Skip to main content
Erschienen in: European Journal of Applied Physiology 11-12/2019

Open Access 28.09.2019 | Original Article

Erythropoietic responses to a series of repeated maximal dynamic and static apnoeas in elite and non-breath-hold divers

verfasst von: Antonis Elia, Matthew J. Barlow, Kevin Deighton, Oliver J. Wilson, John P. O’Hara

Erschienen in: European Journal of Applied Physiology | Ausgabe 11-12/2019

Abstract

Purpose

Serum erythropoietin (EPO) concentration is increased following static apnoea-induced hypoxia. However, the acute erythropoietic responses to a series of dynamic apnoeas in non-divers (ND) or elite breath-hold divers (EBHD) are unknown.

Methods

Participants were stratified into EBHD (n = 8), ND (n = 10) and control (n = 8) groups. On two separate occasions, EBHD and ND performed a series of five maximal dynamic apnoeas (DYN) or two sets of five maximal static apnoeas (STA). Control performed a static eupnoeic (STE) protocol to control against any effects of water immersion and diurnal variation on EPO. Peripheral oxygen saturation (SpO2) levels were monitored up to 30 s post each maximal effort. Blood samples were collected at 30, 90, and 180 min after each protocol for EPO, haemoglobin and haematocrit concentrations.

Results

No between group differences were observed at baseline (p > 0.05). For EBHD and ND, mean end-apnoea SpO2 was lower in DYN (EBHD, 62 ± 10%, p = 0.024; ND, 85 ± 6%; p = 0.020) than STA (EBHD, 76 ± 7%; ND, 96 ± 1%) and control (98 ± 1%) protocols. EBHD attained lower end-apnoeic SpO2 during DYN and STA than ND (p < 0.001). Serum EPO increased from baseline following the DYN protocol in EBHD only (EBHD, p < 0.001; ND, p = 0.622). EBHD EPO increased from baseline (6.85 ± 0.9mlU/mL) by 60% at 30 min (10.82 ± 2.5mlU/mL, p = 0.017) and 63% at 180 min (10.87 ± 2.1mlU/mL, p = 0.024). Serum EPO did not change after the STA (EBHD, p = 0.534; ND, p = 0.850) and STE (p = 0.056) protocols. There was a significant negative correlation (r = − 0.49, p = 0.003) between end-apnoeic SpO2 and peak post-apnoeic serum EPO concentrations.

Conclusions

The novel findings demonstrate that circulating EPO is only increased after DYN in EBHD. This may relate to the greater hypoxemia achieved by EBHD during the DYN.
Hinweise
Communicated by Guido Ferretti.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

Hypoxia is a condition of reduced oxygen concentration in breathable air or blood. Elite breath-hold divers (EBHD) regularly endure periods of acute hypoxemia (oxygen saturation levels < 90%) during their training sessions, interspaced by periods of normal breathing (1–2 min). Breath-holding (apnoea) triggers a series of physiological modifications known as the diving reflex which collectively lower oxygen utilisation and in turn, prolong apnoeic durations. The diving reflex is characterised by an initial parasympathetically-induced bradycardial response (Schagatay and Holm 1996), followed by a sympathetically-induced peripheral vasoconstriction of non-vital organs and extremities (Campbell et al. 1969), with oxygenated blood preferentially redistributed to the vital organs (Sterba and Lundgren 1988).
During apnoeic periods, systemic hypoxemia is induced in renal vascular beds (Bron et al. 1966). This stimulates the release of the glycoprotein hormone erythropoietin (EPO) from the renal peritubular fibroblasts into the circulation (Elliott 2008; Jelkmann 2011). The magnitude of EPO release is directly proportional to the level of hypoxia (Eckardt et al. 1989; Knaupp et al. 1992), and the transcription of EPO is controlled, at the cellular level, by hypoxia-inducible transcription factors (Wang and Semenza 1993). EPO is responsible for activating the proliferation and maturation of red blood cells and haemoglobin (Eckardt et al. 1989; Jelkmann 1992; Lundby et al. 2007; Elliot 2008). Higher resting haemoglobin concentrations have been documented in breath-hold divers compared with untrained individuals (Richardson et al. 2005; Fernandez et al. 2017). It is possible that these differences may be influenced by the level of EPO hormone secreted by the kidneys into the systemic circulation in response to intermittent hypoxia, causing differentiation of the precursors that become haemoglobin-containing red blood cells.
To date, only two studies have investigated the erythropoietic effect of apnoea-induced hypoxia (de Bruijn et al. 2008; Kjeld et al. 2015). De Bruijn et al. (2008) first reported that a series of 15 maximal dry static apnoeas performed by a group of non-divers (ND) induced acute increases in serum EPO with peak values observed within 3 h (16% increase) of the last hypoxic bout and being restored to baseline 5 h post. More recently, Kjeld et al. (2015) reported significant increases in EPO (17%) 3 h after a single bout of a combined maximal static and dynamic apnoea attempt in a group of elite breath-hold divers (EBHD). However, a distinction between the individual physiological responses to static and dynamic apnoeas was not determined. Static and dynamic apnoeas are two fundamentally different disciplines. Although both require individuals to hold their breath during the time course of their maximal attempt, the physiological demands imposed differ substantially. Indeed, Overgaard et al. (2006) reported a greater heart rate and end-tidal carbon dioxide and lower end-tidal oxygen after dynamic apnoeas when compared to dry static apnoeas, despite the ~ 75% shorter apnoeic time period in the dynamic apnoeas. The addition of contractile activity during the state of dynamic apnoea imposes a significant challenge to the diving reflex where myocardial and skeletal muscle oxygen consumption is increased, and blood flow is redistributed to meet the competing needs of both the vital organs and recruited striated muscle. Therefore, it is tempting to speculate that the nature of dynamic apnoeas (i.e. apnoea and exercise) may induce a greater hypoxemic stress and consequently, upregulate the release of EPO.
Accordingly, this study aimed to make the first investigations into the individual erythropoietic effects of static and dynamic apnoeas performed by EBHD and ND. We hypothesise that the greater hypoxemia associated with dynamic apnoeas will stimulate greater EPO concentration compared with static apnoeas.

