Skip to main content
Erschienen in: Clinical Oral Investigations 8/2014

01.11.2014 | Original Article

Effect of selective enamel etching on clinical performance of CAD/CAM partial ceramic crowns luted with a self-adhesive resin cement

verfasst von: Marianne Federlin, Karl-Anton Hiller, Gottfried Schmalz

Erschienen in: Clinical Oral Investigations | Ausgabe 8/2014

Einloggen, um Zugang zu erhalten

Abstract

Objectives

This study was conducted to evaluate a self-adhesive resin luting cement [RelyX Unicem 3MESPE–RXU] for luting partial ceramic crowns (PCCs) with and without selective enamel etching in a prospective, randomized clinical trial.

Materials and methods

Thirty-four patients had received the intended treatment. Two PCCs (Vita Mark II; Cerec 3D; Sirona) had been placed in a split-mouth design: one with RXU without enamel etching (RXU), the other with RXU with selective enamel etching (RXU + E). Restorations were evaluated at baseline (BL) and after 12, 24, and 36 months (USPHS criteria). For statistical analysis, the Chi-square test was applied (α = 0.05). Clinical survival of all restorations (n = 68) after 3 years was determined using Kaplan–Meier analysis.

Results

Twenty three patients (12 male/11 female) were available for clinical evaluation after 3 years. 19 RXU-PCCs were placed in molars, four in premolars, 18 RXU + E–PCCs in molars, five in premolars. Concerning clinical changes, no significant differences were found between luting strategies RXU/RXU + E at all recalls. Statistically significant changes over time were observed for marginal adaptation and marginal discoloration between BL and 36 m for RXU and RXU + E. For RXU + E, postoperative hypersensitivities decreased significantly from BL (n = 6) to 36 m (n = 0). Of the 68 restorations originally included, eight RXU and four RXU + E restorations failed. At 3 years, Kaplan–Meier survival of RXU was 72.9 %, that of RXU + E 87.6 %. Survival rates were not statistically significant different.

Conclusions

Although clinical survival of RXU + E is slightly better at 3 years, restorations of both groups perform similar with respect to clinical changes over time as evaluated by modified USPHS criteria.

