Purpose

The aim of this study was to determine how well pre-operative size selection for total knee and hip arthroplasties based on the digital imaging with and without additional referencing correlated with the size actually implanted.

Methods

Size selection planning of total knee arthroplasty by digital templating was documented in 46 cases with reference ball (group A) and in 48 cases without ball (group B). In addition, prospective analysis of pre-operative planning was conducted for 52 acetabular components with reference ball (group C) and 69 without ball (group D) as well as stem planning in 38 cases with ball (group E) and 54 cases without ball (group F). The data were analysed and compared with the size of the final component selected during surgery.

Results

The correlation between planned and implanted size for total knee arthroplasty in group A resulted in femoral anteroposterior (AP) r = 0.8622 and lateral r = 0.8333 and in group B AP r = 0.4552 and lateral r = 0.6950. Tibial in group A was AP r = 0.9030 and lateral r = 0.9074 and in group B AP r = 0.7000 and lateral r = 0.6376. For the acetabular components, the results in group C were r = 0.5998 and group D r = 0.6923. For stems, group E was r = 0.5306 and group F r = 0.5786. No correlation between BMI and the difference between planned and implanted size was found in any of the groups.

Conclusion

In the case of total hip arthroplasty there was a relatively low correlation between planned and implanted sizes with or without reference ball. For total knee arthroplasties the already high precision of size planning was further improved by the additional referencing with a reference ball.
Literatur
1.
Zurück zum Zitat Gonzalez DV, Slullitel G, Piccaluga F, Salvati EA (2005) The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 20:51–58 Gonzalez DV, Slullitel G, Piccaluga F, Salvati EA (2005) The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty 20:51–58
2.
Zurück zum Zitat Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br 80:382–390PubMedCrossRef Eggli S, Pisan M, Muller ME (1998) The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg Br 80:382–390PubMedCrossRef
3.
Zurück zum Zitat Blackley HR, Howell GE, Rorabeck CH (2000) Planning and management of the difficult primary hip replacement: preoperative planning an technical considerations. Instr Course Lect 49:3–11PubMed Blackley HR, Howell GE, Rorabeck CH (2000) Planning and management of the difficult primary hip replacement: preoperative planning an technical considerations. Instr Course Lect 49:3–11PubMed
4.
Zurück zum Zitat Knight J, Atwater R (1992) Preoperative planning for total hip arthroplasty. J Arthroplasty 7:403–409PubMedCrossRef Knight J, Atwater R (1992) Preoperative planning for total hip arthroplasty. J Arthroplasty 7:403–409PubMedCrossRef
5.
Zurück zum Zitat Haddad FS, Masri BA, Garbuz DS, Durican CP (1999) The prevention of periprosthetic fractures in total hip and knee arthroplasty. Orthop Clin North Am 30:191–207PubMedCrossRef Haddad FS, Masri BA, Garbuz DS, Durican CP (1999) The prevention of periprosthetic fractures in total hip and knee arthroplasty. Orthop Clin North Am 30:191–207PubMedCrossRef
6.
Zurück zum Zitat Zhao X, Zhu ZA, Zhao J, Li MQ, Wang G, Yu DG, Yu B (2011) The utility of digital templating in total hip arthroplasty with Crowe type II and III dysplastic hips. Int Orthop 35:631–638PubMedCentralPubMedCrossRef Zhao X, Zhu ZA, Zhao J, Li MQ, Wang G, Yu DG, Yu B (2011) The utility of digital templating in total hip arthroplasty with Crowe type II and III dysplastic hips. Int Orthop 35:631–638PubMedCentralPubMedCrossRef
7.
Zurück zum Zitat Bono JV (2004) Digital templating in total hip arthroplasty. J Bone Joint Surg Am 86-A(Suppl 2):118–122PubMed Bono JV (2004) Digital templating in total hip arthroplasty. J Bone Joint Surg Am 86-A(Suppl 2):118–122PubMed
