Skip to main content
Erschienen in: Journal of Medical Systems 5/2011

01.10.2011 | ORIGINAL PAPER

An Efficient Automated Algorithm to Detect Ocular Surface Temperature on Sequence of Thermograms Using Snake and Target Tracing Function

verfasst von: Jen Hong Tan, E. Y. K. Ng, Rajendra Acharya U

Erschienen in: Journal of Medical Systems | Ausgabe 5/2011

Einloggen, um Zugang zu erhalten

Abstract

Functional infrared (IR) imaging is widely adopted in medical field nowadays, with more emphasis on breast cancer and ocular abnormalities. In this article, an algorithm is presented to accurately locate the eye and cornea in ocular thermographic sequences, which were recorded utilizing functional infrared imaging. The localization is achieved by snake algorithm coupled with a newly proposed target tracing function. The target tracing function enables automated localization, allows the absence of any manual assistance before the algorithm runs. Genetic algorithm is used to perform the search for global minimum on the function to produce desired localization. On all the cases we have studied, in average the region encircled by the algorithm covers 92% of the true ocular region. As for the non-ocular region covered, it only accounts for less than 5% of the encircled region.
Literatur
1.
Zurück zum Zitat Holmberg, A., The temperature of the eye during application of hot packs and after milk injections. Acta Ophthalmol. (Copenhagen) 30(4):347–364, 1952.CrossRef Holmberg, A., The temperature of the eye during application of hot packs and after milk injections. Acta Ophthalmol. (Copenhagen) 30(4):347–364, 1952.CrossRef
2.
Zurück zum Zitat Tan, J. H., Ng, E. Y. K., Acharya, U. R., and Chee, C., Infrared thermography on ocular surface temperature: A review. Infrared Phys. Technol. 52:97–108, 2009.CrossRef Tan, J. H., Ng, E. Y. K., Acharya, U. R., and Chee, C., Infrared thermography on ocular surface temperature: A review. Infrared Phys. Technol. 52:97–108, 2009.CrossRef
3.
Zurück zum Zitat Fatt, I., and Forester, J. F., Errors in eye tissue temperature measurements when using a metallic probe. Exp. Eye Res. 14(3):270–276, 1972.CrossRef Fatt, I., and Forester, J. F., Errors in eye tissue temperature measurements when using a metallic probe. Exp. Eye Res. 14(3):270–276, 1972.CrossRef
4.
Zurück zum Zitat Rosenbluth, R. F., and Fatt, I., Temperature measurements in the eye. Exp. Eye Res. 25(4):325–341, 1977.CrossRef Rosenbluth, R. F., and Fatt, I., Temperature measurements in the eye. Exp. Eye Res. 25(4):325–341, 1977.CrossRef
5.
Zurück zum Zitat Efron, N., Young, G., and Brennan, N., Ocular surface temperature. Curr. Eye Res. 8(9):901–906, 1989. Efron, N., Young, G., and Brennan, N., Ocular surface temperature. Curr. Eye Res. 8(9):901–906, 1989.
6.
Zurück zum Zitat Tan, J.-H., Ng, E. Y. K., Acharya, U. R., and Chee, C., Study of normal ocular thermogram using textural parameters. Infrared Phys. Technol. 53(2):120–126, 2010.CrossRef Tan, J.-H., Ng, E. Y. K., Acharya, U. R., and Chee, C., Study of normal ocular thermogram using textural parameters. Infrared Phys. Technol. 53(2):120–126, 2010.CrossRef
7.
Zurück zum Zitat Morgan, P. B., Soh, M. P., and Efron, N., Corneal surface temperature decrease with age. Contact Lens Anterior Eye 22(1):11–13, 1999.CrossRef Morgan, P. B., Soh, M. P., and Efron, N., Corneal surface temperature decrease with age. Contact Lens Anterior Eye 22(1):11–13, 1999.CrossRef
