Abstract

Pediatric ventricular assist device (VAD) implantation outcomes are increasingly promising for children with dilated cardiomyopathy and advanced decompensated heart failure (ADHF). VAD placement in patients with clinical features such as complex congenital cardiac anatomy, small body size, or major comorbidities remains problematic. These comorbidities have been traditionally prohibitive for VAD consideration leaving these children as a treatment-orphaned population. Here we describe the quality bundle surrounding these patients with ADHF considered high risk for VAD implantation at our institution. Over a 7-year period, a quality bundle aimed at the peri-operative care for children with high-risk features undergoing VAD implantation was incrementally implemented at a tertiary children’s hospital. Patients were considered high risk if they were neonates (< 30 days), had single-ventricle physiology, non-dilated cardiomyopathy, biventricular dysfunction, or significant comorbidities. The quality improvement bundle evolved to include (1) structured team-based peri-operative evaluation, (2) weekly VAD rounds addressing post-operative device performance, (3) standardized anticoagulation strategies, and (4) a multidisciplinary system for management challenges. These measures aimed to improve communication, standardize management, allow for ongoing process improvement, and incorporate principles of a high-reliability organization. Between January 2010 and December 2017, 98 patients underwent VAD implantation, 48 (49%) of which had high-risk comorbidities and a resultant cohort survival-to-transplant rate of 65%. We report on the evolution of a quality improvement program to expand the scope of VAD implantation to patients with high-risk clinical profiles. This quality bundle can serve as a template for future large-scale collaborations to improve outcomes in these treatment-orphaned subgroups.
Literatur
1.
Zurück zum Zitat Fraser CD Jr, Jaquiss RD (2013) The Berlin heart EXCOR pediatric ventricular assist device: history, North American experience, and future directions. Ann N Y Acad Sci 1291:96–105CrossRef Fraser CD Jr, Jaquiss RD (2013) The Berlin heart EXCOR pediatric ventricular assist device: history, North American experience, and future directions. Ann N Y Acad Sci 1291:96–105CrossRef
2.
Zurück zum Zitat Blume ED, VanderPluym C, Lorts A et al (2018) Second annual pediatric interagency registry for mechanical circulatory support (Pedimacs) report: pre-implant characteristics and outcomes. J Heart Lung Transplant 37(1):38–45CrossRef Blume ED, VanderPluym C, Lorts A et al (2018) Second annual pediatric interagency registry for mechanical circulatory support (Pedimacs) report: pre-implant characteristics and outcomes. J Heart Lung Transplant 37(1):38–45CrossRef
3.
Zurück zum Zitat Dipchand AI, Kirk R, Naftel DC et al (2018) Ventricular assist device support as a bridge to transplantation in pediatric patients. J Am Coll Cardiol 72(4):402–415CrossRef Dipchand AI, Kirk R, Naftel DC et al (2018) Ventricular assist device support as a bridge to transplantation in pediatric patients. J Am Coll Cardiol 72(4):402–415CrossRef
4.
Zurück zum Zitat Burki S, Adachi I (2017) Pediatric ventricular assist devices: current challenges and future prospects. Vasc Health Risk Manag 13:177–185CrossRef Burki S, Adachi I (2017) Pediatric ventricular assist devices: current challenges and future prospects. Vasc Health Risk Manag 13:177–185CrossRef
5.
Zurück zum Zitat Zafar F, Castleberry C, Khan MS et al (2015) Pediatric heart transplant waiting list mortality in the era of ventricular assist devices. J Heart Lung Transplant 34(1):82–88CrossRef Zafar F, Castleberry C, Khan MS et al (2015) Pediatric heart transplant waiting list mortality in the era of ventricular assist devices. J Heart Lung Transplant 34(1):82–88CrossRef
6.
Zurück zum Zitat Almond CS, Morales DL, Blackstone EH et al (2013) Berlin heart EXCOR pediatric ventricular assist device for bridge to heart transplantation in US children. Circulation 127(16):1702–1711CrossRef Almond CS, Morales DL, Blackstone EH et al (2013) Berlin heart EXCOR pediatric ventricular assist device for bridge to heart transplantation in US children. Circulation 127(16):1702–1711CrossRef
7.
Zurück zum Zitat Maeda K, Rosenthal DN, Reinhartz O (2018) Ventricular assist devices for neonates and infants. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 21:9–14CrossRef Maeda K, Rosenthal DN, Reinhartz O (2018) Ventricular assist devices for neonates and infants. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 21:9–14CrossRef
8.
Zurück zum Zitat Weinstein S, Bello R, Pizarro C, et al (2014) The use of the Berlin heart EXCOR in patients with functional single ventricle. J Thorac Cardiovasc Surg 147(2):697–704 (discussion 704–695).CrossRef Weinstein S, Bello R, Pizarro C, et al (2014) The use of the Berlin heart EXCOR in patients with functional single ventricle. J Thorac Cardiovasc Surg 147(2):697–704 (discussion 704–695).CrossRef
9.
Zurück zum Zitat Fraser CD Jr, Jaquiss RD, Rosenthal DN et al (2012) Prospective trial of a pediatric ventricular assist device. N Engl J Med 367(6):532–541CrossRef Fraser CD Jr, Jaquiss RD, Rosenthal DN et al (2012) Prospective trial of a pediatric ventricular assist device. N Engl J Med 367(6):532–541CrossRef
10.
Zurück zum Zitat Magnetta DA, Kang J, Wearden PD, Smith KJ, Feingold B (2018) Cost-effectiveness of ventricular assist device destination therapy for advanced heart failure in duchenne muscular dystrophy. Pediatr Cardiol 39:1242–1248CrossRef Magnetta DA, Kang J, Wearden PD, Smith KJ, Feingold B (2018) Cost-effectiveness of ventricular assist device destination therapy for advanced heart failure in duchenne muscular dystrophy. Pediatr Cardiol 39:1242–1248CrossRef
