Skip to main content
Erschienen in: Surgical Endoscopy 11/2017

07.04.2017

A multicentric prospective study evaluating the safety and efficacy of Kii® Fios® First Entry Trocar in laparoscopic bariatric surgery

verfasst von: Marcelo Loureiro, Mohamad Ramadan, El Mehdi Skalli, Pierre Blanc, Jean Michel Fabre, David Nocca

Erschienen in: Surgical Endoscopy | Ausgabe 11/2017

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Laparoscopic surgery has evolved as an important field of surgery due to its clear benefits when compared to open laparotomy surgery. However, specific complications of laparoscopic surgery have been reported, of which the majority are complications associated with first entry to the abdominal cavity. The emergence of bariatric surgery, combined with the special considerations of the abdominal wall and cavity of obese patients, leads to seeking new modalities of access to the abdominal cavity in this specific population.Kii Fios First Entry Bladeless Trocar (Applied) is a new device that may allow surgeons to facilitate the creation of pneumoperitoneum. This prospective multicenter nonrandomized trial aims to evaluate the safety and efficacy of Kii Fios First Entry Bladeless Trocar in laparoscopic bariatric surgery.

Methods

In the period between December 2013 and June 2014, 588 patients were included by 18 surgeons from several French hospitals to undergo laparoscopic surgery using Kii Fios First Entry Trocar as a first-entry trocar. The surgeons filled out a questionnaire assessing the safety and efficacy of the trocar for every patient.

Results

There were no mortality and no major complications. However, 11 cases (1.87%) of minor complications (liver and greater omentum injuries) were reported. The surgeons reported successful entry in less than 1 min for 70.58% of the cases.

