Clinical application of a pedicle nail system with polymethylmethacrylate for osteoporotic vertebral fracture

verfasst von: Keiya Yamana, Masato Tanaka, Yoshihisa Sugimoto, Tomoyuki Takigawa, Toshifumi Ozaki, Hitoshi Konishi

Erschienen in: European Spine Journal | Ausgabe 10/2010

Einloggen, um Zugang zu erhalten

Abstract

The instrumentation of the osteoporotic spine may sometimes result in failure due to the loosening or pullout of the conventional pedicle screw. Moreover, augmentation of screws with polymethylmethacrylate (PMMA) has risks of complications. We developed a new and original pedicle nail system with PMMA for osteoporotic vertebral fractures. A clinical evaluation of this novel pedicle nail system utilized in patients with an osteoporotic vertebral collapse was performed to determine the effectiveness and safety of this technique. Thirty-four elderly patients who suffered from osteoporotic compression fractures were treated by posterolateral fusion using the pedicle nail system. The mean follow-up period was 37 months. Of the 25 patients with neurological symptoms, two patients improved two stages at the Frankel level. Fifteen patients improved one stage at the Frankel level, and eight other patients improved, however, their improvement did not exceed a Frankel level. Nine cases with neuralgia symptoms improved from 4.4 to 2.2 points on average on the Denis pain scale (p < 0.01). The fusion rate was 94% as determined by X-rays of flexion and extension, and the correction of the compression fracture site was maintained well. A pedicle nail system stabilizes the spinal column with osteoporosis and reduces the instrumentation failure. The technique for the insertion of the pedicle nail reduces complication from cement augmentation. The authors speculate that the strategy using the pedicle nail system for osteoporotic spine may be effective and safe when the surgery is performed through a posterior approach.
Fußnoten
1
The pedicle nail has been called novel pedicle screw (NPS) in other research [23]. We are using pedicle nail in this report to alleviate any confusion between the pedicle nail or NPS and conventional pedicle screws.
 
