Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 5/2007

01.10.2007 | Review Paper

A practical guide to reading CT coronary angiograms—How to avoid mistakes when assessing for coronary stenoses

verfasst von: John W. M. Hoe, Kok Hong Toh

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 5/2007

Einloggen, um Zugang zu erhalten

Abstract

There are now many physicians, both radiologists and cardiologists who are reporting CT coronary angiography (CTCA) scans who may not be aware that there are many pitfalls present. For the inexperienced reader a significant stenosis in a coronary artery can be easily missed or a moderate stenosis overcalled as significant. Artifacts can also be misinterpreted as representing a significant lesion. It is important that the studies are correctly interpreted, especially as the reported high negative predictive value of CTCA scans is a major strength of this imaging technique. The learning curve of reading these scans is steep and access to conventional coronary catheterisation results is essential for feedback and to improve the readers results. We have developed some rules to aid beginners avoid some of the pitfalls that can occur as these studies are not as easy to read as they may appear initially.
Literatur
1.
Zurück zum Zitat Stein PD, Beemath A, Kayali F et al. (2006) Multidetector computed tomography for the diagnosis of coronary artery disease: a systematic review. Am J Med 119:203–216PubMedCrossRef Stein PD, Beemath A, Kayali F et al. (2006) Multidetector computed tomography for the diagnosis of coronary artery disease: a systematic review. Am J Med 119:203–216PubMedCrossRef
2.
Zurück zum Zitat Garcia MJ, Lessick J, Hoffmann MHK (2006) Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. JAMA 296:403–411PubMedCrossRef Garcia MJ, Lessick J, Hoffmann MHK (2006) Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis. JAMA 296:403–411PubMedCrossRef
3.
Zurück zum Zitat Hoffman MH, Shi H, Schmitz BL et al. (2005) Noninvasive coronary angiography with multislice computed tomography. JAMA 293:2471–2478CrossRef Hoffman MH, Shi H, Schmitz BL et al. (2005) Noninvasive coronary angiography with multislice computed tomography. JAMA 293:2471–2478CrossRef
4.
Zurück zum Zitat Raff GL, Gallager MJ, O’Neill WW, Goldstein JA (2006) Diagnostic accuracy of non invasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557CrossRef Raff GL, Gallager MJ, O’Neill WW, Goldstein JA (2006) Diagnostic accuracy of non invasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557CrossRef
5.
Zurück zum Zitat Ehara M, Surmely JF, Kawai M et al. (2006). Diagnostic accuracy of 64-slice computed tomography fro detecting angiographically significant coronary artery stenosis in an unselected consecutive population: comparison with conventional invasive angiography. Circ J 70:564–571PubMedCrossRef Ehara M, Surmely JF, Kawai M et al. (2006). Diagnostic accuracy of 64-slice computed tomography fro detecting angiographically significant coronary artery stenosis in an unselected consecutive population: comparison with conventional invasive angiography. Circ J 70:564–571PubMedCrossRef
6.
Zurück zum Zitat Becker CR (2005) Coronary CT angiography in symptomatic patients. Eur Radiol l 15(Suppl 2):B33–B41 Becker CR (2005) Coronary CT angiography in symptomatic patients. Eur Radiol l 15(Suppl 2):B33–B41
7.
Zurück zum Zitat Ohnesorge BM, Hofmann LK, Flohr TG, Schoef UJ (2005) CT for imaging of coronary artery disease: defining the paradigm for its application. Int J Cardiovasc Imaging 21:85–104PubMedCrossRef Ohnesorge BM, Hofmann LK, Flohr TG, Schoef UJ (2005) CT for imaging of coronary artery disease: defining the paradigm for its application. Int J Cardiovasc Imaging 21:85–104PubMedCrossRef
8.
Zurück zum Zitat Hendel RC, Patel MR, Kramer CM et al. (2006) ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging. J Am Coll Cardiol 48:1475–1497PubMedCrossRef Hendel RC, Patel MR, Kramer CM et al. (2006) ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging. J Am Coll Cardiol 48:1475–1497PubMedCrossRef
9.
Zurück zum Zitat Hyun SC, Choi BW, Choe KO et al. (2004) Pitfalls, artifacts and remedies in multi-detector row CT coronary angiography. Radiographics 24:787–800CrossRef Hyun SC, Choi BW, Choe KO et al. (2004) Pitfalls, artifacts and remedies in multi-detector row CT coronary angiography. Radiographics 24:787–800CrossRef
10.
Zurück zum Zitat Nakanishi TN, Kayashima Y, Inoue R, Sumii K, Gomyo Y (2005) Pitfalls in 16-detector row CT of the coronary arteries. Radiographics 25:425–440PubMedCrossRef Nakanishi TN, Kayashima Y, Inoue R, Sumii K, Gomyo Y (2005) Pitfalls in 16-detector row CT of the coronary arteries. Radiographics 25:425–440PubMedCrossRef
11.
Zurück zum Zitat Van Oijen PMA, Ho KY, Dorgelo J, Oudkerk M (2003) Coronary artery imaging with multidetector CT: visualisation issues. Radiographics 23:16e. Published online as 10.1148/rg.e16 Van Oijen PMA, Ho KY, Dorgelo J, Oudkerk M (2003) Coronary artery imaging with multidetector CT: visualisation issues. Radiographics 23:16e. Published online as 10.1148/rg.e16
12.
Zurück zum Zitat Achenbach S (2005) Coronary CT angiography: a cardiologist’s perspective. Appl Radiol (Supplement):22–23 Achenbach S (2005) Coronary CT angiography: a cardiologist’s perspective. Appl Radiol (Supplement):22–23
13.
Zurück zum Zitat Lawler LP, Pannu HK, Fishman EK. (2005) MDCT evaluation of the coronary arteries, 2004: how we do it-data acquisition, postprocessing, display and interpretation. AJR 184:1402–1412PubMed Lawler LP, Pannu HK, Fishman EK. (2005) MDCT evaluation of the coronary arteries, 2004: how we do it-data acquisition, postprocessing, display and interpretation. AJR 184:1402–1412PubMed
