Background
Bronchoscopic lung volume reduction (BLVR) was introduced in 2010 with the publication on the endobronchial valve (EBV) treatment for Emphysema Palliation Trial (VENT) [
1]. The EBV is a minimally invasive bronchoscopic device designed for lung volume reduction in patients with severe emphysema. Its primary characteristics include the ability to redirect airflow away from hyperinflated areas of the lung, promoting improved lung function and systemic relief. Although adverse events include pneumothorax, acute exacerbation of chronic obstructive pulmonary disease (COPD), and hemoptysis, the incidences are relatively low at less than 8%. The procedure improved lung function, exercise capacity, and respiratory symptoms [
1]. After the VENT trial, the absence of interlobar collateral ventilation (CV) was identified as an important predictor of response to BLVR [
2]. Subsequent studies among selected patients without collateral ventilation showed consistent improvements in clinical parameters and acceptable safety profiles [
3‐
5].
In 2018, the Zephyr endobronchial valve was approved by the United States Food and Drug Administration [
6]. Since then, EBV has become a treatment option for advanced emphysema recommended by GOLD [
7] and NICE [
8].
In Asian countries, the clinical application of EBV has been relatively scarcely reported. The first reports of EBV in Asia, published in 2015 [
9,
10], also showed improvements in lung function, exercise capacity, respiratory symptoms, and quality of life. Meanwhile, these studies also reported a higher complication rate of pneumothorax than that reported in studies conducted involving Western populations [
1,
2,
11]. The possible explanations include an older target population, lower body mass index (BMI), and poorer exercise capacity in the Asian target population. Despite lower forced expiratory volume in 1 s (FEV
1), hyperinflation, represented by residual volume, was less severe. The findings suggest some discrepancies in patient characteristics among ethnic groups, and thoracic cage morphology may be one of them [
12].
Furthermore, there are not enough long-term studies on BLVR including the Asian population. In this study, we collected clinical data of the entire population considered for treatment with EBV in Korea to confirm its long-term efficacy and safety in Korea.
Methods
Study design and study population
This retrospective multicenter cohort study included patients from Korea between July 2012 and July 2021. A total of 13 institutions had experience with EBV during the study period, and 11 of them provided the data. The number of omitted patients was less than 15 based on the market survey.
The inclusion criterion was bronchoscopic assessment for treatment with EBV. The two distinct indications for EBV insertion; i) bronchoscopic lung volume reduction (BLVR) in patients with emphysema and ii) persistent air-leak (PAL) in patients with a chest tube, were considered for the study. Patients were selected at the attending physician’s discretion.
For BLVR candidates, the presence of collateral ventilation (CV) was a primary exclusion criterion due to its negative impact on the treatment outcomes. Most institutes included patients with a minimum Modified Medical Research Council (mMRC) dyspnea scale score of 2; however, one institute included patients with an mMRC score of 1, justifying their inclusion based on their severe airflow limitation. CV status was assessed physiologically with the Chartis® Pulmonary Assessment System (PulmonX Corporation., Redwood City, CA, USA) and radiographically with computed tomography (CT)-fissure analysis. The Chartis system facilitated isolation of a target lobe using a balloon catheter, followed by measurement of airflow and pressure within the lobe. A key criterion for contraindicating BLVR was the detection of significant airflow in the lobe despite balloon occlusion, indicating substantial ventilation. Furthermore, BLVR was contraindicated if the fissure lengths were not clearly defined for 5–10% of their total length. Those who underwent bronchoscopy but did not receive EBV due to CV were classified into the no-BLVR group. All patients with persistent air-leak received treatment with EBV. The valves used in this study were Zephyr one-way EBV (PulmonX Corporation, Redwood City, CA, USA).
For the management of PAL, the treatment approach was uniformly inclusive across all centers. The assessment of collateral ventilation varied among the institutes; three utilized the Chartis system whereas the other three did not.
The present study was approved by the Institutional Review Board (IRB) of each institution. Due to the retrospective nature of the study, the need for informed consent was waived by the IRB of Asan Medical Center. The IRB protocol numbers are documented in the additional file (Additional file
1). The investigation was performed in accordance with the Declaration of Helsinki.