Conclusions

Kii Fios First Entry Trocar (Applied) is a safe and efficient method to establish first entry in laparoscopic bariatric surgery when all the recommendations are followed and respected.
Literatur
1.
Zurück zum Zitat Jansen FW, Kapiteyn K, Trimbos-Kemper T, Hermans J, Trimbos JB (1997) Complications of laparoscopy: a prospective multicentre observational study. Br J Obstet Gynaecol 104:595–600CrossRefPubMed Jansen FW, Kapiteyn K, Trimbos-Kemper T, Hermans J, Trimbos JB (1997) Complications of laparoscopy: a prospective multicentre observational study. Br J Obstet Gynaecol 104:595–600CrossRefPubMed
2.
Zurück zum Zitat Harkki-Siren P, Kurki T (1997) A nationwide analysis of laparoscopic complications. Obstet Gynecol 89:108–112CrossRefPubMed Harkki-Siren P, Kurki T (1997) A nationwide analysis of laparoscopic complications. Obstet Gynecol 89:108–112CrossRefPubMed
3.
Zurück zum Zitat Chapron CM, Pierre F, Lacroix S, Querleu D, Lansac J, Dubuisson JB (1997) Major vascular injuries during gynecologic laparoscopy. J Am Coll Surg 185:461–465CrossRefPubMed Chapron CM, Pierre F, Lacroix S, Querleu D, Lansac J, Dubuisson JB (1997) Major vascular injuries during gynecologic laparoscopy. J Am Coll Surg 185:461–465CrossRefPubMed
4.
Zurück zum Zitat Nuzzo G, Giuliante F, Tebala GD (1997) Routine use of open technique in laparoscopic operations. J Am Coll Surg 184:58–62PubMed Nuzzo G, Giuliante F, Tebala GD (1997) Routine use of open technique in laparoscopic operations. J Am Coll Surg 184:58–62PubMed
5.
6.
Zurück zum Zitat Jansen FW, Kolkman W, Bakkum EA, de Kroon CD, Trimbos-Kemper TCM, Trimbos JB (2004) Complications of laparoscopy: an inquiry about closed versus open-entry technique. Am J Obstet Gynecol 190:634–638CrossRefPubMed Jansen FW, Kolkman W, Bakkum EA, de Kroon CD, Trimbos-Kemper TCM, Trimbos JB (2004) Complications of laparoscopy: an inquiry about closed versus open-entry technique. Am J Obstet Gynecol 190:634–638CrossRefPubMed
7.
Zurück zum Zitat Fuller J, Scott W, Ashar B, Corrado J (2005) Laparoscopic trocar injuries: a report from a U.S. Food and Drug Administration (FDA) Center for Devices and Radiological Health (CDRH) Systematic Technology Assessment of Medical Products (STAMP) Committee. 8/25/2005, pp 1–14 Fuller J, Scott W, Ashar B, Corrado J (2005) Laparoscopic trocar injuries: a report from a U.S. Food and Drug Administration (FDA) Center for Devices and Radiological Health (CDRH) Systematic Technology Assessment of Medical Products (STAMP) Committee. 8/25/2005, pp 1–14
8.
9.
Zurück zum Zitat Dingfelder JR (1978) Direct laparoscopic trocar insertion without prior pneumoperitoneum. J Reprod Med 21:45–47PubMed Dingfelder JR (1978) Direct laparoscopic trocar insertion without prior pneumoperitoneum. J Reprod Med 21:45–47PubMed
10.
Zurück zum Zitat Hasson HM (1971) A modified instrument and method for laparoscopy. Am J Obstet Gynecol 110:886–887CrossRefPubMed Hasson HM (1971) A modified instrument and method for laparoscopy. Am J Obstet Gynecol 110:886–887CrossRefPubMed
11.
12.
Zurück zum Zitat Mettler L, Schmidt EH, Frank V, Semm K (1999) Optical trocar systems: laparoscopic entry and its complications (a study of case in Germany). Gynaecol Endosc 8:383–389CrossRef Mettler L, Schmidt EH, Frank V, Semm K (1999) Optical trocar systems: laparoscopic entry and its complications (a study of case in Germany). Gynaecol Endosc 8:383–389CrossRef
13.
Zurück zum Zitat Wolfart W (1990) Surgical treatment of tuberculosis and its modifications—collapse therapy and resection treatment and their present-day sequelae. Offentl Gesundh 52(8–9):506–511 Wolfart W (1990) Surgical treatment of tuberculosis and its modifications—collapse therapy and resection treatment and their present-day sequelae. Offentl Gesundh 52(8–9):506–511