Materials and methods

Participants

Twenty-six male participants volunteered for this study and were differentiated into three groups including, EBHD, ND and control. EBHD had 6 ± 2 years of apnoea practice and their training regime consisted of 9 ± 1 h per week of apnoea-related activities (Table 1). All breath-hold divers were national team members, of which four were current and two former national record holders (Table 1). The ND were physically active individuals and had no prior breath-hold diving experience. The control group consisted of eight physically active individuals of which two of them were recruited from the ND group. Participants were healthy, non-smoking, habitual sea-level residents and provided written informed consent before the study. All experimental procedures were completed in accordance with declaration of Helsinki and institutional ethical approval.
Table 1
Mean (± SD) participant characteristics
Variables
EBHD (n= 8)
ND (n= 10)
Control (n= 8)
Height (m)
1.83 ± 0.05
1.82 ± 0.06
1.78 ± 0.09
Body mass (kg)
84 ± 12
85 ± 7
82 ± 11
Static apnoea (s)
376 ± 39
Dynamic apnoea without fins (m)
131 ± 41
Dynamic apnoea with fins (m)
193 ± 42

Experimental protocol

Participants reported to the laboratory after a 12 h fast and abstinence from caffeine and alcohol containing beverages. In addition, participants were instructed to refrain from physical activity and apnoea-related activities for 24 h prior to and during the testing day. All resting data were collected during a single laboratory visit.
Following arrival at the laboratory (~25 °C), participants’ anthropometric measurements were assessed, including height and body mass (Seca, Vogel & Halke, Hamburg, Germany) (Table 1).
Participants then underwent a 20-min supine resting period. Subsequently, resting peripheral oxygen saturation (SpO2) was assessed using a finger pulse oximeter placed on the left-hand index finger (Nellcor PM10N, Medtronic, MN, USA) followed by two whole blood samples being drawn from a suitable vein in the antecubital fossa of the participant’s arm (median cubital vein and basilica vein) to assess serum EPO (6 mL; BD Vacutainer, 367954, Plymouth, UK), haemoglobin and haematocrit concentrations (4 mL; BD Vacutainer, K2E EDTA, BD, Plymouth, UK).

Familiarisation session

Within 24 h of completing the baseline measurements, participants reported at the swimming facilities and a familiarisation session was performed. Participants were introduced to the static apnoea position (seated position immersed up to the neck) and the dynamic apnoea technique (horizontal underwater breast stroke swimming) and were familiarised to the trial conditions and requirements.

