Effectiveness of an Acetabular Positioning Device in Primary Total Hip Arthroplasty

verfasst von: Douglas E. Padgett, Stephen L. Hendrix, Timothy S. Mologne, Drew A. Peterson, Keith A. Holley

Erschienen in: HSS Journal ® | Ausgabe 1/2005

Einloggen, um Zugang zu erhalten

Abstract

To evaluate the efficacy of a commercially available acetabular positioning device, we performed a prospective evaluation of 40 consecutive patients undergoing primary total hip arthroplasty. All surgery was performed by the same surgeon, in the same operating room, and on the same operating table. The acetabular positioning device was designed to place the component in 45° of abduction. At 6 weeks, all radiographs were evaluated by 3 investigators not involved with the surgery. Each radiograph was evaluated by each reviewer on 3 separate occasions, blinded to the findings of the other reviewer to assess interobserver and intraobserver variability. The mean cup abduction angle was 42.1°, with a range from 23° to 57° (SD 8.3°). Intraobserver and interobserver variability were 0.2 and 0.3°, respectively. The findings of this study demonstrate a wide variability in acetabular cup placement in primary total hip arthroplasty. We believe this is due to movement of the pelvis, which may occur during preparation, draping, and retracting during surgery. We feel surgeons should not rely solely on positioning devices when implanting the acetabular component in total hip arthroplasty. Identification of bone landmarks and determination of superolateral implant coverage noted on preoperative templating is advocated to improve the precision of component position.
Literatur
1.
Zurück zum Zitat Schulte, KR, Callaghan, JJ, Kelley, S, Johnston, RJ 1993The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-upJ Bone Joint Surg Am75961975PubMed Schulte, KR, Callaghan, JJ, Kelley, S, Johnston, RJ 1993The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-upJ Bone Joint Surg Am75961975PubMed
2.
Zurück zum Zitat Barrack, RL 2003Dislocation after total hip arthoplasty: Implant design and orientationJ Am Acad Orthop Surg118999PubMed Barrack, RL 2003Dislocation after total hip arthoplasty: Implant design and orientationJ Am Acad Orthop Surg118999PubMed
3.
Zurück zum Zitat Kennedy, JG, Rogers, WB, Soffe, KE, Sullivan, RJ, Griffen, DG, Sheehan, LJ 1998Effects of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear and component migrationJ Arthroplasty13530534CrossRefPubMed Kennedy, JG, Rogers, WB, Soffe, KE, Sullivan, RJ, Griffen, DG, Sheehan, LJ 1998Effects of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear and component migrationJ Arthroplasty13530534CrossRefPubMed
4.
Zurück zum Zitat Kligman, M, Roffman, M 2002The effect of abduction differences between cup and contralateral acetabular angle on polyethylene component wearOrthopaedics256567 Kligman, M, Roffman, M 2002The effect of abduction differences between cup and contralateral acetabular angle on polyethylene component wearOrthopaedics256567
5.
Zurück zum Zitat Lewinnek, GE, Lewis, JL, Tarr, R 1978Dislocations after total hip replacement arthroplastiesJ Bone Joint Surg Am60217220PubMed Lewinnek, GE, Lewis, JL, Tarr, R 1978Dislocations after total hip replacement arthroplastiesJ Bone Joint Surg Am60217220PubMed
6.
Zurück zum Zitat Kummer, FJ, Shah, S, Iyer, S, DiCesare, PE 1999The effect of acetabular cup orientations on limiting hip rotationJ Arthroplasty14509513CrossRefPubMed Kummer, FJ, Shah, S, Iyer, S, DiCesare, PE 1999The effect of acetabular cup orientations on limiting hip rotationJ Arthroplasty14509513CrossRefPubMed
7.
Zurück zum Zitat Gonzalez Della Valle, AG, Slullitel, G, Piccaluga, F, Salvati, EA 2005The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplastyJ Arthroplasty205158 Gonzalez Della Valle, AG, Slullitel, G, Piccaluga, F, Salvati, EA 2005The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplastyJ Arthroplasty205158
8.
Zurück zum Zitat Padgett, DE, Kull, L, Rosenberg, AG, Sumner, R, Galante, JO 1993Revision of the acetabular component without cement after total hip arthroplastyJ Bone Joint Surg Am75663673PubMed Padgett, DE, Kull, L, Rosenberg, AG, Sumner, R, Galante, JO 1993Revision of the acetabular component without cement after total hip arthroplastyJ Bone Joint Surg Am75663673PubMed
9.
Zurück zum Zitat Massin, P, Schmidt, L, Engh, CA 1989Evaluation of cementless acetabular component migration: an experimental studyJ Arthroplasty4245249PubMed Massin, P, Schmidt, L, Engh, CA 1989Evaluation of cementless acetabular component migration: an experimental studyJ Arthroplasty4245249PubMed
10.
Zurück zum Zitat Jaramaz, B, DiGioia, AM, Blackwell, M, Nickou, C 1998Computer assisted measurement of cup placement in total hip replacementClin Orthop Relat Res3547081CrossRefPubMed Jaramaz, B, DiGioia, AM, Blackwell, M, Nickou, C 1998Computer assisted measurement of cup placement in total hip replacementClin Orthop Relat Res3547081CrossRefPubMed
11.
Zurück zum Zitat Nogler, M, Kessler, O, Prassl, A, Donnelly, B, Streicher, R, Sledge, JB 2004Reduced variability of acetabular cup positioning with use of an imageless navigation systemClin Orthop Relat Res426159163CrossRefPubMed Nogler, M, Kessler, O, Prassl, A, Donnelly, B, Streicher, R, Sledge, JB 2004Reduced variability of acetabular cup positioning with use of an imageless navigation systemClin Orthop Relat Res426159163CrossRefPubMed
Metadaten
Titel
Effectiveness of an Acetabular Positioning Device in Primary Total Hip Arthroplasty
verfasst von
Douglas E. Padgett
Stephen L. Hendrix
Timothy S. Mologne
Drew A. Peterson
Keith A. Holley
Publikationsdatum
01.09.2005
Erschienen in
HSS Journal ® / Ausgabe 1/2005
Print ISSN: 1556-3316
Elektronische ISSN: 1556-3324
DOI
https://doi.org/10.1007/s11420-005-0109-z

Weitere Artikel der Ausgabe 1/2005

HSS Journal ® 1/2005 Zur Ausgabe

Radiology and Imaging Corner

Multiple Hereditary Exostoses

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.