14.
Zurück zum Zitat Veres J (1938) Neues instrument zur ausfuhrung von brust-oder bauchpunktionen und pneumothoraxbehandlung. Deut Med Wochenschr 64:1480–1481CrossRef Veres J (1938) Neues instrument zur ausfuhrung von brust-oder bauchpunktionen und pneumothoraxbehandlung. Deut Med Wochenschr 64:1480–1481CrossRef
15.
Zurück zum Zitat Molloy D, Kaloo PD, Cooper M et al (2002) Laparoscopic entry: a literature review and analysis of techniques and complications of primary port entry. Aust N Z J Obstet Gynaecol 42:246–253CrossRefPubMed Molloy D, Kaloo PD, Cooper M et al (2002) Laparoscopic entry: a literature review and analysis of techniques and complications of primary port entry. Aust N Z J Obstet Gynaecol 42:246–253CrossRefPubMed
16.
Zurück zum Zitat Catarci M, Carlini M, Gentileschi P, Santoro E, for the Lap Group Roma (2001) Major and minor injuries during the creation of pneumoperitoneum: a multicenter study on 12,919 cases. Surg Endosc 15:566–569CrossRefPubMed Catarci M, Carlini M, Gentileschi P, Santoro E, for the Lap Group Roma (2001) Major and minor injuries during the creation of pneumoperitoneum: a multicenter study on 12,919 cases. Surg Endosc 15:566–569CrossRefPubMed
17.
Zurück zum Zitat Byron JW, Markenson G, Miyazawa K (1993) A randomized comparison of Veress needle and direct trocar insertion for laparoscopy. Surg Gynecol Obstet 177:259–262PubMed Byron JW, Markenson G, Miyazawa K (1993) A randomized comparison of Veress needle and direct trocar insertion for laparoscopy. Surg Gynecol Obstet 177:259–262PubMed
18.
Zurück zum Zitat Borgatta L, Gruss L, Barad D, Kaali SG (1990) Direct trocar insertion vs Veress needle use for laparoscopic sterilization. J Reprod Med 35:891–894PubMed Borgatta L, Gruss L, Barad D, Kaali SG (1990) Direct trocar insertion vs Veress needle use for laparoscopic sterilization. J Reprod Med 35:891–894PubMed
19.
Zurück zum Zitat Cornette B, Berrevoet F (2016) Trocar Injuries in laparoscopy: techniques, tools and means for prevention. A systematic review of the literature. World J Surg Pub 40(10):2331–2441CrossRef Cornette B, Berrevoet F (2016) Trocar Injuries in laparoscopy: techniques, tools and means for prevention. A systematic review of the literature. World J Surg Pub 40(10):2331–2441CrossRef
20.
Zurück zum Zitat Sigman HH, Fried GM, Garzon J, Hinchey EJ, Wexler MJ, Meakins JL (1993) Risks of blind versus open approach to celiotomy for laparoscopic surgery. Surg Laparosc Endosc 3:296–299PubMed Sigman HH, Fried GM, Garzon J, Hinchey EJ, Wexler MJ, Meakins JL (1993) Risks of blind versus open approach to celiotomy for laparoscopic surgery. Surg Laparosc Endosc 3:296–299PubMed
21.
Zurück zum Zitat Bonjer HJ, Hazebroek EJ, Kazemier G, Giuffrida MC, Meijer WS, Lange JF (1997) Open versus closed establishment of pneumoperitoneum in laparoscopic surgery. Br J Surg 84:599–602CrossRefPubMed Bonjer HJ, Hazebroek EJ, Kazemier G, Giuffrida MC, Meijer WS, Lange JF (1997) Open versus closed establishment of pneumoperitoneum in laparoscopic surgery. Br J Surg 84:599–602CrossRefPubMed
22.
Zurück zum Zitat Zaraca F, Catarci M, Gosselti F, Mulieri G, Carboni M (1999) Routine use of open laparoscopy: 1006 consecutive cases. J Laparoendosc Adv Surg Tech A 9:75–80CrossRefPubMed Zaraca F, Catarci M, Gosselti F, Mulieri G, Carboni M (1999) Routine use of open laparoscopy: 1006 consecutive cases. J Laparoendosc Adv Surg Tech A 9:75–80CrossRefPubMed
23.
