Abstract

The goal of this study was to confirm the decrease in radiation time required for a new technique to place dynamic hip screws (DHS) in intertrochanteric fractures. Seventy-six patients were treated with DHS by either the new technique (NT) or the conventional technique (CT). The width of femoral shaft, the length of the hip screw to be implanted into the injured side, and the distance between the tip of the greater trochanter and the entry point of the guide wire were measured at the uninjured side on the anteroposterior pelvic radiograph preoperatively, and the actual width of the injured femoral shaft was measured intra-operatively. Finally, the entry point and the length of hip screw were obtained through an equation. Mean radiation time of the NT patients (24.57 ± 7.80 s) was significantly shorter than the CT patients (54.2 ± 18.26 s) (P  < 0.001). The new technique decreased radiation time dramatically in DHS fixation.
Literatur
1.
Zurück zum Zitat Adams JC, Stossel CA (1992) Hip region. In: Standard orthopaedic operations, 4th edn. Churchill Livingstone, London, pp 260–325 Adams JC, Stossel CA (1992) Hip region. In: Standard orthopaedic operations, 4th edn. Churchill Livingstone, London, pp 260–325
2.
Zurück zum Zitat Alobaid A, Harry EJ, Elder GM et al (2004) Prospective randomized trial of two techniques of insertion of a standard dynamic fixation device. J Orthop Trauma 18(4):207–212PubMedCrossRef Alobaid A, Harry EJ, Elder GM et al (2004) Prospective randomized trial of two techniques of insertion of a standard dynamic fixation device. J Orthop Trauma 18(4):207–212PubMedCrossRef
3.
Zurück zum Zitat Aronsson DD, Carlson WE (1992) Slipped capital femoral epiphysis: a prospective study of fixation with a single screw. J Bone Joint Surg Am 74:810–819 Aronsson DD, Carlson WE (1992) Slipped capital femoral epiphysis: a prospective study of fixation with a single screw. J Bone Joint Surg Am 74:810–819
4.
Zurück zum Zitat Baumgaertner MR, Curtin SL, Lindskog DM (1995) The value of the tip-apex distance in predicting failure of peritrochanteric fracture fixation. J Bone Jt Surg 77A:1058–1064 Baumgaertner MR, Curtin SL, Lindskog DM (1995) The value of the tip-apex distance in predicting failure of peritrochanteric fracture fixation. J Bone Jt Surg 77A:1058–1064
5.
Zurück zum Zitat Browbank I, Bouazza-Marouf K, Schnabler J (2000) Roboticassisted internal fixation of hip fractures: a fluoroscopy-based intraoperative registration technique. Proc Inst Mech Eng [H] 214(2):165–179 Browbank I, Bouazza-Marouf K, Schnabler J (2000) Roboticassisted internal fixation of hip fractures: a fluoroscopy-based intraoperative registration technique. Proc Inst Mech Eng [H] 214(2):165–179
6.
Zurück zum Zitat Davis TRC, Sher JL, Horsman A et al (1990) Intertrochanteric femoral fractures: mechanical failure after internal fixation. J Bone Joint Surg [Br] 72-B:26–31 Davis TRC, Sher JL, Horsman A et al (1990) Intertrochanteric femoral fractures: mechanical failure after internal fixation. J Bone Joint Surg [Br] 72-B:26–31
7.
Zurück zum Zitat DeLee JC (1991) Fractures and dislocations of the hip. In: Rockwood CA Jr, Green DP, Bucholz RW et al (eds) Rockwood and Green’s fractures in adults, 3rd edn. ASSH, Philadelphia, PA, pp 1481–1651 DeLee JC (1991) Fractures and dislocations of the hip. In: Rockwood CA Jr, Green DP, Bucholz RW et al (eds) Rockwood and Green’s fractures in adults, 3rd edn. ASSH, Philadelphia, PA, pp 1481–1651
8.
Zurück zum Zitat Genser-Strobl B, Sora MC (2005) Potential of P40 plastination for morphometric hip measurements. Surg Radiol Anat 27:147–151PubMedCrossRef Genser-Strobl B, Sora MC (2005) Potential of P40 plastination for morphometric hip measurements. Surg Radiol Anat 27:147–151PubMedCrossRef
9.
Zurück zum Zitat Haydar AJ, Hussainy Al (2005) ‘‘No high tech’’: a new, non-invasive technique for accurate guide wire placement in the dynamic hip screw fixation of femoral neck fractures. Eur J Orthop Surg Traumatol 15:11–14CrossRef Haydar AJ, Hussainy Al (2005) ‘‘No high tech’’: a new, non-invasive technique for accurate guide wire placement in the dynamic hip screw fixation of femoral neck fractures. Eur J Orthop Surg Traumatol 15:11–14CrossRef
10.
Zurück zum Zitat Hwang L-C, Lo W-H, Chen W-M et al (2001) Intertrochanteric fractures in adults younger than 40 years of age. Arch Orthop Trauma Surg 121:123–126PubMedCrossRef Hwang L-C, Lo W-H, Chen W-M et al (2001) Intertrochanteric fractures in adults younger than 40 years of age. Arch Orthop Trauma Surg 121:123–126PubMedCrossRef
11.