8.
Zurück zum Zitat Hoikka V, Paavilainen T, Lindholm T, Turula K, Ylikoski M (1987) Measurement and restoration of equality in length of the lower limbs in total hip replacement. Skelet Radiol 16:442–446CrossRef Hoikka V, Paavilainen T, Lindholm T, Turula K, Ylikoski M (1987) Measurement and restoration of equality in length of the lower limbs in total hip replacement. Skelet Radiol 16:442–446CrossRef
9.
Zurück zum Zitat White SP, Shardlow DL (2005) Effect of introduction of digital radiographic techniques on pre-operative templating in orthopaedic practice. Ann R Coll Surg Engl 87:53–54PubMedCentralPubMedCrossRef White SP, Shardlow DL (2005) Effect of introduction of digital radiographic techniques on pre-operative templating in orthopaedic practice. Ann R Coll Surg Engl 87:53–54PubMedCentralPubMedCrossRef
10.
Zurück zum Zitat Linclau L, Dokter G, Peene P (1993) Radiological aspects in preoperative planning and postoperative assessment of cementless total hip arthroplasty. Acta Orthop Belg 59:163–167PubMed Linclau L, Dokter G, Peene P (1993) Radiological aspects in preoperative planning and postoperative assessment of cementless total hip arthroplasty. Acta Orthop Belg 59:163–167PubMed
11.
Zurück zum Zitat Rübberdt A, Wich M, Mutze S (2003) Digitale präoperative Planung von Hüftgelenksendoprothesen. Trauma Berufskrankh 5:315–321CrossRef Rübberdt A, Wich M, Mutze S (2003) Digitale präoperative Planung von Hüftgelenksendoprothesen. Trauma Berufskrankh 5:315–321CrossRef
13.
Zurück zum Zitat Lau SL, Mak ASH, Lam WT, Chau CK, Lau KY (2004) Reject analysis: a comparison of conventional film-screen radiography and computed radiography with PACS. Radiography 10:183–187CrossRef Lau SL, Mak ASH, Lam WT, Chau CK, Lau KY (2004) Reject analysis: a comparison of conventional film-screen radiography and computed radiography with PACS. Radiography 10:183–187CrossRef
14.
Zurück zum Zitat The B, Diercks RL, Steward RL, van Ooijen PM (2005) Digital correction of magnification in pelvic x rays for preoperative planning of hip joint replacements: theoretical development and clinical results of a new protocol. Med Phys 32:78–84CrossRef The B, Diercks RL, Steward RL, van Ooijen PM (2005) Digital correction of magnification in pelvic x rays for preoperative planning of hip joint replacements: theoretical development and clinical results of a new protocol. Med Phys 32:78–84CrossRef
15.
Zurück zum Zitat Pickard R, Higgs D, Ward N (2006) The accuracy of the PACS for pre-operative templating. J Bone Joint Surg Br 88-B:264CrossRef Pickard R, Higgs D, Ward N (2006) The accuracy of the PACS for pre-operative templating. J Bone Joint Surg Br 88-B:264CrossRef
16.
Zurück zum Zitat White SP, Bainbridge J, Smith EJ (2008) Assessment of magnification of digital pelvic radiographs in total hip arthroplasty using templating software. Ann R Coll Surg Engl 90:592–596PubMedCentralPubMedCrossRef White SP, Bainbridge J, Smith EJ (2008) Assessment of magnification of digital pelvic radiographs in total hip arthroplasty using templating software. Ann R Coll Surg Engl 90:592–596PubMedCentralPubMedCrossRef
17.
Zurück zum Zitat Bayne CO, Krosin M, Barber TC (2009) Evaluation of the accuracy and use of x-ray markers in digital templating for total hip arthroplasty. J Arthroplasty 24:407–413PubMedCrossRef Bayne CO, Krosin M, Barber TC (2009) Evaluation of the accuracy and use of x-ray markers in digital templating for total hip arthroplasty. J Arthroplasty 24:407–413PubMedCrossRef
18.
Zurück zum Zitat Wimsey S, Pickard R, Shaw G (2006) Accurate scaling of digital radiographs of the pelvis. A prospective trial of two methods. J Bone Joint Surg Br 88:1508–1512PubMedCrossRef Wimsey S, Pickard R, Shaw G (2006) Accurate scaling of digital radiographs of the pelvis. A prospective trial of two methods. J Bone Joint Surg Br 88:1508–1512PubMedCrossRef