8.
Zurück zum Zitat Purslow, C., Wolffsohn, J. S., and Santodomingo-Rubido, J., The effect of contact lens wear on dynamic ocular surface temperature. Contact Lens Anterior Eye 28:29–36, 2005.CrossRef Purslow, C., Wolffsohn, J. S., and Santodomingo-Rubido, J., The effect of contact lens wear on dynamic ocular surface temperature. Contact Lens Anterior Eye 28:29–36, 2005.CrossRef
9.
Zurück zum Zitat Chiang, H. K., Chen, C. Y., Cheng, H. Y., Chen, K.-H., and Chang, D. O., Development of infrared thermal imager for dry eye diagnosis, in Proceedings of SPIE—The International Society for Optical Engineering, San Diego, CA, USA, 2006. Chiang, H. K., Chen, C. Y., Cheng, H. Y., Chen, K.-H., and Chang, D. O., Development of infrared thermal imager for dry eye diagnosis, in Proceedings of SPIE—The International Society for Optical Engineering, San Diego, CA, USA, 2006.
10.
Zurück zum Zitat Alio, J., and Padron, M., Normal variations in the thermographic pattern of the orbitoocular regionocular region. Diagn. Imaging 51(2):93–98, 1982. Alio, J., and Padron, M., Normal variations in the thermographic pattern of the orbitoocular regionocular region. Diagn. Imaging 51(2):93–98, 1982.
11.
Zurück zum Zitat Morgan, P. B., Soh, M. P., Efron, N., and Tullo, A. B., Potential applications of ocular thermography. Optom. Vis. Sci. 70(7):568–576, 1993.CrossRef Morgan, P. B., Soh, M. P., Efron, N., and Tullo, A. B., Potential applications of ocular thermography. Optom. Vis. Sci. 70(7):568–576, 1993.CrossRef
12.
Zurück zum Zitat Acharya, U. R., Ng, E., Yee, G., Hua, T., and Kagathi, M., Analysis of normal human eye with different age groups using infrared images. J. Med. Syst. 33(3):207–213, 2009.CrossRef Acharya, U. R., Ng, E., Yee, G., Hua, T., and Kagathi, M., Analysis of normal human eye with different age groups using infrared images. J. Med. Syst. 33(3):207–213, 2009.CrossRef
13.
Zurück zum Zitat Tan, J. H., Ng, E. Y. K., and Acharya, U. R., Detection of eye and cornea on IR thermogram using genetic snake algorithm, in 9th International Conference on Quantitative Infrared Thermography, Krakow, Poland, 143–150, 2008. Tan, J. H., Ng, E. Y. K., and Acharya, U. R., Detection of eye and cornea on IR thermogram using genetic snake algorithm, in 9th International Conference on Quantitative Infrared Thermography, Krakow, Poland, 143–150, 2008.
14.
Zurück zum Zitat Tan, J. H., Ng, E. Y. K., and Acharya, U. R., Automated detection of eye and cornea on infrared thermogram using snake and target tracing function coupled with genetic algorithm. Quantitative InfraRed Thermography International Journal 6(1):21–36, 2009.CrossRef Tan, J. H., Ng, E. Y. K., and Acharya, U. R., Automated detection of eye and cornea on infrared thermogram using snake and target tracing function coupled with genetic algorithm. Quantitative InfraRed Thermography International Journal 6(1):21–36, 2009.CrossRef
15.
Zurück zum Zitat Kass, M., Witkin, A., and Terzopoulos, D., Snakes: active contour models. Int. J. Comput. Vision 1:321–331, 1988.CrossRef Kass, M., Witkin, A., and Terzopoulos, D., Snakes: active contour models. Int. J. Comput. Vision 1:321–331, 1988.CrossRef
16.
17.
Zurück zum Zitat Schindler, K., and Suter, D., Object detection by global contour shape. Pattern Recognit. 41(12):3736–3748, 2008.CrossRefMATH Schindler, K., and Suter, D., Object detection by global contour shape. Pattern Recognit. 41(12):3736–3748, 2008.CrossRefMATH