Literatur
1.
Zurück zum Zitat Chiras J, Depriester C, Weill A, Sola-Martinez MT, Deramond H (1997) Percutaneous vertebral surgery. Technics and indications. J Neuroradiol 24:45–59PubMed Chiras J, Depriester C, Weill A, Sola-Martinez MT, Deramond H (1997) Percutaneous vertebral surgery. Technics and indications. J Neuroradiol 24:45–59PubMed
3.
Zurück zum Zitat Cortet B, Cotten A, Boutry N, Flipo RM, Duquesnoy B, Chastanet P, Delcambre B (1999) Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: an open prospective study. J Rheumatol 26:2222–2228PubMed Cortet B, Cotten A, Boutry N, Flipo RM, Duquesnoy B, Chastanet P, Delcambre B (1999) Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: an open prospective study. J Rheumatol 26:2222–2228PubMed
4.
Zurück zum Zitat Denis F, Armstrong GW, Searls K, Matta L (1984) Acute thoracolumbar burst fractures in the absence of neurologic deficit. A comparison between operative and nonoperative treatment. Clin Orthop Relat Res 189:142–149PubMed Denis F, Armstrong GW, Searls K, Matta L (1984) Acute thoracolumbar burst fractures in the absence of neurologic deficit. A comparison between operative and nonoperative treatment. Clin Orthop Relat Res 189:142–149PubMed
6.
Zurück zum Zitat Frankel BM, Jones T, Wang C (2007) Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery 61:531–537 (discussion 537–538). doi:10.1227/01.NEU.0000290899.15567.68 Frankel BM, Jones T, Wang C (2007) Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation. Neurosurgery 61:531–537 (discussion 537–538). doi:10.​1227/​01.​NEU.​0000290899.​15567.​68
7.
8.
Zurück zum Zitat Gaughen JR Jr, Jensen ME, Schweickert PA, Kaufmann TJ, Marx WF, Kallmes DF (2002) Relevance of antecedent venography in percutaneous vertebroplasty for the treatment of osteoporotic compression fractures. AJNR Am J Neuroradiol 23:594–600PubMed Gaughen JR Jr, Jensen ME, Schweickert PA, Kaufmann TJ, Marx WF, Kallmes DF (2002) Relevance of antecedent venography in percutaneous vertebroplasty for the treatment of osteoporotic compression fractures. AJNR Am J Neuroradiol 23:594–600PubMed
9.
Zurück zum Zitat Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS 3rd, Cook SD (1994) Effects of bone mineral density on pedicle screw fixation. Spine 19:2415–2420CrossRefPubMed Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS 3rd, Cook SD (1994) Effects of bone mineral density on pedicle screw fixation. Spine 19:2415–2420CrossRefPubMed
10.
Zurück zum Zitat Jensen ME, Evans AJ, Mathis JM, Kallmes DF, Cloft HJ, Dion JE (1997) Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects. AJNR Am J Neuroradiol 18:1897–1904PubMed Jensen ME, Evans AJ, Mathis JM, Kallmes DF, Cloft HJ, Dion JE (1997) Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects. AJNR Am J Neuroradiol 18:1897–1904PubMed
11.
Zurück zum Zitat Kaneda K, Asano S, Hashimoto T, Satoh S, Fujiya M (1992) The treatment of osteoporotic-posttraumatic vertebral collapse using the Kaneda device and a bioactive ceramic vertebral prosthesis. Spine 17:S295–S303CrossRefPubMed Kaneda K, Asano S, Hashimoto T, Satoh S, Fujiya M (1992) The treatment of osteoporotic-posttraumatic vertebral collapse using the Kaneda device and a bioactive ceramic vertebral prosthesis. Spine 17:S295–S303CrossRefPubMed
12.
Zurück zum Zitat Kaplan PA, Orton DF, Asleson RJ (1987) Osteoporosis with vertebral compression fractures, retropulsed fragments, and neurologic compromise. Radiology 165:533–535PubMed Kaplan PA, Orton DF, Asleson RJ (1987) Osteoporosis with vertebral compression fractures, retropulsed fragments, and neurologic compromise. Radiology 165:533–535PubMed
13.
Zurück zum Zitat Korovessis P, Maraziotis T, Piperos G, Spyropoulos P (1994) Spontaneous burst fracture of the thoracolumbar spine in osteoporosis associated with neurological impairment: a report of seven cases and review of the literature. Eur Spine J 3:286–288CrossRefPubMed Korovessis P, Maraziotis T, Piperos G, Spyropoulos P (1994) Spontaneous burst fracture of the thoracolumbar spine in osteoporosis associated with neurological impairment: a report of seven cases and review of the literature. Eur Spine J 3:286–288CrossRefPubMed
14.