Clinical relevance

The self-adhesive resin cement RXU can be used in conjunction with selective enamel etching, because survival rates of PCCs in the RXU + E group were not lower but, as a trend, even better than without enamel etching.
Literatur
1.
Zurück zum Zitat ADA Council on scientific affairs (2003) Tooth-colored restorative materials for posterior teeth. Acceptance program guidelines ADA Council on scientific affairs (2003) Tooth-colored restorative materials for posterior teeth. Acceptance program guidelines
2.
Zurück zum Zitat Aschenbrenner CM, Lang R, Handel G, Behr M (2012) Analysis of marginal adaptation and sealing to enamel and dentin of four self-adhesive resin cements. Clin Oral Investig 16:191–200PubMedCrossRef Aschenbrenner CM, Lang R, Handel G, Behr M (2012) Analysis of marginal adaptation and sealing to enamel and dentin of four self-adhesive resin cements. Clin Oral Investig 16:191–200PubMedCrossRef
3.
Zurück zum Zitat Behr M, Hansmann M, Rosentritt M, Handel G (2009) Marginal adaptation of three self-adhesive resin cements vs. a well-tried adhesive luting agent. Clin Oral Investig 13:459–464PubMedCrossRef Behr M, Hansmann M, Rosentritt M, Handel G (2009) Marginal adaptation of three self-adhesive resin cements vs. a well-tried adhesive luting agent. Clin Oral Investig 13:459–464PubMedCrossRef
4.
Zurück zum Zitat Belli R, Pelka M, Petschelt A, Lohbauer U (2009) In vitro wear gap formation of self–adhesive resin cements: a CLSM evaluation. J Dent 37:984–993PubMedCrossRef Belli R, Pelka M, Petschelt A, Lohbauer U (2009) In vitro wear gap formation of self–adhesive resin cements: a CLSM evaluation. J Dent 37:984–993PubMedCrossRef
5.
Zurück zum Zitat Burgess JO, Ghuman T, Cakir D (2010) Self-adhesive resin cements. J Esthet Restor Dent 22:412–419PubMedCrossRef Burgess JO, Ghuman T, Cakir D (2010) Self-adhesive resin cements. J Esthet Restor Dent 22:412–419PubMedCrossRef
6.
Zurück zum Zitat DeMunck J, Vargas M, Van Landuyt K, Hikita K, Lambrechts P, Van Meerbeek B (2004) Bonding of an auto-adhesive luting material to enamel and dentin. Dent Mater 20:963–971CrossRef DeMunck J, Vargas M, Van Landuyt K, Hikita K, Lambrechts P, Van Meerbeek B (2004) Bonding of an auto-adhesive luting material to enamel and dentin. Dent Mater 20:963–971CrossRef
7.
Zurück zum Zitat Federlin M, Krifka S, Herpich M, Hiller KA, Schmalz G (2007) Partial ceramic crowns: influence of ceramic thickness, preparation design and luting material on fracture resistance and marginal integrity in vitro. Oper Dent 32:251–260PubMedCrossRef Federlin M, Krifka S, Herpich M, Hiller KA, Schmalz G (2007) Partial ceramic crowns: influence of ceramic thickness, preparation design and luting material on fracture resistance and marginal integrity in vitro. Oper Dent 32:251–260PubMedCrossRef
8.
Zurück zum Zitat Federlin M, Schmidt S, Hiller KA, Thonemann B, Schmalz G (2004) Partial ceramic crowns: influence of preparation design and luting material on internal adaption. Oper Dent 29:560–570PubMed Federlin M, Schmidt S, Hiller KA, Thonemann B, Schmalz G (2004) Partial ceramic crowns: influence of preparation design and luting material on internal adaption. Oper Dent 29:560–570PubMed
9.
Zurück zum Zitat Federlin M, Sipos C, Hiller KA, Thonemann B, Schmalz G (2005) Partial ceramic crowns. Influence of preparation design and luting material on margin integrity—a scanning electron microscopic study. Clin Oral Investig 9:8–17PubMedCrossRef Federlin M, Sipos C, Hiller KA, Thonemann B, Schmalz G (2005) Partial ceramic crowns. Influence of preparation design and luting material on margin integrity—a scanning electron microscopic study. Clin Oral Investig 9:8–17PubMedCrossRef
10.
Zurück zum Zitat Federlin M, Hiller KA, Schmalz G (2010) Controlled, prospective clinical split-mouth study of cast gold vs. ceramic partial crowns: 5.5 year results. Am J Dent 23:161–167PubMed Federlin M, Hiller KA, Schmalz G (2010) Controlled, prospective clinical split-mouth study of cast gold vs. ceramic partial crowns: 5.5 year results. Am J Dent 23:161–167PubMed
11.
