Purpose

We aimed to compare the accuracy of point-of-care ultrasonography (POCUS) and X-ray (XR) in the diagnosis of knee bone fractures and fracture characteristics in cases of injuries to the knee.

Methods

The study was conducted in the emergency department (ED) of a tertiary hospital between March 2017 and March 2019. It included patients who presented to the ED with isolated knee injuries, were suspected to have a bony lesion based on clinical examinations, and were ultimately referred for XR. Five emergency physicians (EPs) who had at least three years of ED experience participated in the study. Before the study, these EPs received training on knee examination and radiographic investigation of the knee joint. They were also trained on how to assess the knee joint using POCUS. The knee bones, patella, femur, tibia, and fibula were evaluated. A POCUS examination of the knee bones was carried out according to the eight-step Kozaci Protocol.

Results

This study included 92 patients with knee trauma. The mean age of the patients was 34 ± 16 years (6–55 years). Using POCUS and XR, fractures were detected in 40 (43%) and 32 patients (35%), respectively. Relative to XR, for detecting fractures, POCUS showed sensitivity, specificity, positive predictive value, and negative predictive value of 97%, 85%, 78%, 98%, respectively, and the kappa value was 0.774. POCUS examination revealed hematoma and edema in the soft tissue in 34 (37%) patients and hemarthrosis in 33 patients (36%).

