radiologie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise