Skip to main content
Erschienen in: European Journal of Trauma and Emergency Surgery 6/2021

01.11.2020 | Review Article

Comparison of the feasibility of 3D printing technology in the treatment of pelvic fractures: a systematic review and meta-analysis of randomized controlled trials and prospective comparative studies

verfasst von: Jinwu Wang, Xingyu Wang, Bingzhang Wang, Linzhen Xie, Wenhao Zheng, Hua Chen, Leyi Cai

Erschienen in: European Journal of Trauma and Emergency Surgery | Ausgabe 6/2021

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The objective of this meta-analysis was to assess the influence of 3D printing technology on the open reduction and internal fixation (ORIF) of pelvic fractures from current randomized controlled trials and prospective comparative studies.

Methods

In this meta-analysis, we conducted electronic searches of Pubmed, Embase, Cochrane library, Web of Science and CNKI up to February 2020. We collected clinical controlled trials using 3D printing-assisted surgery and traditional techniques to assist in pelvic fractures, evaluating the quality of the included studies and extracting data. The data of operation time, blood loss, follow-up function (Majeed function score), quality of fracture reduction (Matta score) and complications (infection, screw loosening, pelvic instability, venous thromboembolism, sacral nerve injury) were extracted. Stata 12.0 software was used for our meta-analysis.

Results

Five RCTs and 2 prospective comparative studies met our inclusion criteria with 174 patients in the 3D printing group and 174 patients in the conventional group. There were significant differences in operation time [SMD = − 2.03], intraoperative blood loss [SMD = − 1.66] and postoperative complications [RR = 0.17] between the 3D group and conventional group. And the excellent and good rate of pelvic fracture reduction in the 3D group [RR = 1.32], the excellent and good rate of pelvic function [RR = 1.29] was superior to the conventional group.

