To develop an algorithm to automatically map CT scan locations of patients onto computational human phantoms to provide with patient-specific organ doses. We developed an algorithm that compares a two-dimensional skeletal mask generated from patient CTs with that of a whole body computational human phantom. The algorithm selected the scan locations showing the highest Dice Similarity Coefficient (DSC) calculated between the skeletal masks of a patient and a phantom. To test the performance of the algorithm, we randomly selected five sets of neck, chest, and abdominal CT images from the National Institutes of Health Clinical Center. We first automatically mapped scan locations of the CT images on a computational human phantom using our algorithm. We had several radiologists to manually map the same CT images on the phantom and compared the results with the automated mapping. Finally, organ doses for automated and manual mapping locations were calculated by an in-house CT dose calculator and compared to each other. The visual comparison showed excellent agreement between manual and automatic mapping locations for neck, chest, and abdomen-pelvis CTs. The difference in mapping locations averaged over the start and end in the five patients was less than 1 cm for all neck, chest, and AP scans: 0.9, 0.7, and 0.9 cm for neck, chest, and AP scans, respectively. Five cases out of ten in the neck scans show zero difference between the average manual and automatic mappings. Average of absolute dose differences between manual and automatic mappings was 2.3, 2.7, and 4.0% for neck, chest, and AP scans, respectively. The automatic mapping algorithm provided accurate scan locations and organ doses compared to manual mapping. The algorithm will be useful in cases requiring patient-specific organ dose for a large number of patients such as patient dose monitoring, clinical trials, and epidemiologic studies.
Literatur
1.
Zurück zum Zitat Miglioretti DL, Johnson E, Williams A, Greenlee RT, Weinmann S, Solberg LI, Feigelson HS, Roblin D, Flynn MJ, Vanneman N, Smith-Bindman R: The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk. JAMA Pediatr 167(8):700–707, 2013CrossRefPubMedPubMedCentral Miglioretti DL, Johnson E, Williams A, Greenlee RT, Weinmann S, Solberg LI, Feigelson HS, Roblin D, Flynn MJ, Vanneman N, Smith-Bindman R: The use of computed tomography in pediatrics and the associated radiation exposure and estimated cancer risk. JAMA Pediatr 167(8):700–707, 2013CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Smith-Bindman R, Miglioretti DL, Johnson E, Lee C, Feigelson HS, Flynn M, Greenlee RT, Kruger RL, Hornbrook MC, Roblin D, Solberg LI, Vanneman N, Weinmann S, Williams AE: Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996-2010. J Am Med Assoc 307(22):2400–2409, 2012. https://doi.org/10.1001/jama.2012.5960 CrossRef Smith-Bindman R, Miglioretti DL, Johnson E, Lee C, Feigelson HS, Flynn M, Greenlee RT, Kruger RL, Hornbrook MC, Roblin D, Solberg LI, Vanneman N, Weinmann S, Williams AE: Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996-2010. J Am Med Assoc 307(22):2400–2409, 2012. https://​doi.​org/​10.​1001/​jama.​2012.​5960 CrossRef
3.
Zurück zum Zitat NCRP: Ionizing radiation exposure of the population of the United States. Bethesda: National Council on Radiation Protection and Measurement, 2009 NCRP: Ionizing radiation exposure of the population of the United States. Bethesda: National Council on Radiation Protection and Measurement, 2009
5.
Zurück zum Zitat McCollough C et al.: The measurement, reporting, and management of radiation dose in CT. Rep AAPM Task Group 23:1–34, 2008 McCollough C et al.: The measurement, reporting, and management of radiation dose in CT. Rep AAPM Task Group 23:1–34, 2008
6.
Zurück zum Zitat AAPM: Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations 2011 AAPM: Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations 2011
11.
Zurück zum Zitat ImPACT, ImPACT CT Patient Dosimetry Calculator, London, UK 2011. ImPACT, ImPACT CT Patient Dosimetry Calculator, London, UK 2011.
