Effect of aging and curing mode on the compressive and indirect tensile strength of resin composite cements

verfasst von: Nadja Rohr, Jens Fischer

Erschienen in: Head & Face Medicine | Ausgabe 1/2017

Abstract

Background

Resin composite cements are used in dentistry to bond ceramic restorations to the tooth structure. In the oral cavity these cements are subjected to aging induced by masticatory and thermal stresses. Thermal cycling between 5 and 55 °C simulates the effect of varying temperatures in vitro. Purpose of this study was to compare indirect tensile to compressive strength of different cements before and after thermal cycling. The effect of the curing mode was additionally assessed.

Methods

Indirect tensile strength and compressive strength of 7 dual-curing resin composite cements (Multilink Automix, Multilink SpeedCem, RelyX Ultimate, RelyX Unicem 2 Automix, Panavia V5, Panavia SA Plus, Harvard Implant semi-permanent) was measured. The specimens were either autopolymerized or light-cured (n = 10). The mechanical properties were assessed after 24 h water storage at 37 °C and after aging (20,000 thermo cycles) with previous 24 h water storage at 37 °C.

Results

Indirect tensile strength ranged from 5.2 ± 0.8 to 55.3 ± 4.2 MPa, compressive strength from 35.8 ± 1.8 MPa to 343.8 ± 19.6 MPa.

Conclusions

Thermocyclic aging of 20,000 cycles can be considered a suitable method to simulate the degradation of indirect tensile strength but not compressive strength of resin composite cements. The effect of thermocycling and the curing mode on the resin composite cements is material dependent and cannot be generalized.
Abkürzungen
CS
Compressive strength
HIS
Harvard Implant semi-permanent
ITS
Indirect tensile strength
MLA
Multilink Automix
MSC
Multilink SpeedCem
PSA
Panavia SA plus
PV5
Panavia V5
RUL
RelyX Ultimate
RUN
RelyX Unicem 2 Automix
TC
Thermal cycling

Background

The use of esthetic ceramic materials in dentistry requires the application of resin composite cement to bond a restoration to the tooth structure. Resin composite materials are generally superior to conventional cements in providing higher strength, lower cement wear and improved esthetics [14]. Resin composite cements consist of three components: a polymer matrix, fillers and silanes that connect organic and inorganic phase [58]. These single components and their respective microstructure define the properties of the resin composite cement such as elasticity, hardness, strength and thermal as well as chemical stability [6, 9, 10]. To bond to the tooth substance, adhesive resin composite cements require the application of an acidic agent plus a priming system. Self-adhesive resin composite cements were thus designed to adhere to the tooth structure by themselves, while eliminating the need for additional pre-treatments of tooth structures. The polymer matrix of these self-adhesive resin cements is generally composed of phosphoric and/or carboxylic acid methacrylate monomers [3]. Self-adhesive cements interact only superficially with mineralized tissues hence they do not form a dentin hybrid layer nor resin tags [11, 12], resulting in lower bond strengths to both, dentin and enamel when compared to adhesive resin composite cements where an additional tooth conditioning system is applied [13]. Superior vickers hardness, modulus of elasticity, compressive and flexural strength were measured for adhesive cements in comparison to self-adhesive cements [3, 14].
The polymerization of dual-curing resin composite cements is catalyzed by a chemically (autopolymerization) and a photo (light-curing) activated initiator. The polymerization reaction starts with the mixing of base and catalyst paste, thus activating the chemical initiator. Hence the processing time is limited. Photo initiation allows to advance the polymerization reaction at the time a restoration is correctly placed and cement excess is removed. However, areas under an opaque restoration that are not reached by the light may not polymerize as much as dual-cured areas. Most cement materials reveal a higher degree of conversion by dual-curing compared to autopolymerization [1517]. The degree of conversion of autopolymerized cements is influenced by the concentration of monomer and catalyst as well as the ambient temperature [1820]. Cements with a high degree of conversion also provide better mechanical properties [5, 16, 21].
Resin composite cements are brittle materials and therefore more susceptible to tensile loading than to compressive stress [22, 23]. Although, compressive strength of a cement is an important factor to predict a restoration’s resistance against masticatory forces [2426]. Cements in an aqueous medium such as saliva are exposed to a long-term aging process, which might significantly compromise their mechanical properties [27, 28]. The effects are wide-ranging but generally include the leaching of unreacted compounds and the degradation of the polymer network [27, 29]. To artificially age dental materials, several methods such as cyclic loading, water storage, or thermal cycling are commonly used. Thermal cycling between 5 and 55 °C simulates the effect of varying temperatures present in the oral cavity due to hot or cold beverages [30, 31]. The suggested duration of thermal cycling ranges from 3000 to 100,000 cycles [3237]. It is proposed that 10,000 cycles may represent 1 year of service [38]. After the placement of a restoration, the cement is setting at 37 °C and polymerizes for up to 24 h, hence during this time, thermal stress is rare. Therefore, to imitate the clinical situation, prior to artificial aging the specimens should be stored at 37 °C for 24 h [22].
The impact of thermal cycling on indirect tensile strength and compressive strength has been systematically assessed for only one cement and should be verified with additional cements [22]. Purpose of this study was therefore to compare indirect tensile to compressive strength of a temporary, three self-adhesive and three adhesive cements before and after thermal cycling. The effect of the curing mode was additionally assessed. Hypotheses were that adhesive cements achieve higher indirect tensile and compressive strength than self-adhesive cements and that thermocyclic aging significantly decreases indirect tensile and compressive strength of the cements.

