Skip to main content
Erschienen in: Surgical Endoscopy 6/2006

01.06.2006 | Original Article

Efficacy and quality of vessel sealing

Comparison of a reusable with a disposable device and effects of clamp surface geometry and structure

verfasst von: S. Richter, O. Kollmar, M. K. Schilling, G. A. Pistorius, M. D. Menger

Erschienen in: Surgical Endoscopy | Ausgabe 6/2006

Einloggen, um Zugang zu erhalten

Abstract

Background

During the past few years, a variety of energy-based techniques for vessel ligation have been introduced. With the use of a porcine model and different devices for bipolar vessel sealing (BiClamp and LigaSure), we studied the impact of different clamp surface structures on the efficacy and quality of vessel sealing.

Methods

Eight Swabian Hall pigs underwent splenectomy, nephrectomy, salpingo-oophorectomy, and small bowel resection with the use of bipolar vessel sealing devices designed for open and laparoscopic surgery. Vessel sealing with clamps with a smooth (nonstructured) surface (BiClamp for open surgery and LigaSure for laparoscopic surgery) was compared to that of clamps with a structured (grooved, wafer-like) surface (BiClamp for laparoscopic surgery and LigaSure for open surgery). Measurements of sealed vessels (2- to 7-mm diameter) included the seal failure rate, instrument sticking, and heat-associated morphological vascular wall alterations.

Results

Analysis of seal failures did not reveal significant differences between the different devices for both open [BiClamp, 17.9% (17/95); LigaSure, 15.5% (11/71)] and laparoscopic surgery [BiClamp, 2.8% (1/36); LigaSure, 8.6% (3/35)]. Comparing all data of structured versus smooth clamp surfaces, the seal failure rate was lower using clamps with a structured (11.2%) compared to a smooth surface (15.4%). Instrument sticking and thermal spread were found to be significantly increased after sealing with structured surfaces, regardless of whether devices designed for open (p < 0.05 and p < 0.001, respectively) or laparoscopic surgery (p < 0.001 and p < 0.01, respectively) were used.

