Skip to main content
Erschienen in: Emergency Radiology 2/2019

01.04.2019 | Original Article

High-pitch versus standard mode CT pulmonary angiography: a comparison of indeterminate studies

verfasst von: Derrick A. Doolittle, Adam T. Froemming, Christian W. Cox

Erschienen in: Emergency Radiology | Ausgabe 2/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To compare the causes of indeterminate CT pulmonary angiograms using standard mode and high-pitch mode, and determine at what level of the pulmonary arterial tree studies were non-diagnostic.

Methods

IRB approval was obtained. A retrospective review of patients at our institution who underwent a CT pulmonary angiogram, between November 1, 2015 and February 10, 2016 was performed. CT pulmonary angiograms using both high-pitch mode and standard mode were evaluated with positive and indeterminate rates calculated. Causes of indeterminate studies and the level of the pulmonary arterial tree at which the study became non-diagnostic were determined by a board certified radiologist by looking at the images of each indeterminate study. The indeterminate rates were compared between high-pitch and standard modes using a generalized estimating equation.

Results

Five hundred fifty-nine CT pulmonary angiograms using high-pitch mode were evaluated, while 661 standard mode scans were evaluated. 69/559 (12.3%) scans with high-pitch mode were positive and 84/661 (12.7%) scans with standard mode were positive (not statistically significant, p > 0.05). There was a higher rate of indeterminate scans with standard mode compared to the high-pitch mode (80 [12.1%] standard vs. 25 [4.5%] high-pitch, p value < 0.0001). Findings were indeterminate at the lobar level in 4 (16%), at the segmental level in 11 (44%), and at the subsegmental level in 10 (40%) using high-pitch mode. The most common causes of an indeterminate scan using high-pitch mode were motion in 11 (44%), transient interruption of contrast in 6 (24%), and contrast timing in 5 (20%). Findings were indeterminate at the main pulmonary artery level in 1 (1.3%), at the lobar level in 13 (16.3%), at the segmental level in 28 (35.0%), and at the subsegmental level in 38 (47.5%) using the standard mode. The most common causes of an indeterminate scan using the standard mode were motion in 53 (66.3%), transient interruption of contrast in 19 (23.8%), and contrast timing in 15 (18.8%).