Static apnoea protocol

Within a week from completing the familiarisation session, participants reported at the swimming pool (~ 28 °C) premises as during the familiarisation visit. The static apnoea protocol consisted of the participants performing two sets of five maximal static apnoeas. The two sets were separated by a 10-min seated rest and each apnoea was separated by a 2-min resting period.
Participants were instructed to hold their breath after a deep but not maximal inspiration, without prior hyperventilation or glossopharyngeal pistoning. A 1-min warning was provided prior to commencing each apnoea, participants received a nose clip 30 s prior to the apnoea to reduce any oxygen or water inspiration or oxygen loss, and a 10 s countdown was provided prior to immersing their face underwater and commencing their maximal apnoeic attempt. During each breath hold, participants received verbal information and a physical signal (gentle tap on the shoulder) every 30 s. After each breath hold, participants underwent a 2-min resting period during which they were allowed to relax and breathe normally in a seated position, whilst remaining immersed in water up to the waist. This procedure was repeated five times per set with the apnoeic duration being recorded during each maximal attempt.
The participant’s SpO2 (Nellcor PM10N, Medtronic, MN, USA) was recorded at 10 s intervals until 30 s after the termination of their breath-hold (Fagoni et al. 2017).

Dynamic apnoea protocol

Within a week of completing the static apnoea protocol, participants reported at the swimming pool as in during the static apnoea protocol. The dynamic apnoea protocol consisted of performing five maximal dynamic apnoeas without fins, with each apnoeic repetition being separated by a 2-min seated rest (immersed in water up to the waist). The pre-apnoeic breathing protocol and data collection was replicated as in the static apnoea protocol with the exception that SpO2 was not measured during the maximal attempt but up to 30 s post the termination of each maximal attempt, due to practical implications. During each maximal dynamic apnoeic attempt the duration and distance covered was recorded.

Control protocol

To control against any possible effects of whole-body immersion in water and diurnal variation in serum EPO concentration, a control group performed a static eupnoeic (normal breathing) protocol. The static eupnoeic protocol replicated the water exposure times, resting periods and data collection time points of the static apnoea protocol and replaced apnoeas with normal breathing periods. The static eupnoeic protocol was based on the static apnoeic protocol as the water exposure periods were longer in the static compared with the dynamic apnoea protocol.
Participants reported to the swimming pool facilities as during the apnoea measurements, at the same time period and were immersed in water up to the neck.

Post-apnoea blood sample

At completion of the apnoeic and control protocols, a cannula was inserted into a suitable median cubital or basilic vein of the participant’s arm and two blood samples were drawn at 30, 90 and 180 min after the last apnoeic/eupnoeic repetition to determine the level of circulating EPO (6 mL; BD Vacutainer, 367954, Plymouth, UK), haemoglobin and haematocrit (4 mL; BD Vacutainer, K2E EDTA, BD, Plymouth, UK).

Blood sample treatment and analysis

Samples for serum EPO were gently inverted, allowed to coagulate at room temperature for 20 min, and centrifuged (ALC Multispeed Refrigerated centrifuge, PK131R, London, United Kingdom) at 4000 rpm for 10 min at 4 °C. Samples were then aliquoted into 1.5 mL eppendorf tubes and stored at − 80 °C until an enzyme-linked immunosorbent assay analysis was performed (R&D systems, Quantikine IVD ELISA, Human Erythropoietin, DEP00, sensitivity 0.6 mIU/mL; intra-assay variability ~ 3.0%). For haemoglobin and haematocrit concentrations, samples were gently inverted for the EDTA to bind to calcium ions thus blocking the coagulation cascade and were analysed within 6 h of collection (Advia 2120i Haematology System, Siemens Healthcare, Surrey, UK; intra-assay variability ~ 1%).

Changes in plasma volume, blood volume and red cell volume

Plasma, blood and red cell volume changes for each post-apnoeic time point were determined using the methods of Dill and Costill (1974).

Statistical analysis

All participants completed the protocols successfully and all data were statistically analysed using the IBM SPSS statistics software version 21. The Shapiro–Wilk test was used to assess normality, whereas homogeneity was assessed using Levene’s test. Sphericity was assessed using Mauchly’s test of sphericity; where the assumption of sphericity was violated, the Greenhouse–Geisser correction was applied. Repeated measures ANOVA with post hoc contrast comparisons were used to assess differences between and within groups for baseline measurements and other collection time points for SpO2, serum EPO, haemoglobin and haematocrit concentrations. MANOVAS were used to assess differences in collection time points between groups (EBHD vs ND) and conditions (Static vs Dynamics vs Control). Pearson correlation was used to assess the relationship between end-apnoeic SpO2 and peak serum EPO concentrations, and to examine the relationship between post-apnoeic erythropoietin concentrations and plasma volume, blood volume and red cell volume. Where appropriate, effect size, partial eta squared (η2) and power (β) are also presented. Data are reported as means ± SD and significance was accepted at p < 0.05, and p = 0.000 was reported as p < 0.001. GraphPad Prism version 7.0c was used to construct figures.