Methods

Indirect tensile strength (ITS) and compressive strength (CS) of 7 dual-curing resin composite cements were measured (Table 1). The specimens were either autopolymerized or light-cured. ITS and CS were measured after 24 h water storage at 37 °C and after 24 h water storage at 37 °C followed by thermocyclic loading. Cylindrical test specimens 3 mm in height and diameter (n = 10) were produced using a customized Teflon mold. The cement was filled into the respective cavities of the mold and kept in place with a plastic foil and a glass plate on each side. 10 specimens were produced for each group and either autopolymerized or light cured for 20 s from both sides (Elipar S10, 3 M ESPE, Seefeld, Germany). All specimens were then stored in 37 °C water for 24 h. Aging was performed for the respective specimens using a thermocycler (Thermocycler THE-1100, SD Mechatronik, Feldkirchen-Westerham, Germany). The specimens were immersed alternately in water baths of 5 and 55 °C, using a sieve for storage and transportation. The cycle duration was 1 min with a dwell time in each water bath of 20 s and a transfer time between baths of 10 s. 20,000 cycles within 14 days were performed to age the specimens.
Table 1
Cement material composition provided by the manufacturer
 
Name
Manufacturer
Type
Monomers
Fillers
Initiators
MLA
Multilink Automix
Ivoclar Vivadent
Adhesive resin composite
Base paste: Bis-GMA, HEMA, 2-dimethylaminoethyl methacrylate
Catalyst paste: ethyoxylated bisphenol A dimethacrylate, UDMA, HEMA
40 vol%
- Barium glass
- Ytterbium trifluoride
- Spheroid mixed oxide
Particle size: 0.25–3.0 μm
Dibenzoyl peroxide
MSC
Multilink Speed CEM
Ivoclar Vivadent
Self-adhesive resin composite
Base paste: UDMA, TEGDMA, polyethylene glycol dimethacrylate
Catalyst paste: polyethylene glycol dimethacrylate, TEGDMA, Methacrylated phosphoric acid ester, UDMA
40 vol%
- Barium glass
- Ytterbium trifluoride
Particle size: 0.1–7 μm
Dibenzoyl peroxide
RUL
RelyX Ultimate
3 M ESPE
Adhesive resin composite
Base paste: methacrylate monomers containing phosphoric acid groups, methacrylate monomers
Catalyst paste: methacrylate monomers
43 vol%
- Silanated fillers
- Alkaline (basic) fillers
Particle size: 13 μm
Sodium toluene-4-sulphinate,
Disodium peroxodisulphate,
Tert-butyl 3,5,5-trimethylperoxyhexanoate
RUN
RelyX Unicem 2 Automix
3 M ESPE
Self-adhesive resin composite
Base paste: phosphoric acid modified methacrylate monomers, bi-functional methacrylate
Catalyst paste: methacrylate monomers
43 vol%
- Alkaline (basic) fillers
- Silanated fillers
Particle size: 12.5 μm
Sodium toluene-4-sulphinate, Sodium Persulfate, Tert-butyl 3,5,5-trimethylperoxyhexanoate
PV5
Panavia V5
Kuraray
Adhesive resin composite
Paste A: Bis-GMA, TEGDMA, Hydrophobic aromatic dimethacrylate, Hydrophilic aliphatic dimethacrylate
Paste B: Bis-GMA, Hydrophobic aromatic dimethacrylate, Hydrophilic aliphatic dimethacrylate
38 vol%
- Silanated barium glass filler
- Silanated fluoroalminosilicate glass filler
- Colloidal silica
- Silanated alminium oxide filler
Particle size: 0.01–12 μm
dl-Camphorquinone
PSA
Panavia SA plus
Kuraray
Self-adhesive resin composite
Paste A: 10-MDP, Bis-GMA,
TEGDMA, Hydrophobic aromatic dimethacrylate, HEMA
Paste B: Hydrophobic aromatic dimethacrylate, hydrophobic aliphatic dimethacrylate
40 vol%
- Silanated barium glass filler
- Silanated colloidal silica
Particle size: 0.02–20 μm
dl-Camphorquinone
HIS
Harvard Implant semi-permanent
Harvard Dental International
temporary resin cement
Methacrylates, zinc oxide
10-MDP 10-Methacryloyloxydecyl dihydrogen phosphate, Bis-GMA bisphenol A-glycidyl methacrylate, HEMA 2-hydroxyethyl methacrylate, TEGDMA triethyleneglycol dimethacrylate, UDMA urethane dimethacrylate
Specimens were loaded until fracture either after 24 h of water storage or after thermal cycling using a universal testing machine (Z020, Zwick/Roell, Ulm, Germany) (Fig. 1). Cross-head speed was set to 1 mm/min. Prior to the measurements, the specimens were sized in diameter and height using a digital caliper (Cal IP 67, Tesa, Ingersheim, Germany). For compressive strength the load was applied axially, for indirect tensile strength radially. Strength values were calculated using the following equations:
$$ Compressivestrength:{\sigma}_c=F/\pi {\left(d/2\right)}^2 $$
$$ Indirect tensile strength\ {\sigma}_t=2F/\pi dh $$
F is the fracture load; d the specimen diameter and h the specimen height. All data was tested for normal distribution using Shapiro-Wilk test. Since data was normal distributed, one-way ANOVA was applied followed by a Tukey HSD test to check for differences between the cement groups of ITS and (p < 0.05). Three-way ANOVA was performed with all ITS and CS values to test the effect of cement, curing mode and aging procedure (statplus pro V6.1.25, Analystsoft).

