Skip to main content
Erschienen in: European Journal of Applied Physiology 5/2012

01.05.2012 | Original Article

Comparison of artificial neural network (ANN) and partial least squares (PLS) regression models for predicting respiratory ventilation: an exploratory study

verfasst von: Ming-I Brandon Lin, William A. Groves, Andris Freivalds, Eun Gyung Lee, Martin Harper

Erschienen in: European Journal of Applied Physiology | Ausgabe 5/2012

Einloggen, um Zugang zu erhalten

Abstract

The objective of this study was to assess the potential for using artificial neural networks (ANN) to predict inspired minute ventilation \( \left( {\dot{V}_{I} } \right) \) during exercise activities. Six physiological/kinematic measurements obtained from a portable ambulatory monitoring system, along with individual’s anthropometric and demographic characteristics, were employed as input variables to develop and optimize the ANN configuration with respect to reference values simultaneously measured using a pneumotachograph (PT). The generalization ability of the resulting two-hidden-layer ANN model was compared with a linear predictive model developed through partial least squares (PLS) regression, as well as other \( \dot{V}_{I} \) predictive models proposed in the literature. Using an independent dataset recorded from nine 80-min step tests, the results showed that the ANN-estimated \( \dot{V}_{I} \) was highly correlated (R 2 = 0.88) with \( \dot{V}_{I} \) measured by the PT, with a mean difference of approximately 0.9%. In contrast, the PLS and other regression-based models resulted in larger average errors ranging from 7 to 34%. In addition, the ANN model yielded estimates of cumulative total volume that were on average within 1% of reference PT measurements. Compared with established statistical methods, the proposed ANN model demonstrates the potential to provide improved prediction of respiratory ventilation in workplace applications for which the use of traditional laboratory-based instruments is not feasible. Further research should be conducted to investigate the performance of ANNs for different types of physical activity in larger and more varied worker populations.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
Zurück zum Zitat Åstrand P-O, Rodahl K, Dahl HA, Strømme SB (2003) Textbook of work physiology: physiological bases of exercise. Human Kinetics, Champaign, pp 189–205; 503–511 Åstrand P-O, Rodahl K, Dahl HA, Strømme SB (2003) Textbook of work physiology: physiological bases of exercise. Human Kinetics, Champaign, pp 189–205; 503–511
Zurück zum Zitat Bakker HK, Struikenkamp RS, De Vries GA (1980) Dynamics of ventilation, heart rate, and gas exchange: sinusoidal and impulse workloads in man. J Appl Physiol 48:289–301PubMed Bakker HK, Struikenkamp RS, De Vries GA (1980) Dynamics of ventilation, heart rate, and gas exchange: sinusoidal and impulse workloads in man. J Appl Physiol 48:289–301PubMed
Zurück zum Zitat Bland JM, Altman DG (2007) Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 17:571–582 Bland JM, Altman DG (2007) Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 17:571–582
Zurück zum Zitat Djavan B, Remzi M, Zlotta A, Seitz C, Snow P, Marberger M (2002) Novel artificial neural network for early detection of prostate cancer. J Clin Oncol 20:921–929PubMedCrossRef Djavan B, Remzi M, Zlotta A, Seitz C, Snow P, Marberger M (2002) Novel artificial neural network for early detection of prostate cancer. J Clin Oncol 20:921–929PubMedCrossRef
Zurück zum Zitat Duffield R, Dawson B, Pinnington HC, Wong P (2004) Accuracy and reliability of a Cosmed K4b2 portable gas analysis system. J Sci Med Sport 7:11–22PubMedCrossRef Duffield R, Dawson B, Pinnington HC, Wong P (2004) Accuracy and reliability of a Cosmed K4b2 portable gas analysis system. J Sci Med Sport 7:11–22PubMedCrossRef
Zurück zum Zitat Esposito F, Impellizzeri FM, Margonato V, Vanni R, Pizzini G, Veicsteinas A (2004) Validity of heart rate as an indicator of aerobic demand during soccer activities in amateur soccer players. Eur J Appl Physiol 93:167–172PubMedCrossRef Esposito F, Impellizzeri FM, Margonato V, Vanni R, Pizzini G, Veicsteinas A (2004) Validity of heart rate as an indicator of aerobic demand during soccer activities in amateur soccer players. Eur J Appl Physiol 93:167–172PubMedCrossRef
Zurück zum Zitat Geladi P, Kowalski BR (1986) Partial least-squares regression—a tutorial. Anal Chim Acta 185:1–17CrossRef Geladi P, Kowalski BR (1986) Partial least-squares regression—a tutorial. Anal Chim Acta 185:1–17CrossRef