Results

Control

Mean SpO2 was not significantly different from baseline (98 ± 1%) during the static eupnoeic protocol (98 ± 1%) (p = 1). There was a trend for serum EPO concentrations to gradually decrease from baseline concentrations (8.27 ± 3.63 mlU/mL) to 6.66 ± 1.55 mlU/mL (30 min), 5.95 ± 1.64 mlU/mL (90 min) and 5.34 ± 0.90 mlU/mL (180 min) post the completion of the static eupneic protocol (p = 0.056, partial η2 = 0.358).

Static apnoeas

Mean static apnoea duration was on average 67 ± 3% longer (p < 0.001, partial η2 = 0.744, β = 1) during each successive apnoeic attempt in EBHD than ND, with a mean duration of 218 ± 21 s (range from 130 to 350 s) in EBHD compared with 74 ± 7 s (range from 30 to 183 s) in ND, respectively.

Dynamic apnoeas

There was a between-group difference in distance covered during dynamic apnoeas (p < 0.001, partial η2 = 0.751, β = 1). The distance covered was 66 ± 4% longer in EBHD than ND during all apnoeic attempts with a mean distance covered of 66 ± 5 m (range from 46 to 126 m) compared with 22 ± 1 m (range from 14 to 37 m) in ND. Mean absolute apnoeic duration was significantly (p < 0.001, partial η2 = 0.641, β = 1) longer in EBHD (EBHD 94 ± 22 s) than ND (ND 42 ± 13 s).

Peripheral oxygen saturation

Mean SpO2 was significantly different from baseline during the static apnoea repetitions in EBHD (p < 0.001, partial η2 = 0.638, β = 0.992), but not in ND (p = 0.327, partial η2 = 0.131, β = 0.248). EBHD attained significantly lower SpO2 (p = 0.001, partial η2 = 0.558, β = 0.982) during each successive apnoeic repetition with a mean end-apnoeic SpO2 of 76 ± 5% compared to 96 ± 1% in ND. The dynamic apnoea protocol induced a significant decrease in mean SpO2 from baseline in both groups (EBHD, p < 0.001, partial η2 = 0.775, β = 1; ND, p < 0.001, partial η2 = 0.685, β = 1). EBHD reached significantly lower SpO2 (mean end-apnoeic SpO2 62 ± 10%) at all apnoeic repetitions when compared to ND (mean end-apnoeic SpO2 85 ± 6%) (p < 0.001, partial η2 = 0.693, β = 1). When the end-apnoeic SpO2 for each group was compared between protocols (static vs dynamic), significantly lower SpO2 were attained for both groups during the dynamic apnoea protocol (EBHD, p = 0.004, partial η2 = 0.456, β = 0.889; ND, p < 0.001, partial η2 = 0.566, β = 0.99). Significantly lower SpO2 levels were attained for both groups during dynamic apnoeas (p < 0.0001) versus the control protocol, whereas only the EBHD group reached significantly lower SpO2 levels during the static apnoea protocol versus the control protocol (EBHD, p < 0.0001, partial η2 = 0.467, β = 0.996; ND, p = 0.366, partial η2 = 0.066, β = 0.242).

