Skip to main content
Erschienen in: International Ophthalmology 4/2010

01.08.2010 | Original Paper

Changes in intraocular pressure, and corneal and retinal nerve fiber layer thickness during hemodialysis

verfasst von: Umut Asli Dinc, Sengül Ozdek, Zeynep Aktas, Galip Guz, Merih Onol

Erschienen in: International Ophthalmology | Ausgabe 4/2010

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study is to evaluate the changes in intraocular pressure (IOP), central corneal thickness (CCT), and retinal nerve fiber layer thickness (RNFLT) in patients with chronic renal failure undergoing hemodialysis (HD). A complete ophthalmological examination together with IOP, CCT, and RNFLT measurements were performed for each patient both before and after HD sessions. RNFLT parameters were detected by scanning laser polarimeter. Total body weight and serum osmolality were also measured. Only the left eyes were recruited for statistical analysis. Thirty-three eyes of 33 patients were enrolled in the study. Mean IOP decreased from 14.7 ± 3.1 to 13.4 ± 2.4 mmHg after HD (paired t test, P = 0.005). Mean CCT also decreased significantly after HD, from 556.5 ± 33.5 to 550.2 ± 34.6 μm (paired t test, P = 0.002). CCT change in the left eyes was found to be correlated with total body volume loss (Pearson correlation test, R = 0.391 and P = 0.030). Considering RNFLT parameters before and after HD, no significant alterations were detected by scanning laser polarimeter (paired t test, P > 0.05). We conclude that IOP may decrease to some extent after HD. CCT may be affected by fluid loss after HD sessions, with a resultant decrease in corneal thickness. In patients with chronic renal failure undergoing HD, RNFLT parameters can be measured as in healthy individuals. Underestimation of intraocular pressure values after HD sessions should be taken into account, especially in patients with chronic renal failure.
Literatur
1.
Zurück zum Zitat Tomazzoli L, De Natale R, Lupo A, Parolini B (2000) Visual acuity disturbances in chronic renal failure. Ophthalmologica 214:403–405CrossRefPubMed Tomazzoli L, De Natale R, Lupo A, Parolini B (2000) Visual acuity disturbances in chronic renal failure. Ophthalmologica 214:403–405CrossRefPubMed
2.
Zurück zum Zitat Diaz-Couchoud P, Bordas FD, Garcia JRF, Camps EM, Carceller A (2001) Corneal disease in patients with chronic renal insufficiency undergoing hemodialysis. Cornea 20(7):695–702CrossRefPubMed Diaz-Couchoud P, Bordas FD, Garcia JRF, Camps EM, Carceller A (2001) Corneal disease in patients with chronic renal insufficiency undergoing hemodialysis. Cornea 20(7):695–702CrossRefPubMed
3.
Zurück zum Zitat Klaassen-Broekema N, Van Bijsterveld OP (1992) Red eyes in renal failure. Br J Ophthalmol 76:268–271CrossRefPubMed Klaassen-Broekema N, Van Bijsterveld OP (1992) Red eyes in renal failure. Br J Ophthalmol 76:268–271CrossRefPubMed
4.
Zurück zum Zitat Cecchin E, De Marchi S, Teiso F (1986) Intraocular pressure and hemodialysis. Nephron 43:73–74CrossRefPubMed Cecchin E, De Marchi S, Teiso F (1986) Intraocular pressure and hemodialysis. Nephron 43:73–74CrossRefPubMed
5.
Zurück zum Zitat Aktas Z, Özdek S, Dinc UA, Akyurek N, Atalay V, Guz G, Hasanreisoglu B (2007) Alterations in ocular surface and corneal thickness in relation to metabolic control in patients with chronic renal failure. Nephrology 12(4):380–385CrossRefPubMed Aktas Z, Özdek S, Dinc UA, Akyurek N, Atalay V, Guz G, Hasanreisoglu B (2007) Alterations in ocular surface and corneal thickness in relation to metabolic control in patients with chronic renal failure. Nephrology 12(4):380–385CrossRefPubMed
6.
Zurück zum Zitat Sitprija V, Holmes JH, Ellis PP (1964) Changes in intraocular pressure during hemodialysis. Invest Ophthalmol Vis Sci 3:273–283 Sitprija V, Holmes JH, Ellis PP (1964) Changes in intraocular pressure during hemodialysis. Invest Ophthalmol Vis Sci 3:273–283
