Skip to main content
Erschienen in: Japanese Journal of Radiology 6/2021

28.01.2021 | Original Article

Could both intrinsic and extrinsic iodine be successfully suppressed on virtual non-contrast CT images for detecting thyroid calcification?

verfasst von: Arim Park, Young Hen Lee, Hyung Suk Seo

Erschienen in: Japanese Journal of Radiology | Ausgabe 6/2021

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Although virtual non-contrast (VNC) successfully removes iodinated contrast, uncertainty exists regarding the feasibility of VNC to suppress iodine for detecting thyroid calcification. Therefore, we evaluated whether both intrinsic and extrinsic iodine attenuation were suppressed on VNC images.

Material and methods

We enrolled 128 patients (male: female 17:111; age 48.0 ± 10.4 years) who underwent dual-layer dual-energy CT (DL-DECT) examination before their thyroid cancer surgeries. Two additional sets of VNC (VNCu, VNCc) images were retrospectively generated from their true unenhanced (TUE) and true contrast-enhanced (TCE) series. We compared CT attenuation values measured on the VNCu and VNCc images by drawing identical regions of interest encompassing thyroid parenchyma, then subjectively determined the concordance of calcification.

Results

Although CT attenuation discrepancies between the VNCu and VNCc were significant (2.0 ± 5.7HU, p < 0.001),61.7%, 89.1%, and 100.0% of all measurements were < 5HU, < 10HU, and < 15HU. Based on Bland–Altman analysis, the limits of agreement were − 9.2HU and 13.2HU, whereas the proportional differences were small for VNC images generated from both TUE and TCE images. There was no discordance between two VNC image sets in detecting thyroid calcification.