Results

Values for ITS and CS are listed in Table 2. Values of ITS or CS with no statistical difference within one cement are marked with identical superscript letters. To visualize the effect of aging and curing mode on the different cements, the mean values are correlated in Figs. 2 for ITS and Fig. 3 for CS. A grey line in each graphic indicates similar values on x-and y-axis meaning that if the dot of a material is close to the grey line, there is no effect of either a) curing-mode after 24 h, b) curing-mode after thermal cycling c) aging of light-cured specimens or d) aging of autopolymerized specimens.
Table 2
Indirect tensile strength and compressive strength mean values with standard deviations of the cements for light-cured and autopolymerized specimens after 24 h water storage at 37 °C (24 h) and aging (TC: 24 h water storage at 37 °C followed by 20,000 thermocycles)
(MPa)
Indirect tensile strength
Compressive strength
light-curing
autopolymerization
light-curing
autopolymerization
cement
24 h
TC
24 h
TC
24 h
TC
24 h
TC
MLA
55.3 (4.2)A
43.9 (4.4)B
51.3 (1.7)C
41.1 (1.7)B
343.8 (19.6)A
326.3 (13.5)B
321.0 (9.3)B
300.5 (10.6)C
MSC
41.0 (2.2)A
36.0 (3.0)B
39.8 (2.9)A
33.9 (3.2)B
244.3 (11.0)A
220.9 (8.9)B
228.6 (12.7)B
222.9 (13.5)B
RUL
46.0 (4.8)A
38.0 (2.7)B
33.7 (3.7)B
39.2 (7.1)B
293.5 (10.5)A
286.6 (14.5)A
238.8 (28.8)B
301.7 (13.3)A
RUN
44.4 (4.7)A
33.3 (5.1)B
39.1 (3.6)A,B
40.2 (7.6)A
283.2 (17.3)A,B
273.1 (28.2)A
259.9 (20.8)A
305.2 (11.5)B
PV5
54.0 (3.2)A
52.2 (4.6)A
52.5 (5.0)A
43.7 (4.2)B
325.8 (12.3)A
312.3 (6.6)A,B
310.5 (15.2)B
283.8 (13.2)C
PSA
49.5 (2.5)A
37.4 (6.8)B
38.2 (1.9)B
40.9 (4.7)B
297.8 (7.1)A
300.8 (10.1)A
263.9 (13.8)B
267.3 (15.8)B
HIS
7.5 (1.4)A
6.9 (1.0)A,B
5.2 (0.8)C
6.1 (1.0)B,C
37.7 (3.3)A
39.8 (1.8)A
37.1 (7.0)A
35.8 (1.8)A
Values of ITS or CS with no statistical difference within one cement are marked with superscript letters (horizontal comparison)

Indirect tensile strength

ITS after 24 h water storage ranged within all groups between 5.2 ± 0.8 MPa for the autopolymerized temporary cement (HIS) and 55.3 ± 4.2 MPa for a light-cured adhesive resin composite cement (MLA). Effects of aging and light-curing mode on ITS are visualized in Fig. 2. Statistical higher (MLA, RUL, PSA and HIS) or values with no statistical difference (MSC, RUN, PV5) were obtained for light-cured specimens compared to autopolymerized specimens after 24 h water storage (Fig. 2a). When light-cured specimens were compared to autopolymerized specimens after thermo-cycling, values of RUN were significantly lower (p = 0.038) and of PV5 significantly higher (p < 0.001) (Fig. 2b). For autopolymerized specimens, aging in the thermocycler significantly decreased values of MLA, MSC and PV5 (Fig. 2c). No statistical different values were found for the other cements before and after aging of autopolymerized specimens. Aging of light-cured specimens significantly decreased ITS of MLA, MSC, RUL, RUN and PSA (Fig. 2d). Values for PV5, and HIS remained constant. Of all cements, highest values in all groups were obtained by either MLA or PV5. The ranking between MSC, RUL, RUN and PSA changed, depending on the curing or aging mode applied. HIS achieved statistically lowest values of all cements in all groups (p < 0.001). Three-way ANOVA revealed a significant effect on the ITS values of the cement, curing mode as well as the aging procedure (p < 0.001).

