Skip to main content
Erschienen in: Neuroradiology 10/2008

01.10.2008 | Interventional Neuroradiology

Brain imaging with a flat detector C-arm

Technique and clinical interest of XperCT

verfasst von: M. Söderman, D. Babic, S. Holmin, T. Andersson

Erschienen in: Neuroradiology | Ausgabe 10/2008

Einloggen, um Zugang zu erhalten

Abstract

Introduction

We present the first clinical results from brain tissue imaging with a novel functionality in the angiography room, the XperCT.

Methods

XperCT is a flat detector C-arm volume acquisition functionality integrated with the angiography equipment. We assessed brain images from 42 patients examined with computed tomography (CT) and XperCT.

Results

In all patients, XperCT had significantly more beam hardening and reconstruction artifacts than CT, in particular in the posterior fossa. Contrast resolution was better on CT images. Hemorrhage, edema, and ventricular size could be assessed with XperCT in all patients, but CT was superior also in this aspect. In four of the last 12 cases, after the latest software upgrade, it was possible to differentiate between supra-tentorial grey and white substance on XperCT images.

Conclusion

CT was superior to XperCT regarding brain soft tissue imaging. However, XperCT could in some cases discriminate between grey and white substance. XperCT is a useful new functionality in interventional neuroradiology. In the clinical setting, it improves patient safety by allowing almost instant access to CT-like brain imaging in the angiography room. It can be life saving in situations where complications during an interventional procedure prompt for immediate action.
Literatur
1.
Zurück zum Zitat Grass M, Koppe R, Klotz E et al (1999) Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data. Comput Med Imaging Graph 23(6):311–321PubMedCrossRef Grass M, Koppe R, Klotz E et al (1999) Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data. Comput Med Imaging Graph 23(6):311–321PubMedCrossRef
2.
Zurück zum Zitat Feldkamp LA, Davis LC, Kress JW (1984) Practical cone-beam algorithm. J Opt Soc Am A 1:612–619 Feldkamp LA, Davis LC, Kress JW (1984) Practical cone-beam algorithm. J Opt Soc Am A 1:612–619
3.
Zurück zum Zitat Benndorf G, Strother CM, Claus B et al (2005) Angiographic CT in cerebrovascular stenting. AJNR Am J Neuroradiol 26(7):1813–1818PubMed Benndorf G, Strother CM, Claus B et al (2005) Angiographic CT in cerebrovascular stenting. AJNR Am J Neuroradiol 26(7):1813–1818PubMed
4.
Zurück zum Zitat Heran NS, Song JK, Namba K, Smith W, Niimi Y, Berenstein A (2006) The utility of DynaCT in neuroendovascular procedures. AJNR Am J Neuroradiol 27(2):330–332PubMed Heran NS, Song JK, Namba K, Smith W, Niimi Y, Berenstein A (2006) The utility of DynaCT in neuroendovascular procedures. AJNR Am J Neuroradiol 27(2):330–332PubMed
5.
Zurück zum Zitat Doelken M, Struffert T, Richter G et al (2008) Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT. Neuroradiology. DOI 10.1007/s00234-008-0372-z Doelken M, Struffert T, Richter G et al (2008) Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT. Neuroradiology. DOI 10.​1007/​s00234-008-0372-z
6.
Zurück zum Zitat Akpek S, Brunner T, Benndorf G, Strother C (2005) Three-dimensional imaging and cone beam volume CT in C-arm angiography with flat panel detector. Diagn Interv Radiol 11(1):10–13PubMed Akpek S, Brunner T, Benndorf G, Strother C (2005) Three-dimensional imaging and cone beam volume CT in C-arm angiography with flat panel detector. Diagn Interv Radiol 11(1):10–13PubMed
7.
Zurück zum Zitat White PM, Gilmour JN, Weir NW, Innes B, Sellar RJ (2007) AngioCT in the management of neurointerventional patients: a prospective, consecutive series with associated dosimetry and resolution data. Neuroradiology 50(4):321–330PubMedCrossRef White PM, Gilmour JN, Weir NW, Innes B, Sellar RJ (2007) AngioCT in the management of neurointerventional patients: a prospective, consecutive series with associated dosimetry and resolution data. Neuroradiology 50(4):321–330PubMedCrossRef
8.
Zurück zum Zitat Kalender WA, Kyriakou Y (2007) Flat-detector computed tomography (FD-CT). Eur Radiol 17(11):2767–2779PubMedCrossRef Kalender WA, Kyriakou Y (2007) Flat-detector computed tomography (FD-CT). Eur Radiol 17(11):2767–2779PubMedCrossRef
9.
Zurück zum Zitat Obenauer S, Dullin C, Alves F, Missbach-Guentner J, Grabbe E, Heuser M (2007) Flat-panel-detector-based volumetric CT: performance evaluation of imaging for skeletal structures of small animals in comparison to multislice CT. Clin Imaging 31(1):18–22PubMedCrossRef Obenauer S, Dullin C, Alves F, Missbach-Guentner J, Grabbe E, Heuser M (2007) Flat-panel-detector-based volumetric CT: performance evaluation of imaging for skeletal structures of small animals in comparison to multislice CT. Clin Imaging 31(1):18–22PubMedCrossRef
10.
Zurück zum Zitat Mahnken AH, Grasruck M, Schmidt B, Gunther RW, Wildberger JE (2008) Flat panel computed tomography for non-invasive flow measurement: initial results in in-vitro studies. Eur Radiol 18(4):747–752PubMedCrossRef Mahnken AH, Grasruck M, Schmidt B, Gunther RW, Wildberger JE (2008) Flat panel computed tomography for non-invasive flow measurement: initial results in in-vitro studies. Eur Radiol 18(4):747–752PubMedCrossRef