Data collection
The clinical and survival data were retrospectively collected from medical records. Patients were followed from the date of bronchoscopic assessment until death or the last date of follow-up. Collected data included demographics, comorbidities, treatment for the lung disease, pulmonary function test (PFT) results, radiographic findings, chronic obstructive pulmonary disease (COPD) assessment test results, mMRC Dyspnoea Scale score, 6-min walk distance, procedure-related details, clinical outcomes, and adverse events following the procedure. The adverse events included pneumothorax, hemoptysis, empyema, acute exacerbation of COPD, and mortality.
Effects after EBV insertion
Among patients requiring BLVR, all-cause mortality and incidents of acute exacerbation of COPD were evaluated. The events were compared between patients who received EBV and those who did not. Changes in FEV1 and radiographic findings before and after the index date were also compared. Changes in FEV1 were assessed by measuring differences in FEV1 before and after the index date. Lung volume reduction of the target lobe was assessed by the physicians at each participating study site. It was defined by a reduction of more than 50% in lung volume assessed through chest radiographs or chest CT scans obtained 6 months after the procedure. To ensure consistency and objectivity in these assessments, any cases of disagreement or ambiguity were resolved through a consensus decision made by JYH and SWL. Subgroup analyses of mortality and acute exacerbation were performed to determine the effects of response to BLVR. For patients with PAL treated off-label with EBV, we collected information on the air-leak etiology, specifics of the EBV procedure, the timing of chest tube removal, and any subsequent adverse events.
Statistical analysis
Data were analyzed using the Student’s t-test, Mann–Whitney U test, Wilcoxon’s signed-rank test, the χ2 test, Fisher’s exact test, or analysis of variance, as appropriate. Time-to-mortality and time-to-acute exacerbation were evaluated with Kaplan–Meier survival curves. Log-rank test was performed to compare the groups. Additionally, multivariate Cox proportional-hazard regression analyses were implemented. Variables with P < 0.20 in univariate analysis were selected for multivariate analysis.
A value of P < 0.05 was considered statistically significant (two-tailed). All statistical analyses were conducted using R Statistical Software (version 4.0.3; R Foundation for Statistical Computing, Vienna, Austria).
Discussion
In this analysis, we reviewed the cases of 210 patients assessed for EBV therapy, of which 155 underwent the procedure. Specifically, BLVR was performed in 137 out of 192 patients with severe emphysema who were evaluated as potential candidates. Notably, an independent predictor of improved overall survival was the radiographic evidence of lung volume reduction, as determined by visual estimation. Furthermore, in 18 patients with PAL, a majority (77.8%) exhibited clinical improvement following treatment with EBV.
Among patients with emphysema, we observed a larger increase in FEV
1 and a trend toward better survival in patients who underwent BLVR than in those who did not. The observed 20% improvement in FEV
1 after 3 months is consistent with previous studies, which have reported improvements ranging from 17 to 29% [
13]. Although we were unable to evaluate long-term changes in FEV
1 due to insufficient follow-up PFT data, the trend was sustained up to approximately 1 year. The multicenter randomized controlled LIBERATE trial showed an FEV
1 increase of 104 mL after a year of the treatment with EBV [
3]. Another recent study including 280 patients reported that the improvements in FEV
1 and other clinical outcome measures were maintained at least up to 3 years, albeit with a diminishing effect over time [
14].
Improved survival with BLVR has been consistently reported in the literature. In the subgroup analysis in the STELVIO study, Klooster et al. found that predictors of survival, the BODE index score, 6-min-walk distance, and hyperinflation improve after BLVR [
15]. In another retrospective cohort study comparing 483 patients in the BLVR group and 988 patients in the no-BLVR group, the median survival was longer in the BLVR group (median 3133 days vs. 2503 days;
P < 0.001) [
16].