Compressive strength

CS ranged between 35.8 ± 1.8 MPa for autopolymerized and aged HIS and 343.8 ± 19.6 MPa for light-cured MLA after 24 h water storage. Effects of aging and light-curing mode on CS are visualized in Fig. 3. For specimens after 24 h water storage, light-curing increased CS values significantly for MLA, MSC, RUL and PSA (Fig. 3a). After thermo-cycling, CS of light-cured specimens was significantly higher for MLA, PV5 and PSA (Fig. 2b). Autopolymerized specimens of RUN achieved significantly higher CS after aging than light-cured specimens (p = 0.006) (Fig. 3b). For autopolymerized specimens, aging significantly decreased CS for MLA and PV5 and increased CS of RUN and RUL. CS of all other cements (MSC, PSA, HIS) remained constant (Fig. 3c). Aging of light-cured specimens did not affect CS for all cements except MLA and MSC where the CS significantly dropped after aging. A linear correlation (y = 1.038×/R2 = 0.992) was found for CS before and after aging for light-cured specimens (Fig. 3d).
For light cured specimens cements ranked as follows before and after aging: MLA > PV5 > PSA > RUL > RUN > MSC > HIS. For autopolymerized specimens before aging ranking was similar to the light-cured except for RUL and RUN switching places. After aging the cements ranked: RUN > RUL > MLA > PV5 > PSA > MSC > HIS. Three-way ANOVA revealed a significant effect on the CS values of the cement and curing mode (p < 0.001), but not of the aging procedure (p = 0.709).

Correlation between indirect tensile and compressive strength

A linear correlation (y = 0.160×/R2 = 0.983) was found between ITS and CS for light-cured (y = 0.162×/R2 = 0.992) and autopolymerized (y = 0.158×/R2 = 0.960) specimens after 24 h of water storage (Fig. 4). After thermo-cycling cements were affected differently by the aging process as described above, hence ITS and CS did not correlate likewise.

Discussion

Indirect tensile strength of a temporary, three self-adhesive and three adhesive cements was compared to compressive strength before and after thermal cycling. The effect of the curing mode was additionally assessed. The hypotheses that adhesive cements achieve higher indirect tensile and compressive strength than self-adhesive cements was rejected because the mechanical properties depended rather on the cement’s individual composition and filler types. That thermocyclic aging significantly decreases indirect tensile and compressive strength of the cements was verified for indirect tensile strength but not for compresssive strength.

Indirect tensile strength

After 24 h water storage higher ITS values were recorded for all light-cured cements than for autopolymerized, although the difference was only significant for MLA, RUL, PSA and HIS. This difference was probably due to a higher degree of polymerisation of the light-cured specimens, as it was previously reported [17, 2022, 36].
After thermo-cycling ITS value of light-cured RUN was significantly lower and of PV5 significantly higher than the values obtained after autopolymerization. Aging affected each cement differently, hence no distinct effect of the curing mechanism could be observed when autopolymerized and light-cured specimens were compared after aging.
Aging of autopolymerized specimens significantly decreased values of MLA, MSC and PV5. ITS of the other cements remained constant. The decrease of ITS of autopolymerized MLA, MSC and PV5 specimens indicates that these materials are more susceptible to temperature changes at the surface which may have induced the formation of superficial micro-cracks favored by the degradation of the polymer matrix and the absorption of water. An insufficient polymerization due to autopolymerization may have also resulted in a higher rate of unreacted and potentially leaching components inducing an increased surface inhomogeneity.
Aging of light-cured specimens significantly decreased ITS of MLA, MSC, RUL, RUN and PSA. Due to the high ITS of the light-cured specimens after 24 h, these specimens may also be more susceptive to aging than the autopolymerized specimens.

Compressive strength

Higher CS values were obtained for light-cured specimens compared to autopolymerized specimens after 24 h water storage, although the difference was only statistically significant for MLA, MSC, RUL and PSA. These findings are consistent with the ones for ITS and due to the increased degree of conversion of the light-cured specimens. In comparison to the other cements, MLA, RUL and PSA revealed a stronger dependence on light-curing to achieve highest strength values. PSA contains 10-Methacryloyloxydecyl dihydrogen phosphate (MDP) inhibiting the polymerization reaction [39]. Significantly lower values were found for autopolymerized CS values of PSA compared to light-cured specimens after 24 h indicating that the polymerization reaction might have still been proceeding.
After thermo-cycling, CS of light-cured specimens was significantly higher for MLA, PV5 and PSA but lower for RUN compared to autopolymerized specimens. For RUN results were inverse, which might be explained by a higher amount of unreacted phosphoric acid ester groups, resulting in a higher degree of water up-take and thus an increased CS. Higher sorption was previously recorded for RUN for autopolymerized specimens [9]. Aging of autopolymerized specimens significantly decreased CS for MLA and PV5 due to a degradation of the material that might be due to a lower degree of polymerization than for the light-cured specimens. Values of RUN and RUL were increased after aging. RUL and RUN previously presented high sorption that might have been responsible for increasing their strength after thermal cycling [9]. Light-cured specimens correlated linearly before and after aging and were therefore less susceptible to aging than autoplymerized specimens. Since three-way ANOVA revealed no significant effect of the aging with 20,000 thermocycles on the CS values, the applied aging protocol does not seem suitable for this test method. Effects of a prolonged cycling should be further investigated.

Correlation between indirect tensile and compressive strength

The filler content [7], the degree of conversion [23] and the monomer type [8] are factors affecting the mechanical strength of resin composite cements. Autopolymerized specimens revealed a stronger variability in CS and ITS than dual-cured specimens [15, 17, 22]. As previously reported the effect of the curing mode varied among the cements and cannot be generalized [36]. According to the linear correlation between CS of light-cured specimens before and after aging CS was less affected by aging than ITS indicating that the mechanical properties measured with a CS test are less susceptible to thermocyclic aging and for light-cured specimens the material properties are more stable, which findings are in accordance with previous results [22]. CS and ITS correlate linearly after 24 h water storage but not after aging because the cements age differently depending on their components.

