Abstract

The purpose of the study was to assess the effectiveness of contrast-enhanced ultrasonography (CEUS) in endoleak classification after endovascular treatment of an abdominal aortic aneurysm compared to computed tomography angiography (CTA). From May 2001 to April 2003, 10 patients with endoleaks already detected by CTA underwent CEUS with Sonovue® to confirm the CTA classification or to reclassify the endoleak. In three conflicting cases, the patients were also studied with conventional angiography. CEUS confirmed the CTA classification in seven cases (type II endoleaks). Two CTA type III endoleaks were classified as type II using CEUS and one CTA type II endoleak was classified as type I by CEUS. Regarding the cases with discordant classification, conventional angiography confirmed the ultrasound classification. Additionally, CEUS documented the origin of type II endoleaks in all cases. After CEUS reclassification of endoleaks, a significant change in patient management occurred in three cases. CEUS allows a better attribution of the origin of the endoleak, as it shows the flow in real time. CEUS is more specific than CTA in endoleak classification and gives more accurate information in therapeutic planning.
Literatur
1.
Zurück zum Zitat Parodi JC, Palmaz JC, Barone HD (1991) Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 5:491–499PubMedCrossRef Parodi JC, Palmaz JC, Barone HD (1991) Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 5:491–499PubMedCrossRef
2.
Zurück zum Zitat Adriaensen ME, Bosch JL, Halpern EF, et al. (2002) Elective endovascular versus open surgical repair of abdominal aortic aneurysms: systematic review of short-term results. Radiology 24:739–747 Adriaensen ME, Bosch JL, Halpern EF, et al. (2002) Elective endovascular versus open surgical repair of abdominal aortic aneurysms: systematic review of short-term results. Radiology 24:739–747
3.
Zurück zum Zitat Bendick PJ, Bove PG, Long GW, et al. (2003) Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts. J Vasc Surg 7:381–385CrossRef Bendick PJ, Bove PG, Long GW, et al. (2003) Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts. J Vasc Surg 7:381–385CrossRef
4.
Zurück zum Zitat White RA, Donaayre C, Walot I, et al. (2000) Abdominal aortic aneurysm rupture following endoluminal graft deployment: Report of a predictable event. J Endovasc Ther 7:257–262PubMedCrossRef White RA, Donaayre C, Walot I, et al. (2000) Abdominal aortic aneurysm rupture following endoluminal graft deployment: Report of a predictable event. J Endovasc Ther 7:257–262PubMedCrossRef
5.
Zurück zum Zitat White GH, May J, Waugh RC, et al. (1998) Type I and II endoleaks: A more useful classification for reporting results of endoluminal AAA repair. J Endovasc Surg 5:189–191PubMedCrossRef White GH, May J, Waugh RC, et al. (1998) Type I and II endoleaks: A more useful classification for reporting results of endoluminal AAA repair. J Endovasc Surg 5:189–191PubMedCrossRef
6.
Zurück zum Zitat White GH, May J, Waugh RC, et al. (1998) Type III and type IV endoleaks: Toward a complete definition of blood flow in the sac after endoluminal AAA repair. J Endovasc Surg 5:305–309PubMedCrossRef White GH, May J, Waugh RC, et al. (1998) Type III and type IV endoleaks: Toward a complete definition of blood flow in the sac after endoluminal AAA repair. J Endovasc Surg 5:305–309PubMedCrossRef
7.
Zurück zum Zitat Karch LA, Henretta JP, Hodgson KJ (1999) Algorithm for the diagnosis and treatment of endoleaks. Am J Surg 178:225–231PubMedCrossRef Karch LA, Henretta JP, Hodgson KJ (1999) Algorithm for the diagnosis and treatment of endoleaks. Am J Surg 178:225–231PubMedCrossRef
8.
Zurück zum Zitat Golzarian J, Dussaussois L, Abada HT (1998) Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. Am J Roentgenol 171:329–331 Golzarian J, Dussaussois L, Abada HT (1998) Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. Am J Roentgenol 171:329–331
9.
Zurück zum Zitat Gorich J, Rilinger N, Sokiranski R, et al. (1999) Leakages after endovascular repair of aortic aneurysms: Classification based on findings at CT, angiography, and radiography. Radiology 213:767–772PubMed Gorich J, Rilinger N, Sokiranski R, et al. (1999) Leakages after endovascular repair of aortic aneurysms: Classification based on findings at CT, angiography, and radiography. Radiology 213:767–772PubMed
10.
