Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 2/2013

01.02.2013 | Neurophthalmology

Comparison between Hardy–Rand–Rittler 4th edition and Ishihara color plate tests for detection of dyschromatopsia in optic neuropathy

verfasst von: Ruth Huna-Baron, Yoseph Glovinsky, Zohar Habot-Wilner

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 2/2013

Einloggen, um Zugang zu erhalten

Abstract

Background

The aim of this work was to compare the specificity–sensitivity balance of the Hardy–Rand–Rittler (HRR) 4th edition with the Ishihara color plate tests for color-vision defects in patients with optic neuropathy.

Methods

This is a prospective case-control study. The study group included 43 patients (48 eyes) with newly diagnosed optic neuropathy, and the control group included 33 patients (33 right eyes) who were referred to the eye clinic for conditions other than optic nerve or retinal macular disorders. Individuals with visual acuity of less than 20/70 (0.54 Log MAR) were excluded. All patients underwent comprehensive eye examination and color-vision evaluation with both tests in a random order under standardized lighting conditions. The scores of the Ishihara and HRR tests were set as the number of plates identified out of 12 and six respectively.

Results

The receiver operating characteristics (ROC) curve was statistically significantly better when using the HRR test (area under curve [AUC] = 0.93 ± 0.03) than for the Ishihara test (AUC = 0.77 ± 0.05) (P = 0.0006). The best specificity–sensitivity balance for the HRR was 100 % and 79 % respectively, and for the Ishihara test 100 % and 48 % respectively.