14.
Zurück zum Zitat Hoffman U, Ferencik M, Cury RC et al. (2006) Coronary CT angiography. J Nucl Med 47:797–806 Hoffman U, Ferencik M, Cury RC et al. (2006) Coronary CT angiography. J Nucl Med 47:797–806
15.
Zurück zum Zitat Gerber TC, Breen JF, Kuzo RS et al. (2006) Computed tomographic angiography of the coronary arteries: techniques and applications. Semin Ultrasound CT MRI 27:42–55CrossRef Gerber TC, Breen JF, Kuzo RS et al. (2006) Computed tomographic angiography of the coronary arteries: techniques and applications. Semin Ultrasound CT MRI 27:42–55CrossRef
16.
Zurück zum Zitat Leber AW, Becker A, Knez A et al. (2006) Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound. J Am Coll Cardiol 47:672–677PubMedCrossRef Leber AW, Becker A, Knez A et al. (2006) Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound. J Am Coll Cardiol 47:672–677PubMedCrossRef
17.
Zurück zum Zitat Cademartiri F, Mollet NR, Ruriza G et al. (2005). Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex-vivo model of coronary computed tomography angiography. Eur Radiol 15:1426–1431PubMedCrossRef Cademartiri F, Mollet NR, Ruriza G et al. (2005). Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex-vivo model of coronary computed tomography angiography. Eur Radiol 15:1426–1431PubMedCrossRef
18.
Zurück zum Zitat Ota H, Takase K, Rikimaru H et al. (2005) Quantitative vascular measurements in arterial occlusive disease. Radiographics 25:1141–1158PubMedCrossRef Ota H, Takase K, Rikimaru H et al. (2005) Quantitative vascular measurements in arterial occlusive disease. Radiographics 25:1141–1158PubMedCrossRef
19.
Zurück zum Zitat Cury RC, Ferencik M, Achenbach S et al. (2006) Accuracy of 16-slice Multidetector CT to quantify the degree of coronary artery stenosis: assessment of cross sectional and longitudinal vessel reconstructions. Eur Radiol 57:345–350CrossRef Cury RC, Ferencik M, Achenbach S et al. (2006) Accuracy of 16-slice Multidetector CT to quantify the degree of coronary artery stenosis: assessment of cross sectional and longitudinal vessel reconstructions. Eur Radiol 57:345–350CrossRef
20.
Zurück zum Zitat Cury RC, Pomerantsev H, Ferencik M et al. (2005) Comparison of the degree of coronary stenoses by multidetector computed tomography versus by quantitative coronary angiography. Am J Cardiol 96:784–787PubMedCrossRef Cury RC, Pomerantsev H, Ferencik M et al. (2005) Comparison of the degree of coronary stenoses by multidetector computed tomography versus by quantitative coronary angiography. Am J Cardiol 96:784–787PubMedCrossRef
21.
Zurück zum Zitat Glagov S, Wisenberg E, Zarins CK et al. (1987) Compensatory enlargement of human atherosclerotic coronary arteries. NEJM 316:1371–1375PubMed Glagov S, Wisenberg E, Zarins CK et al. (1987) Compensatory enlargement of human atherosclerotic coronary arteries. NEJM 316:1371–1375PubMed
22.
Zurück zum Zitat Dewey M, Schnapauff D, Laule M et al. (2004) Multislice CT coronary angiography: evaluation of an automatic vessel detection tool. Fortschr Rontgenstr 176:478–483CrossRef Dewey M, Schnapauff D, Laule M et al. (2004) Multislice CT coronary angiography: evaluation of an automatic vessel detection tool. Fortschr Rontgenstr 176:478–483CrossRef
23.
Zurück zum Zitat Khan MF, Wesarg S, Gurung J et al. (2006) Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool. Eur Radiol 16:1789–1795PubMedCrossRef Khan MF, Wesarg S, Gurung J et al. (2006) Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool. Eur Radiol 16:1789–1795PubMedCrossRef
24.
Zurück zum Zitat Achenbach S, Rerencik M, Ropers D et al. (2005) Diagnostic accuracy of image postprocesing methods for the detection of coronary artery stenoses by multi-detector computed tomography. ESC Congress 2005. Abstract P1016 Achenbach S, Rerencik M, Ropers D et al. (2005) Diagnostic accuracy of image postprocesing methods for the detection of coronary artery stenoses by multi-detector computed tomography. ESC Congress 2005. Abstract P1016
25.
Zurück zum Zitat Becker CR, Hong C, Knez A et al. (2003) Optimal contrast application for cardiac 4 detector row computed tomography. Invest Radiol 38:690–694PubMedCrossRef Becker CR, Hong C, Knez A et al. (2003) Optimal contrast application for cardiac 4 detector row computed tomography. Invest Radiol 38:690–694PubMedCrossRef
26.
Zurück zum Zitat Cademartiri F, Mollet NR, Lemos P et al. (2006) Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR 187:W430–W433PubMedCrossRef Cademartiri F, Mollet NR, Lemos P et al. (2006) Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography. AJR 187:W430–W433PubMedCrossRef
27.
Zurück zum Zitat Jacobs JE, Boxt LM, Desjardins B et al. (2006) ACR practice guideline for the performance & interpretation of cardiac computed tomography. J Am Coll Radiol 3:677–685PubMedCrossRef Jacobs JE, Boxt LM, Desjardins B et al. (2006) ACR practice guideline for the performance & interpretation of cardiac computed tomography. J Am Coll Radiol 3:677–685PubMedCrossRef
28.
Zurück zum Zitat Rumberger JA (2006) Noncardiac abnormalities in diagnostic cardiac computed tomography: within normal limits or we never looked! J Am Coll Cardiol 48:407–408PubMedCrossRef Rumberger JA (2006) Noncardiac abnormalities in diagnostic cardiac computed tomography: within normal limits or we never looked! J Am Coll Cardiol 48:407–408PubMedCrossRef
Metadaten
Titel
A practical guide to reading CT coronary angiograms—How to avoid mistakes when assessing for coronary stenoses
verfasst von
John W. M. Hoe
Kok Hong Toh
Publikationsdatum
01.10.2007
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 5/2007
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-006-9173-9