Zurück zum Zitat Schafer M, Lauper M, Krahenbuhl L (2001) Trocar and Veress needle injuries during laparoscopy. Surg Endosc 15:275–280CrossRefPubMed Schafer M, Lauper M, Krahenbuhl L (2001) Trocar and Veress needle injuries during laparoscopy. Surg Endosc 15:275–280CrossRefPubMed
24.
Zurück zum Zitat Molloy D, Kalloo PD, Cooper M, Nguyen TV (2002) Laparoscopic entry: a literature review and analysis of techniques and complications of primary port entry. Aust NZJ Obstet Gynaecol 42:246–254CrossRef Molloy D, Kalloo PD, Cooper M, Nguyen TV (2002) Laparoscopic entry: a literature review and analysis of techniques and complications of primary port entry. Aust NZJ Obstet Gynaecol 42:246–254CrossRef
25.
Zurück zum Zitat Rabl C, Palazzo F, Aoki H et al (2008) Initial laparoscopic access using an optical trocar without pneumoperitoneum is safe and effective in the morbidly obese. Surg Innov 15:126–131CrossRefPubMed Rabl C, Palazzo F, Aoki H et al (2008) Initial laparoscopic access using an optical trocar without pneumoperitoneum is safe and effective in the morbidly obese. Surg Innov 15:126–131CrossRefPubMed
26.
Zurück zum Zitat String A, Berber E, Foroutani A et al (2001) Use of the optical access trocar for safe and rapid entry in various laparoscopic procedures. Surg Endosc 15:570–573CrossRefPubMed String A, Berber E, Foroutani A et al (2001) Use of the optical access trocar for safe and rapid entry in various laparoscopic procedures. Surg Endosc 15:570–573CrossRefPubMed
27.
Zurück zum Zitat Tinelli A, Malvasi A, Istre O et al (2010) Abdominal access in gynaecological laparoscopy: a comparison between direct optical and blind closed access by Verres needle. Eur J Obstet Gynecol Reprod Biol 148:191–194CrossRefPubMed Tinelli A, Malvasi A, Istre O et al (2010) Abdominal access in gynaecological laparoscopy: a comparison between direct optical and blind closed access by Verres needle. Eur J Obstet Gynecol Reprod Biol 148:191–194CrossRefPubMed
28.
Zurück zum Zitat Portillo-Sanchez P, Bril F, Maximos M, Lomonaco R, Biernacki D, Orsak B, Subbarayan S, Webb A, Hecht J, Cusi K (2015) High prevalence of nonalcoholic fatty liver disease in patients with type 2 diabetes mellitus and normal plasma aminotransferase levels. J Clin Endocrinol Metab 100(6):2231–2238CrossRefPubMed Portillo-Sanchez P, Bril F, Maximos M, Lomonaco R, Biernacki D, Orsak B, Subbarayan S, Webb A, Hecht J, Cusi K (2015) High prevalence of nonalcoholic fatty liver disease in patients with type 2 diabetes mellitus and normal plasma aminotransferase levels. J Clin Endocrinol Metab 100(6):2231–2238CrossRefPubMed
30.
Zurück zum Zitat Yamazaki H, Tsuboya T, Tsuji K, Dohke M, Maguchi H (2015) Independent association between improvement of nonalcoholic fatty liver disease and reduced incidence of type 2 diabetes mellitus. Diabetes Care 38(9):1673–1679CrossRefPubMed Yamazaki H, Tsuboya T, Tsuji K, Dohke M, Maguchi H (2015) Independent association between improvement of nonalcoholic fatty liver disease and reduced incidence of type 2 diabetes mellitus. Diabetes Care 38(9):1673–1679CrossRefPubMed
31.
Zurück zum Zitat Lau B, Kim H, Haigh PI, Tejirian T (2012) Obesity increases the odds of acquiring and incarcerating noninguinal abdominal wall hernias. Am Surg 78(10):1118–1121PubMed Lau B, Kim H, Haigh PI, Tejirian T (2012) Obesity increases the odds of acquiring and incarcerating noninguinal abdominal wall hernias. Am Surg 78(10):1118–1121PubMed
32.
Zurück zum Zitat Kassir R, Blanc P, Lointier P, Tiffet O, Berger JL, Amor IB, Gugenheim J (2014) Laparoscopic entry techniques in obese patient: Verres needle, direct trocar insertion or open entry technique? Obes Surg 24(12):2193–2194CrossRefPubMed Kassir R, Blanc P, Lointier P, Tiffet O, Berger JL, Amor IB, Gugenheim J (2014) Laparoscopic entry techniques in obese patient: Verres needle, direct trocar insertion or open entry technique? Obes Surg 24(12):2193–2194CrossRefPubMed
