Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 12/2017

18.05.2017 | Original Paper

Assessment of coronary artery by prospective ECG-triggered 256 multi-slice CT on children with congenital heart disease

verfasst von: Li-Ping Yao, Li Zhang, Hui-Ming Li, Ming Ding, Ling-Wei Yu, Xin Yang, Xiao-Ming Li, Kun Sun

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 12/2017

Einloggen, um Zugang zu erhalten

Abstract

This study aims to investigate the imaging quality and radiation dose of prospective ECG-triggered 256 multi-slice computer tomography (MSCT) in accessing the coronary artery (CA) in children. Coronary arteries of 149 children were evaluated using prospective ECG-triggered 256 MSCT with the same system settings. A four-point scoring system was applied to study the capability of MSCT in detecting CA in these patients. Signal, noise and contrast-to-noise ratios (CNR) were analyzed to investigate the association of image quality with age. Then, volumetric CT dose index (CTDIvol), dose-length product (DLP), and effective dose (ED) were utilized to study the association of radiation dose with age. The detection rate for original, proximal, middle, distal and the 11 segments of CA was 100, 97, 92, 81 and 92%, respectively; and there was no influence on age during the detection (all, P < 0.05). A negative correlation was found between ED and age (r = −0.664, P < 0.001). Significantly larger EDs were found in younger patients (age: <3 years; 1.2 ± 0.5 and 0.6 ± 0.2 mSv; P < 0.001), while higher DLPs were found in elder patients, although no correlation was found between ages versus DLP (r = 0.092, P = 0.262). Prospective ECG-triggered 256 MSCT has considerable performance for the evaluation of CA in children. However, great caution is needed for children under the age of three in the selection of this examination. Furthermore, the tube current could be further reduced for the examination of children ≥8 years.
Literatur
1.
Zurück zum Zitat Goo HW, Park IS, Ko JK, Kim YH, Seo DM, Yun TJ, Park JJ (2005) Visibility of the origin and proximal course of coronary arteries on non-ECG-gated heart CT in patients with congenital heart disease. Pediatr Radiol 35:792–798CrossRefPubMed Goo HW, Park IS, Ko JK, Kim YH, Seo DM, Yun TJ, Park JJ (2005) Visibility of the origin and proximal course of coronary arteries on non-ECG-gated heart CT in patients with congenital heart disease. Pediatr Radiol 35:792–798CrossRefPubMed
2.
Zurück zum Zitat Tsai IC, Lee T, Chen MC, Fu YC, Jan SL, Wang CC, Chang Y (2007) Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique. Pediatr Radiol 37:818–825CrossRefPubMed Tsai IC, Lee T, Chen MC, Fu YC, Jan SL, Wang CC, Chang Y (2007) Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique. Pediatr Radiol 37:818–825CrossRefPubMed
3.
Zurück zum Zitat Sabri N (1994) Complications of cardiac catheterization, coronary angiography, and coronary interventions. J Invasive Cardiol 6:300–305PubMed Sabri N (1994) Complications of cardiac catheterization, coronary angiography, and coronary interventions. J Invasive Cardiol 6:300–305PubMed
4.
Zurück zum Zitat Bacher K, Bogaert E, Lapere R, De Wolf D, Thierens H (2005) Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 111:83–89CrossRefPubMed Bacher K, Bogaert E, Lapere R, De Wolf D, Thierens H (2005) Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 111:83–89CrossRefPubMed
5.
Zurück zum Zitat Thomas KE, Wang B (2008) Age-specific effective doses for pediatric MSCT examinations at a large children’s hospital using DLP conversion coefficients: a simple estimation method. Pediatr Radiol 38:645–656CrossRefPubMed Thomas KE, Wang B (2008) Age-specific effective doses for pediatric MSCT examinations at a large children’s hospital using DLP conversion coefficients: a simple estimation method. Pediatr Radiol 38:645–656CrossRefPubMed
6.
Zurück zum Zitat Dougeni E, Faulkner K, Panayiotakis G (2012) A review of patient dose and optimisation methods in adult and paediatric CT scanning. Eur J Radiol 81:e665–e683CrossRefPubMed Dougeni E, Faulkner K, Panayiotakis G (2012) A review of patient dose and optimisation methods in adult and paediatric CT scanning. Eur J Radiol 81:e665–e683CrossRefPubMed