Conclusions

VNC technique could be a feasible method to suppress both intrinsic and extrinsically administered iodine for detecting thyroid calcification
Literatur
1.
Zurück zum Zitat McCollough CH, Leng S, Yu L, Fletcher JG. Dual- and multi-energy CT: principles, technical approaches, and clinical applications. Radiology. 2015;276(3):637–53.CrossRef McCollough CH, Leng S, Yu L, Fletcher JG. Dual- and multi-energy CT: principles, technical approaches, and clinical applications. Radiology. 2015;276(3):637–53.CrossRef
2.
Zurück zum Zitat Krauss B. Dual-energy computed tomography: technology and challenges. Radiol Clin N Am. 2018;56(4):497–506.CrossRef Krauss B. Dual-energy computed tomography: technology and challenges. Radiol Clin N Am. 2018;56(4):497–506.CrossRef
3.
Zurück zum Zitat Wolman DN, Patel BP, Wintermark M, Heit JJ. Dual-energy computed tomography applications in neurointervention. J Comput Assist Tomogr. 2018;42(6):831–9.CrossRef Wolman DN, Patel BP, Wintermark M, Heit JJ. Dual-energy computed tomography applications in neurointervention. J Comput Assist Tomogr. 2018;42(6):831–9.CrossRef
4.
Zurück zum Zitat Megibow AJ, Kambadakone A, Ananthakrishnan L. Dual-Energy computed tomography: image acquisition, processing, and workflow. Radiol Clin N Am. 2018;56(4):507–20.CrossRef Megibow AJ, Kambadakone A, Ananthakrishnan L. Dual-Energy computed tomography: image acquisition, processing, and workflow. Radiol Clin N Am. 2018;56(4):507–20.CrossRef
5.
Zurück zum Zitat Ozguner O, Dhanantwari A, Halliburton S, Wen G, Utrup S, Jordan D. Objective image characterization of a spectral CT scanner with dual-layer detector. Phys Med Biol. 2018;63(2):025027.CrossRef Ozguner O, Dhanantwari A, Halliburton S, Wen G, Utrup S, Jordan D. Objective image characterization of a spectral CT scanner with dual-layer detector. Phys Med Biol. 2018;63(2):025027.CrossRef
6.
Zurück zum Zitat Grosse Hokamp N, Maintz D, Shapira N, Chang H, Noel PB. Technical background of a novel detector-based approach to dual-energy computed tomography. Diagn Interv Radiol (Ank Turk). 2020;26(1):68–71.CrossRef Grosse Hokamp N, Maintz D, Shapira N, Chang H, Noel PB. Technical background of a novel detector-based approach to dual-energy computed tomography. Diagn Interv Radiol (Ank Turk). 2020;26(1):68–71.CrossRef
7.
Zurück zum Zitat Hua CH, Shapira N, Merchant TE, Klahr P, Yagil Y. Accuracy of electron density, effective atomic number, and iodine concentration determination with a dual-layer dual-energy computed tomography system. Med Phys. 2018;45(6):2486–97.CrossRef Hua CH, Shapira N, Merchant TE, Klahr P, Yagil Y. Accuracy of electron density, effective atomic number, and iodine concentration determination with a dual-layer dual-energy computed tomography system. Med Phys. 2018;45(6):2486–97.CrossRef
8.
Zurück zum Zitat Durieux P, Gevenois PA, Muylem AV, Howarth N, Keyzer C. Abdominal attenuation values on virtual and true unenhanced images obtained with third-generation dual-source dual-energy CT. AJR Am J Roentgenol. 2018;210(5):1042–58.CrossRef Durieux P, Gevenois PA, Muylem AV, Howarth N, Keyzer C. Abdominal attenuation values on virtual and true unenhanced images obtained with third-generation dual-source dual-energy CT. AJR Am J Roentgenol. 2018;210(5):1042–58.CrossRef
9.
Zurück zum Zitat Chai Y, Xing J, Gao J, Lv P, Liang P, Liu J, Guo Y. Feasibility of virtual nonenhanced images derived from single-source fast kVp-switching dual-energy CT in evaluating gastric tumors. Eur J Radiol. 2016;85(2):366–72.CrossRef Chai Y, Xing J, Gao J, Lv P, Liang P, Liu J, Guo Y. Feasibility of virtual nonenhanced images derived from single-source fast kVp-switching dual-energy CT in evaluating gastric tumors. Eur J Radiol. 2016;85(2):366–72.CrossRef
10.
