Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis

verfasst von: Taehee Lee, Jeong Hee Yoon, Jin Young Park, Jihyuk Lee, Jae Won Choi, Chulkyun Ahn, Jeong Min Lee

Erschienen in: Abdominal Radiology | Ausgabe 11/2023

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To investigate the image quality and diagnostic performance of low-contrast-dose liver CT using a deep learning-based iodine contrast-augmenting algorithm (DLICA) for hypovascular hepatic metastases.

Methods

This retrospective study included 128 patients who underwent contrast-enhanced dual-energy CT for hepatic metastasis surveillance between July 2019 and June 2022 using a 30% reduced iodine contrast dose in the portal phase. Three image types were reconstructed: 50-keV virtual monoenergetic images (50-keV VMI); linearly blended images simulating 120-kVp images (120-kVp); and post-processed 120-kVp images using DLICA (DLICA 120-kVp). Three reviewers evaluated lesion conspicuity, image contrast, and subjective image noise. We also measured image noise, contrast-to-noise ratios (CNRs), and signal-to-noise ratios (SNRs). The diagnostic performance for hepatic metastases was evaluated using a jackknife alternative free-response receiver operating characteristic method with the consensus of two independent radiologists as the reference standard.

Results

DLICA 120-kVp demonstrated significantly higher CNR of lesions to liver (5.7 ± 3.1 vs. 3.8 ± 2.1 vs. 3.8 ± 2.1) and higher SNR compared with 50-keV VMI and 120-kVp (< 0.001 for all). DLICA 120-kVp had significantly lower image noise than 50-kVp VMI for all regions (< 0.001 for all). DLICA 120-kVp also exhibited superior lesion conspicuity (4.0 [3.3–4.3] vs. 3.7 [3.0–4.0] vs. 3.7 [3.0–4.0]), higher image contrast, and lower subjective image noise compared with 50-keV VMI and 120-kVp (< 0.001 for all). Although there was no significant difference in the figure of merit for lesion diagnosis among the three methods (= 0.11), DLICA 120-kVp had a significantly higher figure of merit for lesions with a diameter < 20 mm than 50-keV VMI (0.677 vs. 0.648, = 0.007). On a per-lesion basis, DLICA 120-kVp also demonstrated higher sensitivity than the 50-keV VMI (81.2% vs. 72.9%, < 0.001). The specificities per lesion were not significantly different among the three algorithms (= 0.15).

Conclusion

DLICA at 120-kVp provided superior lesion conspicuity and image quality and similar diagnostic performance for hypovascular hepatic metastases compared with 50-keV VMI.

Graphical abstract

Anhänge
Nur mit Berechtigung zugänglich
Literatur
12.
15.
Metadaten
Titel
Deep learning-based iodine contrast-augmenting algorithm for low-contrast-dose liver CT to assess hypovascular hepatic metastasis
verfasst von
Taehee Lee
Jeong Hee Yoon
Jin Young Park
Jihyuk Lee
Jae Won Choi
Chulkyun Ahn
Jeong Min Lee
Publikationsdatum
14.09.2023
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 11/2023
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-023-04039-0

Neu im Fachgebiet Radiologie

ePA: Entlastung oder Mehrarbeit?

Die elektronische Patientenakte (ePA) soll das Gesundheitswesen revolutionieren. Mit über 2000 Krankenhäusern und mehr als 100.000 ärztlichen Praxen ist sie eines der größten Digitalisierungsprojekte Europas. Während die Politik die ePA als „Gamechanger“ feiert, zeigt sich in der Praxis ein anderes Bild.

Hölzerner Fremdkörper in der Orbita? Zuerst eine CT!

Besteht der Verdacht, dass ein Fremdkörper aus Holz in den Orbitalraum eingedrungen ist, spielt die Bildgebung eine entscheidende diagnostische Rolle. Was von CT und MRT zu erwarten ist, hat ein chinesisches Radiologenteam untersucht.

Diagnostik von Rippenfrakturen: KI schlägt Radiologen

Mensch gegen Maschine: Beim Erkennen von Rippenfrakturen in Röntgen- und CT-Aufnahmen entschied sich dieses Duell zugunsten der künstlichen Intelligenz (KI). Die Algorithmen zeigten eine höhere Sensitivität als ihre menschlichen Kollegen.

Ärztinnen überholen Ärzte bei Praxisgründungen

Bei Praxisgründungen haben inzwischen die Frauen deutlich die Nase vorn: Seit zehn Jahren wagen laut apoBank mehr Ärztinnen als Ärzte den Schritt in die Selbstständigkeit. In puncto Finanzierung sind sie aber vorsichtiger als die männlichen Kollegen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.