7.
Zurück zum Zitat Karabay KO, Yildiz A, Geceer G, Uysal E, Bagirtan B (2013) The incidence of coronary anomalies on routine coronary computed tomography scans. Cardiovasc J Afr 24:351–354CrossRefPubMedPubMedCentral Karabay KO, Yildiz A, Geceer G, Uysal E, Bagirtan B (2013) The incidence of coronary anomalies on routine coronary computed tomography scans. Cardiovasc J Afr 24:351–354CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Roura G, Gomez-Lara J, Ferreiro JL, Gomez-Hospital JA, Romaguera R, Teruel LM, Carreño E, Esplugas E, Alfonso F, Cequier A (2013) Multislice CT for assessing in-stent dimensions after left main coronary artery stenting: a comparison with three dimensional intravascular ultrasound. Heart 99:1106–1112CrossRefPubMed Roura G, Gomez-Lara J, Ferreiro JL, Gomez-Hospital JA, Romaguera R, Teruel LM, Carreño E, Esplugas E, Alfonso F, Cequier A (2013) Multislice CT for assessing in-stent dimensions after left main coronary artery stenting: a comparison with three dimensional intravascular ultrasound. Heart 99:1106–1112CrossRefPubMed
9.
Zurück zum Zitat Gabriel J, Klimach S, Lang P, Hildick-Smith D (2015) Should computed tomography angiography supersede invasive coronary angiography for the evaluation of graft patency following coronary artery bypass graft surgery? Interact Cardiovasc Thorac Surg 21(2):231-239CrossRef Gabriel J, Klimach S, Lang P, Hildick-Smith D (2015) Should computed tomography angiography supersede invasive coronary angiography for the evaluation of graft patency following coronary artery bypass graft surgery? Interact Cardiovasc Thorac Surg 21(2):231-239CrossRef
10.
Zurück zum Zitat Sheth T, Chan M, Butler C, Chow B, Tandon V, Nagele P, Mitha A, Mrkobrada M, Szczeklik W, Faridah Y, Biccard B, Stewart LK, Heels-Ansdell D, Devereaux PJ, Coronary Computed Tomographic Angiography and Vascular Events in Noncardiac Surgery Patients Cohort EvaluationStudy Investigators (2015) Prognostic capabilities of coronary computed tomographic angiography before non-cardiac surgery: prospective cohort study. BMJ 350:h1907CrossRefPubMedPubMedCentral Sheth T, Chan M, Butler C, Chow B, Tandon V, Nagele P, Mitha A, Mrkobrada M, Szczeklik W, Faridah Y, Biccard B, Stewart LK, Heels-Ansdell D, Devereaux PJ, Coronary Computed Tomographic Angiography and Vascular Events in Noncardiac Surgery Patients Cohort EvaluationStudy Investigators (2015) Prognostic capabilities of coronary computed tomographic angiography before non-cardiac surgery: prospective cohort study. BMJ 350:h1907CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Pache G, Grohmann J, Bulla S, Arnold R, Stiller B, Schlensak C, Langer M, Blanke P (2011) Prospective electrocardiography-triggered CT angiography of the great thoracic vessels in infants and toddlers with congenital heart disease: feasibility and image quality. Eur J Radiol 80:e440–e445CrossRefPubMed Pache G, Grohmann J, Bulla S, Arnold R, Stiller B, Schlensak C, Langer M, Blanke P (2011) Prospective electrocardiography-triggered CT angiography of the great thoracic vessels in infants and toddlers with congenital heart disease: feasibility and image quality. Eur J Radiol 80:e440–e445CrossRefPubMed
12.
Zurück zum Zitat Ben Saad M, Rohnean A, Sigal-Cinqualbre A, Adler G, Paul JF (2009) Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease. Pediatr Radiol 39:668–676CrossRefPubMed Ben Saad M, Rohnean A, Sigal-Cinqualbre A, Adler G, Paul JF (2009) Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease. Pediatr Radiol 39:668–676CrossRefPubMed
13.
Zurück zum Zitat Ait-Ali L, Andreassi MG, Foffa I, Spadoni I, Vano E, Picano E (2010) Cumulative patient effective dose and acute radiation-induced chromosomal DNA damage in children with congenital heart disease. Heart 96:269–274CrossRefPubMed Ait-Ali L, Andreassi MG, Foffa I, Spadoni I, Vano E, Picano E (2010) Cumulative patient effective dose and acute radiation-induced chromosomal DNA damage in children with congenital heart disease. Heart 96:269–274CrossRefPubMed
14.