Zurück zum Zitat Sun H, Hou XY, Xue HD, Li XG, Jin ZY, Qian JM, Yu JC, Zhu HD. Dual-source dual-energy CT angiography with virtual non-enhanced images and iodine map for active gastrointestinal bleeding: image quality, radiation dose and diagnostic performance. Eur J Radiol. 2015;84(5):884–91.CrossRef Sun H, Hou XY, Xue HD, Li XG, Jin ZY, Qian JM, Yu JC, Zhu HD. Dual-source dual-energy CT angiography with virtual non-enhanced images and iodine map for active gastrointestinal bleeding: image quality, radiation dose and diagnostic performance. Eur J Radiol. 2015;84(5):884–91.CrossRef
11.
Zurück zum Zitat Connolly MJ, McInnes MDF, El-Khodary M, McGrath TA, Schieda N. Diagnostic accuracy of virtual non-contrast enhanced dual-energy CT for diagnosis of adrenal adenoma: a systematic review and meta-analysis. Eur Radiol. 2017;27(10):4324–35.CrossRef Connolly MJ, McInnes MDF, El-Khodary M, McGrath TA, Schieda N. Diagnostic accuracy of virtual non-contrast enhanced dual-energy CT for diagnosis of adrenal adenoma: a systematic review and meta-analysis. Eur Radiol. 2017;27(10):4324–35.CrossRef
12.
Zurück zum Zitat Walter SS, Schneeweiss S, Maurer M, Kraus MS, Wichmann JL, Bongers MN, Lescan M, Bamberg F, Othman AE. Virtual non-enhanced dual-energy CT reconstruction may replace true non-enhanced CT scans in the setting of suspected active hemorrhage. Eur J Radiol. 2018;109:218–22.CrossRef Walter SS, Schneeweiss S, Maurer M, Kraus MS, Wichmann JL, Bongers MN, Lescan M, Bamberg F, Othman AE. Virtual non-enhanced dual-energy CT reconstruction may replace true non-enhanced CT scans in the setting of suspected active hemorrhage. Eur J Radiol. 2018;109:218–22.CrossRef
13.
Zurück zum Zitat Bae JS, Lee DH, Joo I, Jeon SK, Han JK. Utilization of virtual non-contrast images derived from dual-energy CT in evaluation of biliary stone disease: virtual non-contrast image can replace true non-contrast image regarding biliary stone detection. Eur J Radiol. 2019;116:34–40.CrossRef Bae JS, Lee DH, Joo I, Jeon SK, Han JK. Utilization of virtual non-contrast images derived from dual-energy CT in evaluation of biliary stone disease: virtual non-contrast image can replace true non-contrast image regarding biliary stone detection. Eur J Radiol. 2019;116:34–40.CrossRef
14.
Zurück zum Zitat Lee HA, Lee YH, Yoon KH, Bang DH, Park DE. Comparison of virtual unenhanced images derived from dual-energy CT with true unenhanced images in evaluation of gallstone disease. AJR Am J Roentgenol. 2016;206(1):74–80.CrossRef Lee HA, Lee YH, Yoon KH, Bang DH, Park DE. Comparison of virtual unenhanced images derived from dual-energy CT with true unenhanced images in evaluation of gallstone disease. AJR Am J Roentgenol. 2016;206(1):74–80.CrossRef
15.
Zurück zum Zitat Song I, Yi JG, Park JH, Kim SM, Lee KS, Chung MJ. Virtual non-contrast CT using dual-energy spectral CT: feasibility of coronary artery calcium scoring. Korean J Radiol. 2016;17(3):321–9.CrossRef Song I, Yi JG, Park JH, Kim SM, Lee KS, Chung MJ. Virtual non-contrast CT using dual-energy spectral CT: feasibility of coronary artery calcium scoring. Korean J Radiol. 2016;17(3):321–9.CrossRef
16.
Zurück zum Zitat Yoo SY, Kim Y, Cho HH, Choi MJ, Shim SS, Lee JK, Baek SY. Dual-energy CT in the assessment of mediastinal lymph nodes: comparative study of virtual non-contrast and true non-contrast images. Korean J Radiol. 2013;14(3):532–9.CrossRef Yoo SY, Kim Y, Cho HH, Choi MJ, Shim SS, Lee JK, Baek SY. Dual-energy CT in the assessment of mediastinal lymph nodes: comparative study of virtual non-contrast and true non-contrast images. Korean J Radiol. 2013;14(3):532–9.CrossRef
17.
Zurück zum Zitat Khoo ML, Asa SL, Witterick IJ, Freeman JL. Thyroid calcification and its association with thyroid carcinoma. Head Neck. 2002;24(7):651–5.CrossRef Khoo ML, Asa SL, Witterick IJ, Freeman JL. Thyroid calcification and its association with thyroid carcinoma. Head Neck. 2002;24(7):651–5.CrossRef