Zurück zum Zitat Geman S, Bienenstock E, Doursat R (1992) Neural networks and the bias variance dilemma. Neural Comput 4:1–58CrossRef Geman S, Bienenstock E, Doursat R (1992) Neural networks and the bias variance dilemma. Neural Comput 4:1–58CrossRef
Zurück zum Zitat Haenlein M, Kaplan AM (2004) A beginner's guide to partial least squares analysis. Underst Stat 3:283–297 Haenlein M, Kaplan AM (2004) A beginner's guide to partial least squares analysis. Underst Stat 3:283–297
Zurück zum Zitat Han JN, Stegen K, Cauberghs M, Van de Woestijne KP (1997) Influence of awareness of the recording of breathing on respiratory pattern in healthy humans. Eur Respir J 10:161–166 Han JN, Stegen K, Cauberghs M, Van de Woestijne KP (1997) Influence of awareness of the recording of breathing on respiratory pattern in healthy humans. Eur Respir J 10:161–166
Zurück zum Zitat Hart C (1998) Theory and evaluation of a new physiologic sampling pump. Department of Environmental Health. University of Washington, Seattle Hart C (1998) Theory and evaluation of a new physiologic sampling pump. Department of Environmental Health. University of Washington, Seattle
Zurück zum Zitat Haykin S (2008) Neural networks and learning machines. Prentice Hall, Upper Saddle River, pp 216–226 Haykin S (2008) Neural networks and learning machines. Prentice Hall, Upper Saddle River, pp 216–226
Zurück zum Zitat Holmer I, Gavhed D (2007) Classification of metabolic and respiratory demands in fire fighting activity with extreme workloads. Appl Ergon 38:45–52PubMedCrossRef Holmer I, Gavhed D (2007) Classification of metabolic and respiratory demands in fire fighting activity with extreme workloads. Appl Ergon 38:45–52PubMedCrossRef
Zurück zum Zitat Hornik K, Stinchcombe M, White H (1989) Multilayer feedforward networks are universal approximators. Neural Netw 2:359–366CrossRef Hornik K, Stinchcombe M, White H (1989) Multilayer feedforward networks are universal approximators. Neural Netw 2:359–366CrossRef
Zurück zum Zitat Kucharski R (1980) A personal dust sampler simulating variable human lung function. Br J Ind Med 37:194–196PubMed Kucharski R (1980) A personal dust sampler simulating variable human lung function. Br J Ind Med 37:194–196PubMed
Zurück zum Zitat Levine MS (1994) A respiration-modulated personal air sampling pump. Appl Occup Environ Hyg 9:994–1005CrossRef Levine MS (1994) A respiration-modulated personal air sampling pump. Appl Occup Environ Hyg 9:994–1005CrossRef
Zurück zum Zitat Lin MI, Groves WA, Freivalds A, Lee EG, Harper M, Slaven JE, Lee L (2008) Exposure assessment by physiologic sampling pump–prediction of minute ventilation using a portable respiratory inductive plethysmograph system. J Environ Monit 10:1179–1186PubMedCrossRef Lin MI, Groves WA, Freivalds A, Lee EG, Harper M, Slaven JE, Lee L (2008) Exposure assessment by physiologic sampling pump–prediction of minute ventilation using a portable respiratory inductive plethysmograph system. J Environ Monit 10:1179–1186PubMedCrossRef
Zurück zum Zitat Lin MI, Groves WA, Freivalds A, Lee L, Lee EG, Slaven JE, Harper M (2010) Laboratory evaluation of a physiologic sampling pump (PSP). J Environ Monit 12:1415–1421PubMedCrossRef Lin MI, Groves WA, Freivalds A, Lee L, Lee EG, Slaven JE, Harper M (2010) Laboratory evaluation of a physiologic sampling pump (PSP). J Environ Monit 12:1415–1421PubMedCrossRef
Zurück zum Zitat Liu Y, Shih SM, Tian SL, Zhong YJ, Li L (2009) Lower extremity joint torque predicted by using artificial neural network during vertical jump. J Biomech 42:906–911PubMedCrossRef Liu Y, Shih SM, Tian SL, Zhong YJ, Li L (2009) Lower extremity joint torque predicted by using artificial neural network during vertical jump. J Biomech 42:906–911PubMedCrossRef
Zurück zum Zitat Matignon R (2005) Neural network modeling using SAS enterprise miner. AuthorHouse, Bloomington, pp. 140–146 Matignon R (2005) Neural network modeling using SAS enterprise miner. AuthorHouse, Bloomington, pp. 140–146
Zurück zum Zitat Moayed FA, Shell RL (2011) Application of artificial neural network models in occupational safety and health utilizing ordinal variables. Ann Occup Hyg 55:132–142PubMedCrossRef Moayed FA, Shell RL (2011) Application of artificial neural network models in occupational safety and health utilizing ordinal variables. Ann Occup Hyg 55:132–142PubMedCrossRef
