Skip to main content
Erschienen in: Pediatric Radiology 10/2015

01.09.2015 | Original Article

Contrast-enhanced voiding urosonography: in vitro evaluation of a second-generation ultrasound contrast agent for in vivo optimization

verfasst von: Susan J. Back, J. Christopher Edgar, Douglas A. Canning, Kassa Darge

Erschienen in: Pediatric Radiology | Ausgabe 10/2015

Einloggen, um Zugang zu erhalten

Abstract

Background

Pediatric contrast-enhanced ultrasound (CEUS) is primarily performed outside the United States where a track record for safety in intravenous and intravesical applications has been established. Contrast-enhanced voiding urosonography (ceVUS) has also been shown to have a much higher rate of vesicoureteral reflux detection compared to voiding cystourethrography. US contrast agents available in the United States differ from those abroad. Optison® (GE Healthcare, Princeton, NJ) is such an US contrast agent. While Optison® has similar characteristics to other second-generation agents, it has never been used for ceVUS. In vitro optimization of dose and imaging parameters as well as assessment of contrast visualization when delivered in conditions similar to ceVUS are necessary starting points prior to in vivo applications.

Objective

To optimize the intravesical use of Optison® in vitro for ceVUS before its use in pediatric studies.

Materials and methods

The experimental design simulated intravesical use. Using 9- and 12-MHz linear transducers, we scanned 20-mL syringes varying mechanical index, US contrast agent concentration (0.25%, 0.5%, 1.0%), solvent (saline, urine, radiographic contrast agent) and time out of refrigeration. We evaluated mechanical index settings and contrast duration, optimized the contrast dose, measured the effect of urine and radiographic contrast agent, and the impact of length of time of contrast outside of the refrigerator on US contrast appearance. We scanned 50-ml saline bags to assess the appearance and duration of US contrast with different delivery systems (injection vs. infusion).

Results

Consistent contrast visualization was achieved at a mechanical index of 0.06-0.17 and 0.11-0.48 for the L9 and L12 MHz transducers (P < 0.01), respectively. Thus, it was necessary to increase the mechanical index for better contrast visualization of the microbubbles with a higher transducer frequency. The lowest mechanical index for earliest visible microbubble destruction was 0.21 for the 9 MHz and 0.39 for the 12 MHz (P < 0.01) transducers. The 0.5% US contrast agent volume to bladder filling was the most optimal. At this concentration, the mean time to visualize homogenous contrast was 2 min and destruction of approximately half of the microbubbles in the field of view occurred in 7.8 min using the 9-MHz transducer. During contrast infusion, the contrast dose needed to be reduced to 0.12% for maintenance of optimal visualization of microbubbles. There was no deleterious effect on the visualization of contrast in the presence of urine or radiographic contrast agent. Infusion of the US contrast agent speeded visualization of homogeneous enhancement compared with injection. Time outside refrigeration did not affect contrast performance.