Erythropoietin

Mean post-apnoeic EPO concentrations were not different from baseline during the static apnoea protocol for either groups (EBHD, p = 0.534, partial η2 = 0.097, β = 0.183; ND, p = 0.850, partial η2 = 0.006, β = 0.055) or when compared between groups (p = 0.471, partial η2 = 0.033, β = 0.107) (Fig. 2). Mean post-apnoeic EPO concentration was significantly different from baseline during the dynamic apnoea protocol in EBHD (p < 0.001, partial η2 = 0.584, β = 0.992) but not in ND (p = 0.622, partial η2 = 0.062, β = 0.157) (Fig. 1).
Specifically, serum EPO concentration was 60% higher than baseline (6.85 ± 0.9 mlU/mL) at 30 min (10.82 ± 2.5 mlU/mL, p = 0.017) and 63% higher at 180 min post-dynamic apnoeas (10.87 ± 2.1 mlU/mL, p = 0.024) in EBHD. There was a trend for increased EPO at 90 min post-apnoea (10.13 ± 2.0 mlU/mL, p = 0.058). In the EBHD group, there was inter-individual variability in the time to peak serum EPO concentration in response to dynamic apnoeas. Mean peak serum EPO concentration was 78 ± 43% (45–151%) higher than baseline after dynamic apnoeas (p = 0.001) in the EBHD. When the mean post-apnoeic EPO concentrations were compared between groups, the EBHD attained significantly higher EPO concentrations during all timepoints  when compared with the ND group (p = 0.002, partial η2 = 0.475, β = 0.946) (Fig. 1).
EPO concentrations were significantly higher in response to the dynamic versus static apnoea protocol in EBHD (p = 0.001, partial η2 = 0.548, β = 0.969) (Fig. 2), but EPO concentrations were not different between protocols in ND (p = 0.867, partial η2 = 0.002, β = 0.053). Additionally, EPO concentrations were significantly higher in response to the apnoeic protocols versus the control protocol in EBHD (Dynamics, p = 0.001, partial η2 = 0.548, β = 0.969; Statics, p = 0.043, partial η2 = 0.196, β = 0.595), whereas no differences were reported between protocols in ND (Dynamics, p = 0.066, partial η2 = 0.117, β = 0.484; Statics, p = 0.152, partial η2 = 0.117, β = 0.341) (Fig. 1).
There was a significant (p = 0.003) moderate negative correlation (r = − 0.49) between end-apnoeic SpO2 and peak post-apnoeic serum EPO concentrations (Fig. 2).

Haemoglobin and haematocrit

Mean post-apnoeic haemoglobin and haematocrit concentrations were not different from baseline during the static (haemoglobin, p = 0.136, haematocrit, p = 0.064) or dynamic (haemoglobin, p = 0.427, haematocrit, p = 0.522) apnoea protocol for either groups (Table 2).
Table 2
Change in mean haemoglobin (g/dl) and haematocrit (%) (mlU/mL) concentrations from baseline to 180 min post-apnoeas
Protocol
Haemoglobin (g/dl)
Haematocrit (%)
Baseline
30
90
180
Baseline
30
90
180
EBHD
 A
15 ± 0.60
14.54 ± 0.99
14.73 ± 1.05
15.01 ± 0.57
44 ± 1.62
42 ± 2.36
42 ± 2.77
42 ± 2.09
 B
14.96 ± 0.77
15.37 ± 1.79
15.17 ± 2.03
43 ± 2.62
42 ± 5.50
43 ± 6.06
ND
 A
14.9 ± 0.44
14.81 ± 0.56
14.68 ± 0.57
14.67 ± 0.51
45 ± 1.76
44 ± 2
44 ± 1.66
44 ± 1.32
 B
14.83 ± 0.74
14.57 ± 0.91
14.71 ± 0.86
45 ± 3.30
44 ± 4.08
44 ± 4.42
Data are presented as mean ± SD
A Static apnoea, B Dynamic apnoea, EBHD elite breath-hold divers, ND non-divers

Plasma volume, blood volume and red cell volume

Plasma volume, blood volume or red cell volume did not change for either protocol or group (p = 0.83). There was no relationship between post-apnoeic delta percentage change in EPO concentration and delta percentage change in plasma volume (r = − 0.052, p = 0.613), blood volume (r = 0.151, p = 0.122) or red cell volume (r = − 0.048, p = 0.643) (Fig. 3).