Conclusion

Clamps with a structured surface seem to be superior to those with a smooth surface for successful bipolar vessel sealing, as indicated by an increase of thermal spread. However, the more pronounced instrument sticking represents an undesired side effect and should encourage the search for more inert materials to further improve the sealing procedure.
Literatur
1.
Zurück zum Zitat Belli G, Fantini C, Ciciliano F, D’Agostino A, Barberio M (2003) Pancreaticoduodenectomy in portal hypertension: use of the LigaSure. J Hepatobiliary Pancreat Surg 10: 215–217PubMedCrossRef Belli G, Fantini C, Ciciliano F, D’Agostino A, Barberio M (2003) Pancreaticoduodenectomy in portal hypertension: use of the LigaSure. J Hepatobiliary Pancreat Surg 10: 215–217PubMedCrossRef
2.
Zurück zum Zitat Campbell PA, Cresswell AB, Frank TG, Cuschieri A (2003) Real-time thermography during energized vessel sealing and dissection. Surg Endosc 17: 1640–1645PubMedCrossRef Campbell PA, Cresswell AB, Frank TG, Cuschieri A (2003) Real-time thermography during energized vessel sealing and dissection. Surg Endosc 17: 1640–1645PubMedCrossRef
3.
Zurück zum Zitat Dubuc-Lissoir J (2003) Use of a new energy-based vessel ligation device during laparoscopic gynecologic oncologic surgery. Surg Endosc 17: 466–468PubMedCrossRef Dubuc-Lissoir J (2003) Use of a new energy-based vessel ligation device during laparoscopic gynecologic oncologic surgery. Surg Endosc 17: 466–468PubMedCrossRef
4.
Zurück zum Zitat Harold KL, Pollinger H, Matthews BD, Kercher KW, Sing RF, Heniford BT (2003) Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc 17: 1228–1230PubMedCrossRef Harold KL, Pollinger H, Matthews BD, Kercher KW, Sing RF, Heniford BT (2003) Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc 17: 1228–1230PubMedCrossRef
5.
Zurück zum Zitat Heniford BT, Matthews BD, Sing RF, Backus C, Pratt B, Greene FL (2001) Initial results with an electrothermal bipolar vessel sealer. Surg Endosc 15: 799–801PubMedCrossRef Heniford BT, Matthews BD, Sing RF, Backus C, Pratt B, Greene FL (2001) Initial results with an electrothermal bipolar vessel sealer. Surg Endosc 15: 799–801PubMedCrossRef
6.
Zurück zum Zitat Kennedy JS, Stranahan PL, Taylor KD, Chandler JG (1998) High-burst-strength, feedback-controlled bipolar vessel sealing. Surg Endosc 12: 876–878PubMedCrossRef Kennedy JS, Stranahan PL, Taylor KD, Chandler JG (1998) High-burst-strength, feedback-controlled bipolar vessel sealing. Surg Endosc 12: 876–878PubMedCrossRef
7.
Zurück zum Zitat Klioze SD, Poppas DP, Rooke CT, Choma TJ, Schlossberg SM (1994) Development and initial application of a real time thermal control system for laser tissue welding. J Urol 152: 744–7481PubMed Klioze SD, Poppas DP, Rooke CT, Choma TJ, Schlossberg SM (1994) Development and initial application of a real time thermal control system for laser tissue welding. J Urol 152: 744–7481PubMed
8.
Zurück zum Zitat Landman J, Kerbl K, Rehman J, Andreoni C, Humphrey PA, Collyer W, Olweny E, Sundaram C, Clayman RV (2003) Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model. J Urol 169: 697–700PubMedCrossRef Landman J, Kerbl K, Rehman J, Andreoni C, Humphrey PA, Collyer W, Olweny E, Sundaram C, Clayman RV (2003) Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model. J Urol 169: 697–700PubMedCrossRef
9.
Zurück zum Zitat Levy B, Emery L (2003) Randomized trial of suture versus electrosurgical bipolar vessel sealing in vaginal hysterectomy. Obstet Gynecol 102: 147–151PubMedCrossRef Levy B, Emery L (2003) Randomized trial of suture versus electrosurgical bipolar vessel sealing in vaginal hysterectomy. Obstet Gynecol 102: 147–151PubMedCrossRef
10.
Zurück zum Zitat Palazzo FF, Francis DL, Clifton MA (2002) Randomized clinical trial of LigaSure versus open haemorrhoidectomy. Br J Surg 89: 154–157PubMed Palazzo FF, Francis DL, Clifton MA (2002) Randomized clinical trial of LigaSure versus open haemorrhoidectomy. Br J Surg 89: 154–157PubMed
11.
Zurück zum Zitat Presthus JB, Brooks PG, Kirchhof N (2003) Vessel sealing using a pulsed bipolar system and open forceps. J Am Assoc Gynecol Laparosc 10: 528–533PubMedCrossRef Presthus JB, Brooks PG, Kirchhof N (2003) Vessel sealing using a pulsed bipolar system and open forceps. J Am Assoc Gynecol Laparosc 10: 528–533PubMedCrossRef
12.
Zurück zum Zitat Romano F, Caprotti R, Franciosi C, De Fina S, Colombo G, Sartori P, Uggeri F (2003) The use of LigaSure during pediatric laparoscopic splenectomy: a preliminary report. Pediatr Surg Int 19: 721–724PubMedCrossRef Romano F, Caprotti R, Franciosi C, De Fina S, Colombo G, Sartori P, Uggeri F (2003) The use of LigaSure during pediatric laparoscopic splenectomy: a preliminary report. Pediatr Surg Int 19: 721–724PubMedCrossRef
