Skip to main content
Erschienen in: European Journal of Plastic Surgery 7/2012

01.07.2012 | Original Paper

Early recognition of ischaemia with continuous real-time tissue oxygen monitoring in head and neck microvascular flaps

verfasst von: Lassi Raittinen, Juhani Pukander, Jussi Laranne

Erschienen in: European Journal of Plastic Surgery | Ausgabe 7/2012

Einloggen, um Zugang zu erhalten

Abstract

Aim of this study was to evaluate the reliability of a continuous real-time tissue oxygen monitoring method (Licox®) for postoperative follow-up of free microvascular flaps after ablative head and neck tumour surgery. We also wanted to establish and test accurate alarm levels for this monitoring method. One hundred eighteen head and neck cancer patients, operated in Tampere University Hospital, Finland, were analysed. Tissue oxygen (PtiO2) levels were continuously monitored with the Licox® system. Receiver operating characteristic analysis was performed considering following alarming signals: a clear change in the trend of the curve leading to a decline more than 50% in 1 h or a decline below 10 mmHg in the PtiO2 level. Licox® recognized all the patients who needed re-operation with sensitivity of 100% and specificity of 88%. The overall success rate was 99.2% (117 of 118) and flap salvage rate 88% (seven of eight), respectively. The Licox® tissue oxygen pressure monitoring system is a reliable method for detecting early postoperative circulation problems in free microvascular flaps. The suggested alarm signals are a clear change in the trend of the curve leading a decline more than 50% in an hour or a decline below 10 mmHg.
Literatur
1.
Zurück zum Zitat Disa JJ, Cordeiro PG, Hidalgo DA (1999) Efficacy of conventional monitoring techniques in free tissue transfer: an 11-year experience in 750 consecutive cases. Plast Reconstr Surg 104:97–101PubMedCrossRef Disa JJ, Cordeiro PG, Hidalgo DA (1999) Efficacy of conventional monitoring techniques in free tissue transfer: an 11-year experience in 750 consecutive cases. Plast Reconstr Surg 104:97–101PubMedCrossRef
2.
Zurück zum Zitat Disa JJ, Hu QY, Hidalgo DA (1997) Retrospective review of 400 consecutive free flap reconstructions for oncologic surgical defects. Ann Surg Oncol 4:663–669PubMedCrossRef Disa JJ, Hu QY, Hidalgo DA (1997) Retrospective review of 400 consecutive free flap reconstructions for oncologic surgical defects. Ann Surg Oncol 4:663–669PubMedCrossRef
3.
4.
Zurück zum Zitat Hidalgo DA, Disa JJ, Cordeiro PG, Hu QY (1998) A review of 716 consecutive free flaps for oncologic surgical defects: refinement in donor-site selection and technique. Plast Reconstr Surg 102:722–732, discussion 733–4PubMedCrossRef Hidalgo DA, Disa JJ, Cordeiro PG, Hu QY (1998) A review of 716 consecutive free flaps for oncologic surgical defects: refinement in donor-site selection and technique. Plast Reconstr Surg 102:722–732, discussion 733–4PubMedCrossRef
5.
Zurück zum Zitat Hofer SO, Timmenga EJ, Christiano R, Bos KE (1993) An intravascular oxygen tension monitoring device used in myocutaneous transplants: a preliminary report. Microsurgery 14:304–309, discussion 310–1PubMedCrossRef Hofer SO, Timmenga EJ, Christiano R, Bos KE (1993) An intravascular oxygen tension monitoring device used in myocutaneous transplants: a preliminary report. Microsurgery 14:304–309, discussion 310–1PubMedCrossRef
6.
Zurück zum Zitat Kamolz LP, Giovanoli P, Haslik W, Koller R, Frey M (2002) Continuous free-flap monitoring with tissue-oxygen measurements: three-year experience. J Reconstr Microsurg 18:487–491, discussion 492–3PubMedCrossRef Kamolz LP, Giovanoli P, Haslik W, Koller R, Frey M (2002) Continuous free-flap monitoring with tissue-oxygen measurements: three-year experience. J Reconstr Microsurg 18:487–491, discussion 492–3PubMedCrossRef
7.
Zurück zum Zitat Morff RJ, Granger HJ (1982) Autoregulation of blood flow within individual arterioles in the rat cremaster muscle. Circ Res 51:43–55PubMedCrossRef Morff RJ, Granger HJ (1982) Autoregulation of blood flow within individual arterioles in the rat cremaster muscle. Circ Res 51:43–55PubMedCrossRef
Metadaten
Titel
Early recognition of ischaemia with continuous real-time tissue oxygen monitoring in head and neck microvascular flaps
verfasst von
Lassi Raittinen
Juhani Pukander
Jussi Laranne
Publikationsdatum
01.07.2012
Verlag
Springer-Verlag
Erschienen in
European Journal of Plastic Surgery / Ausgabe 7/2012
Print ISSN: 0930-343X
Elektronische ISSN: 1435-0130
DOI
https://doi.org/10.1007/s00238-011-0688-5

Weitere Artikel der Ausgabe 7/2012

European Journal of Plastic Surgery 7/2012 Zur Ausgabe

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.