Skip to main content
Erschienen in: Acta Neurochirurgica 4/2021

21.01.2021 | Original Article - Neurosurgical technique evaluation

Accuracy of bolt external ventricular drain insertion by neurosurgeons of different experience

verfasst von: Ivan Cabrilo, Claudia L. Craven, Debayan Dasgupta, Ugan Reddy, Ahmed K. Toma

Erschienen in: Acta Neurochirurgica | Ausgabe 4/2021

Einloggen, um Zugang zu erhalten

Abstract

Objective

The accuracy of tunneled external ventricular drain (EVD) placement has been shown to be similar among practitioners of varying experience, but this has not yet been investigated for bolt EVDs. Tunneled and bolt EVDs are distinct techniques, and it is unclear if conclusions regarding accuracy can be inferred from one method to the other. The goal of this study was to determine whether neurosurgical experience influences the accuracy of bolt EVD placement.

Methods

We performed a single-center retrospective analysis of accuracy of bolt EVD placement between 1st December 2018 and 31st May 2020, comparing the accuracy outcomes between three levels of training (junior trainees (JT); mid-grade trainees (MT); senior trainees/fellows (ST)). Accuracy was determined radiologically by two methods: Kakarla grade and by measuring the distance of the catheter tip to its optimal position (DTOP) at the foramen of Monro.

Results

Eighty-seven patients underwent insertion of bolt EVDs, of which n = 19 by JT, n = 40 by MT and n = 28 by ST, with a significant difference found between training grades in the median Kakarla grade (p = 0.0055) and in the accuracy of placement as per DTOP (p = 0.0168).

Conclusions

In contrast to previous published results on tunneled EVDs, we demonstrate that the accuracy of bolt EVD placement is dependent on neurosurgical experience. Our results draw awareness to the fact that the bolt EVD technique can represent a challenge for less experienced practitioners and underline the importance of dedicated training to support the safe insertion of bolt ventricular catheters.
Literatur
3.
Zurück zum Zitat Cabrilo I, Craven CL, Abuhusain H, Pradini-Santos L, Asif H, Marcus HJ, Reddy U, Watkins LD, Toma AK (2020) Neuronavigation-assisted bedside placement of bolt external ventricular drains in the intensive care setting: a technical note. Acta Neurochir. https://doi.org/10.1007/s00701-020-04634-w Cabrilo I, Craven CL, Abuhusain H, Pradini-Santos L, Asif H, Marcus HJ, Reddy U, Watkins LD, Toma AK (2020) Neuronavigation-assisted bedside placement of bolt external ventricular drains in the intensive care setting: a technical note. Acta Neurochir. https://​doi.​org/​10.​1007/​s00701-020-04634-w
5.
Zurück zum Zitat Enriquez-Marulanda A, Ascanio LC, Salem MM, Maragkos GA, Jhun R, Alturki AY, Moore JM, Ogilvy CS, Thomas AJ (2018) Accuracy and safety of external ventricular drain placement by physician assistants and nurse practitioners in aneurysmal acute subarachnoid hemorrhage. Neurocrit Care 29:435–442. https://doi.org/10.1007/s12028-018-0556-2CrossRefPubMed Enriquez-Marulanda A, Ascanio LC, Salem MM, Maragkos GA, Jhun R, Alturki AY, Moore JM, Ogilvy CS, Thomas AJ (2018) Accuracy and safety of external ventricular drain placement by physician assistants and nurse practitioners in aneurysmal acute subarachnoid hemorrhage. Neurocrit Care 29:435–442. https://​doi.​org/​10.​1007/​s12028-018-0556-2CrossRefPubMed
7.
Zurück zum Zitat Greenberg SM (2010) Handbook of neurosurgery, 7th edn. Thieme, New York Greenberg SM (2010) Handbook of neurosurgery, 7th edn. Thieme, New York
9.
Zurück zum Zitat Mansoor N, Madsbu MA, Mansoor NM, Tronnes AN, Fredriksli OA, Salvesen O, Jakola AS, Solheim O, Gulati S (2020) Accuracy and complication rates of external ventricular drain placement with twist drill and bolt system versus standard trephine and tunnelation: a retrospective population-based study. Acta Neurochir 162:755–761. https://doi.org/10.1007/s00701-020-04247-3CrossRefPubMed Mansoor N, Madsbu MA, Mansoor NM, Tronnes AN, Fredriksli OA, Salvesen O, Jakola AS, Solheim O, Gulati S (2020) Accuracy and complication rates of external ventricular drain placement with twist drill and bolt system versus standard trephine and tunnelation: a retrospective population-based study. Acta Neurochir 162:755–761. https://​doi.​org/​10.​1007/​s00701-020-04247-3CrossRefPubMed
Metadaten
Titel
Accuracy of bolt external ventricular drain insertion by neurosurgeons of different experience
verfasst von
Ivan Cabrilo
Claudia L. Craven
Debayan Dasgupta
Ugan Reddy
Ahmed K. Toma
Publikationsdatum
21.01.2021
Verlag
Springer Vienna
Erschienen in
Acta Neurochirurgica / Ausgabe 4/2021
Print ISSN: 0001-6268
Elektronische ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-021-04712-7

Weitere Artikel der Ausgabe 4/2021

Acta Neurochirurgica 4/2021 Zur Ausgabe

Letter to the editor - Neurosurgical technique evaluation

Endoscopic microvascular decompression for glossopharyngeal neuralgia

Editorial (by Invitation) - Obituary

Evandro de Oliveira, the “Brain Whisperer”

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.