Zurück zum Zitat Felden A, Schmalz G, Federlin M, Hiller KA (1998) Retrospective clinical investigation and survival analysis on ceramic inlays and partial ceramic crowns: results up to 7 years. Clin Oral Investig 2:161–167PubMedCrossRef Felden A, Schmalz G, Federlin M, Hiller KA (1998) Retrospective clinical investigation and survival analysis on ceramic inlays and partial ceramic crowns: results up to 7 years. Clin Oral Investig 2:161–167PubMedCrossRef
12.
Zurück zum Zitat Ferracane JL, Stansbury JW, Burke FJ (2011) Self-adhesive resin cements—chemistry, properties and clinical considerations. J Oral Rehabil 38:295–314PubMedCrossRef Ferracane JL, Stansbury JW, Burke FJ (2011) Self-adhesive resin cements—chemistry, properties and clinical considerations. J Oral Rehabil 38:295–314PubMedCrossRef
13.
Zurück zum Zitat Frankenberger R, Krämer N, Petschelt A (2000) Technique sensitivity of dentin bonding: effect of application mistakes on bond strength and marginal adaptation. Oper Dent 25:324–330PubMed Frankenberger R, Krämer N, Petschelt A (2000) Technique sensitivity of dentin bonding: effect of application mistakes on bond strength and marginal adaptation. Oper Dent 25:324–330PubMed
15.
Zurück zum Zitat Frankenberger R, Taschner M, Garcia-Godoy F, Petschelt A, Krämer N (2008) Leucite-reinforced glass ceramic inlays and onlays after 12 years. J Adhes Dent 10:393–398PubMed Frankenberger R, Taschner M, Garcia-Godoy F, Petschelt A, Krämer N (2008) Leucite-reinforced glass ceramic inlays and onlays after 12 years. J Adhes Dent 10:393–398PubMed
16.
Zurück zum Zitat Frankenberger R, Lohbauer U, Roggendorf MJ, Naumann M, Taschner M (2008) Selective enamel etching reconsidered: better than etch-and-rinse and self-etch? J Adhes Dent 10:339–344PubMed Frankenberger R, Lohbauer U, Roggendorf MJ, Naumann M, Taschner M (2008) Selective enamel etching reconsidered: better than etch-and-rinse and self-etch? J Adhes Dent 10:339–344PubMed
17.
Zurück zum Zitat Gerth H, Dammaschke T, Zücher H, Schäfer E (2006) Chemical analysis and bonding reaction of RelyX Unicem and Bifix composites. A comparative study. Dent Mater 22:934–941PubMedCrossRef Gerth H, Dammaschke T, Zücher H, Schäfer E (2006) Chemical analysis and bonding reaction of RelyX Unicem and Bifix composites. A comparative study. Dent Mater 22:934–941PubMedCrossRef
18.
Zurück zum Zitat Goracci C, Cury AH, Cantoro A, Papacchini F, Tay FR, Ferrari M (2006) Microtensile bond strength and interfacial properties of self-etching and self-adhesive resin cements used to lute composite onlays under different seating forces. J Adhes Dent 8:327–335PubMed Goracci C, Cury AH, Cantoro A, Papacchini F, Tay FR, Ferrari M (2006) Microtensile bond strength and interfacial properties of self-etching and self-adhesive resin cements used to lute composite onlays under different seating forces. J Adhes Dent 8:327–335PubMed
19.
Zurück zum Zitat Hitz T, Stawarczyk B, Fischer J, Hammerle CH, Sailer I (2012) Are self-adhesive resin cements a valid alternative to conventional resin cements? A laboratory study of the long-term bond strength. Dent Mater 28:1183–1190PubMedCrossRef Hitz T, Stawarczyk B, Fischer J, Hammerle CH, Sailer I (2012) Are self-adhesive resin cements a valid alternative to conventional resin cements? A laboratory study of the long-term bond strength. Dent Mater 28:1183–1190PubMedCrossRef
20.
Zurück zum Zitat Ilie N, Simon A (2012) Effect of curing mode on the micro-mechanical properties of dual-cured self-adhesive resin cements. Clin Oral Investig 16:505–512PubMedCrossRef Ilie N, Simon A (2012) Effect of curing mode on the micro-mechanical properties of dual-cured self-adhesive resin cements. Clin Oral Investig 16:505–512PubMedCrossRef
21.
Zurück zum Zitat Krämer N, Frankenberger R (2005) Clinical performance of bonded leucit-reinforced glass ceramic inlays and onlays after eight years. Dent Mater 21:262–271PubMedCrossRef Krämer N, Frankenberger R (2005) Clinical performance of bonded leucit-reinforced glass ceramic inlays and onlays after eight years. Dent Mater 21:262–271PubMedCrossRef
22.
