Skip to main content
Erschienen in: Journal of Digital Imaging 6/2011

01.12.2011

CAUDLES-EF: Carotid Automated Ultrasound Double Line Extraction System Using Edge Flow

verfasst von: Filippo Molinari, Kristen M. Meiburger, Guang Zeng, Andrew Nicolaides, Jasjit S. Suri

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 6/2011

Einloggen, um Zugang zu erhalten

Abstract

The evaluation of the carotid artery wall is essential for the diagnosis of cardiovascular pathologies or for the assessment of a patient’s cardiovascular risk. This paper presents a completely user-independent algorithm, which automatically extracts the far double line (lumen–intima and media–adventitia) in the carotid artery using an Edge Flow technique based on directional probability maps using the attributes of intensity and texture. Specifically, the algorithm traces the boundaries between the lumen and intima layer (line one) and between the media and adventitia layer (line two). The Carotid Automated Ultrasound Double Line Extraction System based on Edge-Flow (CAUDLES-EF) is characterized and validated by comparing the output of the algorithm with the manual tracing boundaries carried out by three experts. We also benchmark our new technique with the two other completely automatic techniques (CALEXia and CULEXsa) we previously published. Our multi-institutional database consisted of 300 longitudinal B-mode carotid images with normal and pathologic arteries. We compared our current new method with previous methods, and showed the mean and standard deviation for the three methods: CALEXia, CULEXsa, and CAUDLES-EF as 0.134 ± 0.088, 0.074 ± 0.092, and 0.043 ± 0.097 mm, respectively. Our IMT was slightly underestimated with respect to the ground truth IMT, but showed a uniform behavior over the entire database. Regarding the Figure of Merit (FoM), CALEXia and CULEXsa showed the values of 84.7% and 91.5%, respectively, while our new approach, CAUDLES-EF, performed the best at 94.8%, showing a good improvement compared to previous methods.
Literatur
1.
Zurück zum Zitat Amato M, et al: Carotid intima-media thickness by B-mode ultrasound as surrogate of coronary atherosclerosis: correlation with quantitative coronary angiography and coronary intravascular ultrasound findings. European Heart Journal 28(17):2094–101, 2007PubMedCrossRef Amato M, et al: Carotid intima-media thickness by B-mode ultrasound as surrogate of coronary atherosclerosis: correlation with quantitative coronary angiography and coronary intravascular ultrasound findings. European Heart Journal 28(17):2094–101, 2007PubMedCrossRef
2.
Zurück zum Zitat Rosvall M, et al: Incidence of stroke is related to carotid IMT even in the absence of plaque. Atherosclerosis 179(2):325–31, 2005PubMedCrossRef Rosvall M, et al: Incidence of stroke is related to carotid IMT even in the absence of plaque. Atherosclerosis 179(2):325–31, 2005PubMedCrossRef
3.
Zurück zum Zitat Saba, L. and G. Mallarini, A comparison between NASCET and ECST methods in the study of carotids Evaluation using Multi-Detector-Row CT angiography. Eur J Radiol, 2009 Saba, L. and G. Mallarini, A comparison between NASCET and ECST methods in the study of carotids Evaluation using Multi-Detector-Row CT angiography. Eur J Radiol, 2009
4.
Zurück zum Zitat Touboul PJ, et al: Mannheim carotid intima-media thickness consensus (2004–2006). An update on behalf of the Advisory Board of the 3 rd and 4th Watching the Risk Symposium, 13th and 15th European Stroke Conferences, Mannheim, Germany, 2004, and Brussels, Belgium, 2006. Cerebrovasc Dis 23(1):75–80, 2007PubMedCrossRef Touboul PJ, et al: Mannheim carotid intima-media thickness consensus (2004–2006). An update on behalf of the Advisory Board of the 3 rd and 4th Watching the Risk Symposium, 13th and 15th European Stroke Conferences, Mannheim, Germany, 2004, and Brussels, Belgium, 2006. Cerebrovasc Dis 23(1):75–80, 2007PubMedCrossRef
5.
Zurück zum Zitat Touboul PJ, et al: Mannheim intima-media thickness consensus. Cerebrovasc Dis 18(4):346–9, 2004PubMedCrossRef Touboul PJ, et al: Mannheim intima-media thickness consensus. Cerebrovasc Dis 18(4):346–9, 2004PubMedCrossRef
6.
Zurück zum Zitat Delsanto S, et al: CULEX-completely user-independent layers extraction: ultrasonic carotid artery images segmentation. Conf Proc IEEE Eng Med Biol Soc 6:6468–71, 2005PubMed Delsanto S, et al: CULEX-completely user-independent layers extraction: ultrasonic carotid artery images segmentation. Conf Proc IEEE Eng Med Biol Soc 6:6468–71, 2005PubMed