18.
Zurück zum Zitat Kim BK, Choi YS, Kwon HJ, Lee JS, Heo JJ, Han YJ, Park YH, Kim JH. Relationship between patterns of calcification in thyroid nodules and histopathologic findings. Endocr J. 2013;60(2):155–60.CrossRef Kim BK, Choi YS, Kwon HJ, Lee JS, Heo JJ, Han YJ, Park YH, Kim JH. Relationship between patterns of calcification in thyroid nodules and histopathologic findings. Endocr J. 2013;60(2):155–60.CrossRef
19.
Zurück zum Zitat Wu CW, Dionigi G, Lee KW, Hsiao PJ, Paul Shin MC, Tsai KB, Chiang FY. Calcifications in thyroid nodules identified on preoperative computed tomography: patterns and clinical significance. Surgery. 2012;151(3):464–70.CrossRef Wu CW, Dionigi G, Lee KW, Hsiao PJ, Paul Shin MC, Tsai KB, Chiang FY. Calcifications in thyroid nodules identified on preoperative computed tomography: patterns and clinical significance. Surgery. 2012;151(3):464–70.CrossRef
20.
Zurück zum Zitat Yoon DY, Chang SK, Choi CS, Yun EJ, Seo YL, Nam ES, Cho SJ, Rho YS, Ahn HY. The prevalence and significance of incidental thyroid nodules identified on computed tomography. J Comput Assist Tomogr. 2008;32(5):810–5.CrossRef Yoon DY, Chang SK, Choi CS, Yun EJ, Seo YL, Nam ES, Cho SJ, Rho YS, Ahn HY. The prevalence and significance of incidental thyroid nodules identified on computed tomography. J Comput Assist Tomogr. 2008;32(5):810–5.CrossRef
21.
Zurück zum Zitat Ahad F, Ganie SA. Iodine, Iodine metabolism and Iodine deficiency disorders revisited. Indian J Endocrinol Metab. 2010;14(1):13–7.PubMedPubMedCentral Ahad F, Ganie SA. Iodine, Iodine metabolism and Iodine deficiency disorders revisited. Indian J Endocrinol Metab. 2010;14(1):13–7.PubMedPubMedCentral
22.
Zurück zum Zitat Bin Saeedan M, Aljohani IM, Khushaim AO, Bukhari SQ, Elnaas ST. Thyroid computed tomography imaging: pictorial review of variable pathologies. Insights Imaging. 2016;7(4):601–17.CrossRef Bin Saeedan M, Aljohani IM, Khushaim AO, Bukhari SQ, Elnaas ST. Thyroid computed tomography imaging: pictorial review of variable pathologies. Insights Imaging. 2016;7(4):601–17.CrossRef
23.
Zurück zum Zitat Iida Y, Konishi J, Harioka T, Misaki T, Endo K, Torizuka K. Thyroid CT number and its relationship to iodine concentration. Radiology. 1983;147(3):793–5.CrossRef Iida Y, Konishi J, Harioka T, Misaki T, Endo K, Torizuka K. Thyroid CT number and its relationship to iodine concentration. Radiology. 1983;147(3):793–5.CrossRef
24.
Zurück zum Zitat Cooper DS, Ladenson PW. Chapter 7. The thyroid gland. In: Gardner DG, Shoback D, editors. New York Greenspan’s basic & clinical endocrinology, 9edn. New York: The McGraw-Hill Companies; 2011. Cooper DS, Ladenson PW. Chapter 7. The thyroid gland. In: Gardner DG, Shoback D, editors. New York Greenspan’s basic & clinical endocrinology, 9edn. New York: The McGraw-Hill Companies; 2011.
25.
Zurück zum Zitat Kim E, Park JS, Son KR, Kim JH, Jeon SJ, Na DG. Preoperative diagnosis of cervical metastatic lymph nodes in papillary thyroid carcinoma: comparison of ultrasound, computed tomography, and combined ultrasound with computed tomography. Thyroid. 2008;18(4):411–8.CrossRef Kim E, Park JS, Son KR, Kim JH, Jeon SJ, Na DG. Preoperative diagnosis of cervical metastatic lymph nodes in papillary thyroid carcinoma: comparison of ultrasound, computed tomography, and combined ultrasound with computed tomography. Thyroid. 2008;18(4):411–8.CrossRef
26.
Zurück zum Zitat Lee Y, Kim JH, Baek JH, Jung SL, Park SW, Kim J, Yun TJ, Ha EJ, Lee KE, Kwon SY, et al. Value of CT added to ultrasonography for the diagnosis of lymph node metastasis in patients with thyroid cancer. Head Neck. 2018;40(10):2137–48.CrossRef Lee Y, Kim JH, Baek JH, Jung SL, Park SW, Kim J, Yun TJ, Ha EJ, Lee KE, Kwon SY, et al. Value of CT added to ultrasonography for the diagnosis of lymph node metastasis in patients with thyroid cancer. Head Neck. 2018;40(10):2137–48.CrossRef