Zurück zum Zitat Krämer N, Frankenberger R, Pelka M, Petschelt A (1999) IPS empress inlays and onlays after four years—a clinical study. J Dent 27:325–331PubMedCrossRef Krämer N, Frankenberger R, Pelka M, Petschelt A (1999) IPS empress inlays and onlays after four years—a clinical study. J Dent 27:325–331PubMedCrossRef
23.
Zurück zum Zitat Krejci I, Krejci D, Lutz F (1992) Clinical evaluation of a new pressed glass ceramic inlay material over 1.5 years. Quintessence Int 23:181–186PubMed Krejci I, Krejci D, Lutz F (1992) Clinical evaluation of a new pressed glass ceramic inlay material over 1.5 years. Quintessence Int 23:181–186PubMed
24.
Zurück zum Zitat Lin J, Shinya A, Gomi H, Shinya A (2010) Bonding of self-adhesive resin cements to enamel using different surface treatments: bond strength and etching pattern evaluations. Dent Mater J 29:425–432PubMedCrossRef Lin J, Shinya A, Gomi H, Shinya A (2010) Bonding of self-adhesive resin cements to enamel using different surface treatments: bond strength and etching pattern evaluations. Dent Mater J 29:425–432PubMedCrossRef
25.
Zurück zum Zitat Moher D, Hopewell S, Schulz KF, Montori V, Gotzsche PC, Devereaux PJ, Elbourne D, Egger M, Altman DG (2010) CONSORT 2010 explanation and elaboration: updated guidelines for reporting parallel group randomised trials. BMJ 340:c869PubMedCrossRefPubMedCentral Moher D, Hopewell S, Schulz KF, Montori V, Gotzsche PC, Devereaux PJ, Elbourne D, Egger M, Altman DG (2010) CONSORT 2010 explanation and elaboration: updated guidelines for reporting parallel group randomised trials. BMJ 340:c869PubMedCrossRefPubMedCentral
26.
Zurück zum Zitat Mörmann WH, Götsch T, Krejci I, Lutz F, Barbakow F (1991) Clinical status of 94 Cerec ceramic inlays after 3 years in situ. In: Mörmann WH (ed) International symposium on computer restorations. The state of the art of the Cerec method (Proceedings). Quintessenz, Berlin, pp 355–363 Mörmann WH, Götsch T, Krejci I, Lutz F, Barbakow F (1991) Clinical status of 94 Cerec ceramic inlays after 3 years in situ. In: Mörmann WH (ed) International symposium on computer restorations. The state of the art of the Cerec method (Proceedings). Quintessenz, Berlin, pp 355–363
27.
Zurück zum Zitat Needleman I, Worthington H, Moher D, Schulz K, Altmann DG (2008) Improving the completeness and transparency of reports of randomized trials in oral health. Am J Dent 21:7–12PubMed Needleman I, Worthington H, Moher D, Schulz K, Altmann DG (2008) Improving the completeness and transparency of reports of randomized trials in oral health. Am J Dent 21:7–12PubMed
28.
Zurück zum Zitat Peumans M, Voet M, De Munck J, Van Landuyt K, Van Ende A, Van Meerbeek B (2013) Four-year clinical evaluation of a self-adhesive luting agent for ceramic inlays. Clin Oral Investig 17:739–750PubMedCrossRef Peumans M, Voet M, De Munck J, Van Landuyt K, Van Ende A, Van Meerbeek B (2013) Four-year clinical evaluation of a self-adhesive luting agent for ceramic inlays. Clin Oral Investig 17:739–750PubMedCrossRef
29.
Zurück zum Zitat Peutzfeldt A, Sahafi A, Flury S (2011) Bonding of restorative materials to dentin with various luting agents. Oper Dent 36:266–273PubMedCrossRef Peutzfeldt A, Sahafi A, Flury S (2011) Bonding of restorative materials to dentin with various luting agents. Oper Dent 36:266–273PubMedCrossRef
30.
31.
Zurück zum Zitat Saskalauskaite E, Tam LE, McComb D (2008) Flexural strength, elastic modulus, and pH profile of self-etch resin luting cements. J Prosthodont 17:262–268PubMedCrossRef Saskalauskaite E, Tam LE, McComb D (2008) Flexural strength, elastic modulus, and pH profile of self-etch resin luting cements. J Prosthodont 17:262–268PubMedCrossRef
32.
Zurück zum Zitat Saxer UP, Muhlemann HR (1975) Motivation and education. SSO Schweiz Monatsschr Zahnheilkd 85:905–919PubMed Saxer UP, Muhlemann HR (1975) Motivation and education. SSO Schweiz Monatsschr Zahnheilkd 85:905–919PubMed
33.
Zurück zum Zitat Schenke F, Hiller KA, Schmalz G, Federlin M (2008) Marginal integrity of partial ceramic crowns within dentin with differnet luting techniques and materials. Oper Dent 33–5:516–525CrossRef Schenke F, Hiller KA, Schmalz G, Federlin M (2008) Marginal integrity of partial ceramic crowns within dentin with differnet luting techniques and materials. Oper Dent 33–5:516–525CrossRef