BLVR treatment is usually performed in carefully selected patients with severe emphysema who remain symptomatic despite optimal medical treatment, show evidence of hyperinflation, and demonstrated absence of CV [
13,
17]. However, even among the carefully selected patients, treatment response is variable. In our subgroup analysis, we found radiographic reduction in lung volume assessed through visual estimation at 6 months interval to be an independent factor associated with better survival. Nonetheless, survival benefit was not observed without lung volume reduction (Fig.
2). Based on the result, we re-emphasize the importance of evaluating BLVR candidates for their potential to achieve lung volume reduction.
Studies on the off-label use of Zephyr EBV in patients with PAL is limited. However, most of the patients (82.4%) included in this study for PAL were able to have their chest tube removed after placement of EBVs. Similarly, an Italian multicenter retrospective study including 67 patients who had PAL after lung resection, reported a resolution rate of 88.0% after the treatment [
18]. Although the treatment success rate was lower in our cohort compared with that is previous studies, this was anticipated since we included all causes of PAL rather than limiting to post-surgical cases. Currently, the FDA has only approved the use of the intrabronchial valve (Spiration. Inc., Redmond, Washington, USA) for managing post-surgical prolonged air-leaks under the Human Device Exemption (HDE) program [
19]. Nevertheless, attempts to treat PAL of various causes with bronchoscopies continue, as PAL is detrimental, and its management is still controversial and challenging [
20‐
23]. Our study adds to the feasibility of managing PAL of different causes with EBV. However, further prospective studies with controlled protocols are warranted, especially for assessing treatment response in the presence of collateral ventilation.
Reports on BLVR from Asian countries, including Korea, Japan, and China, are limited. In Japan, BLVR techniques with autologous blood, thrombin or Spigot have been reported through case series or reports [
24,
25], and relatively common methods such as EBV or coil have not been published. In China, experimental devices including flap or occlude have been studied [
26,
27], alongside case reports [
28,
29] and single-arm studies evaluating the efficacy of endobronchial valve [
30,
31], showing improvements in lung function and exercise capacity. In Korea, after the early studies reporting the clinical outcomes of EBV insertion [
9,
10], studies on the improvement of ventilation-perfusion mismatch with BLVR and the utility of fissure integrity analyzed through quantitative CT to select EBV insertion sites were published [
32,
33]. Essentially, the present evidence of BLVR is mostly based on data from the non-Asian population. In this context, our study showed meaningful insights into BLVR, drawn from data obtained from more than two hundred patients with a median follow-up of 18.5 months, confirming the long-term efficacy and safety of this treatment in the Asian population.
In the general population, lung function differs among racial groups. Caucasians have larger total lung capacity, forced vital capacity, and FEV
1, whereas functional residual capacity and residual volume are similar [
34,
35]. Although the cause of the disparity is inconclusive, the differences have been attributed to anatomical distinctions. In a study comparing 13 Caucasians, 14 Chinese, and 11 Indian, the width and surface area of the Caucasian were found to be greater [
36]. Our study has shown BLVR can be implemented in Asian patients, despite the distinctions.
This study has few limitations. First, this is a retrospective review, limiting the evaluation of confirmative effectiveness. However, the inclusion of data from more than 90% of patients who underwent treatment in one countryprovides valuable insights into how this procedure was conducted and standardized after being introduced to the country. Second, the procedure was performed in 11 institutions, and the protocols were not standardized. For instance, while most institutions performed BLVR under local anesthesia after confirming the absence of CV using the Chartis system, one institution performed BLVR mostly under general anesthesia (35/41, 85.4%) without Chartis evaluation (28/41, 68.3%). Furthermore, the use of the Chartis system for patients with PAL varied as three of the six institutes used it and three did not. These differences can contribute in part to the results that survival benefit was only evident when the target lobar volume was reduced, and EBV insertion alone did not result in sufficient differences. Third, initially, we planned to incorporate the analysis of mMRC dyspnea scale and 6-min-walk distance test to assess functional improvements in patients following BLVR. However, due to the gaps in data, we were unable to evaluate serial changes in those outcomes. Instead, we focused on a comprehensive evaluation of PFT.
Publisher’s Note