11.
Zurück zum Zitat Seguchi O, Kuroda K, Fujita T, Fukushima N, Nakatani T (2016) Advanced heart failure secondary to muscular dystrophy: clinical outcomes after left ventricular assist device implantation. J Heart Lung Transplant 35(6):831–834CrossRef Seguchi O, Kuroda K, Fujita T, Fukushima N, Nakatani T (2016) Advanced heart failure secondary to muscular dystrophy: clinical outcomes after left ventricular assist device implantation. J Heart Lung Transplant 35(6):831–834CrossRef
12.
Zurück zum Zitat Nunes AJ, Buchholz H, Sinnadurai S, MacArthur RG (2012) Long-term mechanical circulatory support of an adult patient with down syndrome. Ann Thorac Surg 93(4):1305–1307CrossRef Nunes AJ, Buchholz H, Sinnadurai S, MacArthur RG (2012) Long-term mechanical circulatory support of an adult patient with down syndrome. Ann Thorac Surg 93(4):1305–1307CrossRef
13.
Zurück zum Zitat Jeewa A, Manlhiot C, McCrindle BW, Van Arsdell G, Humpl T, Dipchand AI (2010) Outcomes with ventricular assist device versus extracorporeal membrane oxygenation as a bridge to pediatric heart transplantation. Artif Organs 34(12):1087–1091CrossRef Jeewa A, Manlhiot C, McCrindle BW, Van Arsdell G, Humpl T, Dipchand AI (2010) Outcomes with ventricular assist device versus extracorporeal membrane oxygenation as a bridge to pediatric heart transplantation. Artif Organs 34(12):1087–1091CrossRef
14.
Zurück zum Zitat Ford MA, Gauvreau K, McMullan DM et al (2016) Factors associated with mortality in neonates requiring extracorporeal membrane oxygenation for cardiac indications: analysis of the extracorporeal life support organization registry data. Pediatr Crit Care Med 17(9):860–870CrossRef Ford MA, Gauvreau K, McMullan DM et al (2016) Factors associated with mortality in neonates requiring extracorporeal membrane oxygenation for cardiac indications: analysis of the extracorporeal life support organization registry data. Pediatr Crit Care Med 17(9):860–870CrossRef
15.
Zurück zum Zitat Misfeldt AM, Kirsch RE, Goldberg DJ et al (2016) Outcomes of single-ventricle patients supported with extracorporeal membrane oxygenation. Pediatr Crit Care Med 17(3):194–202CrossRef Misfeldt AM, Kirsch RE, Goldberg DJ et al (2016) Outcomes of single-ventricle patients supported with extracorporeal membrane oxygenation. Pediatr Crit Care Med 17(3):194–202CrossRef
16.
Zurück zum Zitat Dipchand AI, Mahle WT, Tresler M et al (2015) Extracorporeal membrane oxygenation as a bridge to pediatric heart transplantation: effect on post-listing and post-transplantation outcomes. Circ Heart Fail 8(5):960–969CrossRef Dipchand AI, Mahle WT, Tresler M et al (2015) Extracorporeal membrane oxygenation as a bridge to pediatric heart transplantation: effect on post-listing and post-transplantation outcomes. Circ Heart Fail 8(5):960–969CrossRef
17.
Zurück zum Zitat Alert SE (2017) Inadequate hand-off communication. Sentinel Event Alert 58:1–6. Alert SE (2017) Inadequate hand-off communication. Sentinel Event Alert 58:1–6.
18.
Zurück zum Zitat Alvarez G, Coiera E (2006) Interdisciplinary communication: an uncharted source of medical error? J Crit Care 21(3):236–242 (discussion 242)CrossRef Alvarez G, Coiera E (2006) Interdisciplinary communication: an uncharted source of medical error? J Crit Care 21(3):236–242 (discussion 242)CrossRef
19.
Zurück zum Zitat Ohno T (1988) Toyota production system: beyond large-scale production. Productivity Press, Portland Ohno T (1988) Toyota production system: beyond large-scale production. Productivity Press, Portland
20.
Zurück zum Zitat Hirano H, Furuya M (2006) JIT is flow: practice and principles of lean manufacturing. PCS Press, Inc, Portland Hirano H, Furuya M (2006) JIT is flow: practice and principles of lean manufacturing. PCS Press, Inc, Portland
21.
Zurück zum Zitat Wilson KA, Burke CS, Priest HA, Salas E (2005) Promoting health care safety through training high reliability teams. Qual Saf Health Care 14(4):303–309CrossRef Wilson KA, Burke CS, Priest HA, Salas E (2005) Promoting health care safety through training high reliability teams. Qual Saf Health Care 14(4):303–309CrossRef
22.
Zurück zum Zitat Ke W, Km S (2007) Managing the unexpected: resilient performance in an age of uncertainty. Jossey-Bass, Portland Ke W, Km S (2007) Managing the unexpected: resilient performance in an age of uncertainty. Jossey-Bass, Portland
23.
Zurück zum Zitat Massicotte MP, Bauman ME, Murray J, Almond CS (2015) Antithrombotic therapy for ventricular assist devices in children: do we really know what to do? J Thromb Haemost 13(Suppl 1):S343–350CrossRef Massicotte MP, Bauman ME, Murray J, Almond CS (2015) Antithrombotic therapy for ventricular assist devices in children: do we really know what to do? J Thromb Haemost 13(Suppl 1):S343–350CrossRef
24.
Zurück zum Zitat Adachi I, Kostousov V, Hensch L, Chacon-Portillo MA, Teruya J (2018) Management of hemostasis for pediatric patients on ventricular-assist devices. Semin Thromb Hemost 44(1):30–37CrossRef Adachi I, Kostousov V, Hensch L, Chacon-Portillo MA, Teruya J (2018) Management of hemostasis for pediatric patients on ventricular-assist devices. Semin Thromb Hemost 44(1):30–37CrossRef
Metadaten
Titel
A Quality Bundle to Support High-Risk Pediatric Ventricular Assist Device Implantation
verfasst von
Christopher Knoll
Sharon Chen
Jenna M. Murray
John C. Dykes
Vamsi V. Yarlagadda
David N. Rosenthal
Christopher S. Almond
Katsuhide Maeda
Andrew Y. Shin
Publikationsdatum
13.05.2019
Verlag
Springer US
Erschienen in
Pediatric Cardiology / Ausgabe 6/2019
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-019-02123-1