18.
Zurück zum Zitat Montanari, U., On the optimal detection of curves in noisy pictures. Commun. ACM 14(5):335–345, 1971.CrossRefMATH Montanari, U., On the optimal detection of curves in noisy pictures. Commun. ACM 14(5):335–345, 1971.CrossRefMATH
19.
Zurück zum Zitat Martelli, A., Edge detection using heurisitic search methods, 1972. Martelli, A., Edge detection using heurisitic search methods, 1972.
20.
Zurück zum Zitat Blake, A., and Yuille, A. (Eds.), Active vision. MIT, Cambridge, 1992. Blake, A., and Yuille, A. (Eds.), Active vision. MIT, Cambridge, 1992.
21.
Zurück zum Zitat Menet, S., Saint-Marc, P., Medioni, and G., B-snakes: Implementations and applications to setero, in Proc. DARPA Image Understanding Workshop. Pittsburgh, PA, 720–726, 1990. Menet, S., Saint-Marc, P., Medioni, and G., B-snakes: Implementations and applications to setero, in Proc. DARPA Image Understanding Workshop. Pittsburgh, PA, 720–726, 1990.
22.
Zurück zum Zitat Staib, L. H., and Duncan, J. S., Parametrically deformable contour models, in Proc. Computer Vision and Pattern Recognition, San Diego, CA, 1989. Staib, L. H., and Duncan, J. S., Parametrically deformable contour models, in Proc. Computer Vision and Pattern Recognition, San Diego, CA, 1989.
23.
Zurück zum Zitat Cohen, L. D., and Cohen, I., A finite element method applied to new active contour models and 3D reconstruction from cross sections, in IEEE Computer Society Conference, Osaka, Japan, 587–591, 1990. Cohen, L. D., and Cohen, I., A finite element method applied to new active contour models and 3D reconstruction from cross sections, in IEEE Computer Society Conference, Osaka, Japan, 587–591, 1990.
24.
Zurück zum Zitat Liang, J., McInerney, T., and Terzopoulos, D., United snakes. Med. Image Anal. 10(2):215–233, 2006.CrossRef Liang, J., McInerney, T., and Terzopoulos, D., United snakes. Med. Image Anal. 10(2):215–233, 2006.CrossRef
25.
Zurück zum Zitat Tan, J. H., Ng, E. Y. K., Acharya, U. R., and Chee, C., Automated study of ocular thermal images: Comprehensive analysis of corneal health with different age group subjects and validation (accepted), Digital Signal Processing, 2010. Tan, J. H., Ng, E. Y. K., Acharya, U. R., and Chee, C., Automated study of ocular thermal images: Comprehensive analysis of corneal health with different age group subjects and validation (accepted), Digital Signal Processing, 2010.
26.
Zurück zum Zitat Mori, A., Oguchi, Y., Okusawa, Y., Ono, M., Fujishima, H., and Tsubota, K., Use of high-speed, high-resolution thermography to evaluate the tear film layer. Am. J. Ophthalmol. 124(6):729–735, 1997. Mori, A., Oguchi, Y., Okusawa, Y., Ono, M., Fujishima, H., and Tsubota, K., Use of high-speed, high-resolution thermography to evaluate the tear film layer. Am. J. Ophthalmol. 124(6):729–735, 1997.
Metadaten
Titel
An Efficient Automated Algorithm to Detect Ocular Surface Temperature on Sequence of Thermograms Using Snake and Target Tracing Function
verfasst von
Jen Hong Tan
E. Y. K. Ng
Rajendra Acharya U
Publikationsdatum
01.10.2011
Verlag
Springer US
Erschienen in
Journal of Medical Systems / Ausgabe 5/2011
Print ISSN: 0148-5598
Elektronische ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-010-9552-6

Weitere Artikel der Ausgabe 5/2011

Journal of Medical Systems 5/2011 Zur Ausgabe