Conclusion

XR is the first and most widely used imaging modality to identify fractures of the knee bone trauma. However, POCUS examination can successfully diagnose bony lesions of the knee in patients with stable vital signs and without life-threatening injuries. It can also easily diagnose hematoma and hemarthrosis. Therefore, POCUS can be used as a diagnostic tool in emergency situations where XR is not available.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Teh J, Kambouroglou G, Newton J. Investigation of acute knee injury. BMJ. 2012;344:e3167.CrossRef Teh J, Kambouroglou G, Newton J. Investigation of acute knee injury. BMJ. 2012;344:e3167.CrossRef
2.
Zurück zum Zitat Avci M, Kozaci N. Comparison of X-Ray imaging and computed tomography scan in the evaluation of knee trauma. Med (Kaunas). 2019;55(10):623. Avci M, Kozaci N. Comparison of X-Ray imaging and computed tomography scan in the evaluation of knee trauma. Med (Kaunas). 2019;55(10):623.
3.
Zurück zum Zitat Venkatasamya A, Ehlingerb M, Bierrya G. Acute traumatic knee radiographs: beware of lesions of little expression but of great significance. Diagn Interv Imaging. 2014;95(6):551–60.CrossRef Venkatasamya A, Ehlingerb M, Bierrya G. Acute traumatic knee radiographs: beware of lesions of little expression but of great significance. Diagn Interv Imaging. 2014;95(6):551–60.CrossRef
4.
Zurück zum Zitat Kozaci N, Ay MO, Avci M, Turhan S, Donertas E, Celik A, Ararat E, Akgun E. The comparison of point-of-care ultrasonography and radiography in the diagnosis of tibia and fibula fractures. Injury. 2017;48(7):1628–35.CrossRef Kozaci N, Ay MO, Avci M, Turhan S, Donertas E, Celik A, Ararat E, Akgun E. The comparison of point-of-care ultrasonography and radiography in the diagnosis of tibia and fibula fractures. Injury. 2017;48(7):1628–35.CrossRef
5.
Zurück zum Zitat Avcı M, Kozacı N, Beydilli İ, Yılmaz F, Eden AO, Turhan S. The comparison of bedside point-of-care ultrasound and computed tomography in elbow injuries. Am J Emerg Med. 2016;34(11):2186–90.CrossRef Avcı M, Kozacı N, Beydilli İ, Yılmaz F, Eden AO, Turhan S. The comparison of bedside point-of-care ultrasound and computed tomography in elbow injuries. Am J Emerg Med. 2016;34(11):2186–90.CrossRef
6.
Zurück zum Zitat Alves TI, Girish G, Brigido MK, Jacobson JA. US of the knee: scanning techniques, pitfalls, and pathologic conditions. Radiographics. 2016;36(6):1759–75.CrossRef Alves TI, Girish G, Brigido MK, Jacobson JA. US of the knee: scanning techniques, pitfalls, and pathologic conditions. Radiographics. 2016;36(6):1759–75.CrossRef
7.
Zurück zum Zitat Razek A, Fouda NS, Elmetwaley N, Elbogdady E. Sonography of the knee joint. J Ultrasound. 2009;12(2):53–60.CrossRef Razek A, Fouda NS, Elmetwaley N, Elbogdady E. Sonography of the knee joint. J Ultrasound. 2009;12(2):53–60.CrossRef
8.
Zurück zum Zitat Kozaci N, Ay MO, Avci M, Beydilli I, Turhan S, Donertas E, Ararat E. The comparison of radiography and point-of-care ultrasonography in the diagnosis and management of metatarsal fractures. Injury. 2017;48(2):542–7.CrossRef Kozaci N, Ay MO, Avci M, Beydilli I, Turhan S, Donertas E, Ararat E. The comparison of radiography and point-of-care ultrasonography in the diagnosis and management of metatarsal fractures. Injury. 2017;48(2):542–7.CrossRef
9.
Zurück zum Zitat Kozaci N, Ay MO, Akcimen M, Turhan G, Sasmaz I, Turhan S, Celik A. Evaluation of the effectiveness of bedside point-of-care ultrasound in the diagnosis and management of distal radius fractures. Am J Emerg Med. 2015;33(1):67–71.CrossRef Kozaci N, Ay MO, Akcimen M, Turhan G, Sasmaz I, Turhan S, Celik A. Evaluation of the effectiveness of bedside point-of-care ultrasound in the diagnosis and management of distal radius fractures. Am J Emerg Med. 2015;33(1):67–71.CrossRef
10.
Zurück zum Zitat Avci M, Kozaci N, Tulubas G, Caliskan G, Yuksel A, Karaca A, Doganay F, Etli I. Comparison of point-of-care ultrasonography and radiography in the diagnosis of long-bone fractures. Med (Kaunas). 2019;55(7):355. Avci M, Kozaci N, Tulubas G, Caliskan G, Yuksel A, Karaca A, Doganay F, Etli I. Comparison of point-of-care ultrasonography and radiography in the diagnosis of long-bone fractures. Med (Kaunas). 2019;55(7):355.
11.
Zurück zum Zitat Kozaci N, Ay MO, Akcimen M, Sasmaz I, Turhan G, Boz A. The effectiveness of bedside point-of-care ultrasonography in the diagnosis and management of metacarpal fractures. Am J Emerg Med. 2015;33(10):1468–72.CrossRef Kozaci N, Ay MO, Akcimen M, Sasmaz I, Turhan G, Boz A. The effectiveness of bedside point-of-care ultrasonography in the diagnosis and management of metacarpal fractures. Am J Emerg Med. 2015;33(10):1468–72.CrossRef
12.
Zurück zum Zitat Acuna J, Situ-LaCasse E, Jamplis RP, Amini R, Adhikari S. Point-of-care ultrasound evaluation of tibial avulsion fractures. Cureus. 2018;10(5):2677. Acuna J, Situ-LaCasse E, Jamplis RP, Amini R, Adhikari S. Point-of-care ultrasound evaluation of tibial avulsion fractures. Cureus. 2018;10(5):2677.
13.
Zurück zum Zitat Carter K, Nesper A, Gharahbaghian L, Perera P. Ultrasound detection of patellar fracture and evaluation of the knee extensor mechanism in the emergency department. West J Emerg Med. 2016;17(6):814–6.CrossRef Carter K, Nesper A, Gharahbaghian L, Perera P. Ultrasound detection of patellar fracture and evaluation of the knee extensor mechanism in the emergency department. West J Emerg Med. 2016;17(6):814–6.CrossRef
14.