Conclusions

The HRR 4th edition test proved to be superior to the Ishihara test in detecting acquired dyschromatopsia due to optic neuropathy. We recommend using the HRR 4th edition test as a screening method for detection of color-vision defects in patients with optic neuropathy.
Literatur
1.
Zurück zum Zitat Francois J, Verriest G (1961) On acquired deficiency of color vision with special reference to its detection and classification by means of the tests of Farnsworth. Vis Res 1:201–219CrossRef Francois J, Verriest G (1961) On acquired deficiency of color vision with special reference to its detection and classification by means of the tests of Farnsworth. Vis Res 1:201–219CrossRef
2.
Zurück zum Zitat Griffin JF, Wray SH (1978) Acquired color vision defects in retrobulbar neuritis. Am J Ophthalmol 86:193–201PubMed Griffin JF, Wray SH (1978) Acquired color vision defects in retrobulbar neuritis. Am J Ophthalmol 86:193–201PubMed
3.
Zurück zum Zitat Cruysberg JR, Pinckers A (1982) Acquired color vision defects in compressive optic neuropathy. Neuro Ophthalmol 2:169–181CrossRef Cruysberg JR, Pinckers A (1982) Acquired color vision defects in compressive optic neuropathy. Neuro Ophthalmol 2:169–181CrossRef
4.
Zurück zum Zitat Melamud A, Hagstrom S, Traboulsi E (2004) Color vision testing. Ophthalmic Genet 25:159–187PubMedCrossRef Melamud A, Hagstrom S, Traboulsi E (2004) Color vision testing. Ophthalmic Genet 25:159–187PubMedCrossRef
5.
Zurück zum Zitat Cox J (1960) Color vision defects acquired in diseases of the eye. Br J Physiol Opt 17:195–216PubMed Cox J (1960) Color vision defects acquired in diseases of the eye. Br J Physiol Opt 17:195–216PubMed
7.
Zurück zum Zitat Katz B (1995) The dyschromatopsia of optic neuritis: a descriptive analysis of data from the optic neuritis treatment trial. Trans Am Ophthalmol Soc 93:685–708PubMed Katz B (1995) The dyschromatopsia of optic neuritis: a descriptive analysis of data from the optic neuritis treatment trial. Trans Am Ophthalmol Soc 93:685–708PubMed
8.
Zurück zum Zitat Schneck ME, Haegerstrom-Portnoy G (1997) Color vision defect type and spatial vision in the optic neuritis treatment trial. Invest Ophthalmol Vis Sci 38:2278–2289PubMed Schneck ME, Haegerstrom-Portnoy G (1997) Color vision defect type and spatial vision in the optic neuritis treatment trial. Invest Ophthalmol Vis Sci 38:2278–2289PubMed
9.
Zurück zum Zitat Hardy LH, Rand G, Rittler MC (1945) Tests for the detection and analysis of color blindness. I. An evaluation of the Ishihara test. Arch Ophthalmol 34:295–302CrossRef Hardy LH, Rand G, Rittler MC (1945) Tests for the detection and analysis of color blindness. I. An evaluation of the Ishihara test. Arch Ophthalmol 34:295–302CrossRef
10.
Zurück zum Zitat Hardy LH, Rand G, Rittler MC (1954) The H-R-R polychromatic plates. 1. A test for the detection, classification, and estimation of the degree of defective color vision. Arch Ophthalmol 51:216–228CrossRef Hardy LH, Rand G, Rittler MC (1954) The H-R-R polychromatic plates. 1. A test for the detection, classification, and estimation of the degree of defective color vision. Arch Ophthalmol 51:216–228CrossRef
11.
Zurück zum Zitat Aroichane M, Pieramici DJ, Miller NR, Vitale S (1996) comparative study of Hardy–Rand–Rittler and Ishihara color plates for the diagnosis of nonglaucomatous optic neuropathy. Can J Ophthalmol 31:350–355PubMed Aroichane M, Pieramici DJ, Miller NR, Vitale S (1996) comparative study of Hardy–Rand–Rittler and Ishihara color plates for the diagnosis of nonglaucomatous optic neuropathy. Can J Ophthalmol 31:350–355PubMed
12.
Zurück zum Zitat Dain SJ (2004) Colorimetric analysis of four editions of the Hardy–Rand–Rittler pseudoisochromatic tests. Vis Neurosci 21:437–443PubMedCrossRef Dain SJ (2004) Colorimetric analysis of four editions of the Hardy–Rand–Rittler pseudoisochromatic tests. Vis Neurosci 21:437–443PubMedCrossRef
13.
Zurück zum Zitat Cole BL, Lian KY, Lakkis C (2006) The new Richmond HRR pseudochromatic test for colour vision is better than the Ishihara test. Clin Exp Optom 89:73–80PubMedCrossRef Cole BL, Lian KY, Lakkis C (2006) The new Richmond HRR pseudochromatic test for colour vision is better than the Ishihara test. Clin Exp Optom 89:73–80PubMedCrossRef
14.
Zurück zum Zitat Bailey JE, Neitz M, Tait DM, Neitz J (2004) Evaluation of an updated HRR color vision test. Vis Neurosci 21:431–436PubMedCrossRef Bailey JE, Neitz M, Tait DM, Neitz J (2004) Evaluation of an updated HRR color vision test. Vis Neurosci 21:431–436PubMedCrossRef
15.
Zurück zum Zitat Beck RW, Cleary PA, Trobe JD, Kaufman DI, Kupersmith MJ, Paty DW, Brown CH (1993) The effect of corticosteroids for acute optic neuritis on the subsequent development of multiple sclerosis. The Optic Neuritis Study Group. N Engl J Med 329:1764–1769PubMedCrossRef Beck RW, Cleary PA, Trobe JD, Kaufman DI, Kupersmith MJ, Paty DW, Brown CH (1993) The effect of corticosteroids for acute optic neuritis on the subsequent development of multiple sclerosis. The Optic Neuritis Study Group. N Engl J Med 329:1764–1769PubMedCrossRef
16.
Zurück zum Zitat Ischemic Optic Neuropathy Decompression Trial Research Group (1995) Optic nerve decompression surgery for nonarteritic anterior ischemic optic neuropathy (AION) is not effective and may be harmful. JAMA 273:625–632CrossRef Ischemic Optic Neuropathy Decompression Trial Research Group (1995) Optic nerve decompression surgery for nonarteritic anterior ischemic optic neuropathy (AION) is not effective and may be harmful. JAMA 273:625–632CrossRef
17.
Zurück zum Zitat Levin LA, Beck RW, Joseph MP, Seiff S, Kraker R (1999) The treatment of traumatic optic neuropathy: the International Optic Nerve Trauma Study. Ophthalmology 106:1268–1277PubMedCrossRef Levin LA, Beck RW, Joseph MP, Seiff S, Kraker R (1999) The treatment of traumatic optic neuropathy: the International Optic Nerve Trauma Study. Ophthalmology 106:1268–1277PubMedCrossRef
18.
Zurück zum Zitat DeLong ER, DeLong DM, Clarke-Pearson DL (1988) Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 44:837–845PubMedCrossRef DeLong ER, DeLong DM, Clarke-Pearson DL (1988) Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 44:837–845PubMedCrossRef
19.
Zurück zum Zitat Bueti D, Walsh V (2009) The parietal cortex and the representation of time, space, number and other magnitudes. Philos Trans R Soc Lond B Biol Sci 364:1831–1840PubMedCrossRef Bueti D, Walsh V (2009) The parietal cortex and the representation of time, space, number and other magnitudes. Philos Trans R Soc Lond B Biol Sci 364:1831–1840PubMedCrossRef
20.
Zurück zum Zitat McCulley TJ, Golnik KC, Lam BL, Feuer WJ (2006) The effect of decreased visual acuity on clinical color vision testing. Am J Ophthalmol 141:194–196PubMedCrossRef McCulley TJ, Golnik KC, Lam BL, Feuer WJ (2006) The effect of decreased visual acuity on clinical color vision testing. Am J Ophthalmol 141:194–196PubMedCrossRef
21.
Zurück zum Zitat Danesh-Meyer HV, Papchenko TL, Savino PJ, Gamble GD (2007) Brightness sensitivity and color perception as predictors of relative afferent pupillary defect. Invest Ophthalmol Vis Sci 48:3616–3621PubMedCrossRef Danesh-Meyer HV, Papchenko TL, Savino PJ, Gamble GD (2007) Brightness sensitivity and color perception as predictors of relative afferent pupillary defect. Invest Ophthalmol Vis Sci 48:3616–3621PubMedCrossRef
22.
Zurück zum Zitat Matti AI, Chu ER, Keane M, Pesudovs K, Chen CS (2011) Comparison of Ishihara and Hardy–Rand–Rittler pseudoisochromatic plates in non-arteritic anterior ischaemic optic neuropathy. Neuro Ophthalmol 35:181–186CrossRef Matti AI, Chu ER, Keane M, Pesudovs K, Chen CS (2011) Comparison of Ishihara and Hardy–Rand–Rittler pseudoisochromatic plates in non-arteritic anterior ischaemic optic neuropathy. Neuro Ophthalmol 35:181–186CrossRef
Metadaten
Titel
Comparison between Hardy–Rand–Rittler 4th edition and Ishihara color plate tests for detection of dyschromatopsia in optic neuropathy
verfasst von
Ruth Huna-Baron
Yoseph Glovinsky
Zohar Habot-Wilner
Publikationsdatum
01.02.2013
Verlag
Springer-Verlag
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 2/2013
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-012-2073-x

Weitere Artikel der Ausgabe 2/2013

Graefe's Archive for Clinical and Experimental Ophthalmology 2/2013 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.