Weitere Artikel der Ausgabe 6/2019

Pediatric Cardiology 6/2019 Zur Ausgabe

Vorsicht, erhöhte Blutungsgefahr nach PCI!

10.05.2024 Koronare Herzerkrankung Nachrichten

Nach PCI besteht ein erhöhtes Blutungsrisiko, wenn die Behandelten eine verminderte linksventrikuläre Ejektionsfraktion aufweisen. Das Risiko ist umso höher, je stärker die Pumpfunktion eingeschränkt ist.

Triglyzeridsenker schützt nicht nur Hochrisikopatienten

10.05.2024 Hypercholesterinämie Nachrichten

Patienten mit Arteriosklerose-bedingten kardiovaskulären Erkrankungen, die trotz Statineinnahme zu hohe Triglyzeridspiegel haben, profitieren von einer Behandlung mit Icosapent-Ethyl, und zwar unabhängig vom individuellen Risikoprofil.

Gibt es eine Wende bei den bioresorbierbaren Gefäßstützen?

In den USA ist erstmals eine bioresorbierbare Gefäßstütze – auch Scaffold genannt – zur Rekanalisation infrapoplitealer Arterien bei schwerer PAVK zugelassen worden. Das markiert einen Wendepunkt in der Geschichte dieser speziellen Gefäßstützen.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.