Skip to main content
Erschienen in: International Ophthalmology 6/2013

01.12.2013 | Original Paper

Heat profiling of phacoemulsification tip using a thermal scanning camera

verfasst von: Wei Kiong Ngo, Louis W. Lim, Colin S. H. Tan, Wee Jin Heng

Erschienen in: International Ophthalmology | Ausgabe 6/2013

Einloggen, um Zugang zu erhalten

Abstract

An experimental study to measure the heat profile of the phacoemulsification (phaco) tip using standard continuous phaco and hyperpulse phaco with and without waveform power modulation in the Millennium Microsurgical System with Custom Control Software (CCS). The phaco tip was imaged in air using a thermal camera. The highest temperature was measured 15 s after application of phaco power. Continuous, hyperpulse and waveform power modulations of the Millennium Microsurgical System were used with different power settings (20, 50 and 100 %) and duty cycles (40, 60 and 90 %), with the irrigation turned on and off. Using continuous phaco with the irrigation on, the phaco tip temperature remains <28.0 °C. With irrigation off, the temperature is higher compared to irrigation on but still remains <45.0 °C. Comparing the temperatures for all three power modulations when irrigation is on, at each phaco power and duty cycle setting, the temperature of the phaco tip is highest with continuous phaco, followed by hyperpulse with rise time 1, then hyperpulse with rise time 2. When irrigation is off, the highest temperatures are recorded using the hyperpulse with rise time 2, followed by continuous phaco, then hyperpulse with rise time 1. Hyperpulse and waveform modulations reduce heat generation compared to the continuous mode when irrigation is turned on. Lower duty cycles and lower ultrasound power produce less heat at the phaco tip.
Literatur
1.
Zurück zum Zitat Sippel KC, Pineda R Jr (2002) Phacoemulsification and thermal wound injury. Semin Ophthalmol 17:102–109PubMedCrossRef Sippel KC, Pineda R Jr (2002) Phacoemulsification and thermal wound injury. Semin Ophthalmol 17:102–109PubMedCrossRef
2.
Zurück zum Zitat Ernest P, Rhem M, McDermott M, Lavery K, Sensoli A (2001) Phacoemulsification conditions resulting in thermal wound injury. J Cataract Refract Surg 27:1829–1839PubMedCrossRef Ernest P, Rhem M, McDermott M, Lavery K, Sensoli A (2001) Phacoemulsification conditions resulting in thermal wound injury. J Cataract Refract Surg 27:1829–1839PubMedCrossRef
3.
Zurück zum Zitat Bissen-Miyajima H, Shimmura S, Tsubota K (1999) Thermal effect on corneal incisions with different phacoemulsification ultrasonic tips. J Cataract Refract Surg 25:60–64PubMedCrossRef Bissen-Miyajima H, Shimmura S, Tsubota K (1999) Thermal effect on corneal incisions with different phacoemulsification ultrasonic tips. J Cataract Refract Surg 25:60–64PubMedCrossRef
4.
Zurück zum Zitat Olson MD, Miller KM (2005) In-air thermal imaging comparison of Legacy AdvanTec, Millennium, and Sovereign WhiteStar phacoemulsification systems. J Cataract Refract Surg 31:1640–1647PubMedCrossRef Olson MD, Miller KM (2005) In-air thermal imaging comparison of Legacy AdvanTec, Millennium, and Sovereign WhiteStar phacoemulsification systems. J Cataract Refract Surg 31:1640–1647PubMedCrossRef
5.
Zurück zum Zitat Soscia W, Howard JG, Olson RJ (2002) Bimanual phacoemulsification through 2 stab incisions. A wound-temperature study. J Cataract Refract Surg 28:1039–1043PubMedCrossRef Soscia W, Howard JG, Olson RJ (2002) Bimanual phacoemulsification through 2 stab incisions. A wound-temperature study. J Cataract Refract Surg 28:1039–1043PubMedCrossRef
6.
Zurück zum Zitat Mackool RJ, Sirota MA (2005) Thermal comparison of the AdvanTec Legacy, Sovereign WhiteStar, and Millennium phacoemulsification systems. J Cataract Refract Surg 31:812–817PubMedCrossRef Mackool RJ, Sirota MA (2005) Thermal comparison of the AdvanTec Legacy, Sovereign WhiteStar, and Millennium phacoemulsification systems. J Cataract Refract Surg 31:812–817PubMedCrossRef
7.
Zurück zum Zitat Soscia W, Howard JG, Olson RJ (2002) Microphacoemulsification with WhiteStar. A wound-temperature study. J Cataract Refract Surg 28:1044–1046PubMedCrossRef Soscia W, Howard JG, Olson RJ (2002) Microphacoemulsification with WhiteStar. A wound-temperature study. J Cataract Refract Surg 28:1044–1046PubMedCrossRef
Metadaten
Titel
Heat profiling of phacoemulsification tip using a thermal scanning camera
verfasst von
Wei Kiong Ngo
Louis W. Lim
Colin S. H. Tan
Wee Jin Heng
Publikationsdatum
01.12.2013
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 6/2013
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-013-9752-4

Weitere Artikel der Ausgabe 6/2013

International Ophthalmology 6/2013 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Ophthalmika in der Schwangerschaft

Die Verwendung von Ophthalmika in der Schwangerschaft und Stillzeit stellt immer eine Off-label-Anwendung dar. Ein Einsatz von Arzneimitteln muss daher besonders sorgfältig auf sein Risiko-Nutzen-Verhältnis bewertet werden. In der vorliegenden …

Operative Therapie und Keimnachweis bei endogener Endophthalmitis

Vitrektomie Originalie

Die endogene Endophthalmitis ist eine hämatogen fortgeleitete, bakterielle oder fungale Infektion, die über choroidale oder retinale Gefäße in den Augapfel eingeschwemmt wird [ 1 – 3 ]. Von dort infiltrieren die Keime in die Netzhaut, den …

Bakterielle endogene Endophthalmitis

Vitrektomie Leitthema

Eine endogene Endophthalmitis stellt einen ophthalmologischen Notfall dar, der umgehender Diagnostik und Therapie bedarf. Es sollte mit geeigneten Methoden, wie beispielsweise dem Freiburger Endophthalmitis-Set, ein Keimnachweis erfolgen. Bei der …

So erreichen Sie eine bestmögliche Wundheilung der Kornea

Die bestmögliche Wundheilung der Kornea, insbesondere ohne die Ausbildung von lichtstreuenden Narben, ist oberstes Gebot, um einer dauerhaften Schädigung der Hornhaut frühzeitig entgegenzuwirken und die Funktion des Auges zu erhalten.   

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.