Weitere Artikel der Ausgabe 5/2007

The International Journal of Cardiovascular Imaging 5/2007 Zur Ausgabe

Die „Zehn Gebote“ des Endokarditis-Managements

30.04.2024 Endokarditis Leitlinie kompakt

Worauf kommt es beim Management von Personen mit infektiöser Endokarditis an? Eine Kardiologin und ein Kardiologe fassen die zehn wichtigsten Punkte der neuen ESC-Leitlinie zusammen.

Strenge Blutdruckeinstellung lohnt auch im Alter noch

30.04.2024 Arterielle Hypertonie Nachrichten

Ältere Frauen, die von chronischen Erkrankungen weitgehend verschont sind, haben offenbar die besten Chancen, ihren 90. Geburtstag zu erleben, wenn ihr systolischer Blutdruck < 130 mmHg liegt. Das scheint selbst für 80-Jährige noch zu gelten.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Dihydropyridin-Kalziumantagonisten können auf die Nieren gehen

30.04.2024 Hypertonie Nachrichten

Im Vergleich zu anderen Blutdrucksenkern sind Kalziumantagonisten vom Diyhdropyridin-Typ mit einem erhöhten Risiko für eine Mikroalbuminurie und in Abwesenheit eines RAS-Blockers auch für ein terminales Nierenversagen verbunden.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.