Background

A hands-free region-of-interest (ROI) selection interface is proposed for solo surgery using a wide-angle endoscope. A wide-angle endoscope provides images with a larger field of view than a conventional endoscope. With an appropriate selection interface for a ROI, surgeons can also obtain a detailed local view as if they moved a conventional endoscope in a specific position and direction.

Methods

To manipulate the endoscope without releasing the surgical instrument in hand, a mini-camera is attached to the instrument, and the images taken by the attached camera are analyzed. When a surgeon moves the instrument, the instrument orientation is calculated by an image processing. Surgeons can select the ROI with this instrument movement after switching from ‘task mode’ to ‘selection mode.’ The accelerated KAZE algorithm is used to track the features of the camera images once the instrument is moved. Both the wide-angle and detailed local views are displayed simultaneously, and a surgeon can move the local view area by moving the mini-camera attached to the surgical instrument.

Results

Local view selection for a solo surgery was performed without releasing the instrument. The accuracy of camera pose estimation was not significantly different between camera resolutions, but it was significantly different between background camera images with different numbers of features (P < 0.01). The success rate of ROI selection diminished as the number of separated regions increased. However, separated regions up to 12 with a region size of 160 × 160 pixels were selected with no failure. Surgical tasks on a phantom model and a cadaver were attempted to verify the feasibility in a clinical environment.