13.
Zurück zum Zitat Romano F, Caprotti R, Franciosi C, De Fina S, Colombo G, Uggeri F (2002) Laparoscopic splenectomy using LigaSure. Preliminary experience. Surg Endosc 16: 1608–1611PubMedCrossRef Romano F, Caprotti R, Franciosi C, De Fina S, Colombo G, Uggeri F (2002) Laparoscopic splenectomy using LigaSure. Preliminary experience. Surg Endosc 16: 1608–1611PubMedCrossRef
14.
Zurück zum Zitat Schulze S, Krisitiansen VB, Fischer Hansen B, Rosenberg J (2002) Sealing of cystic duct with bipolar electrocoagulation. Surg Endosc 16: 342–344PubMedCrossRef Schulze S, Krisitiansen VB, Fischer Hansen B, Rosenberg J (2002) Sealing of cystic duct with bipolar electrocoagulation. Surg Endosc 16: 342–344PubMedCrossRef
15.
Zurück zum Zitat Sengupta S, Webb DR (2001) Use of a computer-controlled bipolar diathermy system in radical prostatectomies and other open urological surgery. ANZ J Surg 71: 538–540PubMedCrossRef Sengupta S, Webb DR (2001) Use of a computer-controlled bipolar diathermy system in radical prostatectomies and other open urological surgery. ANZ J Surg 71: 538–540PubMedCrossRef
16.
Zurück zum Zitat Shamiyeh A, Schrenk P, Tulipan L, Vattay P, Bogner S, Wayand W (2002) A new bipolar feedback-controlled sealing system for closure of the cystic duct and artery. Surg Endosc 16: 812–813PubMedCrossRef Shamiyeh A, Schrenk P, Tulipan L, Vattay P, Bogner S, Wayand W (2002) A new bipolar feedback-controlled sealing system for closure of the cystic duct and artery. Surg Endosc 16: 812–813PubMedCrossRef
17.
Zurück zum Zitat Shigemura N, Akashi A, Nakagiri T (2002) New operative method for a giant bulla: sutureless and stapleless thoracoscopic surgery using the LigaSure system. Eur J Cardiothorac Surg 22: 646–648PubMedCrossRef Shigemura N, Akashi A, Nakagiri T (2002) New operative method for a giant bulla: sutureless and stapleless thoracoscopic surgery using the LigaSure system. Eur J Cardiothorac Surg 22: 646–648PubMedCrossRef
18.
Zurück zum Zitat Sigel B, Dunn MR (1965) The mechanism of blood vessel closure by high frequency electrocoagulation. Surg Gynecol Obstet 121: 823–831PubMed Sigel B, Dunn MR (1965) The mechanism of blood vessel closure by high frequency electrocoagulation. Surg Gynecol Obstet 121: 823–831PubMed
19.
Zurück zum Zitat Spivak H, Richardson WS, Hunter JG (1998) The use of bipolar cautery, laparosonic coagulating shears, and vascular clips for hemostasis of small and medium-sized vessels. Surg Endosc 12: 183–185PubMedCrossRef Spivak H, Richardson WS, Hunter JG (1998) The use of bipolar cautery, laparosonic coagulating shears, and vascular clips for hemostasis of small and medium-sized vessels. Surg Endosc 12: 183–185PubMedCrossRef
20.
Zurück zum Zitat Strasberg SM, Drebin JA, Linehan D (2002) Use of a bipolar vessel-sealing device for parenchymal transection during liver surgery. J Gastrointest Surg 6: 569–574PubMedCrossRef Strasberg SM, Drebin JA, Linehan D (2002) Use of a bipolar vessel-sealing device for parenchymal transection during liver surgery. J Gastrointest Surg 6: 569–574PubMedCrossRef
Metadaten
Titel
Efficacy and quality of vessel sealing
Comparison of a reusable with a disposable device and effects of clamp surface geometry and structure
verfasst von
S. Richter
O. Kollmar
M. K. Schilling
G. A. Pistorius
M. D. Menger
Publikationsdatum
01.06.2006
Erschienen in
Surgical Endoscopy / Ausgabe 6/2006
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-005-0380-6

Weitere Artikel der Ausgabe 6/2006

Surgical Endoscopy 6/2006 Zur Ausgabe

OriginalPaper

News and notices

Wie erfolgreich ist eine Re-Ablation nach Rezidiv?

23.04.2024 Ablationstherapie Nachrichten

Nach der Katheterablation von Vorhofflimmern kommt es bei etwa einem Drittel der Patienten zu Rezidiven, meist binnen eines Jahres. Wie sich spätere Rückfälle auf die Erfolgschancen einer erneuten Ablation auswirken, haben Schweizer Kardiologen erforscht.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Ureterstriktur: Innovative OP-Technik bewährt sich

19.04.2024 EAU 2024 Kongressbericht

Die Ureterstriktur ist eine relativ seltene Komplikation, trotzdem bedarf sie einer differenzierten Versorgung. In komplexen Fällen wird dies durch die roboterassistierte OP-Technik gewährleistet. Erste Resultate ermutigen.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.