Discussion

This is the first study to make a novel distinction between the acute effects of static and dynamic apnoeas on erythropoietic responses in ND and EBHD. The primary findings were that: (1) dynamic apnoeas induced a more pronounced oxygen desaturation rate compared with static apnoeas, (2) which led into a significant increase in circulating EPO in EBHD only, (3) with no effect of static or eupnoea protocols on EPO. These findings confirm our hypothesis that a series of maximal dynamic apnoeas can elicit a greater hypoxemia than a series of maximal static apnoeas, and that the hypoxemia achieved during dynamic apnoeas is associated with a robust increase in circulating EPO.
Dynamic apnoeas induced a greater reduction in SpO2 than static apnoeas in both groups, despite significantly lower absolute apnoeic durations during the dynamic apnoea protocol compared with static apnoeas. These data suggest that tissue oxygen consumption was greater during repeated maximal dynamic apnoeas compared with repeated maximal static apnoeas, signifying that the addition of contractile activity during the state of apnoea imposes a greater hypoxemic stress. During both apnoeic protocols EBHD achieved significantly longer apnoeic durations and reached lower end-apnoeic SpO2 than ND. More experienced breath-hold divers, such as those recruited in the current study, are able to withstand the physiological breaking point, supress the urge to breathe and sustain prolonged apnoeic durations. As a consequence, EBHD are exposed to greater hypoxemic conditions during maximal apnoeic attempts than ND (Joulia et al. 2002). Evidence suggests the response of EBHD to apnoeas is trainable as Joulia et al. (2003) demonstrated that 3 months of apnoeic training significantly delayed the physiological breaking point, improved hypoxic tolerance and prolonged apnoeic durations.
To the best of our knowledge, this is the first study to report the erythropoietic responses to a series of maximal dynamic apnoeas performed by EBHD and ND. Increases in serum EPO in response to the dynamic apnoea protocol occurred only in the EBHD group, with no effect of the static apnoea or eupnoea protocol on EPO (Fig. 1). Additionally, there was no relationship between post-apnoeic EPO concentrations and blood volume, red cell volume or plasma volume (Fig. 3). Collectively, this suggests that the significant increases in serum EPO that occurred only in EBHD after completing the dynamic apnoea protocol were likely caused by the greater dynamic apnoea-induced hypoxia compared with ND and not by a circadian rhythm of EPO production, water immersion or due to haemoconcentration (Cahan et al. 1992; Klausen et al. 1996). In addition, in line with the literature, we identified for both groups (EBHD and ND) a moderate negative correlation between end-apnoeic SpO2 and peak post-apnoeic EPO concentrations (Fig. 2). Therefore, the lower SpO2 attained by the EBHD compared with ND during the dynamic apnoea protocol may have elicited a greater hypoxic stimulus for EPO release.
Despite the relative short (< 10 min), intermittent nature of the hypoxic exposures utilised in the current study, the observed serum EPO increases reported 3 h post (4.02 mlU/mL; 63% increase) a series of only five maximal dynamic apnoeas in EBHD are greater than those previously reported by de Bruijn et al. (2008) (1.38 mlU/mL; 16% increase) following a series of 15 maximal dry static apnoeas and by Kjeld et al. (2015) (1.8 mlU/mL; 17% increase) post a series of a combined maximal static and dynamic apnoea. The higher serum EPO concentrations observed in the present study, despite only one third of the number of apnoeas compared with de Bruijn et al. (2008), are probably attributed to the lower SpO2 levels attained by our EBHD group as a result of the longer apnoeic durations achieved. Additionally, the EBHD individual maximum serum EPO concentrations post the dynamic apnoea protocol are higher than those reported by Klausen et al. (1996) following 2 h of pokilocapnic hypoxia (28%, 8 ± 0.84 to 10.24 ± 0.95 mlU/mL) and by Ge et al. (2002) following 6 h at a simulated altitude of 2800 m and 24 h at 1780 m and 2085 m. However, it is currently unknown whether the present increases in serum EPO after repeated dynamic apnoeas, would ultimately translate to chronic increases in red blood cell mass and haemoglobin concentrations. Accordingly, future research should aim to investigate the longitudinal effects of dynamic apnoea training.
No differences in serum EPO from baseline were observed post the static apnoea protocol for either group (Fig. 1). This is contrary to de Bruijn et al. (2008) who demonstrated a 16% (1.38 mlU/L) increase 3 h post a series of repeated dry static apnoeas in ND. Although the lack of EPO release in our ND group may be explained by their lower end-apnoeic desaturation levels attained compared with de Bruijn et al. (2008) ND group, our breath-hold divers’ end-apnoeic SpO2 levels are comparable to those of de Bruijn et al. (2008). However, similarly to our ND group no significant erythropoietic differences were observed in the EBHD post the static apnoea protocol. This novel observation might suggest that chronic apnoeic training (exposure to prolonged and repetitive hypoxic periods) may attenuate the decrease in renal blood flow and subsequently suppress the release of EPO. Indeed, endurance training can attenuate the reduction of renal vascular blood flow at a given absolute work rate in humans and rodents (Clausen et al. 1973; Armstrong and Laughlin 1984; DiCarlo and Bishop 1990; Musch et al. 1991; Lash et al. 1993; Yen et al. 1995; Proctor et al. 2001). In rabbits, endurance exercise reduced renal sympathetic nerve activity, partly, due to enhanced cardiac baroreflex inhibition of sympathetic outflow to the mesenteric and renal circulation (DiCarlo et al. 1997; Mueller et al. 1998; De Moraes et al. 2004). Moreover, in vitro studies examining the conduit arteries and microcirculation of the renal vasculature revealed enhanced production of and/or sensitivity to endogenous endothelial dilators (Chen et al. 1999, 2001; Chies et al. 2004; De Moraes et al. 2004; Moyna and Thompson 2004). Collectively, the insignificant erythropoietic responses in our EBHD group following the static apnoea protocol might be explained by the training-induced renal adaptations and attenuation of renal vasoconstriction. However, further research is necessary to determine the extent to which our findings are the result of a training-induced adaptation of the renal vasculature.
In conclusion, we demonstrated that repeated maximal dynamic apnoeas significantly reduced SpO2 compared with static apnoeas in both EBHD and ND. Hypoxemia was greatest in EBHD in response to the dynamic apnoeas and this was associated with an increase in serum EPO in EBHD only. Accordingly, future research should aim to assess the longitudinal effects of dynamic apnoea training.