Conclusion

Transducer mechanical index settings need to be optimized. A very low dose of the US contrast agent Optison® will suffice for intravesical application, i.e. 0.12% to 0.50% of the bladder filling volume. The presence of urine or radiographic contrast agent did not compromise contrast visualization. The best mode of administration is the infusion method due to fast homogenous distribution at the lowest dose of 0.12%. Leaving the US contrast agent outside the refrigerator for an hour does not affect the microbubbles.
Literatur
1.
Zurück zum Zitat Darge K (2010) Voiding urosonography with US contrast agent for the diagnosis of vesicoureteric reflux in children: an update. Pediatr Radiol 40:956–962CrossRefPubMed Darge K (2010) Voiding urosonography with US contrast agent for the diagnosis of vesicoureteric reflux in children: an update. Pediatr Radiol 40:956–962CrossRefPubMed
2.
Zurück zum Zitat Darge K (2008) Voiding urosonography with ultrasound contrast agents for the diagnosis of vesicoureteric reflux in children. I. Procedure. Pediatr Radiol 38:40–53PubMedCentralCrossRefPubMed Darge K (2008) Voiding urosonography with ultrasound contrast agents for the diagnosis of vesicoureteric reflux in children. I. Procedure. Pediatr Radiol 38:40–53PubMedCentralCrossRefPubMed
3.
Zurück zum Zitat Darge K (2008) Voiding urosonography with US contrast agents for the diagnosis of vesicoureteric reflux in children. II. Comparison with radiological examinations. Pediatr Radiol 38:54–63CrossRefPubMed Darge K (2008) Voiding urosonography with US contrast agents for the diagnosis of vesicoureteric reflux in children. II. Comparison with radiological examinations. Pediatr Radiol 38:54–63CrossRefPubMed
4.
Zurück zum Zitat McCarville MB, Kaste SC, Hoffer FA et al (2012) Contrast-enhanced sonography of malignant pediatric abdominal and pelvic solid tumors: preliminary safety and feasibility data. Pediatr Radiol 42:824–833PubMedCentralCrossRefPubMed McCarville MB, Kaste SC, Hoffer FA et al (2012) Contrast-enhanced sonography of malignant pediatric abdominal and pelvic solid tumors: preliminary safety and feasibility data. Pediatr Radiol 42:824–833PubMedCentralCrossRefPubMed
5.
Zurück zum Zitat Darge K, Papadopoulou F, Ntoulia A et al (2013) Safety of contrast-enhanced ultrasound in children for non-cardiac applications: a review by the Society for Pediatric Radiology (SPR) and the International Contrast Ultrasound Society (ICUS). Pediatr Radiol 43:1063–1073CrossRefPubMed Darge K, Papadopoulou F, Ntoulia A et al (2013) Safety of contrast-enhanced ultrasound in children for non-cardiac applications: a review by the Society for Pediatric Radiology (SPR) and the International Contrast Ultrasound Society (ICUS). Pediatr Radiol 43:1063–1073CrossRefPubMed
6.
Zurück zum Zitat Podell S, Burrascano C, Gaal M et al (1999) Physical and biochemical stability of Optison, and injectable ultrasound contrast agent. Biotechnol Appl Biochem 30:213–223PubMed Podell S, Burrascano C, Gaal M et al (1999) Physical and biochemical stability of Optison, and injectable ultrasound contrast agent. Biotechnol Appl Biochem 30:213–223PubMed
7.
Zurück zum Zitat Robrecht J, Darge K (2007) In-vitro comparison of a 1st and a 2nd generation US contrast agent for reflux diagnosis. RöFo 179:818–825PubMed Robrecht J, Darge K (2007) In-vitro comparison of a 1st and a 2nd generation US contrast agent for reflux diagnosis. RöFo 179:818–825PubMed
8.
Zurück zum Zitat Darge K, Bruchelt W, Roessling G et al (2003) Interaction of normal saline solution with ultrasound contrast medium: significant implication for sonographic diagnosis of vesicoureteral reflux. Eur Radiol 13:213–218PubMed Darge K, Bruchelt W, Roessling G et al (2003) Interaction of normal saline solution with ultrasound contrast medium: significant implication for sonographic diagnosis of vesicoureteral reflux. Eur Radiol 13:213–218PubMed
9.
Zurück zum Zitat Goddi A, Novario R, Tanzi F et al (2004) In vitro analysis of ultrasound second generation contrast agent diluted in saline solution. Radiol Med 107:569–579PubMed Goddi A, Novario R, Tanzi F et al (2004) In vitro analysis of ultrasound second generation contrast agent diluted in saline solution. Radiol Med 107:569–579PubMed
11.
Zurück zum Zitat Moir S, Marwick TH (2004) Combination of contrast with stress echocardiography: a practical guide to methods and interpretation. Cardiovasc Ultrasound 2:15PubMedCentralCrossRefPubMed Moir S, Marwick TH (2004) Combination of contrast with stress echocardiography: a practical guide to methods and interpretation. Cardiovasc Ultrasound 2:15PubMedCentralCrossRefPubMed
12.
Zurück zum Zitat Papadopoulou F, Anthopoulou A, Siomou E et al (2009) Harmonic voiding urosonography with a second generation contrast agent for the diagnosis of vesicoureteral reflux. Pediatr Radiol 39:239–244CrossRefPubMed Papadopoulou F, Anthopoulou A, Siomou E et al (2009) Harmonic voiding urosonography with a second generation contrast agent for the diagnosis of vesicoureteral reflux. Pediatr Radiol 39:239–244CrossRefPubMed
13.
Zurück zum Zitat Duran C, del Riego J, Riera L et al (2012) Voiding urosonography including urethrosonography: high-quality examinations with an optimized procedure using a second-generation US contrast agent. Pediatr Radiol 42:660–667CrossRefPubMed Duran C, del Riego J, Riera L et al (2012) Voiding urosonography including urethrosonography: high-quality examinations with an optimized procedure using a second-generation US contrast agent. Pediatr Radiol 42:660–667CrossRefPubMed
15.
Zurück zum Zitat Duran C, Valera A, Alguersuari A et al (2009) Voiding urosonography: the study of the urethra is no longer a limitation of the technique. Pediatr Radiol 39:124–131CrossRefPubMed Duran C, Valera A, Alguersuari A et al (2009) Voiding urosonography: the study of the urethra is no longer a limitation of the technique. Pediatr Radiol 39:124–131CrossRefPubMed
16.
Zurück zum Zitat Papadopoulou F, Evangelou E, Riccabona M et al. (2012) Contrast-enhanced voiding urosonography for diagnosis of vesicoureteric reflux in comparison to conventional methods: a meta-analysis. ECR Book of Abstracts, Insights Imaging 3:SS 1712, B-0860 Papadopoulou F, Evangelou E, Riccabona M et al. (2012) Contrast-enhanced voiding urosonography for diagnosis of vesicoureteric reflux in comparison to conventional methods: a meta-analysis. ECR Book of Abstracts, Insights Imaging 3:SS 1712, B-0860
17.
Zurück zum Zitat Kis E, Nyitrai A, Varkonyi I et al (2010) Voiding urosonography with second-generation contrast agent versus voiding cystourethrography. Pediatr Nephrol 25:2289–2293CrossRefPubMed Kis E, Nyitrai A, Varkonyi I et al (2010) Voiding urosonography with second-generation contrast agent versus voiding cystourethrography. Pediatr Nephrol 25:2289–2293CrossRefPubMed
18.
Zurück zum Zitat Riccabona M (2012) Application of a second-generation US contrast agent in infants and children—a European questionnaire-based survey. Pediatr Radiol 42:1471–1480CrossRefPubMed Riccabona M (2012) Application of a second-generation US contrast agent in infants and children—a European questionnaire-based survey. Pediatr Radiol 42:1471–1480CrossRefPubMed
19.
Zurück zum Zitat Weskott HP (ed) (2011) Contrast enhanced ultrasound. Unimed, Bremen Weskott HP (ed) (2011) Contrast enhanced ultrasound. Unimed, Bremen
Metadaten
Titel
Contrast-enhanced voiding urosonography: in vitro evaluation of a second-generation ultrasound contrast agent for in vivo optimization
verfasst von
Susan J. Back
J. Christopher Edgar
Douglas A. Canning
Kassa Darge
Publikationsdatum
01.09.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Pediatric Radiology / Ausgabe 10/2015
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-015-3355-3

Weitere Artikel der Ausgabe 10/2015

Pediatric Radiology 10/2015 Zur Ausgabe

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.