7.
Zurück zum Zitat Delsanto S, et al: Characterization of a Completely User-Independent Algorithm for Carotid Artery Segmentation in 2-D Ultrasound Images. Instrumentation and Measurement, IEEE Transactions on 56(4):1265–1274, 2007CrossRef Delsanto S, et al: Characterization of a Completely User-Independent Algorithm for Carotid Artery Segmentation in 2-D Ultrasound Images. Instrumentation and Measurement, IEEE Transactions on 56(4):1265–1274, 2007CrossRef
8.
Zurück zum Zitat Molinari F, et al: Automatic computer-based tracings (ACT) in longitudinal 2-D ultrasound images using different scanners. Journal of Mechanics in Medicine and Biology 9(4):481–505, 2009CrossRef Molinari F, et al: Automatic computer-based tracings (ACT) in longitudinal 2-D ultrasound images using different scanners. Journal of Mechanics in Medicine and Biology 9(4):481–505, 2009CrossRef
9.
Zurück zum Zitat Molinari F, Zeng G, Suri JS: An integrated approach to computer- based automated tracing and its validation for 200 common carotid arterial wall ultrasound images: A new technique. J Ultras Med 29:399–418, 2010 Molinari F, Zeng G, Suri JS: An integrated approach to computer- based automated tracing and its validation for 200 common carotid arterial wall ultrasound images: A new technique. J Ultras Med 29:399–418, 2010
10.
Zurück zum Zitat Molinari F, Zeng G, Suri JS: Intima-media thickness: setting a standard for completely automated method for ultrasound. IEEE Transaction on Ultrasonics Ferroelectrics and Frequency Control 57(5):1112–1124, 2010CrossRef Molinari F, Zeng G, Suri JS: Intima-media thickness: setting a standard for completely automated method for ultrasound. IEEE Transaction on Ultrasonics Ferroelectrics and Frequency Control 57(5):1112–1124, 2010CrossRef
11.
Zurück zum Zitat Zhen, Y., et al. Four image interpolation techniques for ultrasound breast phantom data acquired using Fischer's full field digital mammography and ultrasound system (FFDMUS): a comparative approach. in Image Processing, 2005. ICIP 2005. IEEE International Conference on. 2005 Zhen, Y., et al. Four image interpolation techniques for ultrasound breast phantom data acquired using Fischer's full field digital mammography and ultrasound system (FFDMUS): a comparative approach. in Image Processing, 2005. ICIP 2005. IEEE International Conference on. 2005
12.
Zurück zum Zitat Loizou CP, et al: Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery. Ultrasonics, Ferroelectrics and Frequency Control, IEEE Transactions on 52(10):1653–1669, 2005CrossRef Loizou CP, et al: Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery. Ultrasonics, Ferroelectrics and Frequency Control, IEEE Transactions on 52(10):1653–1669, 2005CrossRef
13.
Zurück zum Zitat Loizou CP, et al: Quality evaluation of ultrasound imaging in the carotid artery based on normalization and speckle reduction filtering. Med Biol Eng Comput 44(5):414–26, 2006PubMedCrossRef Loizou CP, et al: Quality evaluation of ultrasound imaging in the carotid artery based on normalization and speckle reduction filtering. Med Biol Eng Comput 44(5):414–26, 2006PubMedCrossRef
14.
Zurück zum Zitat Ma, W.Y. and B.S. Manjunath. Edge Flow: A Framework of Boundary Detection and Image Segmentation. in Computer Society Conference on Computer Vision and Pattern Recognition. 1997. San Juan Ma, W.Y. and B.S. Manjunath. Edge Flow: A Framework of Boundary Detection and Image Segmentation. in Computer Society Conference on Computer Vision and Pattern Recognition. 1997. San Juan
15.
Zurück zum Zitat Suri JS, Haralick RM, Sheehan FH: Greedy algorithm for error correction in automatically produced boundaries from low contrast ventriculograms. Pattern Analysis and Applications 3(1):39–60, 2000CrossRef Suri JS, Haralick RM, Sheehan FH: Greedy algorithm for error correction in automatically produced boundaries from low contrast ventriculograms. Pattern Analysis and Applications 3(1):39–60, 2000CrossRef
Metadaten
Titel
CAUDLES-EF: Carotid Automated Ultrasound Double Line Extraction System Using Edge Flow
verfasst von
Filippo Molinari
Kristen M. Meiburger
Guang Zeng
Andrew Nicolaides
Jasjit S. Suri
Publikationsdatum
01.12.2011
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 6/2011
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-011-9375-0

Weitere Artikel der Ausgabe 6/2011

Journal of Digital Imaging 6/2011 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.