7.
Zurück zum Zitat Levy J, Tovbin D, Lifshitz T, Ziotnik M, Tessler Z (2005) Intraocular pressure during haemodialysis: a review. Eye 19:1249–1256CrossRefPubMed Levy J, Tovbin D, Lifshitz T, Ziotnik M, Tessler Z (2005) Intraocular pressure during haemodialysis: a review. Eye 19:1249–1256CrossRefPubMed
8.
Zurück zum Zitat Broekema N, Van Bijsterveld OP, De Bos Kuil RJC (1988) Intraocular pressure during hemodialysis. Ophthalmologica 197:60–64CrossRefPubMed Broekema N, Van Bijsterveld OP, De Bos Kuil RJC (1988) Intraocular pressure during hemodialysis. Ophthalmologica 197:60–64CrossRefPubMed
9.
Zurück zum Zitat Damji KF, Munger R (2000) Influence of central corneal thickness on applanation intraocular pressure. J Glaucoma 9:205–207PubMed Damji KF, Munger R (2000) Influence of central corneal thickness on applanation intraocular pressure. J Glaucoma 9:205–207PubMed
10.
Zurück zum Zitat Quigley HA, Miller NR, George T (1980) Clinical evaluation of nerve fiber layer atrophy as an indicator of glaucomatous optic nerve damage. Arch Ophthalmol 98:1564–1571PubMed Quigley HA, Miller NR, George T (1980) Clinical evaluation of nerve fiber layer atrophy as an indicator of glaucomatous optic nerve damage. Arch Ophthalmol 98:1564–1571PubMed
11.
Zurück zum Zitat Doughty MJ, Zaman ML (2000) Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 44:367–408CrossRefPubMed Doughty MJ, Zaman ML (2000) Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 44:367–408CrossRefPubMed
12.
Zurück zum Zitat Shah S, Chatterjee A, Mathai M (1999) Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic. Ophthalmology 106:2154–2160CrossRefPubMed Shah S, Chatterjee A, Mathai M (1999) Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic. Ophthalmology 106:2154–2160CrossRefPubMed
13.
Zurück zum Zitat Stodtmeister R (1998) Applanation tonometry and correction according to corneal thickness. Acta Ophthalmol Scan 76:319–324CrossRef Stodtmeister R (1998) Applanation tonometry and correction according to corneal thickness. Acta Ophthalmol Scan 76:319–324CrossRef
14.
Zurück zum Zitat Tovbin D, Belfair N, Shapira S, Rosenthal G, Friger M, Feldman L, Lifshitz T, Tessler Z (2002) High postdialysis urea rebound can predict intradialytic increase in intraocular pressure in dialysis patients with lowered intradialytic hemoconcentration. Nephron 90:181–187CrossRefPubMed Tovbin D, Belfair N, Shapira S, Rosenthal G, Friger M, Feldman L, Lifshitz T, Tessler Z (2002) High postdialysis urea rebound can predict intradialytic increase in intraocular pressure in dialysis patients with lowered intradialytic hemoconcentration. Nephron 90:181–187CrossRefPubMed
15.
Zurück zum Zitat Yoon YH, Sohn JH, Lee SE, Lee YB, Kim JY, Kook MS (2000) Increases in intraocular pressure during hemodialysis in eyes during early postvitrectomy period. Ophthalmic Surg Lasers 31:467–473PubMed Yoon YH, Sohn JH, Lee SE, Lee YB, Kim JY, Kook MS (2000) Increases in intraocular pressure during hemodialysis in eyes during early postvitrectomy period. Ophthalmic Surg Lasers 31:467–473PubMed
16.
Zurück zum Zitat Minguela I, Andonegui J, Aurrekoetxea B, De Gauna RR (2000) Prevention of intraocular pressure elevations during hemodialysis. Am J Kidney Dis 36(1):197–198PubMed Minguela I, Andonegui J, Aurrekoetxea B, De Gauna RR (2000) Prevention of intraocular pressure elevations during hemodialysis. Am J Kidney Dis 36(1):197–198PubMed
17.
Zurück zum Zitat Leiba H, Oliver M, Shimshoni M, Bar-Khayim Y (1990) Intraocular pressure fluctuations during regular hemodialysis and ultrafiltration. Acta Ophthalmol 68:32–322CrossRef Leiba H, Oliver M, Shimshoni M, Bar-Khayim Y (1990) Intraocular pressure fluctuations during regular hemodialysis and ultrafiltration. Acta Ophthalmol 68:32–322CrossRef
18.