Test method

Previously it was reported that a compressive strength test is a rather insensitive test method compared to indirect tensile strength [22] or flexural strength [28]. In the present study it was found that both ITS and CS tests have their eligibility since aging of the cements resulted in different effects for either ITS or CS. The ITS test is more sensitive to surface defects than the CS test [22]. CS test may depend mainly on the filler size and distribution and the quality of silanization. It is probably also affected by the mode of polymerization. The effect of the degradation mechanism on the ITS and CS should be further investigated.
Thermocyclic aging has been evaluated as the most efficient aging procedure and was recommended to perform for at least 4 days for resin composite cement [22]. Thermal cycling has a considerable effect on the cements’ strength and the degree of the effect varied according to the cement’s composition. It is suggested that the temperature change and the associated dimensional changes of the two phases – polymer matrix and fillers – generate internal stress [22, 35, 37] due to different coefficients of thermal expansion of organic and inorganic fillers [22].
Thermocyclic aging has been previously applied to ITS and CS specimens of different resin composite cements but only for 2000 cycles within 20 h [36]. In that study no statistically significant differences between the values after aging were found. Therefore, a thermocycling duration of 2000 cycles within 20 h can be considered insufficient to successfully age resin composite cements. In the present study 20,000 cycles were performed within 14 days, providing measurable aging effects on ITS values.

Clinical implications

CS test predicts the resistance against the masticatory force and therefore allows to estimate the cements clinical performance [24]. Materials with low intrinsic strengths such as silicate ceramics achieve a higher loading capacity when cemented with adhesive cement than with glass-ionomer [25]. A cement with a compressive strength above 320 MPa is ideal for cementing silicate ceramics on zirconia implants since the cement optimally supports the restorative material [26]. Since these 320 MPa were measured for autopolymerized cements after 24 h 37 °C water storage, in the present investigation PV5 and MLA can be considered best cements applying to this requirement with mean autopolymerized CS values of 312 and 326 MPa. Although after aging of the autopolymerized specimens, the cements do not exceed the 320 MPa.
According to ISO 9917–1:2007 for water based dental cements, CS of dental cements should be over 70 MPa. All cements except HIS fulfill this requirement. HIS is not indicated for permanent cementation but for a long-term temporary cementation on implants. When covered by bulky restorations cements might be insufficiently light-cured [21], which can also affect the mechanical strength of the cements. For most cements light-curing was beneficial to increase the mechanical strength. Only RUN and RUL revealed better or similar mechanical properties after thermocyclic aging of autopolymerized specimens than of light-cured ones, which may be explained by more intense water uptake.

Conclusions

Within the limitations imposed by the current study, the following conclusions were drawn:
  • Indirect tensile and compressive strength of the cements after 24 h water storage correlate linearly.
  • Thermocyclic aging of 20,000 cycles can be considered a suitable method to simulate the degradation of indirect tensile strength but not compressive strength of resin composite cements.
  • The effect of thermocycling on the resin composite cements is material dependent and cannot be generalized.

Acknowledgements

This study was kindly supported with materials by VITA Zahnfabrik, Bad Säckingen.

Funding

This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.