19.
Zurück zum Zitat Oddy MJ, Jones MJ, Pendegrass CJ, Pilling JR, Wimhurst JA (2006) Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs. J Bone Joint Surg Br 88:581–585PubMedCrossRef Oddy MJ, Jones MJ, Pendegrass CJ, Pilling JR, Wimhurst JA (2006) Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs. J Bone Joint Surg Br 88:581–585PubMedCrossRef
20.
Zurück zum Zitat Crooijmans HJ, Laumen AM, van Pul C, van Mourik JB (2009) A new digital preoperative planning method for total hip arthroplasties. Clin Orthop Relat Res 467:909–916PubMedCentralPubMedCrossRef Crooijmans HJ, Laumen AM, van Pul C, van Mourik JB (2009) A new digital preoperative planning method for total hip arthroplasties. Clin Orthop Relat Res 467:909–916PubMedCentralPubMedCrossRef
21.
Zurück zum Zitat Kulkarni A, Partington P, Kelly D, Muller S (2008) Disc calibration for digital templating in hip replacement. J Bone Joint Surg Br 90:1623–1626PubMedCrossRef Kulkarni A, Partington P, Kelly D, Muller S (2008) Disc calibration for digital templating in hip replacement. J Bone Joint Surg Br 90:1623–1626PubMedCrossRef
22.
Zurück zum Zitat Gonzalez DV, Comba F, Taveras N, Salvati EA (2008) The utility and precision of analogue and digital preoperative planning for total hip arthroplasty. Int Orthop 32:289–294CrossRef Gonzalez DV, Comba F, Taveras N, Salvati EA (2008) The utility and precision of analogue and digital preoperative planning for total hip arthroplasty. Int Orthop 32:289–294CrossRef
23.
Zurück zum Zitat Conn KS, Clarke MT, Hallett JP (2002) A simple guide to determine the magnification of radiographs and to improve the accuracy of preoperative templating. J Bone Joint Surg Br 84:269–272PubMedCrossRef Conn KS, Clarke MT, Hallett JP (2002) A simple guide to determine the magnification of radiographs and to improve the accuracy of preoperative templating. J Bone Joint Surg Br 84:269–272PubMedCrossRef
24.
Zurück zum Zitat Trickett RW, Hodgson P, Forster MC, Roberson A (2009) The reliability and accuracy of digital templating in total knee replacement. J Bone Joint Surg Br 91-B:903–906CrossRef Trickett RW, Hodgson P, Forster MC, Roberson A (2009) The reliability and accuracy of digital templating in total knee replacement. J Bone Joint Surg Br 91-B:903–906CrossRef
25.
Zurück zum Zitat Miller AG, Purtill JJ (2012) Accuracy of digital templating in total knee arthroplasty. Am J Orthop (Belle Mead NJ) 41(11):510–12 Miller AG, Purtill JJ (2012) Accuracy of digital templating in total knee arthroplasty. Am J Orthop (Belle Mead NJ) 41(11):510–12
26.
Zurück zum Zitat Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL (2009) A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? J Arthroplasty 24:175–179PubMedCrossRef Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL (2009) A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe? J Arthroplasty 24:175–179PubMedCrossRef
27.
Zurück zum Zitat Schmidutz F, Steinbrück A, Wanke-Jellinek L, Pietschmann M, Jansson V, Fottner A (2012) The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty. Int Orthop 36:1767–1772PubMedCentralPubMedCrossRef Schmidutz F, Steinbrück A, Wanke-Jellinek L, Pietschmann M, Jansson V, Fottner A (2012) The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty. Int Orthop 36:1767–1772PubMedCentralPubMedCrossRef
Metadaten
Titel
Digital templating in total knee and hip replacement: an analysis of planning accuracy
verfasst von
Bettina Kniesel
Lukas Konstantinidis
Anja Hirschmüller
Norbert Südkamp
Peter Helwig
Publikationsdatum
01.04.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 4/2014
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-013-2157-1

Weitere Artikel der Ausgabe 4/2014

International Orthopaedics 4/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.