Conclusions

The 3D group showed shorter operation time, less intraoperative blood loss, less complications, better quality of fracture reduction and fast function recovery. Therefore, compared with conventional ORIF, ORIF assisted by 3D printing technology should be a more appropriate treatment of pelvic fractures.
Literatur
1.
Zurück zum Zitat Tile M. Acute pelvic fractures: I. Causation and classification. J Am Acad Orthop Surg. 1996;4(3):143–51.PubMed Tile M. Acute pelvic fractures: I. Causation and classification. J Am Acad Orthop Surg. 1996;4(3):143–51.PubMed
2.
Zurück zum Zitat Breuil V, Roux CH, Carle GF. Pelvic fractures: epidemiology, consequences, and medical management. Curr Opin Rheumatol. 2016;28(4):442–7.CrossRef Breuil V, Roux CH, Carle GF. Pelvic fractures: epidemiology, consequences, and medical management. Curr Opin Rheumatol. 2016;28(4):442–7.CrossRef
3.
Zurück zum Zitat Abrassart S, Stern R, Peter R. Unstable pelvic ring injury with hemodynamic instability: what seems the best procedure choice and sequence in the initial management? Orthop Traumatol Surg Res. 2013;99(2):175–82.PubMedCrossRef Abrassart S, Stern R, Peter R. Unstable pelvic ring injury with hemodynamic instability: what seems the best procedure choice and sequence in the initial management? Orthop Traumatol Surg Res. 2013;99(2):175–82.PubMedCrossRef
4.
Zurück zum Zitat Sheth R, Balesh ER, Zhang YS, Hirsch JA, Khademhosseini A, Oklu R. Three-dimensional printing: an enabling technology for IR. J Vasc Interv Radiol. 2016;27(6):859–65.PubMedCrossRef Sheth R, Balesh ER, Zhang YS, Hirsch JA, Khademhosseini A, Oklu R. Three-dimensional printing: an enabling technology for IR. J Vasc Interv Radiol. 2016;27(6):859–65.PubMedCrossRef
5.
Zurück zum Zitat Mao ZG, Jiang YW, Mao JH, Tong PJ. Application of 3D printing technology in the complex acetabular prosthesis revision surgery:a case report. Zhongguo Gu Shang. 2016;29(11):1058–60.PubMed Mao ZG, Jiang YW, Mao JH, Tong PJ. Application of 3D printing technology in the complex acetabular prosthesis revision surgery:a case report. Zhongguo Gu Shang. 2016;29(11):1058–60.PubMed
6.
Zurück zum Zitat Moher D, Liberati A, Tetzlaff J, Altman DG, Group P. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6(7):e1000097.CrossRef Moher D, Liberati A, Tetzlaff J, Altman DG, Group P. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6(7):e1000097.CrossRef
7.
Zurück zum Zitat Cumpston M, Li T, Page MJ, Chandler J, Welch VA, Higgins JP, et al. Updated guidance for trusted systematic reviews a new edition of the cochrane handbook for systematic reviews of interventions. Cochrane Database Syst Rev. 2019;10:ED000142.PubMed Cumpston M, Li T, Page MJ, Chandler J, Welch VA, Higgins JP, et al. Updated guidance for trusted systematic reviews a new edition of the cochrane handbook for systematic reviews of interventions. Cochrane Database Syst Rev. 2019;10:ED000142.PubMed
8.
Zurück zum Zitat Chuling F, Hui H, Zuojun X. The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomized studies. Syst Rev Meta PloS one. 2016;13(12):e0208725. Chuling F, Hui H, Zuojun X. The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomized studies. Syst Rev Meta PloS one. 2016;13(12):e0208725.
9.
Zurück zum Zitat Lin L. Feasibility study of 3D printing technology in the treatment of complex pelvic fractures. Modern Hosp. 2018;18(6):883–90. Lin L. Feasibility study of 3D printing technology in the treatment of complex pelvic fractures. Modern Hosp. 2018;18(6):883–90.
10.
Zurück zum Zitat Chen X, Chen B, Li T, Shi S, Zhu Y. Clinical analysis of 3D printing technique assisted anterior minimally invasive approach in the treatment of unstable pelvic fracture. Progress Modern Biomed. 2018;018(12):2325–8. Chen X, Chen B, Li T, Shi S, Zhu Y. Clinical analysis of 3D printing technique assisted anterior minimally invasive approach in the treatment of unstable pelvic fracture. Progress Modern Biomed. 2018;018(12):2325–8.
11.
Zurück zum Zitat Lan XY, Zhang ZP, Dong YE, Liao XQ, Orthopedics DO. Application value of 3D printing technique in pelvic fracture repair. China Modern Med. 2018;1:4–7. Lan XY, Zhang ZP, Dong YE, Liao XQ, Orthopedics DO. Application value of 3D printing technique in pelvic fracture repair. China Modern Med. 2018;1:4–7.
12.
Zurück zum Zitat Wang Z. Application value of 3D printing technique in patients with freshly closed pelvic fractur. Internat Med Health Guidance News. 2017;23(23):3695–8. Wang Z. Application value of 3D printing technique in patients with freshly closed pelvic fractur. Internat Med Health Guidance News. 2017;23(23):3695–8.
13.
Zurück zum Zitat Li M, Chen R, Zhong H. Application of 3D printing in digital design of pelvic fracture. Med Equip. 2018;31(17):1–2. Li M, Chen R, Zhong H. Application of 3D printing in digital design of pelvic fracture. Med Equip. 2018;31(17):1–2.