Availability of data and materials

All references are available at pubmed.​com
Not applicable.
Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat Ban S, Hasegawa J, Anusavice KJ. Effect of loading conditions on bi-axial flexure strength of dental cements. Dent Mater. 1992;8:100–4.CrossRefPubMed Ban S, Hasegawa J, Anusavice KJ. Effect of loading conditions on bi-axial flexure strength of dental cements. Dent Mater. 1992;8:100–4.CrossRefPubMed
2.
Zurück zum Zitat Peutzfeldt A. Dual-cure resin cements: in vitro wear and effect of quantity of remaining double bonds, filler volume, and light curing. Acta Odontol Scand. 1995;53:29–34.CrossRefPubMed Peutzfeldt A. Dual-cure resin cements: in vitro wear and effect of quantity of remaining double bonds, filler volume, and light curing. Acta Odontol Scand. 1995;53:29–34.CrossRefPubMed
3.
Zurück zum Zitat Ilie N, Simon A. Effect of curing mode on the micro-mechanical properties of dual-cured self-adhesive resin cements. Clin Oral Investig. 2012;16:505–12.CrossRefPubMed Ilie N, Simon A. Effect of curing mode on the micro-mechanical properties of dual-cured self-adhesive resin cements. Clin Oral Investig. 2012;16:505–12.CrossRefPubMed
4.
Zurück zum Zitat Attar N, Tam LE, McComb D. Mechanical and physical properties of contemporary dental luting agents. J Prosthet Dent. 2003;89:127–34.CrossRefPubMed Attar N, Tam LE, McComb D. Mechanical and physical properties of contemporary dental luting agents. J Prosthet Dent. 2003;89:127–34.CrossRefPubMed
5.
Zurück zum Zitat Diaz-Arnold AM, Vargas MA, Haselton DR. Current status of luting agents for fixed prosthodontics. J Prosthet Dent. 1999;81:135–41.CrossRefPubMed Diaz-Arnold AM, Vargas MA, Haselton DR. Current status of luting agents for fixed prosthodontics. J Prosthet Dent. 1999;81:135–41.CrossRefPubMed
6.
Zurück zum Zitat Zandinejad AA, Atai M, Pahlevan A. The effect of ceramic and porous fillers on the mechanical properties of experimental dental composites. Dent Mater. 2006;22:382–7.CrossRefPubMed Zandinejad AA, Atai M, Pahlevan A. The effect of ceramic and porous fillers on the mechanical properties of experimental dental composites. Dent Mater. 2006;22:382–7.CrossRefPubMed
7.
Zurück zum Zitat White SN, Yu Z. Physical properties of fixed prosthodontic, resin composite luting agents. Int J Prosthodont. 1993;6:384–9.PubMed White SN, Yu Z. Physical properties of fixed prosthodontic, resin composite luting agents. Int J Prosthodont. 1993;6:384–9.PubMed
8.
Zurück zum Zitat Asmussen E, Peutzfeldt A. Influence of UEDMA BisGMA and TEGDMA on selected mechanical properties of experimental resin composites. Dent Mater. 1998;14:51–6.CrossRefPubMed Asmussen E, Peutzfeldt A. Influence of UEDMA BisGMA and TEGDMA on selected mechanical properties of experimental resin composites. Dent Mater. 1998;14:51–6.CrossRefPubMed
9.
Zurück zum Zitat Müller JA, Rohr N, Fischer J. Evaluation of ISO 4049: water sorption and water solubility of resin cements. Eur J Oral Sci. 2017;125:141–50.CrossRefPubMed Müller JA, Rohr N, Fischer J. Evaluation of ISO 4049: water sorption and water solubility of resin cements. Eur J Oral Sci. 2017;125:141–50.CrossRefPubMed
10.
Zurück zum Zitat Peutzfeldt A. Resin composites in dentistry: the monomer systems. Eur J Oral Sci. 1997;105:97–116.CrossRefPubMed Peutzfeldt A. Resin composites in dentistry: the monomer systems. Eur J Oral Sci. 1997;105:97–116.CrossRefPubMed
11.
Zurück zum Zitat De Munck J, Vargas M, Van Landuyt K, Hikita K, Lambrechts P, Van Meerbeek B. Bonding of an auto-adhesive luting material to enamel and dentin. Dent Mater. 2004;20:963–71.CrossRefPubMed De Munck J, Vargas M, Van Landuyt K, Hikita K, Lambrechts P, Van Meerbeek B. Bonding of an auto-adhesive luting material to enamel and dentin. Dent Mater. 2004;20:963–71.CrossRefPubMed
12.
Zurück zum Zitat Monticelli F, Osorio R, Mazzitelli C, Ferrari M, Toledano M. Limited decalcification/diffusion of self-adhesive cements into dentin. J Dent Res. 2008;87:974–9.CrossRefPubMed Monticelli F, Osorio R, Mazzitelli C, Ferrari M, Toledano M. Limited decalcification/diffusion of self-adhesive cements into dentin. J Dent Res. 2008;87:974–9.CrossRefPubMed
13.
Zurück zum Zitat Rohr N, Fischer J. An evaluation of tooth surface treatment strategies for adhesive cementation - an elaborated primer supersedes tooth etching. J Adv Prosthodont. 2017;9:85–92.CrossRefPubMedPubMedCentral Rohr N, Fischer J. An evaluation of tooth surface treatment strategies for adhesive cementation - an elaborated primer supersedes tooth etching. J Adv Prosthodont. 2017;9:85–92.CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Piwowarczyk A, Lauer HC. Mechanical properties of luting cements after water storage. Oper Dent. 2003;28:535–42.PubMed Piwowarczyk A, Lauer HC. Mechanical properties of luting cements after water storage. Oper Dent. 2003;28:535–42.PubMed
15.