Zurück zum Zitat Rozenblit A, Patlas M, Rosenbaum A, et al. (2003) Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: Value of unenhanced and delayed helical CT acquisitions. Radiology 227:426–433PubMed Rozenblit A, Patlas M, Rosenbaum A, et al. (2003) Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: Value of unenhanced and delayed helical CT acquisitions. Radiology 227:426–433PubMed
11.
Zurück zum Zitat Greenfield AL, Halpern EJ, Bonn J, et al. (2002) Application of duplex US for characterization of endoleaks in abdominal aortic stent grafts: Report of five cases. Radiology 225:845–851PubMed Greenfield AL, Halpern EJ, Bonn J, et al. (2002) Application of duplex US for characterization of endoleaks in abdominal aortic stent grafts: Report of five cases. Radiology 225:845–851PubMed
12.
Zurück zum Zitat McLafferty RB, McCrary BS, Mattos MA, et al. (2002) The use of colour-flow duplex scan for the detection of endoleaks. J Vasc Surg 36:100–104PubMedCrossRef McLafferty RB, McCrary BS, Mattos MA, et al. (2002) The use of colour-flow duplex scan for the detection of endoleaks. J Vasc Surg 36:100–104PubMedCrossRef
13.
Zurück zum Zitat Raman KG, Missing-Carroll N, Richardson T, et al. (2003) Flow-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair. J Vasc Surg 38:645–651PubMedCrossRef Raman KG, Missing-Carroll N, Richardson T, et al. (2003) Flow-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair. J Vasc Surg 38:645–651PubMedCrossRef
14.
Zurück zum Zitat D’Audiffret A, Desgranges P, Kobeiter DH, et al. (2001) Follow-up evaluation of endoluminally treated abdominal aneurysms with duplex ultrasonography: validation with computed tomography. J Vasc Surg 33:42–50PubMedCrossRef D’Audiffret A, Desgranges P, Kobeiter DH, et al. (2001) Follow-up evaluation of endoluminally treated abdominal aneurysms with duplex ultrasonography: validation with computed tomography. J Vasc Surg 33:42–50PubMedCrossRef
15.
Zurück zum Zitat Sato DT, Goff CD, Gregory RT, et al. (1998) Endoleak after aortic stent graft repair: Diagnosis by colour duplex ultrasound scan versus computed tomography scan. J Vasc Surg 28:657–663PubMedCrossRef Sato DT, Goff CD, Gregory RT, et al. (1998) Endoleak after aortic stent graft repair: Diagnosis by colour duplex ultrasound scan versus computed tomography scan. J Vasc Surg 28:657–663PubMedCrossRef
16.
Zurück zum Zitat Zannetti S, De Rango P, Parente B, et al. (2000) Role of duplex scan in endoleak detection after endoluminal abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg 19:531–535PubMedCrossRef Zannetti S, De Rango P, Parente B, et al. (2000) Role of duplex scan in endoleak detection after endoluminal abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg 19:531–535PubMedCrossRef
17.
Zurück zum Zitat Pages S, Favre JP, Cerisier A, et al. (2001) Comparison of colour duplex ultrasound and computed tomography scan for surveillance after aortic endografting. Ann Vasc Surg 15:155–162PubMedCrossRef Pages S, Favre JP, Cerisier A, et al. (2001) Comparison of colour duplex ultrasound and computed tomography scan for surveillance after aortic endografting. Ann Vasc Surg 15:155–162PubMedCrossRef
18.
Zurück zum Zitat Wolf YG, Johnson BL, Hill BR, et al. (2000) Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair. J Vasc Surg 32:1142–1148PubMedCrossRef Wolf YG, Johnson BL, Hill BR, et al. (2000) Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair. J Vasc Surg 32:1142–1148PubMedCrossRef
19.
Zurück zum Zitat Heilberger P, Schunn C, Ritter W, et al. (1997) Postoperative colour flow duplex scanning in aortic endograft. J Endovasc Surg 4:262–271PubMedCrossRef Heilberger P, Schunn C, Ritter W, et al. (1997) Postoperative colour flow duplex scanning in aortic endograft. J Endovasc Surg 4:262–271PubMedCrossRef
20.
Zurück zum Zitat McWilliams RG, Martin J, White D, et al. (1999) Use of contrast-enhanced ultrasound in follow-up after endovascular aortic aneurysm repair. J Vasc Intervent Radiol 10:1107–1114CrossRef McWilliams RG, Martin J, White D, et al. (1999) Use of contrast-enhanced ultrasound in follow-up after endovascular aortic aneurysm repair. J Vasc Intervent Radiol 10:1107–1114CrossRef
21.