27.
Zurück zum Zitat Lee YH, Seo HS, Suh SI, Ryoo I, You SH, Son KR, Kwon SY, Son GS, Yang KS. Feasibility study of a contrast-enhanced multi-detector CT (64 channels) protocol for papillary thyroid carcinoma: the influence of different scan delays on tumor conspicuity. Thyroid. 2016;26(5):726–33.CrossRef Lee YH, Seo HS, Suh SI, Ryoo I, You SH, Son KR, Kwon SY, Son GS, Yang KS. Feasibility study of a contrast-enhanced multi-detector CT (64 channels) protocol for papillary thyroid carcinoma: the influence of different scan delays on tumor conspicuity. Thyroid. 2016;26(5):726–33.CrossRef
28.
Zurück zum Zitat Lee KH, Kim DW, Baek JW, Lee YJ, Choo HJ, Cho YJ, Lee SJ, Park YM, Jung SJ, Baek HJ. Comparison of computed tomography features between follicular neoplasm and nodular hyperplasia. Cancer Imaging. 2016;16(1):31.CrossRef Lee KH, Kim DW, Baek JW, Lee YJ, Choo HJ, Cho YJ, Lee SJ, Park YM, Jung SJ, Baek HJ. Comparison of computed tomography features between follicular neoplasm and nodular hyperplasia. Cancer Imaging. 2016;16(1):31.CrossRef
29.
Zurück zum Zitat Jamali S, Michoux N, Coche E, Dragean CA. Virtual unenhanced phase with spectral dual-energy CT: Is it an alternative to conventional true unenhanced phase for abdominal tissues? Diagn Interv Imaging. 2019;100(9):503–11.CrossRef Jamali S, Michoux N, Coche E, Dragean CA. Virtual unenhanced phase with spectral dual-energy CT: Is it an alternative to conventional true unenhanced phase for abdominal tissues? Diagn Interv Imaging. 2019;100(9):503–11.CrossRef
30.
Zurück zum Zitat Laukamp KR, Ho V, Obmann VC, Herrmann K, Gupta A, Borggrefe J, Lennartz S, Grosse Hokamp N, Ramaiya N. Virtual non-contrast for evaluation of liver parenchyma and vessels: results from 25 patients using multi-phase spectral-detector CT. Acta Radiol. 2020;61(8):1143–52.CrossRef Laukamp KR, Ho V, Obmann VC, Herrmann K, Gupta A, Borggrefe J, Lennartz S, Grosse Hokamp N, Ramaiya N. Virtual non-contrast for evaluation of liver parenchyma and vessels: results from 25 patients using multi-phase spectral-detector CT. Acta Radiol. 2020;61(8):1143–52.CrossRef
31.
Zurück zum Zitat Ananthakrishnan L, Rajiah P, Ahn R, Rassouli N, Xi Y, Soesbe TC, Lewis MA, Lenkinski RE, Leyendecker JR, Abbara S. Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT. Abdom Radiol (N Y). 2017;42(3):702–9.CrossRef Ananthakrishnan L, Rajiah P, Ahn R, Rassouli N, Xi Y, Soesbe TC, Lewis MA, Lenkinski RE, Leyendecker JR, Abbara S. Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT. Abdom Radiol (N Y). 2017;42(3):702–9.CrossRef
32.
Zurück zum Zitat Sauter AP, Muenzel D, Dangelmaier J, Braren R, Pfeiffer F, Rummeny EJ, Noel PB, Fingerle AA. Dual-layer spectral computed tomography: virtual non-contrast in comparison to true non-contrast images. Eur J Radiol. 2018;104:108–14.CrossRef Sauter AP, Muenzel D, Dangelmaier J, Braren R, Pfeiffer F, Rummeny EJ, Noel PB, Fingerle AA. Dual-layer spectral computed tomography: virtual non-contrast in comparison to true non-contrast images. Eur J Radiol. 2018;104:108–14.CrossRef
33.
Zurück zum Zitat Graser A, Johnson TR, Hecht EM, Becker CR, Leidecker C, Staehler M, Stief CG, Hildebrandt H, Godoy MC, Finn ME, et al. Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images? Radiology. 2009;252(2):433–40.CrossRef Graser A, Johnson TR, Hecht EM, Becker CR, Leidecker C, Staehler M, Stief CG, Hildebrandt H, Godoy MC, Finn ME, et al. Dual-energy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images? Radiology. 2009;252(2):433–40.CrossRef
34.