14.
Zurück zum Zitat Stamm G, Nagel HD: CT-expo--a novel program for dose evaluation in CT. RoFo 174(12):1570, 2002CrossRefPubMed Stamm G, Nagel HD: CT-expo--a novel program for dose evaluation in CT. RoFo 174(12):1570, 2002CrossRefPubMed
15.
Zurück zum Zitat Cristy M: Mathematical phantoms representing children of various ages for use in estimates of internal dose. Oak Ridge: Oak Ridge National Laboratory, 1980 Cristy M: Mathematical phantoms representing children of various ages for use in estimates of internal dose. Oak Ridge: Oak Ridge National Laboratory, 1980
17.
Zurück zum Zitat Lee C, Lee C, Staton RJ, Hintenlang DE, Arreola MM, Williams JL, Bolch WE: Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination. Med Phys 34(5):1858–1873, 2007CrossRefPubMed Lee C, Lee C, Staton RJ, Hintenlang DE, Arreola MM, Williams JL, Bolch WE: Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination. Med Phys 34(5):1858–1873, 2007CrossRefPubMed
18.
Zurück zum Zitat Lee C, Kim KP, Long D, Fisher R, Tien C, Simon SL, Bouville A, Bolch WE: Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations. Med Phys 38(3):1196–1206, 2011CrossRefPubMedPubMedCentral Lee C, Kim KP, Long D, Fisher R, Tien C, Simon SL, Bouville A, Bolch WE: Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations. Med Phys 38(3):1196–1206, 2011CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Kim KP, Berrington de Gonzalez A, Pearce MS, Salotti JA, Parker L, McHugh K, Craft AW, Lee C: Development of a database of organ doses for paediatric and young adult CT scans in the United Kingdom. Radiat Prot Dosim 150(4):415–426, 2012. https://doi.org/10.1093/rpd/ncr429 CrossRef Kim KP, Berrington de Gonzalez A, Pearce MS, Salotti JA, Parker L, McHugh K, Craft AW, Lee C: Development of a database of organ doses for paediatric and young adult CT scans in the United Kingdom. Radiat Prot Dosim 150(4):415–426, 2012. https://​doi.​org/​10.​1093/​rpd/​ncr429 CrossRef
25.
Zurück zum Zitat G. Kuzmin et al: A novel method to extend a partial-body CT for the reconstruction of dose to organs beyond the scan range, Radiat Res 2018 G. Kuzmin et al: A novel method to extend a partial-body CT for the reconstruction of dose to organs beyond the scan range, Radiat Res 2018
26.
Zurück zum Zitat Lee C, Lodwick D, Hurtado J, Pafundi D, Williams JL, Bolch WE: The UF family of reference hybrid phantoms for computational radiation dosimetry. Phys Med Biol 55(2):339–363, 2010CrossRefPubMed Lee C, Lodwick D, Hurtado J, Pafundi D, Williams JL, Bolch WE: The UF family of reference hybrid phantoms for computational radiation dosimetry. Phys Med Biol 55(2):339–363, 2010CrossRefPubMed
28.
Zurück zum Zitat Geyer AM et al: The UF/NCI family of hybrid computational phantoms representing the current US population of male and female children, adolescents, and adults--application to CT dosimetry. 5225–5242,2014 Geyer AM et al: The UF/NCI family of hybrid computational phantoms representing the current US population of male and female children, adolescents, and adults--application to CT dosimetry. 5225–5242,2014
Metadaten
Titel
Automatic Mapping of CT Scan Locations on Computational Human Phantoms for Organ Dose Estimation
verfasst von
Choonsik Lee
Gleb A. Kuzmin
Jinyong Bae
Jianhua Yao
Elizabeth Mosher
Les R. Folio
Publikationsdatum
05.09.2018
Verlag
Springer International Publishing
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 1/2019
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-018-0119-2

Weitere Artikel der Ausgabe 1/2019

Journal of Digital Imaging 1/2019 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.