Acknowledgements

Open access funding provided by Royal Institute of Technology. We would like to thank all the participants who volunteered in the present research project.

Compliance with ethical standards

Conflict of interest

The authors have no conflict of interest to declare.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Allgemeinmedizin

Kombi-Abonnement

Mit e.Med Allgemeinmedizin erhalten Sie Zugang zu allen CME-Fortbildungen und Premium-Inhalten der allgemeinmedizinischen Zeitschriften, inklusive einer gedruckten Allgemeinmedizin-Zeitschrift Ihrer Wahl.

Literatur
Zurück zum Zitat Bron KM, Murdaugh HV Jr, Millen JE, Lenthall R, Raskin P, Robin ED (1966) Arterial constrictor response in a diving mammal. Science 152:540–543CrossRefPubMed Bron KM, Murdaugh HV Jr, Millen JE, Lenthall R, Raskin P, Robin ED (1966) Arterial constrictor response in a diving mammal. Science 152:540–543CrossRefPubMed
Zurück zum Zitat Chen Y, Collins HL, DiCarlo SE (1999) Daily exercise enhances acetylcholine-induced dilation in mesenteric and hindlimb vasculature of hypertensive rats. Clin Exp Hypertens 21:353–376CrossRefPubMed Chen Y, Collins HL, DiCarlo SE (1999) Daily exercise enhances acetylcholine-induced dilation in mesenteric and hindlimb vasculature of hypertensive rats. Clin Exp Hypertens 21:353–376CrossRefPubMed
Zurück zum Zitat Chies AB, de Oliveira AM, Pereira FC, de Andrade CR, Correa FM (2004) Phenylephrine-induced vasoconstriction of the rat superior mesenteric artery is decreased after repeated swimming. J Smooth Muscle Res 40:249–258CrossRefPubMed Chies AB, de Oliveira AM, Pereira FC, de Andrade CR, Correa FM (2004) Phenylephrine-induced vasoconstriction of the rat superior mesenteric artery is decreased after repeated swimming. J Smooth Muscle Res 40:249–258CrossRefPubMed
Zurück zum Zitat Fernández FdA, González-Ravé JM, Juárez D (2017) Breath-hold diving performance factors. J Hum Sport Ex 12:582–592 Fernández FdA, González-Ravé JM, Juárez D (2017) Breath-hold diving performance factors. J Hum Sport Ex 12:582–592
Zurück zum Zitat Ge RL, Witkowski S, Zhang Y et al (2002) Determinants of erythropoietin release in response to short-term hypobaric hypoxia. J Appl Physiol 92:2361–2367CrossRefPubMed Ge RL, Witkowski S, Zhang Y et al (2002) Determinants of erythropoietin release in response to short-term hypobaric hypoxia. J Appl Physiol 92:2361–2367CrossRefPubMed
Zurück zum Zitat Joulia F, Steinberg JG, Wolff F, Gavarry O, Jammes Y (2002) Reduced oxidative stress and blood lactic acidosis in trained breath-hold human divers. Respir Physiol Neurobiol 133:121–130CrossRefPubMed Joulia F, Steinberg JG, Wolff F, Gavarry O, Jammes Y (2002) Reduced oxidative stress and blood lactic acidosis in trained breath-hold human divers. Respir Physiol Neurobiol 133:121–130CrossRefPubMed
Zurück zum Zitat Joulia F, Steinberg JG, Faucher M, Jamin T, Ulmer C, Kipson N, Jammes Y (2003) Breath-hold training of humans reduces oxidative stress and blood acidosis after static and dynamic apnea. Respir Physiol Neurobiol 137:19–27CrossRefPubMed Joulia F, Steinberg JG, Faucher M, Jamin T, Ulmer C, Kipson N, Jammes Y (2003) Breath-hold training of humans reduces oxidative stress and blood acidosis after static and dynamic apnea. Respir Physiol Neurobiol 137:19–27CrossRefPubMed
Zurück zum Zitat Klausen T, Poulsen TD, Fogh-Andersen N, Richalet JP, Nielsen OJ, Olsen NV (1996) Diurnal variations of serum erythropoietin at sea level and altitude. Eur J Appl Physiol Occup Physiol 72:297–302CrossRefPubMed Klausen T, Poulsen TD, Fogh-Andersen N, Richalet JP, Nielsen OJ, Olsen NV (1996) Diurnal variations of serum erythropoietin at sea level and altitude. Eur J Appl Physiol Occup Physiol 72:297–302CrossRefPubMed
Zurück zum Zitat Richardson M, de Bruijn R, Holmberg HC, Bjorklund G, Haughey H, Schagatay E (2005) Increase of hemoglobin concentration after maximal apneas in divers, skiers, and untrained humans. Can J Appl Physiol 30:276–281CrossRefPubMed Richardson M, de Bruijn R, Holmberg HC, Bjorklund G, Haughey H, Schagatay E (2005) Increase of hemoglobin concentration after maximal apneas in divers, skiers, and untrained humans. Can J Appl Physiol 30:276–281CrossRefPubMed
Zurück zum Zitat Schagatay E, Holm B (1996) Effects of water and ambient air temperatures on human diving bradycardia. Eur J Appl Physiol Occup Physiol 73:1–6CrossRefPubMed Schagatay E, Holm B (1996) Effects of water and ambient air temperatures on human diving bradycardia. Eur J Appl Physiol Occup Physiol 73:1–6CrossRefPubMed
Zurück zum Zitat Sterba JA, Lundgren CE (1988) Breath-hold duration in man and the diving response induced by face immersion. Undersea Biomed Res 15:361–375PubMed Sterba JA, Lundgren CE (1988) Breath-hold duration in man and the diving response induced by face immersion. Undersea Biomed Res 15:361–375PubMed
Metadaten
Titel
Erythropoietic responses to a series of repeated maximal dynamic and static apnoeas in elite and non-breath-hold divers
verfasst von
Antonis Elia
Matthew J. Barlow
Kevin Deighton
Oliver J. Wilson
John P. O’Hara
Publikationsdatum
28.09.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Applied Physiology / Ausgabe 11-12/2019
Print ISSN: 1439-6319
Elektronische ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-019-04235-1