Conclusions

Hands-free endoscope manipulation without releasing the instruments in hand was achieved. The proposed method requires only a small, low-cost camera and an image processing. The technique enables surgeons to perform solo surgeries without a camera assistant.
Literatur
1.
Zurück zum Zitat Rahman MN, Mishra R (2011) The camera-holding robotic device in laparoscopy surgery. World J Laparosc Surg 4:132–135CrossRef Rahman MN, Mishra R (2011) The camera-holding robotic device in laparoscopy surgery. World J Laparosc Surg 4:132–135CrossRef
2.
3.
Zurück zum Zitat Gilbert J (2009) The EndoAssist™ robotic camera holder as an aid to the introduction of laparoscopic colorectal surgery. Ann R Coll Surg Engl 91:389–393CrossRefPubMedPubMedCentral Gilbert J (2009) The EndoAssist™ robotic camera holder as an aid to the introduction of laparoscopic colorectal surgery. Ann R Coll Surg Engl 91:389–393CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Buess G, Arezzo A, Schurr M, Ulmer F, Fisher H, Gumb L, Testa T, Nobman C (2000) A new remote-controlled endoscope positioning system for endoscopic solo surgery. Surg Endosc 14:395–399CrossRefPubMed Buess G, Arezzo A, Schurr M, Ulmer F, Fisher H, Gumb L, Testa T, Nobman C (2000) A new remote-controlled endoscope positioning system for endoscopic solo surgery. Surg Endosc 14:395–399CrossRefPubMed
5.
Zurück zum Zitat Yasunaga T, Hashizume M, Kobayashi E, Tanoue K, Akahoshi T, Konishi K, Yamaguchi S, Kinjo N, Tomikawa M, Muragaki Y (2003) Remote-controlled laparoscope manipulator system, Naviot™, for endoscopic surgery. International Congress series. Elsevier, Amsterdam, pp 678–683 Yasunaga T, Hashizume M, Kobayashi E, Tanoue K, Akahoshi T, Konishi K, Yamaguchi S, Kinjo N, Tomikawa M, Muragaki Y (2003) Remote-controlled laparoscope manipulator system, Naviot™, for endoscopic surgery. International Congress series. Elsevier, Amsterdam, pp 678–683
6.
Zurück zum Zitat Kobayashi E, Masamune K, Sakuma I, Dohi T (2000) A wide-angle view endoscope system using wedge prisms. In: Medical image computing and computer-assisted intervention—MICCAI 2000, Springer, pp 661–668 Kobayashi E, Masamune K, Sakuma I, Dohi T (2000) A wide-angle view endoscope system using wedge prisms. In: Medical image computing and computer-assisted intervention—MICCAI 2000, Springer, pp 661–668
7.
Zurück zum Zitat Tamadazte B, Agustinos A, Cinquin P, Fiard G, Voros S (2015) Multi-view vision system for laparoscopy surgery. Int J Comput Assist Radiol Surg 10:195–203CrossRefPubMed Tamadazte B, Agustinos A, Cinquin P, Fiard G, Voros S (2015) Multi-view vision system for laparoscopy surgery. Int J Comput Assist Radiol Surg 10:195–203CrossRefPubMed
8.
Zurück zum Zitat Cao A, Darin Ellis R, Composto A, Pandya AK, Klein MD (2006) Supplemental wide field-of-view monitor improves performance in surgical telerobotic movement time. Int J Med Robot Comput Assist Surg 2:364–369CrossRef Cao A, Darin Ellis R, Composto A, Pandya AK, Klein MD (2006) Supplemental wide field-of-view monitor improves performance in surgical telerobotic movement time. Int J Med Robot Comput Assist Surg 2:364–369CrossRef
9.
Zurück zum Zitat Jung K, Kang D-J, Kekatpure AL, Adikrishna A, Hong J, Jeon I-H (2016) A new wide-angle arthroscopic system: a comparative study with a conventional 30° arthroscopic system. Knee Surg Sports Traumatol Arthrosc 24:1722–1729CrossRefPubMed Jung K, Kang D-J, Kekatpure AL, Adikrishna A, Hong J, Jeon I-H (2016) A new wide-angle arthroscopic system: a comparative study with a conventional 30° arthroscopic system. Knee Surg Sports Traumatol Arthrosc 24:1722–1729CrossRefPubMed
10.
Zurück zum Zitat Sekiya T, Ito E, Kanai M, Matsumoto M (2006) Development of a dual-view endoscope system. In: Biomedical optics 2006, International Society for Optics and Photonics, pp 60800E-1–60800E-10 Sekiya T, Ito E, Kanai M, Matsumoto M (2006) Development of a dual-view endoscope system. In: Biomedical optics 2006, International Society for Optics and Photonics, pp 60800E-1–60800E-10
11.
Zurück zum Zitat Tsunezuka H, Kato D, Terauchi K, Shimomura M, Ichise K, Ito K, Nishikawa A, Shimada J (2011) Analysis of surgeon’s line of sight using an optical tracking system with a multifaceted marker device. Int J Comput Assist Radiol Surg 6:803–809CrossRefPubMed Tsunezuka H, Kato D, Terauchi K, Shimomura M, Ichise K, Ito K, Nishikawa A, Shimada J (2011) Analysis of surgeon’s line of sight using an optical tracking system with a multifaceted marker device. Int J Comput Assist Radiol Surg 6:803–809CrossRefPubMed
12.
Zurück zum Zitat Singh H, Karar V, Kumar N, Saini SS (2013) Performance comparison: optical and magnetic head tracking. Int J IT Eng Appl Sci Res 2:27–32 Singh H, Karar V, Kumar N, Saini SS (2013) Performance comparison: optical and magnetic head tracking. Int J IT Eng Appl Sci Res 2:27–32
13.
Zurück zum Zitat Alcantarilla PF, Solutions T (2011) Fast explicit diffusion for accelerated features in nonlinear scale spaces. IEEE Trans Pattern Anal Mach Intell 34:1281–1298 Alcantarilla PF, Solutions T (2011) Fast explicit diffusion for accelerated features in nonlinear scale spaces. IEEE Trans Pattern Anal Mach Intell 34:1281–1298
14.
Zurück zum Zitat Alcantarilla PF, Bartoli A, Davison AJ (2012) KAZE features. In: Computer vision—ECCV 2012, Springer, pp 214–227 Alcantarilla PF, Bartoli A, Davison AJ (2012) KAZE features. In: Computer vision—ECCV 2012, Springer, pp 214–227
15.
Zurück zum Zitat Lowe DG (2004) Distinctive image features from scale-invariant keypoints. Int J Comput Vis 60:91–110CrossRef Lowe DG (2004) Distinctive image features from scale-invariant keypoints. Int J Comput Vis 60:91–110CrossRef
16.
Zurück zum Zitat Luong Q-T, Faugeras OD (1996) The fundamental matrix: theory, algorithms, and stability analysis. Int J Comput Vis 17:43–75CrossRef Luong Q-T, Faugeras OD (1996) The fundamental matrix: theory, algorithms, and stability analysis. Int J Comput Vis 17:43–75CrossRef
17.
Zurück zum Zitat Perrin M, Fletcher A (2004) Laparoscopic abdominal surgery. Contin Educ Anaesth Crit Care Pain 4:107–110CrossRef Perrin M, Fletcher A (2004) Laparoscopic abdominal surgery. Contin Educ Anaesth Crit Care Pain 4:107–110CrossRef
18.
Zurück zum Zitat Tan W, Liu H, Dong Z, Zhang G, Bao H (2013) Robust monocular SLAM in dynamic environments. In: Mixed and augmented reality (ISMAR), 2013 IEEE international symposium on, IEEE, pp 209–218 Tan W, Liu H, Dong Z, Zhang G, Bao H (2013) Robust monocular SLAM in dynamic environments. In: Mixed and augmented reality (ISMAR), 2013 IEEE international symposium on, IEEE, pp 209–218
Metadaten
Titel
A hands-free region-of-interest selection interface for solo surgery with a wide-angle endoscope: preclinical proof of concept
verfasst von
Kyunghwa Jung
Hyunseok Choi
Hanpyo Hong
Arnold Adikrishna
In-Ho Jeon
Jaesung Hong
Publikationsdatum
08.08.2016
Verlag
Springer US
Erschienen in
Surgical Endoscopy / Ausgabe 2/2017
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-016-5013-8

Weitere Artikel der Ausgabe 2/2017

Surgical Endoscopy 2/2017 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.