Zurück zum Zitat Robergs RA, Landwehr R (2002) The Surprising History of The HRmax=220-age Equation. J Exerc Physiol Online 5:1–10 Robergs RA, Landwehr R (2002) The Surprising History of The HRmax=220-age Equation. J Exerc Physiol Online 5:1–10
Zurück zum Zitat Sackner JD, Nixon AJ, Davis B, Atkins N, Sackner MA (1980) Non-invasive measurement of ventilation during exercise using a respiratory inductive plethysmograph. I. Am Rev Respir Dis 122:867–871PubMed Sackner JD, Nixon AJ, Davis B, Atkins N, Sackner MA (1980) Non-invasive measurement of ventilation during exercise using a respiratory inductive plethysmograph. I. Am Rev Respir Dis 122:867–871PubMed
Zurück zum Zitat Satoh T, Higashi T, Sakurai H, Omae K (1989) Development of a new exposure monitoring system considering pulmonary ventilation (DEM 1). Keio J Med 38:432–442PubMedCrossRef Satoh T, Higashi T, Sakurai H, Omae K (1989) Development of a new exposure monitoring system considering pulmonary ventilation (DEM 1). Keio J Med 38:432–442PubMedCrossRef
Zurück zum Zitat Smolander J, Juuti T, Kinnunen ML, Laine K, Louhevaara V, Mannikko K, Rusko H (2008) A new heart rate variability-based method for the estimation of oxygen consumption without individual laboratory calibration: application example on postal workers. Appl Ergon 39:325–331PubMedCrossRef Smolander J, Juuti T, Kinnunen ML, Laine K, Louhevaara V, Mannikko K, Rusko H (2008) A new heart rate variability-based method for the estimation of oxygen consumption without individual laboratory calibration: application example on postal workers. Appl Ergon 39:325–331PubMedCrossRef
Zurück zum Zitat Torres A, Bertrand-Krajewski JL (2008) Partial Least Squares local calibration of a UV-visible spectrometer used for in situ measurements of COD and TSS concentrations in urban drainage systems. Water Sci Technol 57:581–588PubMedCrossRef Torres A, Bertrand-Krajewski JL (2008) Partial Least Squares local calibration of a UV-visible spectrometer used for in situ measurements of COD and TSS concentrations in urban drainage systems. Water Sci Technol 57:581–588PubMedCrossRef
Zurück zum Zitat Wasserman K, Hansen JE, Sue DY, Stringer WW, Whipp BJ (2004) Principles of exercise testing and interpretation: including pathophysiology and clinical applications. Lippincott Williams & Wilkins, Philadelphia, pp 3–58 Wasserman K, Hansen JE, Sue DY, Stringer WW, Whipp BJ (2004) Principles of exercise testing and interpretation: including pathophysiology and clinical applications. Lippincott Williams & Wilkins, Philadelphia, pp 3–58
Zurück zum Zitat Weissman C, Askanazi J, Milic-Emili J, Kinney JM (1984) Effect of respiratory apparatus on respiration. J Appl Physiol 57:475–480 Weissman C, Askanazi J, Milic-Emili J, Kinney JM (1984) Effect of respiratory apparatus on respiration. J Appl Physiol 57:475–480
Zurück zum Zitat Widmaier EP, Raff H, Strang KT (2005) Vander’s human physiology. McGraw-Hill Science, New York, pp 494–514 Widmaier EP, Raff H, Strang KT (2005) Vander’s human physiology. McGraw-Hill Science, New York, pp 494–514
Zurück zum Zitat Wilhelm FH, Roth WT, Sackner MA (2003) The lifeShirt. An advanced system for ambulatory measurement of respiratory and cardiac function. Behav Modif 27:671–691PubMedCrossRef Wilhelm FH, Roth WT, Sackner MA (2003) The lifeShirt. An advanced system for ambulatory measurement of respiratory and cardiac function. Behav Modif 27:671–691PubMedCrossRef
Zurück zum Zitat Witt JD, Fisher JR, Guenette JA, Cheong KA, Wilson BJ, Sheel AW (2006) Measurement of exercise ventilation by a portable respiratory inductive plethysmograph. Respir Physiol Neurobiol 154:389–395PubMedCrossRef Witt JD, Fisher JR, Guenette JA, Cheong KA, Wilson BJ, Sheel AW (2006) Measurement of exercise ventilation by a portable respiratory inductive plethysmograph. Respir Physiol Neurobiol 154:389–395PubMedCrossRef
Zurück zum Zitat Wold S, Sjöström M, Eriksson L (2001) PLS-regression: a basic tool of chemometrics. Chemom Intell Lab Syst 58:109–130 Wold S, Sjöström M, Eriksson L (2001) PLS-regression: a basic tool of chemometrics. Chemom Intell Lab Syst 58:109–130
Metadaten
Titel
Comparison of artificial neural network (ANN) and partial least squares (PLS) regression models for predicting respiratory ventilation: an exploratory study
verfasst von
Ming-I Brandon Lin
William A. Groves
Andris Freivalds
Eun Gyung Lee
Martin Harper
Publikationsdatum
01.05.2012
Verlag
Springer-Verlag
Erschienen in
European Journal of Applied Physiology / Ausgabe 5/2012
Print ISSN: 1439-6319
Elektronische ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-011-2118-6