Conclusions

High-pitch mode results in statistically significant fewer indeterminate studies compared with standard mode. Furthermore, there were statistically significant fewer indeterminate studies due to motion artifact with high-pitch mode compared with standard mode.
Literatur
1.
Zurück zum Zitat Horlander KT, Mannino DM, Leeper KV (2003) Pulmonary embolism mortality in the United States, 1979-1998: an analysis using multiple-cause mortality data. Arch Intern Med 163(14):1711–1717CrossRefPubMed Horlander KT, Mannino DM, Leeper KV (2003) Pulmonary embolism mortality in the United States, 1979-1998: an analysis using multiple-cause mortality data. Arch Intern Med 163(14):1711–1717CrossRefPubMed
2.
3.
Zurück zum Zitat Zhang LJ, Lu GM, Meinel FG, McQuiston AD, Ravenel JG, Schoepf UJ (2015) Computed tomography of acute pulmonary embolism: state-of-the-art. Eur Radiol 25(9):2547–2557CrossRefPubMed Zhang LJ, Lu GM, Meinel FG, McQuiston AD, Ravenel JG, Schoepf UJ (2015) Computed tomography of acute pulmonary embolism: state-of-the-art. Eur Radiol 25(9):2547–2557CrossRefPubMed
4.
Zurück zum Zitat Achenbach S, Marwan M, Schepis T, Pflederer T, Bruder H, Allmendinger T, Petersilka M, Anders K, Lell M, Kuettner A, Ropers D, Daniel WG, Flohr T (2009) High-pitch spiral acquisition: a new scan mode for coronary CT angiography. J Cardiovasc Comput Tomogr 3(2):117–121CrossRefPubMed Achenbach S, Marwan M, Schepis T, Pflederer T, Bruder H, Allmendinger T, Petersilka M, Anders K, Lell M, Kuettner A, Ropers D, Daniel WG, Flohr T (2009) High-pitch spiral acquisition: a new scan mode for coronary CT angiography. J Cardiovasc Comput Tomogr 3(2):117–121CrossRefPubMed
5.
Zurück zum Zitat Lell M, Hinkmann F, Anders K, Deak P, Kalender WA, Uder M, Achenbach S (2009) High-pitch electrocardiogram-triggered computed tomography of the chest: initial results. Investig Radiol 44(11):728–733CrossRef Lell M, Hinkmann F, Anders K, Deak P, Kalender WA, Uder M, Achenbach S (2009) High-pitch electrocardiogram-triggered computed tomography of the chest: initial results. Investig Radiol 44(11):728–733CrossRef
6.
Zurück zum Zitat Sahani D, Saini S, D’Souza RV, O’Neill MJ, Prasad SR, Kalra MK, Halpern EF, Mueller P (2003) Comparison between low (3:1) and high (6:1) pitch for routine abdominal/pelvic imaging with multislice computed tomography. J Comput Assist Tomogr 27(2):105–109CrossRefPubMed Sahani D, Saini S, D’Souza RV, O’Neill MJ, Prasad SR, Kalra MK, Halpern EF, Mueller P (2003) Comparison between low (3:1) and high (6:1) pitch for routine abdominal/pelvic imaging with multislice computed tomography. J Comput Assist Tomogr 27(2):105–109CrossRefPubMed
7.
Zurück zum Zitat Hou DJ, Tso DK, Davison C, Inacio J, Louis LJ, Nicolaou S, Reimann AJ (2013) Clinical utility of ultra high pitch dual source thoracic CT imaging of acute pulmonary embolism in the emergency department: are we one step closer towards a non-gated triple rule out? Eur J Radiol 82(10):1793–1798CrossRefPubMed Hou DJ, Tso DK, Davison C, Inacio J, Louis LJ, Nicolaou S, Reimann AJ (2013) Clinical utility of ultra high pitch dual source thoracic CT imaging of acute pulmonary embolism in the emergency department: are we one step closer towards a non-gated triple rule out? Eur J Radiol 82(10):1793–1798CrossRefPubMed
8.
Zurück zum Zitat Jones SE, Wittram C (2005) The indeterminate CT pulmonary angiogram: imaging characteristics and patient clinical outcome. Radiology 237(1):329–337CrossRefPubMed Jones SE, Wittram C (2005) The indeterminate CT pulmonary angiogram: imaging characteristics and patient clinical outcome. Radiology 237(1):329–337CrossRefPubMed
9.
Zurück zum Zitat Yeo JH, Zhou L, Lim R (2017) Indeterminate CT pulmonary angiogram: why and does it matter? J Med Imaging Radiat Oncol 61(1):18–23CrossRefPubMed Yeo JH, Zhou L, Lim R (2017) Indeterminate CT pulmonary angiogram: why and does it matter? J Med Imaging Radiat Oncol 61(1):18–23CrossRefPubMed
10.
Zurück zum Zitat Martini K, Meier A, Higashigaito K, Saltybaeva N, Alkadhi H, Frauenfelder T (2016) Prospective randomized comparison of high-pitch CT at 80 kVp under free breathing with standard-pitch CT at 100 kVp under breath-hold for detection of pulmonary embolism. Acad Radiol 23(11):1335–1341CrossRefPubMed Martini K, Meier A, Higashigaito K, Saltybaeva N, Alkadhi H, Frauenfelder T (2016) Prospective randomized comparison of high-pitch CT at 80 kVp under free breathing with standard-pitch CT at 100 kVp under breath-hold for detection of pulmonary embolism. Acad Radiol 23(11):1335–1341CrossRefPubMed
11.
Zurück zum Zitat Tsiflikas I, Thomas C, Ketelsen D, Seitz G, Warmann S, Claussen CD, Schäfer JF (2014) High pitch computed tomography of the lung in pediatric patients: and intraindividual comparison of image quality and radiation dose to conventional 64-MDCT. Rofo 186(6):585–590CrossRefPubMed Tsiflikas I, Thomas C, Ketelsen D, Seitz G, Warmann S, Claussen CD, Schäfer JF (2014) High pitch computed tomography of the lung in pediatric patients: and intraindividual comparison of image quality and radiation dose to conventional 64-MDCT. Rofo 186(6):585–590CrossRefPubMed
12.
Zurück zum Zitat Lell MM, May M, Deak P, Alibek S, Kuefner M, Kuettner A, Köhler H, Achenbach S, Uder M, Radkow T (2011) High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography. Investig Radiol 46(2):116–123CrossRef Lell MM, May M, Deak P, Alibek S, Kuefner M, Kuettner A, Köhler H, Achenbach S, Uder M, Radkow T (2011) High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography. Investig Radiol 46(2):116–123CrossRef
13.
Zurück zum Zitat Nakagawa J, Tasaki O, Watanabe Y, Azuma T, Ohnishi M, Ukai I, Tahara K, Ogura H, Kuwagata Y, Hamasaki T, Shimazu T (2013) Reduction of thoracic aorta motion artifact with high-pitch 128-slice dual-source computed tomographic angiography: a historical control study. J Comput Assist Tomogr 37(5):755–759CrossRefPubMed Nakagawa J, Tasaki O, Watanabe Y, Azuma T, Ohnishi M, Ukai I, Tahara K, Ogura H, Kuwagata Y, Hamasaki T, Shimazu T (2013) Reduction of thoracic aorta motion artifact with high-pitch 128-slice dual-source computed tomographic angiography: a historical control study. J Comput Assist Tomogr 37(5):755–759CrossRefPubMed
Metadaten
Titel
High-pitch versus standard mode CT pulmonary angiography: a comparison of indeterminate studies
verfasst von
Derrick A. Doolittle
Adam T. Froemming
Christian W. Cox
Publikationsdatum
01.04.2019
Verlag
Springer International Publishing
Erschienen in
Emergency Radiology / Ausgabe 2/2019
Print ISSN: 1070-3004
Elektronische ISSN: 1438-1435
DOI
https://doi.org/10.1007/s10140-018-1656-1

Weitere Artikel der Ausgabe 2/2019

Emergency Radiology 2/2019 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.