Zurück zum Zitat Caughman WF, Chan DC, Rueggeberg FA. Curing potential of dual-polymerizable resin cements in simulated clinical situations. J Prosthet Dent. 2001;85:479–84.CrossRefPubMed Caughman WF, Chan DC, Rueggeberg FA. Curing potential of dual-polymerizable resin cements in simulated clinical situations. J Prosthet Dent. 2001;85:479–84.CrossRefPubMed
16.
Zurück zum Zitat Braga RR, Condon JR, Ferracane JL. Vitro wear simulation measurements of composite versus resin-modified glass ionomer luting cements for all-ceramic restorations. J Esthet Restor Dent. 2002;14:368–76.CrossRefPubMed Braga RR, Condon JR, Ferracane JL. Vitro wear simulation measurements of composite versus resin-modified glass ionomer luting cements for all-ceramic restorations. J Esthet Restor Dent. 2002;14:368–76.CrossRefPubMed
17.
Zurück zum Zitat Fonseca RG, Santos JG, Adabo GL. Influence of activation modes on diametral tensile strength of dual-curing resin cements. Braz Oral Res. 2005;19:267–71.CrossRefPubMed Fonseca RG, Santos JG, Adabo GL. Influence of activation modes on diametral tensile strength of dual-curing resin cements. Braz Oral Res. 2005;19:267–71.CrossRefPubMed
18.
Zurück zum Zitat Cantoro A, Goracci C, Papacchini F, Mazzitelli C, Fadda GM, Ferrari M. Effect of pre-cure temperature on the bonding potential of self-etch and self-adhesive resin cements. Dent Mater. 2008;24:577–83.CrossRefPubMed Cantoro A, Goracci C, Papacchini F, Mazzitelli C, Fadda GM, Ferrari M. Effect of pre-cure temperature on the bonding potential of self-etch and self-adhesive resin cements. Dent Mater. 2008;24:577–83.CrossRefPubMed
19.
Zurück zum Zitat Cantoro A, Goracci C, Carvalho CA, Coniglio I, Ferrari M. Bonding potential of self-adhesive luting agents used at different temperatures to lute composite onlays. J Dent. 2009;37:454–61.CrossRefPubMed Cantoro A, Goracci C, Carvalho CA, Coniglio I, Ferrari M. Bonding potential of self-adhesive luting agents used at different temperatures to lute composite onlays. J Dent. 2009;37:454–61.CrossRefPubMed
20.
Zurück zum Zitat Spinell T, Schedle A, Watts DC. Polymerization shrinkage kinetics of dimethacrylate resin-cements. Dent Mater. 2009;25:1058–66.CrossRefPubMed Spinell T, Schedle A, Watts DC. Polymerization shrinkage kinetics of dimethacrylate resin-cements. Dent Mater. 2009;25:1058–66.CrossRefPubMed
21.
Zurück zum Zitat De Souza G, Braga RR, Cesar PF, Lopes GC. Correlation between clinical performance and degree of conversion of resin cements: a literature review. J Appl Oral Sci. 2015;23:358–68.CrossRefPubMedPubMedCentral De Souza G, Braga RR, Cesar PF, Lopes GC. Correlation between clinical performance and degree of conversion of resin cements: a literature review. J Appl Oral Sci. 2015;23:358–68.CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Blumer L, Schmidli F, Weiger R, Fischer JA. Systematic approach to standardize artificial aging of resin composite cements. Dent Mater. 2015;31:855–63.CrossRefPubMed Blumer L, Schmidli F, Weiger R, Fischer JA. Systematic approach to standardize artificial aging of resin composite cements. Dent Mater. 2015;31:855–63.CrossRefPubMed
23.
Zurück zum Zitat Fonseca RG, Artusi TP, dos Santos JG, Adabo GL. Diametral tensile strength of dual-curing resin cements submitted exclusively to autopolymerization. Quintessence Int. 2007;38:e527–31.PubMed Fonseca RG, Artusi TP, dos Santos JG, Adabo GL. Diametral tensile strength of dual-curing resin cements submitted exclusively to autopolymerization. Quintessence Int. 2007;38:e527–31.PubMed
24.
Zurück zum Zitat White SN, Yu Z. Compressive and diametral tensile strengths of current adhesive luting agents. J Prosthet Dent. 1993;69:568–72.CrossRefPubMed White SN, Yu Z. Compressive and diametral tensile strengths of current adhesive luting agents. J Prosthet Dent. 1993;69:568–72.CrossRefPubMed
25.
Zurück zum Zitat Stawarczyk B, Beuer F, Ender A, Roos M, Edelhoff D, Wimmer T. Influence of cementation and cement type on the fracture load testing methodology of anterior crowns made of different materials. Dent Mater J. 2013;32:888–95.CrossRefPubMed Stawarczyk B, Beuer F, Ender A, Roos M, Edelhoff D, Wimmer T. Influence of cementation and cement type on the fracture load testing methodology of anterior crowns made of different materials. Dent Mater J. 2013;32:888–95.CrossRefPubMed
26.
Zurück zum Zitat Rohr N, Märtin S, Fischer J. Correlations between fracture load of zirconia implant supported single crowns and mechanical properties of restorative material and cement. Dent Mater J. 2017. In press. Rohr N, Märtin S, Fischer J. Correlations between fracture load of zirconia implant supported single crowns and mechanical properties of restorative material and cement. Dent Mater J. 2017. In press.
27.
Zurück zum Zitat Medeiros IS, Gomes MN, Loguercio AD, Filho LE. Diametral tensile strength and Vickers hardness of a composite after storage in different solutions. J Oral Sci. 2007;49:61–6.CrossRefPubMed Medeiros IS, Gomes MN, Loguercio AD, Filho LE. Diametral tensile strength and Vickers hardness of a composite after storage in different solutions. J Oral Sci. 2007;49:61–6.CrossRefPubMed