Zurück zum Zitat Karlsson KM, Sernbo I, Obrant KJ et al (1996) Femoral neck geometry and radiographic signs of osteoporosis as predictors of hip fracture. Bone 18:327–330PubMedCrossRef Karlsson KM, Sernbo I, Obrant KJ et al (1996) Femoral neck geometry and radiographic signs of osteoporosis as predictors of hip fracture. Bone 18:327–330PubMedCrossRef
12.
Zurück zum Zitat LaVelle DG (2003) Fractures of hip. In: Canale ST (ed) Campbell’s operative orthopaedics. Elsevier, Philadelphia, PA, pp 2873–2938 LaVelle DG (2003) Fractures of hip. In: Canale ST (ed) Campbell’s operative orthopaedics. Elsevier, Philadelphia, PA, pp 2873–2938
13.
Zurück zum Zitat Lee Y-S, Huang C-R, Liao W-Y et al (2007) Surgical treatment of undisplaced femoral neck fractures in the elderly. Int Orthop 31:677–682CrossRef Lee Y-S, Huang C-R, Liao W-Y et al (2007) Surgical treatment of undisplaced femoral neck fractures in the elderly. Int Orthop 31:677–682CrossRef
14.
Zurück zum Zitat Lee Y-S, Huang H-L, Lo T-Y, Huang C-R (2007) Dynamic hip screw in the treatment of intertrochanteric fractures: a comparison of two fixation methods. Int Orthop 31:683–688PubMedCrossRef Lee Y-S, Huang H-L, Lo T-Y, Huang C-R (2007) Dynamic hip screw in the treatment of intertrochanteric fractures: a comparison of two fixation methods. Int Orthop 31:683–688PubMedCrossRef
15.
Zurück zum Zitat Mahoney FI, Barthel DW (1965) Functional evaluation: the Barthel Index. A simple index of independence useful in scoring improvement in the rehabilitation of the chronically ill. Md State Med J 13:61–65 Mahoney FI, Barthel DW (1965) Functional evaluation: the Barthel Index. A simple index of independence useful in scoring improvement in the rehabilitation of the chronically ill. Md State Med J 13:61–65
16.
Zurück zum Zitat Mainds CC, Newman RJ (1989) Implant failures in patients with proximal fractures of the femur treated with a sliding screw device. Injury 20:98–100PubMedCrossRef Mainds CC, Newman RJ (1989) Implant failures in patients with proximal fractures of the femur treated with a sliding screw device. Injury 20:98–100PubMedCrossRef
17.
Zurück zum Zitat Massie WK (1958) Functional fixation of femoral neck fractures: telescopic nail technique. Clin Orth 12:230–255 Massie WK (1958) Functional fixation of femoral neck fractures: telescopic nail technique. Clin Orth 12:230–255
18.
Zurück zum Zitat McLoughlin S, Wheeler D, Rider J et al (2000) Biomechanical evaluation of the dynamic hip screw with two- and four-hole side plates. J Orthop Trauma 14:318–323PubMedCrossRef McLoughlin S, Wheeler D, Rider J et al (2000) Biomechanical evaluation of the dynamic hip screw with two- and four-hole side plates. J Orthop Trauma 14:318–323PubMedCrossRef
19.
Zurück zum Zitat Patel AR, Boyes C, Shur V (2007) Treatment of stable extra-capsular hip fractures with a sliding screw versus short gamma nail: a retrospective study of 102 patients. Eur J Orthop Surg Traumatol 17:51–56CrossRef Patel AR, Boyes C, Shur V (2007) Treatment of stable extra-capsular hip fractures with a sliding screw versus short gamma nail: a retrospective study of 102 patients. Eur J Orthop Surg Traumatol 17:51–56CrossRef
20.
Zurück zum Zitat Saarenpää I, Heikkinen T, Jalovaara P (2007) Treatment of subtrochanteric fractures. A comparison of the gamma nail and the dynamic hip screw: short-term outcome in 58 patients. Int Orthop 31:65–70PubMedCrossRef Saarenpää I, Heikkinen T, Jalovaara P (2007) Treatment of subtrochanteric fractures. A comparison of the gamma nail and the dynamic hip screw: short-term outcome in 58 patients. Int Orthop 31:65–70PubMedCrossRef
21.
Zurück zum Zitat Schep NW, van Walsum T, De Graaf JS, Broeders IA, van der Werken C (2002) Validation of fluoroscopy-based navigation in the hip region: what you see is what you get? Comput Aided Surg 7(5):279–283PubMedCrossRef Schep NW, van Walsum T, De Graaf JS, Broeders IA, van der Werken C (2002) Validation of fluoroscopy-based navigation in the hip region: what you see is what you get? Comput Aided Surg 7(5):279–283PubMedCrossRef
22.
Zurück zum Zitat Schumpelik W, Jantzen PM (1955) A new principle in the operative treatment of trochanteric fractures of the femur. J Bone Jt Surg 37A:693–698 Schumpelik W, Jantzen PM (1955) A new principle in the operative treatment of trochanteric fractures of the femur. J Bone Jt Surg 37A:693–698
Metadaten
Titel
A new technique for lag screw placement in the dynamic hip screw fixation of intertrochanteric fractures: decreasing radiation time dramatically
verfasst von
Wei-Chao Sheng
Jia-Zhen Li
Sheng-Hua Chen
Shi-Zhen Zhong
Publikationsdatum
01.04.2009
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 2/2009
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-008-0517-z

Weitere Artikel der Ausgabe 2/2009

International Orthopaedics 2/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.