Zurück zum Zitat Cho KH, Lee SM, Lee YH, Suh KJ. Ultrasound diagnosis of either an occult or missed fracture of an extremity in pediatric-aged children Korean. J Radiol. 2010;11(1):84–94. Cho KH, Lee SM, Lee YH, Suh KJ. Ultrasound diagnosis of either an occult or missed fracture of an extremity in pediatric-aged children Korean. J Radiol. 2010;11(1):84–94.
15.
Zurück zum Zitat Kozaci N, Avcı M, Ararat E, Pinarbasili T, Ozkaya M, Etli I, Donertas E, Karakoyun OF. Comparison of ultrasonography and computed tomography in the determination of traumatic thoracic injuries. Am J Emerg Med. 2019;37(5):864–8.CrossRef Kozaci N, Avcı M, Ararat E, Pinarbasili T, Ozkaya M, Etli I, Donertas E, Karakoyun OF. Comparison of ultrasonography and computed tomography in the determination of traumatic thoracic injuries. Am J Emerg Med. 2019;37(5):864–8.CrossRef
16.
Zurück zum Zitat Wang CY, Wang HK, Hsu CY, Shieh JY, Wang TG, Jiang CC. Role of sonographic examination in traumatic knee internal derangement. Arch Phys Med Rehabil. 2007;88(8):984–7.CrossRef Wang CY, Wang HK, Hsu CY, Shieh JY, Wang TG, Jiang CC. Role of sonographic examination in traumatic knee internal derangement. Arch Phys Med Rehabil. 2007;88(8):984–7.CrossRef
17.
Zurück zum Zitat Ghosh N, Kruse D, Subeh M, Lahham S, Fox JC. Comparing point-of-care-ultrasound (POCUS) to MRI for the diagnosis of medial compartment knee injuries. J MedUltrasound. 2017;25(3):167–72. Ghosh N, Kruse D, Subeh M, Lahham S, Fox JC. Comparing point-of-care-ultrasound (POCUS) to MRI for the diagnosis of medial compartment knee injuries. J MedUltrasound. 2017;25(3):167–72.
18.
Zurück zum Zitat Rippey J. Ultrasound for knee effusion: lipohaemarthrosis and tibial plateau fracture. Aust J Ultrasound Med. 2014;17(4):159–66.CrossRef Rippey J. Ultrasound for knee effusion: lipohaemarthrosis and tibial plateau fracture. Aust J Ultrasound Med. 2014;17(4):159–66.CrossRef
19.
Zurück zum Zitat Singh A, Mangat I, Thukral C, Gupta K. Diagnostic accuracy of ultrasonography in evaluation of knee injuries with magnetic resonance imaging correlation. Int J Anat Radiol Surg. 2018;7(1):50–5. Singh A, Mangat I, Thukral C, Gupta K. Diagnostic accuracy of ultrasonography in evaluation of knee injuries with magnetic resonance imaging correlation. Int J Anat Radiol Surg. 2018;7(1):50–5.
20.
Zurück zum Zitat Avci M, Kozaci N, Yuksel S, Etli I, Yilmaz Y. Comparison of radiography and computed tomography in emergency department evaluation of ankle trauma. Ann Med Res. 2019;26(5):867–72. Avci M, Kozaci N, Yuksel S, Etli I, Yilmaz Y. Comparison of radiography and computed tomography in emergency department evaluation of ankle trauma. Ann Med Res. 2019;26(5):867–72.
21.
Zurück zum Zitat Fleiss JL. Statistical methods for rates and proportions. 2nd ed. New York: John Wiley&SonsInc; 1981. Fleiss JL. Statistical methods for rates and proportions. 2nd ed. New York: John Wiley&SonsInc; 1981.
22.
Zurück zum Zitat Draghi F, Urciuoli L, Alessandrino F, Corti R, Scudeller L, Grassi R. Joint effusion of the knee: potentialities and limitations of ultrasonography. J Ultrasound. 2015;18(4):361–71.CrossRef Draghi F, Urciuoli L, Alessandrino F, Corti R, Scudeller L, Grassi R. Joint effusion of the knee: potentialities and limitations of ultrasonography. J Ultrasound. 2015;18(4):361–71.CrossRef
23.
Zurück zum Zitat Bonnefoy O, Diris B, Moinard M, Aunoble S, Diard F, Hauger O. Acute knee trauma: role of ultrasound. EurRadiol. 2006;16(11):2542–8. Bonnefoy O, Diris B, Moinard M, Aunoble S, Diard F, Hauger O. Acute knee trauma: role of ultrasound. EurRadiol. 2006;16(11):2542–8.
25.
Zurück zum Zitat Kilic TY, Yesilaras M, Atilla OD, Turgut A. The accuracy of point-of-care ultrasound as a diagnostic tool for patella fractures. Am J Emerg Med. 2016;34(8):1576–8.CrossRef Kilic TY, Yesilaras M, Atilla OD, Turgut A. The accuracy of point-of-care ultrasound as a diagnostic tool for patella fractures. Am J Emerg Med. 2016;34(8):1576–8.CrossRef
26.
Zurück zum Zitat Bozorgi F, Shayesteh AM, Montazer SH, Chabra A, Heidari SF, Khalilian A. Ability of ultrasonography in detection of different extremity bone fractures; a case series study. Emerg (Tehran). 2017;5(1):e15 (PMID: 28286822; PMCID: PMC5325883.). Bozorgi F, Shayesteh AM, Montazer SH, Chabra A, Heidari SF, Khalilian A. Ability of ultrasonography in detection of different extremity bone fractures; a case series study. Emerg (Tehran). 2017;5(1):e15 (PMID: 28286822; PMCID: PMC5325883.).
27.
Zurück zum Zitat Bozorgia F, Azarb MS, Montazera SH, Heidaria SF, Khalilianc A. Accuracy of ultrasound for diagnosis of femur bone fractures in traumatic patients. ͘J Clin Exp Orthop. 2017;3:27. Bozorgia F, Azarb MS, Montazera SH, Heidaria SF, Khalilianc A. Accuracy of ultrasound for diagnosis of femur bone fractures in traumatic patients. ͘J Clin Exp Orthop. 2017;3:27.
28.
Zurück zum Zitat Etli I, Kozaci N, Avci M, Karakoyun OF. Comparison of the diagnostic accuracy of X-ray and computed tomography in patients with wrist. Injury. 2020;51(3):651–5.CrossRef Etli I, Kozaci N, Avci M, Karakoyun OF. Comparison of the diagnostic accuracy of X-ray and computed tomography in patients with wrist. Injury. 2020;51(3):651–5.CrossRef
Metadaten
Titel
Comparison of diagnostic accuracy of point-of-care ultrasonography and X-ray of bony injuries of the knee
verfasst von
Nalan Kozaci
Mustafa Avci
Serkan Yuksel
Eda Donertas
Adeviye Karaca
Gizem Gonullu
Ibrahim Etli
Publikationsdatum
02.02.2022
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 4/2022
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-022-01883-5

Weitere Artikel der Ausgabe 4/2022

European Journal of Trauma and Emergency Surgery 4/2022 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.