14.
Zurück zum Zitat Fan L, He B, Wang B, Qin H, Wang Y. Appficafion of 3D printing technology and individualized treatment in pelvic fracture. Orthop Biomech Mater Clin Study. 2018;15(2):44–7. Fan L, He B, Wang B, Qin H, Wang Y. Appficafion of 3D printing technology and individualized treatment in pelvic fracture. Orthop Biomech Mater Clin Study. 2018;15(2):44–7.
15.
Zurück zum Zitat Huang L, Wu P. The application and curative effect of 3D printing in pelvic fracture surgery. Health Guide. 2017;7:176. Huang L, Wu P. The application and curative effect of 3D printing in pelvic fracture surgery. Health Guide. 2017;7:176.
16.
Zurück zum Zitat Majeed SA. Grading the outcome of pelvic fractures. J Bone Jt Surg Br. 1989;71(2):304–6.CrossRef Majeed SA. Grading the outcome of pelvic fractures. J Bone Jt Surg Br. 1989;71(2):304–6.CrossRef
17.
Zurück zum Zitat Matta JM, Tornetta P 3rd. Internal fixation of unstable pelvic ring injuries. Clin Orthop Relat Res. 1996;329:129–40.CrossRef Matta JM, Tornetta P 3rd. Internal fixation of unstable pelvic ring injuries. Clin Orthop Relat Res. 1996;329:129–40.CrossRef
18.
Zurück zum Zitat JM M. Operative treatment of acetabular fractures through the ilioinguinal approach. A 10-year perspective. Clin orthop related res. 1994;305:10–9. JM M. Operative treatment of acetabular fractures through the ilioinguinal approach. A 10-year perspective. Clin orthop related res. 1994;305:10–9.
19.
Zurück zum Zitat Cai L, Zhang Y, Chen C, Lou Y, Guo X, Wang J. 3D printing-based minimally invasive cannulated screw treatment of unstable pelvic fracture. J Orthop Surg Res. 2018;13(1):71.PubMedPubMedCentralCrossRef Cai L, Zhang Y, Chen C, Lou Y, Guo X, Wang J. 3D printing-based minimally invasive cannulated screw treatment of unstable pelvic fracture. J Orthop Surg Res. 2018;13(1):71.PubMedPubMedCentralCrossRef
20.
Zurück zum Zitat Li L, Gao J, Bi L, Yuan Z, Pei G. Comparison of three-dimensional printing and conventional imaging in surgical treatment of Tile C pelvic fractures: a long-term follow-up study. Int J Clin Exp Med. 2017;10(8):12433–9. Li L, Gao J, Bi L, Yuan Z, Pei G. Comparison of three-dimensional printing and conventional imaging in surgical treatment of Tile C pelvic fractures: a long-term follow-up study. Int J Clin Exp Med. 2017;10(8):12433–9.
21.
Zurück zum Zitat Hung CC, Li YT, Chou YC, Chen JE, Wu CC, Shen HC, et al. Conventional plate fixation method versus pre-operative virtual simulation and three-dimensional printing-assisted contoured plate fixation method in the treatment of anterior pelvic ring fracture. Int Orthop. 2019;43(2):425–31.PubMedCrossRef Hung CC, Li YT, Chou YC, Chen JE, Wu CC, Shen HC, et al. Conventional plate fixation method versus pre-operative virtual simulation and three-dimensional printing-assisted contoured plate fixation method in the treatment of anterior pelvic ring fracture. Int Orthop. 2019;43(2):425–31.PubMedCrossRef
22.
Zurück zum Zitat Bruyere F, Leroux C, Brunereau L, Lermusiaux P. Rapid prototyping model for percutaneous nephrolithotomy training. J Endourol. 2008;22(1):91–6.PubMedCrossRef Bruyere F, Leroux C, Brunereau L, Lermusiaux P. Rapid prototyping model for percutaneous nephrolithotomy training. J Endourol. 2008;22(1):91–6.PubMedCrossRef
23.
Zurück zum Zitat Lim CG, Campbell DI, Clucas DM. Rapid prototyping technology in orbital floor reconstruction: application in three patients. Craniomaxillofac Trauma Reconstr. 2014;7(2):143–6.PubMedPubMedCentralCrossRef Lim CG, Campbell DI, Clucas DM. Rapid prototyping technology in orbital floor reconstruction: application in three patients. Craniomaxillofac Trauma Reconstr. 2014;7(2):143–6.PubMedPubMedCentralCrossRef
24.
Zurück zum Zitat Sodian R, Schmauss D, Schmitz C, Bigdeli A, Haeberle S, Schmoeckel M, et al. 3-dimensional printing of models to create custom-made devices for coil embolization of an anastomotic leak after aortic arch replacement. Ann Thorac Surg. 2009;88(3):974–8.PubMedCrossRef Sodian R, Schmauss D, Schmitz C, Bigdeli A, Haeberle S, Schmoeckel M, et al. 3-dimensional printing of models to create custom-made devices for coil embolization of an anastomotic leak after aortic arch replacement. Ann Thorac Surg. 2009;88(3):974–8.PubMedCrossRef
25.
Zurück zum Zitat Schievano S, Migliavacca F, Coats L, Khambadkone S, Carminati M, Wilson N, et al. Percutaneous pulmonary valve implantation based on rapid prototyping of right ventricular outflow tract and pulmonary trunk from MR data. Radiology. 2007;242(2):490–7.PubMedCrossRef Schievano S, Migliavacca F, Coats L, Khambadkone S, Carminati M, Wilson N, et al. Percutaneous pulmonary valve implantation based on rapid prototyping of right ventricular outflow tract and pulmonary trunk from MR data. Radiology. 2007;242(2):490–7.PubMedCrossRef