Zurück zum Zitat Cheng Z, Wang X, Duan Y, Wu L, Wu D, Chao B, Liu C, Xu Z, Li H, Liang F, Xu J, Chen J (2010) Low-dose prospective ECG-triggered dual-source CT angiography in infants and children with complex congenital heart disease: first experience. Eur Radiol 20:2503–2511CrossRefPubMed Cheng Z, Wang X, Duan Y, Wu L, Wu D, Chao B, Liu C, Xu Z, Li H, Liang F, Xu J, Chen J (2010) Low-dose prospective ECG-triggered dual-source CT angiography in infants and children with complex congenital heart disease: first experience. Eur Radiol 20:2503–2511CrossRefPubMed
15.
Zurück zum Zitat Jin KN, Park EA, Shin CI, Lee W, Chung JW, Park JH (2010) Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart disease: comparison of image quality and radiation dose. Int J Cardiovasc Imaging 26:63–73CrossRefPubMed Jin KN, Park EA, Shin CI, Lee W, Chung JW, Park JH (2010) Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart disease: comparison of image quality and radiation dose. Int J Cardiovasc Imaging 26:63–73CrossRefPubMed
16.
Zurück zum Zitat Wolf F, Leschka S, Loewe C, Homolka P, Plank C, Schernthaner R (2010) Coronary artery stent imaging with 128-slice dual-source CT using high-pitch spiral acquisition in a cardiac phantom: comparison with the sequential and low-pitch spiral mode. Eur Radiol 20:2084–2091CrossRefPubMed Wolf F, Leschka S, Loewe C, Homolka P, Plank C, Schernthaner R (2010) Coronary artery stent imaging with 128-slice dual-source CT using high-pitch spiral acquisition in a cardiac phantom: comparison with the sequential and low-pitch spiral mode. Eur Radiol 20:2084–2091CrossRefPubMed
17.
Zurück zum Zitat Ghoshhajra BB, Lee AM, Engel LC, Celeng C, Kalra MK, Brady TJ (2014) Radiation dose reduction in pediatric cardiac computed tomography: experience from a tertiary medical center. Pediatr Cardiol 35:171–179CrossRefPubMed Ghoshhajra BB, Lee AM, Engel LC, Celeng C, Kalra MK, Brady TJ (2014) Radiation dose reduction in pediatric cardiac computed tomography: experience from a tertiary medical center. Pediatr Cardiol 35:171–179CrossRefPubMed
18.
Zurück zum Zitat Klink T, Müller G, Weil J, Dodge-Khatami A, Adam G, Bley TA (2012) Cardiovascular computed tomography angiography in newborns and infants with suspected congenital heart disease: retrospective evaluation of low-dose scan protocols. Clin Imaging 36:746–753CrossRefPubMed Klink T, Müller G, Weil J, Dodge-Khatami A, Adam G, Bley TA (2012) Cardiovascular computed tomography angiography in newborns and infants with suspected congenital heart disease: retrospective evaluation of low-dose scan protocols. Clin Imaging 36:746–753CrossRefPubMed
19.
Zurück zum Zitat Huang MP, Liang CH, Zhao ZJ, Liu H, Li JL, Zhang JE (2011) Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease. Pediatr Radiol 41:858–866CrossRefPubMed Huang MP, Liang CH, Zhao ZJ, Liu H, Li JL, Zhang JE (2011) Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease. Pediatr Radiol 41:858–866CrossRefPubMed
20.
Zurück zum Zitat Al-Mousily F, Shifrin RY, Fricker FJ, Feranec N, Quinn NS, Chandran A (2011) Use of 320-detector computed tomographic angiography for infants and young children with congenital heart disease. Pediatr Cardiol 32:426–432CrossRefPubMed Al-Mousily F, Shifrin RY, Fricker FJ, Feranec N, Quinn NS, Chandran A (2011) Use of 320-detector computed tomographic angiography for infants and young children with congenital heart disease. Pediatr Cardiol 32:426–432CrossRefPubMed
21.
Zurück zum Zitat Goo HW (2010) State-of-the-art CT imaging techniques for congenital heart disease. Korean J Radiol 11:4–18CrossRefPubMed Goo HW (2010) State-of-the-art CT imaging techniques for congenital heart disease. Korean J Radiol 11:4–18CrossRefPubMed
Metadaten
Titel
Assessment of coronary artery by prospective ECG-triggered 256 multi-slice CT on children with congenital heart disease
verfasst von
Li-Ping Yao
Li Zhang
Hui-Ming Li
Ming Ding
Ling-Wei Yu
Xin Yang
Xiao-Ming Li
Kun Sun
Publikationsdatum
18.05.2017
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 12/2017
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-017-1150-y

Weitere Artikel der Ausgabe 12/2017

The International Journal of Cardiovascular Imaging 12/2017 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.