34.
Zurück zum Zitat Schenke F, Federlin M, Hiller KA, Moder D, Schmalz G (2010) Controlled, prospective, randomized, clinical evaluation of partial ceramic crowns inserted with RelyX Unicem with or without selective enamel etching. 1-year results. Am J Dent 23:240–246PubMed Schenke F, Federlin M, Hiller KA, Moder D, Schmalz G (2010) Controlled, prospective, randomized, clinical evaluation of partial ceramic crowns inserted with RelyX Unicem with or without selective enamel etching. 1-year results. Am J Dent 23:240–246PubMed
35.
Zurück zum Zitat Schenke F, Federlin M, Hiller KA, Moder D, Schmalz G (2012) Controlled, prospective, randomized, clinical evaluation of partial ceramic crowns inserted with RelyX Unicem with or without selective enamel etching. Results after 2 years. Clin Oral Investig 16:451–461PubMedCrossRef Schenke F, Federlin M, Hiller KA, Moder D, Schmalz G (2012) Controlled, prospective, randomized, clinical evaluation of partial ceramic crowns inserted with RelyX Unicem with or without selective enamel etching. Results after 2 years. Clin Oral Investig 16:451–461PubMedCrossRef
36.
37.
Zurück zum Zitat Stamatacos C, Simon JF (2013) Cementation of indirect restorations: an overview of resin cements. Compend Contin Educ Dent 34(42–4):46 Stamatacos C, Simon JF (2013) Cementation of indirect restorations: an overview of resin cements. Compend Contin Educ Dent 34(42–4):46
38.
Zurück zum Zitat Studer SP, Lehner C, Brodbeck U, Schärer P (1996) Short-term results of IPS Empress inlays and onlays. J Prosthod 5:277–287CrossRef Studer SP, Lehner C, Brodbeck U, Schärer P (1996) Short-term results of IPS Empress inlays and onlays. J Prosthod 5:277–287CrossRef
39.
Zurück zum Zitat Taschner M, Kramer N, Lohbauer U, Pelka M, Breschi L, Petschelt A, Frankenberger R (2012) Leucite-reinforced glass ceramic inlays luted with self-adhesive resin cement: a 2-year in vivo study. Dent Mater 28:535–540PubMedCrossRef Taschner M, Kramer N, Lohbauer U, Pelka M, Breschi L, Petschelt A, Frankenberger R (2012) Leucite-reinforced glass ceramic inlays luted with self-adhesive resin cement: a 2-year in vivo study. Dent Mater 28:535–540PubMedCrossRef
40.
Zurück zum Zitat Tobi H, Kreulen CM, Gruythuysen RJ, van Amerongen WE (1998) The analysis of restoration survival data in split-mouth designs. J Dent 26(4):293–298PubMedCrossRef Tobi H, Kreulen CM, Gruythuysen RJ, van Amerongen WE (1998) The analysis of restoration survival data in split-mouth designs. J Dent 26(4):293–298PubMedCrossRef
41.
Zurück zum Zitat Van Landuyt KL, Kanumilli P, De MJ, Peumans M, Lambrechts P, Van MB (2006) Bond strength of a mild self-etch adhesive with and without prior acid-etching. J Dent 34:77–85PubMedCrossRef Van Landuyt KL, Kanumilli P, De MJ, Peumans M, Lambrechts P, Van MB (2006) Bond strength of a mild self-etch adhesive with and without prior acid-etching. J Dent 34:77–85PubMedCrossRef
42.
Zurück zum Zitat Wagner J, Hiller KA, Schmalz G (2003) Long-term clinical performance and longevity of gold alloy vs ceramic partial crowns. Clin Oral Investig 7:92–97CrossRef Wagner J, Hiller KA, Schmalz G (2003) Long-term clinical performance and longevity of gold alloy vs ceramic partial crowns. Clin Oral Investig 7:92–97CrossRef
43.
Zurück zum Zitat Wilson AD, Prosser HJ, Powis DM (1983) Mechanism of adhesion of polyelectrolyte cements to hydroxyapatite. J Dent Res 590–592 Wilson AD, Prosser HJ, Powis DM (1983) Mechanism of adhesion of polyelectrolyte cements to hydroxyapatite. J Dent Res 590–592
Metadaten
Titel
Effect of selective enamel etching on clinical performance of CAD/CAM partial ceramic crowns luted with a self-adhesive resin cement
verfasst von
Marianne Federlin
Karl-Anton Hiller
Gottfried Schmalz
Publikationsdatum
01.11.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 8/2014
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-013-1173-2

Weitere Artikel der Ausgabe 8/2014

Clinical Oral Investigations 8/2014 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.