11.
Zurück zum Zitat Hirota S, Nakao N, Yamamoto S et al (2006) Cone-beam CT with flat-panel-detector digital angiography system: early experience in abdominal interventional procedures. Cardiovasc Interv Radiol 29(6):1034–1038CrossRef Hirota S, Nakao N, Yamamoto S et al (2006) Cone-beam CT with flat-panel-detector digital angiography system: early experience in abdominal interventional procedures. Cardiovasc Interv Radiol 29(6):1034–1038CrossRef
12.
Zurück zum Zitat Kakeda S, Korogi Y, Hatakeyama Y et al (2008) The usefulness of three-dimensional angiography with a flat panel detector of direct conversion type in a transcatheter arterial chemoembolization procedure for hepatocellular carcinoma: initial experience. Cardiovasc Interv Radiol 31(2):281–288CrossRef Kakeda S, Korogi Y, Hatakeyama Y et al (2008) The usefulness of three-dimensional angiography with a flat panel detector of direct conversion type in a transcatheter arterial chemoembolization procedure for hepatocellular carcinoma: initial experience. Cardiovasc Interv Radiol 31(2):281–288CrossRef
13.
Zurück zum Zitat Kakeda S, Korogi Y, Ohnari N et al (2007) Usefulness of cone-beam volume CT with flat panel detectors in conjunction with catheter angiography for transcatheter arterial embolization. J Vasc Interv Radiol 18(12):1508–1516PubMedCrossRef Kakeda S, Korogi Y, Ohnari N et al (2007) Usefulness of cone-beam volume CT with flat panel detectors in conjunction with catheter angiography for transcatheter arterial embolization. J Vasc Interv Radiol 18(12):1508–1516PubMedCrossRef
14.
Zurück zum Zitat Virmani S, Ryu RK, Sato KT et al (2007) Effect of C-arm angiographic CT on transcatheter arterial chemoembolization of liver tumors. J Vasc Interv Radiol 18(10):1305–1309PubMedCrossRef Virmani S, Ryu RK, Sato KT et al (2007) Effect of C-arm angiographic CT on transcatheter arterial chemoembolization of liver tumors. J Vasc Interv Radiol 18(10):1305–1309PubMedCrossRef
15.
Zurück zum Zitat Honey OB, Scarfe WC, Hilgers MJ et al (2007) Accuracy of cone-beam computed tomography imaging of the temporomandibular joint: comparisons with panoramic radiology and linear tomography. Am J Orthod Dentofacial Orthop 132(4):429–438PubMedCrossRef Honey OB, Scarfe WC, Hilgers MJ et al (2007) Accuracy of cone-beam computed tomography imaging of the temporomandibular joint: comparisons with panoramic radiology and linear tomography. Am J Orthod Dentofacial Orthop 132(4):429–438PubMedCrossRef
16.
Zurück zum Zitat Engelhorn T, Rennert J, Richter G, Struffert T, Ganslandt O, Doerfler A (2007) Myelography using flat panel volumetric computed tomography: a comparative study in patients with lumbar spinal stenosis. Spine 32(18):E523–E527PubMedCrossRef Engelhorn T, Rennert J, Richter G, Struffert T, Ganslandt O, Doerfler A (2007) Myelography using flat panel volumetric computed tomography: a comparative study in patients with lumbar spinal stenosis. Spine 32(18):E523–E527PubMedCrossRef
17.
Zurück zum Zitat Buhk JH, Elolf E, Jacob D, Rustenbeck HH, Mohr A, Knauth M (2008) A comparison of angiographic CT and multisection CT in lumbar myelographic imaging. AJNR Am J Neuroradiol 29(3):442–446PubMedCrossRef Buhk JH, Elolf E, Jacob D, Rustenbeck HH, Mohr A, Knauth M (2008) A comparison of angiographic CT and multisection CT in lumbar myelographic imaging. AJNR Am J Neuroradiol 29(3):442–446PubMedCrossRef
Metadaten
Titel
Brain imaging with a flat detector C-arm
Technique and clinical interest of XperCT
verfasst von
M. Söderman
D. Babic
S. Holmin
T. Andersson
Publikationsdatum
01.10.2008
Verlag
Springer-Verlag
Erschienen in
Neuroradiology / Ausgabe 10/2008
Print ISSN: 0028-3940
Elektronische ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-008-0419-1

Weitere Artikel der Ausgabe 10/2008

Neuroradiology 10/2008 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Frühe Alzheimertherapie lohnt sich

25.04.2024 AAN-Jahrestagung 2024 Nachrichten

Ist die Tau-Last noch gering, scheint der Vorteil von Lecanemab besonders groß zu sein. Und beginnen Erkrankte verzögert mit der Behandlung, erreichen sie nicht mehr die kognitive Leistung wie bei einem früheren Start. Darauf deuten neue Analysen der Phase-3-Studie Clarity AD.

Viel Bewegung in der Parkinsonforschung

25.04.2024 Parkinson-Krankheit Nachrichten

Neue arznei- und zellbasierte Ansätze, Frühdiagnose mit Bewegungssensoren, Rückenmarkstimulation gegen Gehblockaden – in der Parkinsonforschung tut sich einiges. Auf dem Deutschen Parkinsonkongress ging es auch viel um technische Innovationen.

Demenzkranke durch Antipsychotika vielfach gefährdet

23.04.2024 Demenz Nachrichten

Wenn Demenzkranke aufgrund von Symptomen wie Agitation oder Aggressivität mit Antipsychotika behandelt werden, sind damit offenbar noch mehr Risiken verbunden als bislang angenommen.

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.