Weitere Artikel der Ausgabe 11-12/2019

European Journal of Applied Physiology 11-12/2019 Zur Ausgabe

Neu im Fachgebiet Arbeitsmedizin

Elterliches Belastungserleben, Unaufmerksamkeits‑/Hyperaktivitätssymptome und elternberichtete ADHS bei Kindern und Jugendlichen: Ergebnisse aus der KiGGS-Studie

Open Access ADHS Leitthema

Die Aufmerksamkeitsdefizit‑/Hyperaktivitätsstörung (ADHS) ist eine der häufigsten psychischen Störungen im Kindes- und Jugendalter [ 1 ]. In Deutschland beträgt die Prävalenz einer elternberichteten ADHS-Diagnose bei Kindern und Jugendlichen 4,4 % …

Substanzkonsum und Nutzung von sozialen Medien, Computerspielen und Glücksspielen unter Auszubildenden an beruflichen Schulen

Open Access Leitthema

Die Begrenzung von Schäden durch Substanzkonsum und andere abhängige Verhaltensweisen von Jugendlichen und jungen Erwachsenen ist ein wichtiges Anliegen der öffentlichen Gesundheit. Der Übergang von der Adoleszenz zum jungen Erwachsenenalter ist …

Berufsbelastung und Stressbewältigung von weiblichen und männlichen Auszubildenden

Leitthema

In der Öffentlichkeit wird die berufliche Ausbildung oftmals unter ökonomischen Gesichtspunkten diskutiert: Mit den geburtenstarken Jahrgängen gehen erfahrene Fachkräfte in Rente und von nachfolgenden Generationen rücken zu wenige Arbeitskräfte …

Rauschtrinken in der frühen Adoleszenz

COVID-19 Leitthema

Alkohol ist in Deutschland die mit Abstand am häufigsten konsumierte psychoaktive Substanz. Mehr als 2 Drittel aller Erwachsenen im Alter von 18 bis 64 Jahren (70,5 %) hat 2021 in den letzten 30 Tagen Alkohol konsumiert [ 1 ]. Von diesen …