Zurück zum Zitat Loeffel M, Ferguson SJ, Nolte LP, Kowal JH (2008) Vertebroplasty: experimental characterization of polymethylmethacrylate bone cement spreading as a function of viscosity, bone porosity, and flow rate. Spine 33:1352-1359. doi:10.1097/BRS.0b013e3181732aa9 Loeffel M, Ferguson SJ, Nolte LP, Kowal JH (2008) Vertebroplasty: experimental characterization of polymethylmethacrylate bone cement spreading as a function of viscosity, bone porosity, and flow rate. Spine 33:1352-1359. doi:10.​1097/​BRS.​0b013e3181732aa9​
15.
Zurück zum Zitat Mochida J, Toh E, Chiba M, Nishimura K (2001) Treatment of osteoporotic late collapse of a vertebral body of thoracic and lumbar spine. J Spinal Disord 14:393–398CrossRefPubMed Mochida J, Toh E, Chiba M, Nishimura K (2001) Treatment of osteoporotic late collapse of a vertebral body of thoracic and lumbar spine. J Spinal Disord 14:393–398CrossRefPubMed
16.
Zurück zum Zitat Peh WC, Gilula LA, Peck DD (2002) Percutaneous vertebroplasty for severe osteoporotic vertebral body compression fractures. Radiology 223:121–126CrossRefPubMed Peh WC, Gilula LA, Peck DD (2002) Percutaneous vertebroplasty for severe osteoporotic vertebral body compression fractures. Radiology 223:121–126CrossRefPubMed
19.
Zurück zum Zitat Shikata J, Yamamuro T, Iida H, Shimizu K, Yoshikawa J (1990) Surgical treatment for paraplegia resulting from vertebral fractures in senile osteoporosis. Spine 15:485–489CrossRefPubMed Shikata J, Yamamuro T, Iida H, Shimizu K, Yoshikawa J (1990) Surgical treatment for paraplegia resulting from vertebral fractures in senile osteoporosis. Spine 15:485–489CrossRefPubMed
20.
Zurück zum Zitat Soshi S, Shiba R, Kondo H, Murota K (1991) An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 16:1335–1341CrossRefPubMed Soshi S, Shiba R, Kondo H, Murota K (1991) An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 16:1335–1341CrossRefPubMed
21.
Zurück zum Zitat Sugimoto Y, Tanaka M, Konishi H, Takigawa T, Nakanishi K, Misawa H, Ito Y, Ozaki T (2009) Posterior spinal fusion using a pedicle nail system with polymethylmethacrylate in a paraplegic patient after vertebral collapse caused by osteoporosis. Spine J 9:e5–e8. doi:10.1016/j.spinee.2007.10.036 Sugimoto Y, Tanaka M, Konishi H, Takigawa T, Nakanishi K, Misawa H, Ito Y, Ozaki T (2009) Posterior spinal fusion using a pedicle nail system with polymethylmethacrylate in a paraplegic patient after vertebral collapse caused by osteoporosis. Spine J 9:e5–e8. doi:10.​1016/​j.​spinee.​2007.​10.​036
23.
Zurück zum Zitat Takigawa T, Tanaka M, Konishi H, Ikuma H, Misawa H, Sugimoto Y, Nakanishi K, Kuramoto K, Nishida K, Ozaki T (2007) Comparative biomechanical analysis of an improved novel pedicle screw with sheath and bone cement. J Spinal Disord Tech 20:462–467CrossRefPubMed Takigawa T, Tanaka M, Konishi H, Ikuma H, Misawa H, Sugimoto Y, Nakanishi K, Kuramoto K, Nishida K, Ozaki T (2007) Comparative biomechanical analysis of an improved novel pedicle screw with sheath and bone cement. J Spinal Disord Tech 20:462–467CrossRefPubMed
24.
Zurück zum Zitat Tanaka S, Kubota M, Fujimoto Y, Hayashi J, Nishikawa K (1993) Conus medullaris syndrome secondary to an L1 burst fracture in osteoporosis. A case report. Spine 18:2131–2134CrossRefPubMed Tanaka S, Kubota M, Fujimoto Y, Hayashi J, Nishikawa K (1993) Conus medullaris syndrome secondary to an L1 burst fracture in osteoporosis. A case report. Spine 18:2131–2134CrossRefPubMed
26.
Zurück zum Zitat Zindrick MR, Wiltse LL, Widell EH, Thomas JC, Holland WR, Field BT, Spencer CW (1986) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop Relat Res 203:99–112PubMed Zindrick MR, Wiltse LL, Widell EH, Thomas JC, Holland WR, Field BT, Spencer CW (1986) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop Relat Res 203:99–112PubMed
Metadaten
Titel
Clinical application of a pedicle nail system with polymethylmethacrylate for osteoporotic vertebral fracture
verfasst von
Keiya Yamana
Masato Tanaka
Yoshihisa Sugimoto
Tomoyuki Takigawa
Toshifumi Ozaki
Hitoshi Konishi
Publikationsdatum
01.10.2010
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 10/2010
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-010-1402-1

Weitere Artikel der Ausgabe 10/2010

European Spine Journal 10/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.