33.
Zurück zum Zitat Mayol J, Garcia-Aguilar J, Ortiz-Oshiro E, De-Diego JA, Carmona JA, Fernandez-Represa JA (1997) Risks of the minimal access approach for laparoscopic surgery: multivariate analysis of morbidity related to umbilical trocar insertion. World J Surg 21(5):529–533CrossRefPubMed Mayol J, Garcia-Aguilar J, Ortiz-Oshiro E, De-Diego JA, Carmona JA, Fernandez-Represa JA (1997) Risks of the minimal access approach for laparoscopic surgery: multivariate analysis of morbidity related to umbilical trocar insertion. World J Surg 21(5):529–533CrossRefPubMed
34.
Zurück zum Zitat Mirhashemi R, Harlow BL, Ginsburg ES, Signorello LB, Berkowitz R, Feldman S (1998) Predicting risk of complications with gynecologic laparoscopic surgery. Obstet Gynecol 92(3):327–331PubMed Mirhashemi R, Harlow BL, Ginsburg ES, Signorello LB, Berkowitz R, Feldman S (1998) Predicting risk of complications with gynecologic laparoscopic surgery. Obstet Gynecol 92(3):327–331PubMed
35.
Zurück zum Zitat Corson SL, Batzer FR, Gocial B, Maislin G (1994) Measurement of the force necessary for laparoscopic trocar entry. J Reprod Med 34(4):282–284 Corson SL, Batzer FR, Gocial B, Maislin G (1994) Measurement of the force necessary for laparoscopic trocar entry. J Reprod Med 34(4):282–284
36.
Zurück zum Zitat Tarnay CM, Glass K, Munro MG (1999) Entry force and intra-abdominal pressure associated with six laparoscopic trocar cannula systems: a randomized comparison. Obstet Gynecol 94(1):83–88PubMed Tarnay CM, Glass K, Munro MG (1999) Entry force and intra-abdominal pressure associated with six laparoscopic trocar cannula systems: a randomized comparison. Obstet Gynecol 94(1):83–88PubMed
37.
Zurück zum Zitat Ertugrul I, Kayaalp C, Yagci MA, Sumer F, Karagul S, Tolan K (2015) Comparison of direct trocar entry and Veress needle entry in laparoscopic bariatric surgery: randomized controlled trial. J Laparoendosc Adv Surg Tech A. 25(11):875–879. doi:10.1089/lap.2015.0317 Epub 2015 Sep 23 CrossRefPubMed Ertugrul I, Kayaalp C, Yagci MA, Sumer F, Karagul S, Tolan K (2015) Comparison of direct trocar entry and Veress needle entry in laparoscopic bariatric surgery: randomized controlled trial. J Laparoendosc Adv Surg Tech A. 25(11):875–879. doi:10.​1089/​lap.​2015.​0317 Epub 2015 Sep 23 CrossRefPubMed
38.
Zurück zum Zitat Hill DJ, Maher PJ (1996) Direct cannula entry for laparoscopy. J Am Assoc Gynecol Laparosc 4(1):77–79CrossRefPubMed Hill DJ, Maher PJ (1996) Direct cannula entry for laparoscopy. J Am Assoc Gynecol Laparosc 4(1):77–79CrossRefPubMed
39.
Zurück zum Zitat Audebert AJ, Gomel V (2000) Role of microlaparoscopy in the diagnosis of peritoneal and visceral adhesions and in the prevention of bowel injury associated with blind trocar insertion. Fertil Steril 73:631–635CrossRefPubMed Audebert AJ, Gomel V (2000) Role of microlaparoscopy in the diagnosis of peritoneal and visceral adhesions and in the prevention of bowel injury associated with blind trocar insertion. Fertil Steril 73:631–635CrossRefPubMed
Metadaten
Titel
A multicentric prospective study evaluating the safety and efficacy of Kii® Fios® First Entry Trocar in laparoscopic bariatric surgery
verfasst von
Marcelo Loureiro
Mohamad Ramadan
El Mehdi Skalli
Pierre Blanc
Jean Michel Fabre
David Nocca
Publikationsdatum
07.04.2017
Verlag
Springer US
Erschienen in
Surgical Endoscopy / Ausgabe 11/2017
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-017-5536-7

Weitere Artikel der Ausgabe 11/2017

Surgical Endoscopy 11/2017 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.