Effect of Heliox- and Air-Driven Nebulized Bronchodilator Therapy on Lung Function in Patients with Asthma

Zeitschrift:
Lung > Ausgabe 3/2014
Autoren:
Mohamad F. El-Khatib, Ghassan Jamaleddine, Nadim Kanj, Salah Zeineddine, Hassan Chami, Imad Bou-Akl, Ahmad Husari, Marwan Alawieh, Pierre Bou-Khalil

Abstract

Background

This study compares the effect of heliox-driven to that of air-driven bronchodilator therapy on the pulmonary function test (PFT) in patients with different levels of asthma severity.

Methods

One-hundred thirty-two participants were included in the study. Participants underwent spirometry twice with bronchodilator testing on two consecutive days. Air-driven nebulization was used one day and heliox-driven nebulization the other day in random order crossover design. After a baseline PFT, each participant received 2.5 mg of albuterol sulfate nebulized with the randomized driving gas. Post bronchodilator PFT was repeated after 30 min. The next day, the exact same protocol was repeated, except that the other driving gas was used to nebulize the drug. Participants were subgrouped and analyzed according to their baseline FEV1 on day 1: Group I, FEV1 ≥80 %; Group II, 80 % > FEV1 > 50 %; Group III, FEV1 ≤50 %. The proportion of participants with greater than 12 % and 200-mL increases from their baseline FEV1 and the changes from baseline in PFT variables were compared between heliox-driven versus air-driven bronchodilation therapy.

Results

The proportion of participants with >12 % and 200-mL increases from their baseline FEV1 with air- or heliox-driven bronchodilation was not different with respect to the proportion of participants with baseline FEV1 ≥80 % (20 vs. 18 %, respectively) and 80 % > FEV1 > 50 % (36 vs. 43 %, respectively), but it was significantly greater with heliox-driven bronchodilation in participants with FEV1 ≤50 % (43 vs. 73 %, respectively; p = 0.01). Changes from baseline FVC, FEV1, FEV1/FVC, FEF25–75 %, FEFmax, FEF25 %, FEF50 %, and FEF75 % were significantly larger with heliox-driven versus air-driven bronchodilation in participants with baseline FEV1 ≤50 %.

Conclusion

Improvements in PFT variables are more frequent and profound with heliox-driven compared to air-driven bronchodilator therapy only in asthmatic patients with baseline FEV1 ≤50 %.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag als Mediziner

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 3/2014

Lung 3/2014 Zur Ausgabe
  1. Sie können e.Med Innere Medizin 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

  2. Sie können e.Med Allgemeinmedizin 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

Neu im Fachgebiet Innere Medizin

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Innere Medizin und bleiben Sie gut informiert – ganz bequem per eMail.

© Springer Medizin 

Bildnachweise