Weitere Artikel der Ausgabe 5/2012

European Journal of Applied Physiology 5/2012 Zur Ausgabe

Neu im Fachgebiet Arbeitsmedizin

Elterliches Belastungserleben, Unaufmerksamkeits‑/Hyperaktivitätssymptome und elternberichtete ADHS bei Kindern und Jugendlichen: Ergebnisse aus der KiGGS-Studie

Open Access ADHS Leitthema

Die Aufmerksamkeitsdefizit‑/Hyperaktivitätsstörung (ADHS) ist eine der häufigsten psychischen Störungen im Kindes- und Jugendalter [ 1 ]. In Deutschland beträgt die Prävalenz einer elternberichteten ADHS-Diagnose bei Kindern und Jugendlichen 4,4 % …

Substanzkonsum und Nutzung von sozialen Medien, Computerspielen und Glücksspielen unter Auszubildenden an beruflichen Schulen

Open Access Leitthema

Die Begrenzung von Schäden durch Substanzkonsum und andere abhängige Verhaltensweisen von Jugendlichen und jungen Erwachsenen ist ein wichtiges Anliegen der öffentlichen Gesundheit. Der Übergang von der Adoleszenz zum jungen Erwachsenenalter ist …

Berufsbelastung und Stressbewältigung von weiblichen und männlichen Auszubildenden

Leitthema

In der Öffentlichkeit wird die berufliche Ausbildung oftmals unter ökonomischen Gesichtspunkten diskutiert: Mit den geburtenstarken Jahrgängen gehen erfahrene Fachkräfte in Rente und von nachfolgenden Generationen rücken zu wenige Arbeitskräfte …

Rauschtrinken in der frühen Adoleszenz

COVID-19 Leitthema

Alkohol ist in Deutschland die mit Abstand am häufigsten konsumierte psychoaktive Substanz. Mehr als 2 Drittel aller Erwachsenen im Alter von 18 bis 64 Jahren (70,5 %) hat 2021 in den letzten 30 Tagen Alkohol konsumiert [ 1 ]. Von diesen …