Zurück zum Zitat Gafter U, Pinkas M, Hirsch J, Savir LH (1985) Intraocular pressure in uremic patients on chronic hemodialysis. Nephron 40:74–75CrossRefPubMed Gafter U, Pinkas M, Hirsch J, Savir LH (1985) Intraocular pressure in uremic patients on chronic hemodialysis. Nephron 40:74–75CrossRefPubMed
19.
Zurück zum Zitat Tokuyama T, Ikeda T, Sato K (1998) Effect of plasma colloid osmotic pressure on intraocular pressure during haemodialysis. Br J Ophthalmol 82:751–753CrossRefPubMed Tokuyama T, Ikeda T, Sato K (1998) Effect of plasma colloid osmotic pressure on intraocular pressure during haemodialysis. Br J Ophthalmol 82:751–753CrossRefPubMed
20.
Zurück zum Zitat Gutmann SM, Vaziri ND (1984) Effect of hemodialysis on intraocular pressure. Artif Organs 8:62–65CrossRefPubMed Gutmann SM, Vaziri ND (1984) Effect of hemodialysis on intraocular pressure. Artif Organs 8:62–65CrossRefPubMed
21.
Zurück zum Zitat Rever B, Fox L, Bar-Khayim Y, Nissenson A (1981) Adverse ocular effects of acetate hemodialysis. Kidney Int 19:157 Rever B, Fox L, Bar-Khayim Y, Nissenson A (1981) Adverse ocular effects of acetate hemodialysis. Kidney Int 19:157
22.
Zurück zum Zitat De Marchi S, Cechin Etesio F (1989) Intraocular pressure changes during hemodialysis: prevention of excessive dialytic rise and development of severe metabolic acidosis following acetazolamide therapy. Ren Fail 11:117–124CrossRefPubMed De Marchi S, Cechin Etesio F (1989) Intraocular pressure changes during hemodialysis: prevention of excessive dialytic rise and development of severe metabolic acidosis following acetazolamide therapy. Ren Fail 11:117–124CrossRefPubMed
23.
Zurück zum Zitat Hojs R, Pahor D (1997) Intraocular pressure in chronic renal failure patients treated with maintenance hemodialysis. Ophthalmologica 211:325–326CrossRefPubMed Hojs R, Pahor D (1997) Intraocular pressure in chronic renal failure patients treated with maintenance hemodialysis. Ophthalmologica 211:325–326CrossRefPubMed
24.
Zurück zum Zitat Costagliola C, Mastropasqua L (1991) The influence of hemodialysis on intraocular pressure. III. Aqueous humor dynamics and tissue hydration. Ann Ophthlamol 23:31–34 Costagliola C, Mastropasqua L (1991) The influence of hemodialysis on intraocular pressure. III. Aqueous humor dynamics and tissue hydration. Ann Ophthlamol 23:31–34
25.
Zurück zum Zitat Thorburn W (1978) The accuracy of clinical applanation tonometry. Acta Ophthalmol (Copenh) 56:1–5CrossRef Thorburn W (1978) The accuracy of clinical applanation tonometry. Acta Ophthalmol (Copenh) 56:1–5CrossRef
26.
Zurück zum Zitat Dielemans I, Vingerling JR, Hofman A, Grobbee DE, de Jong PT (1994) Reliability of intraocular pressure measurement with the Goldman applanation tonometer in epidemiological studies. Graefes Arch Clin Exp Ophthalmol 232:141–144CrossRefPubMed Dielemans I, Vingerling JR, Hofman A, Grobbee DE, de Jong PT (1994) Reliability of intraocular pressure measurement with the Goldman applanation tonometer in epidemiological studies. Graefes Arch Clin Exp Ophthalmol 232:141–144CrossRefPubMed
27.
Zurück zum Zitat Pelit A, Zümrütdal A, Akova Y (2003) The effect of hemodialysis on visual fields test in patients with chronic renal failure. Curr Eye Res 26:303–306CrossRefPubMed Pelit A, Zümrütdal A, Akova Y (2003) The effect of hemodialysis on visual fields test in patients with chronic renal failure. Curr Eye Res 26:303–306CrossRefPubMed
Metadaten
Titel
Changes in intraocular pressure, and corneal and retinal nerve fiber layer thickness during hemodialysis
verfasst von
Umut Asli Dinc
Sengül Ozdek
Zeynep Aktas
Galip Guz
Merih Onol
Publikationsdatum
01.08.2010
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 4/2010
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-009-9339-2

Weitere Artikel der Ausgabe 4/2010

International Ophthalmology 4/2010 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.