Evaluation of the Sysmex XT-2000iV haematology analyser for rat, dog and mouse whole blood samples

verfasst von: R. A. Mathers, G. O. Evans, J. Bleby, T. Tornow

Erschienen in: Comparative Clinical Pathology | Ausgabe 3/2008

Einloggen, um Zugang zu erhalten

Abstract

The Sysmex XT-2000iV is a dedicated haematology analyser with full blood count, reticulocyte and five-population differential leucocyte capabilities for several laboratory animal species. The laboratory animal species chosen for this study were rat, dog and mouse. Results from dipotassium ethylenediamine tetraacetic acid (K2EDTA) samples from these species were compared with the laboratory’s established haematology analyser, the Bayer (now Siemens) Advia 120™ with multispecies software (Siemens Medical Solutions Diagnostics Europe Limited, Frimley, UK). Imprecision, carry-over between samples, linearity and stability data were also studied. In addition, results obtained for leucocyte differential counts were compared with standard manual 100-cell counts. Throughout this study, the Sysmex XT-2000iV proved to be robust, reliable and dependable. In summary, the Sysmex XT-2000iV has proved capable of accurately and precisely producing haematology results for animal species used within the pharmaceutical industry.
Literatur
Zurück zum Zitat Davies D, Fisher GV (1991) The validation and application of the Technicon H*1 for the complete automated evaluation of laboratory animal haematology. Comp Haematol Int 1:91–105CrossRef Davies D, Fisher GV (1991) The validation and application of the Technicon H*1 for the complete automated evaluation of laboratory animal haematology. Comp Haematol Int 1:91–105CrossRef
Zurück zum Zitat Evans GO, Smith DEC (1992) Preliminary studies with an SLS method for haemoglobin determination in three species. Comp Haematol Int 2:101–102CrossRef Evans GO, Smith DEC (1992) Preliminary studies with an SLS method for haemoglobin determination in three species. Comp Haematol Int 2:101–102CrossRef
Zurück zum Zitat Grimaldi E, Carandente P, Scopacasa F et al (2005) Evaluation of the monocyte counting by two automated haematology analysers compared to flow cytometry. Clin Lab Haematol 27:91–97PubMedCrossRef Grimaldi E, Carandente P, Scopacasa F et al (2005) Evaluation of the monocyte counting by two automated haematology analysers compared to flow cytometry. Clin Lab Haematol 27:91–97PubMedCrossRef
Zurück zum Zitat Hur M, Lee YK, Lee KM et al (2004) Pseudobasophilia as an erroneous white cell differential count with a discrepancy between automated cell counters: report of two cases. Clin Lab Haematol 26:287–290PubMedCrossRef Hur M, Lee YK, Lee KM et al (2004) Pseudobasophilia as an erroneous white cell differential count with a discrepancy between automated cell counters: report of two cases. Clin Lab Haematol 26:287–290PubMedCrossRef
Zurück zum Zitat ICSH (1994) International Council for the Standardization in Haematology. Guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte counting and cell marker applications. Clin Lab Haematol 16:157–174 ICSH (1994) International Council for the Standardization in Haematology. Guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte counting and cell marker applications. Clin Lab Haematol 16:157–174
Zurück zum Zitat Imazu M (2002) General description of the automated haematology analyser, XT-2000i. Sysmex J Int 12:13–17 Imazu M (2002) General description of the automated haematology analyser, XT-2000i. Sysmex J Int 12:13–17
Zurück zum Zitat Langford K, Luchtman-Jones L, Miller R et al (2003) Performance evaluation of the Sysmex XT-2000i automated haematology analyser. Lab Hematol 9:29–37PubMed Langford K, Luchtman-Jones L, Miller R et al (2003) Performance evaluation of the Sysmex XT-2000i automated haematology analyser. Lab Hematol 9:29–37PubMed
Zurück zum Zitat Mathers RA, Evans GO, Bleby J et al (2007) Total and differential leucocyte counts in rat and mouse bronchoalveolar lavage fluids using the Sysmex XT-2000iV. Comp Clin Pathol 16:29–39CrossRef Mathers RA, Evans GO, Bleby J et al (2007) Total and differential leucocyte counts in rat and mouse bronchoalveolar lavage fluids using the Sysmex XT-2000iV. Comp Clin Pathol 16:29–39CrossRef
Zurück zum Zitat Tvedten H (1994) Canine automated differential leukocyte count using a hematology analyser system. Vet Clin Pathol 23:90–97PubMedCrossRef Tvedten H (1994) Canine automated differential leukocyte count using a hematology analyser system. Vet Clin Pathol 23:90–97PubMedCrossRef
Zurück zum Zitat Zelmanovic D, Garcia RA, Leitner T et al (1993) H1*E multi-species haematology. Miles Science Journal 15:7–13 Zelmanovic D, Garcia RA, Leitner T et al (1993) H1*E multi-species haematology. Miles Science Journal 15:7–13
Metadaten
Titel
Evaluation of the Sysmex XT-2000iV haematology analyser for rat, dog and mouse whole blood samples
verfasst von
R. A. Mathers
G. O. Evans
J. Bleby
T. Tornow
Publikationsdatum
01.08.2008
Verlag
Springer-Verlag
Erschienen in
Comparative Clinical Pathology / Ausgabe 3/2008
Print ISSN: 1618-5641
Elektronische ISSN: 1618-565X
DOI
https://doi.org/10.1007/s00580-008-0734-2

Weitere Artikel der Ausgabe 3/2008

Comparative Clinical Pathology 3/2008 Zur Ausgabe

Neu im Fachgebiet Pathologie

Molekularpathologische Untersuchungen im Wandel der Zeit

Open Access Biomarker Leitthema

Um auch an kleinen Gewebeproben zuverlässige und reproduzierbare Ergebnisse zu gewährleisten ist eine strenge Qualitätskontrolle in jedem Schritt des Arbeitsablaufs erforderlich. Eine nicht ordnungsgemäße Prüfung oder Behandlung des …

Vergleichende Pathologie in der onkologischen Forschung

Pathologie Leitthema

Die vergleichende experimentelle Pathologie („comparative experimental pathology“) ist ein Fachbereich an der Schnittstelle von Human- und Veterinärmedizin. Sie widmet sich der vergleichenden Erforschung von Gemeinsamkeiten und Unterschieden von …

Gastrointestinale Stromatumoren

Open Access GIST CME-Artikel

Gastrointestinale Stromatumoren (GIST) stellen seit über 20 Jahren ein Paradigma für die zielgerichtete Therapie mit Tyrosinkinaseinhibitoren dar. Eine elementare Voraussetzung für eine mögliche neoadjuvante oder adjuvante Behandlung bei …

Personalisierte Medizin in der Onkologie

Aufgrund des erheblichen technologischen Fortschritts in der molekularen und genetischen Diagnostik sowie zunehmender Erkenntnisse über die molekulare Pathogenese von Krankheiten hat in den letzten zwei Jahrzehnten ein grundlegender …