26.
Zurück zum Zitat Mottl-Link S, Hubler M, Kuhne T, Rietdorf U, Krueger JJ, Schnackenburg B, et al. Physical models aiding in complex congenital heart surgery. Ann Thorac Surg. 2008;86(1):273–7.PubMedCrossRef Mottl-Link S, Hubler M, Kuhne T, Rietdorf U, Krueger JJ, Schnackenburg B, et al. Physical models aiding in complex congenital heart surgery. Ann Thorac Surg. 2008;86(1):273–7.PubMedCrossRef
27.
Zurück zum Zitat Toso F, Zuiani C, Vergendo M, Salvo I, Robiony M, Politi M, et al. Usefulness of computed tomography in pre-surgical evaluation of maxillo-facial pathology with rapid prototyping and surgical pre-planning by virtual reality. Radiol Med. 2005;110(5–6):665–75.PubMed Toso F, Zuiani C, Vergendo M, Salvo I, Robiony M, Politi M, et al. Usefulness of computed tomography in pre-surgical evaluation of maxillo-facial pathology with rapid prototyping and surgical pre-planning by virtual reality. Radiol Med. 2005;110(5–6):665–75.PubMed
28.
Zurück zum Zitat Chow LK, Cheung LK. The usefulness of stereomodels in maxillofacial surgical management. J Oral Maxillofac Surg. 2007;65(11):2260–8.PubMedCrossRef Chow LK, Cheung LK. The usefulness of stereomodels in maxillofacial surgical management. J Oral Maxillofac Surg. 2007;65(11):2260–8.PubMedCrossRef
29.
Zurück zum Zitat Zhou LB, Shang HT, He LS, Bo B, Liu GC, Liu YP, et al. Accurate reconstruction of discontinuous mandible using a reverse engineering/computer-aided design/rapid prototyping technique: a preliminary clinical study. J Oral Maxillofac Surg. 2010;68(9):2115–21.PubMedCrossRef Zhou LB, Shang HT, He LS, Bo B, Liu GC, Liu YP, et al. Accurate reconstruction of discontinuous mandible using a reverse engineering/computer-aided design/rapid prototyping technique: a preliminary clinical study. J Oral Maxillofac Surg. 2010;68(9):2115–21.PubMedCrossRef
30.
Zurück zum Zitat Parchi PD, Ferrari V, Piolanti N, Andreani L, Condino S, Evangelisti G, et al. Computer tomography prototyping and virtual procedure simulation in difficult cases of hip replacement surgery. Surg Technol Int. 2013;23:228–34.PubMed Parchi PD, Ferrari V, Piolanti N, Andreani L, Condino S, Evangelisti G, et al. Computer tomography prototyping and virtual procedure simulation in difficult cases of hip replacement surgery. Surg Technol Int. 2013;23:228–34.PubMed
31.
Zurück zum Zitat Jeong HS, Park KJ, Kil KM, Chong S, Eun HJ, Lee TS, et al. Minimally invasive plate osteosynthesis using 3D printing for shaft fractures of clavicles: technical note. Arch Orthop Trauma Surg. 2014;134(11):1551–5.PubMedCrossRef Jeong HS, Park KJ, Kil KM, Chong S, Eun HJ, Lee TS, et al. Minimally invasive plate osteosynthesis using 3D printing for shaft fractures of clavicles: technical note. Arch Orthop Trauma Surg. 2014;134(11):1551–5.PubMedCrossRef
32.
Zurück zum Zitat Murray DJ, Edwards G, Mainprize JG, Antonyshyn O. Advanced technology in the management of fibrous dysplasia. J Plast Reconstr Aesthet Surg. 2008;61(8):906–16.PubMedCrossRef Murray DJ, Edwards G, Mainprize JG, Antonyshyn O. Advanced technology in the management of fibrous dysplasia. J Plast Reconstr Aesthet Surg. 2008;61(8):906–16.PubMedCrossRef
33.
Zurück zum Zitat Ciocca L, Fantini M, De Crescenzio F, Persiani F, Scotti R. Computer-aided design and manufacturing construction of a surgical template for craniofacial implant positioning to support a definitive nasal prosthesis. Clin Oral Implants Res. 2011;22(8):850–6.PubMedCrossRef Ciocca L, Fantini M, De Crescenzio F, Persiani F, Scotti R. Computer-aided design and manufacturing construction of a surgical template for craniofacial implant positioning to support a definitive nasal prosthesis. Clin Oral Implants Res. 2011;22(8):850–6.PubMedCrossRef
34.
Zurück zum Zitat Jirman R, Horak Z, Mazanek J, Reznicek J. Individual replacement of the frontal bone defect: case report. Prague Med Rep. 2009;110(1):79–84.PubMed Jirman R, Horak Z, Mazanek J, Reznicek J. Individual replacement of the frontal bone defect: case report. Prague Med Rep. 2009;110(1):79–84.PubMed
Metadaten
Titel
Comparison of the feasibility of 3D printing technology in the treatment of pelvic fractures: a systematic review and meta-analysis of randomized controlled trials and prospective comparative studies
verfasst von
Jinwu Wang
Xingyu Wang
Bingzhang Wang
Linzhen Xie
Wenhao Zheng
Hua Chen
Leyi Cai
Publikationsdatum
01.11.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 6/2021
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-020-01532-9

Weitere Artikel der Ausgabe 6/2021

European Journal of Trauma and Emergency Surgery 6/2021 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.