28.
29.
Zurück zum Zitat Ferracane JL. Hygroscopic and hydrolytic effects in dental polymer networks. Dent Mater. 2006;22:211–22.CrossRefPubMed Ferracane JL. Hygroscopic and hydrolytic effects in dental polymer networks. Dent Mater. 2006;22:211–22.CrossRefPubMed
30.
Zurück zum Zitat Barclay CW, Spence D, Laird WR. Intra-oral temperatures during function. J Oral Rehabil. 2005;32:886–94.CrossRefPubMed Barclay CW, Spence D, Laird WR. Intra-oral temperatures during function. J Oral Rehabil. 2005;32:886–94.CrossRefPubMed
31.
Zurück zum Zitat Ernst CP, Canbek K, Euler T, Willershausen B. In vivo validation of the historical in vitro thermocycling temperature range for dental materials testing. Clin Oral Investig. 2004;8:130–8.PubMed Ernst CP, Canbek K, Euler T, Willershausen B. In vivo validation of the historical in vitro thermocycling temperature range for dental materials testing. Clin Oral Investig. 2004;8:130–8.PubMed
32.
Zurück zum Zitat Hahnel S, Henrich A, Bürgers R, Handel G, Rosentritt M. Investigation of mechanical properties of modern dental composites after artificial aging for one year. Oper Dent. 2010;35:412–9.CrossRefPubMed Hahnel S, Henrich A, Bürgers R, Handel G, Rosentritt M. Investigation of mechanical properties of modern dental composites after artificial aging for one year. Oper Dent. 2010;35:412–9.CrossRefPubMed
33.
Zurück zum Zitat Assunção WG, Gomes EA, Barão VA, Barbosa DB, Delben JA, Tabata LF. Effect of storage in artificial saliva and thermal cycling on Knoop hardness of resin denture teeth. J Prosthodont Res. 2010;54:123–7.CrossRefPubMed Assunção WG, Gomes EA, Barão VA, Barbosa DB, Delben JA, Tabata LF. Effect of storage in artificial saliva and thermal cycling on Knoop hardness of resin denture teeth. J Prosthodont Res. 2010;54:123–7.CrossRefPubMed
34.
Zurück zum Zitat Weir MD, Moreau JL, Levine ED, Strassler HE, Chow LC, Xu HH. Nanocomposite containing CaF(2) nanoparticles: thermal cycling, wear and long-term water-aging. Dent Mater. 2012;28:642–52.CrossRefPubMedPubMedCentral Weir MD, Moreau JL, Levine ED, Strassler HE, Chow LC, Xu HH. Nanocomposite containing CaF(2) nanoparticles: thermal cycling, wear and long-term water-aging. Dent Mater. 2012;28:642–52.CrossRefPubMedPubMedCentral
35.
Zurück zum Zitat Kawano F, Ohguri T, Ichikawa T, Matsumoto N. Influence of thermal cycles in water on flexural strength of laboratory-processed composite resin. J Oral Rehabil. 2001;28:703–7.CrossRefPubMed Kawano F, Ohguri T, Ichikawa T, Matsumoto N. Influence of thermal cycles in water on flexural strength of laboratory-processed composite resin. J Oral Rehabil. 2001;28:703–7.CrossRefPubMed
36.
Zurück zum Zitat Kim AR, Jeon YC, Jeong CM, Yun MJ, Choi JW, Kwon YH, Huh JB. Effect of activation modes on the compressive strength, diametral tensile strength and microhardness of dual-cured self-adhesive resin cements. Dent Mater J. 2016;35:298–308.CrossRefPubMed Kim AR, Jeon YC, Jeong CM, Yun MJ, Choi JW, Kwon YH, Huh JB. Effect of activation modes on the compressive strength, diametral tensile strength and microhardness of dual-cured self-adhesive resin cements. Dent Mater J. 2016;35:298–308.CrossRefPubMed
37.
Zurück zum Zitat Versluis A, Douglas WH, Sakaguchi RL. Thermal expansion coefficient of dental composites measured with strain gauges. Dent Mater. 1996;12:290–4.CrossRefPubMed Versluis A, Douglas WH, Sakaguchi RL. Thermal expansion coefficient of dental composites measured with strain gauges. Dent Mater. 1996;12:290–4.CrossRefPubMed
38.
Zurück zum Zitat Morresi AL, D'Amario M, Capogreco M, Gatto R, Marzo G, D'Arcangelo C, Monaco A. Thermal cycling for restorative materials: does a standardized protocol exist in laboratory testing? A literature review. J Mech Behav Biomed Mater. 2014;29:295–308.CrossRefPubMed Morresi AL, D'Amario M, Capogreco M, Gatto R, Marzo G, D'Arcangelo C, Monaco A. Thermal cycling for restorative materials: does a standardized protocol exist in laboratory testing? A literature review. J Mech Behav Biomed Mater. 2014;29:295–308.CrossRefPubMed
39.
Zurück zum Zitat Nakamura T, Wakabayashi K, Kinuta S, Nishida H, Miyamae M, Yatani H. Mechanical properties of new self-adhesive resin-based cement. J Prosthodont Res. 2010;54:59–64.CrossRefPubMed Nakamura T, Wakabayashi K, Kinuta S, Nishida H, Miyamae M, Yatani H. Mechanical properties of new self-adhesive resin-based cement. J Prosthodont Res. 2010;54:59–64.CrossRefPubMed
Metadaten
Titel
Effect of aging and curing mode on the compressive and indirect tensile strength of resin composite cements
verfasst von
Nadja Rohr
Jens Fischer
Publikationsdatum
01.12.2017
Verlag
BioMed Central
Erschienen in
Head & Face Medicine / Ausgabe 1/2017
Elektronische ISSN: 1746-160X
DOI
https://doi.org/10.1186/s13005-017-0155-z

Weitere Artikel der Ausgabe 1/2017

Head & Face Medicine 1/2017 Zur Ausgabe

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.