Zurück zum Zitat Sahni VA, Shinagare AB, Silverman SG. Virtual unenhanced CT images acquired from dual-energy CT urography: accuracy of attenuation values and variation with contrast material phase. Clin Radiol. 2013;68(3):264–71.CrossRef Sahni VA, Shinagare AB, Silverman SG. Virtual unenhanced CT images acquired from dual-energy CT urography: accuracy of attenuation values and variation with contrast material phase. Clin Radiol. 2013;68(3):264–71.CrossRef
35.
Zurück zum Zitat Borhani AA, Kulzer M, Iranpour N, Ghodadra A, Sparrow M, Furlan A, Tublin ME. Comparison of true unenhanced and virtual unenhanced (VUE) attenuation values in abdominopelvic single-source rapid kilovoltage-switching spectral CT. Abdom Radiol (N Y). 2017;42(3):710–7.CrossRef Borhani AA, Kulzer M, Iranpour N, Ghodadra A, Sparrow M, Furlan A, Tublin ME. Comparison of true unenhanced and virtual unenhanced (VUE) attenuation values in abdominopelvic single-source rapid kilovoltage-switching spectral CT. Abdom Radiol (N Y). 2017;42(3):710–7.CrossRef
36.
Zurück zum Zitat Camlidag I. Compatibility of true and virtual unenhanced attenuation in rapid kV-switching dual energy CT. Diagn Interv Radiol (Ank Turk). 2020;26(2):95–100.CrossRef Camlidag I. Compatibility of true and virtual unenhanced attenuation in rapid kV-switching dual energy CT. Diagn Interv Radiol (Ank Turk). 2020;26(2):95–100.CrossRef
37.
Zurück zum Zitat De Cecco CN, Buffa V, Fedeli S, Luzietti M, Vallone A, Ruopoli R, Miele V, Rengo M, Paolantonio P, Maurizi Enrici M, et al. Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images. Eur Radiol. 2010;20(12):2870–5.CrossRef De Cecco CN, Buffa V, Fedeli S, Luzietti M, Vallone A, Ruopoli R, Miele V, Rengo M, Paolantonio P, Maurizi Enrici M, et al. Dual energy CT (DECT) of the liver: conventional versus virtual unenhanced images. Eur Radiol. 2010;20(12):2870–5.CrossRef
38.
Zurück zum Zitat Sellerer T, Noel PB, Patino M, Parakh A, Ehn S, Zeiter S, Holz JA, Hammel J, Fingerle AA, Pfeiffer F, et al. Dual-energy CT: a phantom comparison of different platforms for abdominal imaging. Eur Radiol. 2018;28(7):2745–55.CrossRef Sellerer T, Noel PB, Patino M, Parakh A, Ehn S, Zeiter S, Holz JA, Hammel J, Fingerle AA, Pfeiffer F, et al. Dual-energy CT: a phantom comparison of different platforms for abdominal imaging. Eur Radiol. 2018;28(7):2745–55.CrossRef
39.
Zurück zum Zitat Kalisz K, Rassouli N, Dhanantwari A, Jordan D, Rajiah P. Noise characteristics of virtual monoenergetic images from a novel detector-based spectral CT scanner. Eur J Radiol. 2018;98:118–25.CrossRef Kalisz K, Rassouli N, Dhanantwari A, Jordan D, Rajiah P. Noise characteristics of virtual monoenergetic images from a novel detector-based spectral CT scanner. Eur J Radiol. 2018;98:118–25.CrossRef
40.
Zurück zum Zitat Ananthakrishnan L, Duan X, Rajiah P, Soesbe TC, Lewis MA, Xi Y, Fielding JR, Lenkinski RE, Leyendecker JR, Abbara S. Phantom validation of spectral detector computed tomography-derived virtual monoenergetic, virtual noncontrast, and iodine quantification images. J Comput Assist Tomogr. 2018;42(6):959–64.CrossRef Ananthakrishnan L, Duan X, Rajiah P, Soesbe TC, Lewis MA, Xi Y, Fielding JR, Lenkinski RE, Leyendecker JR, Abbara S. Phantom validation of spectral detector computed tomography-derived virtual monoenergetic, virtual noncontrast, and iodine quantification images. J Comput Assist Tomogr. 2018;42(6):959–64.CrossRef
Metadaten
Titel
Could both intrinsic and extrinsic iodine be successfully suppressed on virtual non-contrast CT images for detecting thyroid calcification?
verfasst von
Arim Park
Young Hen Lee
Hyung Suk Seo
Publikationsdatum
28.01.2021
Verlag
Springer Singapore
Erschienen in
Japanese Journal of Radiology / Ausgabe 6/2021
Print ISSN: 1867-1071
Elektronische ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-021-01095-8

Weitere Artikel der Ausgabe 6/2021

Japanese Journal of Radiology 6/2021 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.