Zurück zum Zitat McWilliams RG, Martin J, White D, et al. (2002) Detection of endoleak with enhanced ultrasound imaging: comparison with biphasic computed tomography. J Endovasc Ther 9:170–179PubMedCrossRef McWilliams RG, Martin J, White D, et al. (2002) Detection of endoleak with enhanced ultrasound imaging: comparison with biphasic computed tomography. J Endovasc Ther 9:170–179PubMedCrossRef
22.
Zurück zum Zitat Giannoni MF, Palombo G, Sbarigia E, et al. (2003) Contrast-enhanced ultrasound imaging for aortic stent-graft surveillance. J Endovasc Ther 10:208–217PubMedCrossRef Giannoni MF, Palombo G, Sbarigia E, et al. (2003) Contrast-enhanced ultrasound imaging for aortic stent-graft surveillance. J Endovasc Ther 10:208–217PubMedCrossRef
23.
Zurück zum Zitat Napoli V, Bargellini I, Sardella S, et al. (2004) Abdominal aortic aneurysm: Contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology 233:217–225PubMed Napoli V, Bargellini I, Sardella S, et al. (2004) Abdominal aortic aneurysm: Contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology 233:217–225PubMed
24.
Zurück zum Zitat Bargellini I, Napoli V, Petruzzi P, et al. (2005) Type II lumbar endoleaks: Hemodynamic differentiation by contrast enhanced ultrasound scanning and influence on aneurysm enlargement after endovascular aneurysm repair. J Vasc Surg 41:10–18PubMedCrossRef Bargellini I, Napoli V, Petruzzi P, et al. (2005) Type II lumbar endoleaks: Hemodynamic differentiation by contrast enhanced ultrasound scanning and influence on aneurysm enlargement after endovascular aneurysm repair. J Vasc Surg 41:10–18PubMedCrossRef
25.
Zurück zum Zitat Stravropoulos W, Clark TWI, Carpenter JP, et al. (2005) Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysms. J Vasc Intervent Radiol 16:663–667 Stravropoulos W, Clark TWI, Carpenter JP, et al. (2005) Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysms. J Vasc Intervent Radiol 16:663–667
26.
Zurück zum Zitat White RA (2000) Endograft surveillance: a priority for long-term device performance [letter]. J Endovasc Ther 7:522PubMedCrossRef White RA (2000) Endograft surveillance: a priority for long-term device performance [letter]. J Endovasc Ther 7:522PubMedCrossRef
27.
Zurück zum Zitat Harris PL, Vallabhanami SR, Desgranges P, et al. for the Eurostar Collaborators (2000) Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience. J Vasc Surg 32:739–749PubMedCrossRef Harris PL, Vallabhanami SR, Desgranges P, et al. for the Eurostar Collaborators (2000) Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: The EUROSTAR experience. J Vasc Surg 32:739–749PubMedCrossRef
28.
Zurück zum Zitat Thurnher S, Cejna M (2002) Imaging of aortic stent-grafts and endoleaks. Radiol Clin N Am 40:799–833PubMedCrossRef Thurnher S, Cejna M (2002) Imaging of aortic stent-grafts and endoleaks. Radiol Clin N Am 40:799–833PubMedCrossRef
29.
Zurück zum Zitat Ashoke R, Brown L, Rodway A, et al. (2005) Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: A systematic review. J Endovasc Ther 12:297–305PubMedCrossRef Ashoke R, Brown L, Rodway A, et al. (2005) Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: A systematic review. J Endovasc Ther 12:297–305PubMedCrossRef
Metadaten
Titel
Comparison of Contrast-Enhanced Ultrasound and Computed Tomography in Classifying Endoleaks After Endovascular Treatment of Abdominal Aorta Aneurysms: Preliminary Experience
verfasst von
Gianpaolo Carrafiello
Domenico Laganà
Chiara Recaldini
Monica Mangini
Elena Bertolotti
Roberto Caronno
Matteo Tozzi
Gabriele Piffaretti
Eugenio Annibale Genovese
Carlo Fugazzola
Publikationsdatum
01.12.2006
Erschienen in
CardioVascular and Interventional Radiology / Ausgabe 6/2006
Print ISSN: 0174-1551
Elektronische ISSN: 1432-086X
DOI
https://doi.org/10.1007/s00270-005-0267-x

Weitere Artikel der Ausgabe 6/2006

CardioVascular and Interventional Radiology 6/2006 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.